• Title/Summary/Keyword: measuring force

Search Result 950, Processing Time 0.029 seconds

Electro-rheological Measurements of Phase Inversion of Emulsions under Shear Flow (전단응력 하에서 에멀젼 상 변이의 측정을 위한 전기 유변학적 연구)

  • Seung Jae, Baik;Young-Jin, Lee;Yoon Sung, Nam;Chin Han, Kim;Han Kon, Kim;Hak Hee, Kang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.147-151
    • /
    • 2004
  • This study aims at measuring electrical and rheological properties of cosmetic emulsions on the skin under shear flow. The effects of volume ratio and surfactants on structural changes of emulsions were examined by determining the changes of electrical resistance, viscosity, and morphology. As the ratio of the internal phase increased, the phase inversion occurred more quickly. The viscosity change was found to increase with increasing of the variation of electrical resistance of the emulsions. This phenomenon may be caused by decreased resistant force against the shear flow because of the breakdown of the internal phase. Surfactants a]so played a key ro]e on phase transition of emulsions. It is likely that polymeric surfactants anchoring on the emulsion surface reinforced the interfacial mechanical strength. As the concentration of surfactants increased, the phase transition occurred more slowly. It has been demonstrated that the phase changes of emulsions under shear flow can be monitored on the real-time basis by using a JELLI$\^$TM/ chip system, a combination of conductiometry and rheometry. Our approach is expected to a useful experimental tool for predicting the phase transition of the cosmetic products during skin application.

COMPARISON ON TENSILE BOND STRENGTH OF PERMANENT SOFT DENTURE LINERS BONDED TO THE DENTURE BASE RESIN (수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도)

  • Kim, Lae-Gyu;Chung, Moon-Kyu;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.200-211
    • /
    • 1999
  • For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

  • PDF

Study on Simulator Sickness Measure on Scene Movement Based Ship Handing Simulator Using SSQ and COP (시각적 동요 기반 선박운항 시뮬레이터에서 SSQ와 COP를 이용한 시뮬레이터 멀미 계측에 관한 연구)

  • Fang, Tae-Hyun;Jang, Jun-Hyuk;Oh, Seung-Bin;Kim, Hong-Tae
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.485-491
    • /
    • 2014
  • In this paper, it is proposed that the effects of simulator sickness due to scene movement in ship handling simulator can be measured by using center of pressure (COP) and a simulator sickness questionnaire (SSQ). For experiments of simulator sickness, twelve participants are exposed to scenes movement from ship handling simulator according to three steps of sea states. During experiments, COPs for subjects are measured by force plate. After exposure to scenes movement, subjects describe their sickness symptoms by answering the SSQ. Throughput analysing the results of scene movement, SSQ, and COP, the relation between the simulator sickness and COP is investigated. It is suggested that formulations for SSQ score and COP with respect to sea state are obtained by the curve fitting technique, and the longitudinal COP can be used for measuring the simulator sickness.

An Analysis of Sectoral GHG Emission Intensity from Energy Use in Korea (기후변화 협약 대응을 위한 산업별 온실가스 배출 특성 분석)

  • Chung, Whan-Sam;Tohno, Susumu;Shim, Sang-Yul
    • Journal of Korea Technology Innovation Society
    • /
    • v.11 no.2
    • /
    • pp.264-286
    • /
    • 2008
  • In 2006, the share of energy in Korea amounted to 28% from the total import, 97% from overseas dependency, and 83% for the national Greenhouse Gas (GHG) emission in 2004. Thus, from the aspects of economical and environmental policies, an energy analysis is very important, for the industry to cope with the imminent pressure for climate change. However, the estimation of GHG gas emissions due to an energy use is still done in a primitive way, whereby each industry's usage is multiplied by coefficients recommended from international organizations in Korea. At this level, it is impossible to formulate the prevailing logic and policies in face of a new paradigm that seeks to force participation of developing countries through so called post-Kyoto Protocol. In this study, a hybrid energy input-output (E-IO) analysis is conducted on the basis of the input-output(IO) table of 2000 issued by the Bank of Korea in 2003. Furthermore, according to economic sectors, emission of the GHG relative to an energy use is characterized. The analysis is accomplished from four points of view as follows: 1) estimating the GHG emission intensity by 96 sectors, 2) measuring the contribution ratio to GHG emissions by 14 energy sources, 3) calculating the emission factor of 3 GHG compounds, and 4) estimating the total amount of national GHG emission. The total amount estimated in this study is compared with a national official statistical number. The approach could be an appropriate model for the recently spreading concept of a Life Cycle Analysis as it analyzes not only a direct GHG emission from a direct energy use but also an associated emission from an indirect use. We expect this model can provide a form for the basis of a future GHG reduction policy making.

  • PDF

Prediction Model of Endurance Time to Isotonic Contraction Exercise for Biceps Brachii using Multiple Regression Analysis with Personal Factors and Anthropometric Data (신체측정치수를 적용하여 다중회귀 분석을 통한 위팔두갈래근 등장성 운동의 근지구력시간 예측모델 연구)

  • Jeong, Ju-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.2
    • /
    • pp.178-186
    • /
    • 2015
  • Endurance time is very important indicator to estimate muscle fatigue. In the case of measuring endurance time directly, it is dangerous for subject to perform a test until the point of failure to main time force. Therefore, this paper presents the model to estimate endirance time using indirect measurements such as personal factors and anthropometrical data. Previous studies had shown that personal factors such as gender and age were not related to endurance time, but recently studies have shown that it is estimated by using independent variable or predictor such as GTA (Gravitational Torque of the horizontal, stretched arm) and MVC (Maximum Voluntary Contraction). The present study investigated variables to estimate endurance time using personal factors and anthrometrical data during isotonic contractions. Twenty five healthy subject volunteered for this study, and performed three test sessions of isotonic contraction exercises at 10~50% respectively. Afterward the correlation coefficient and p-values were compared among regression models using personal factors and anthropometrical data. The results demonstrated that multi-regression model had significant coefficient of correlation, and was useful estimate endurance time.

Reliable and High Spatial Resolution Method to Identify the Number of MoS2 Layers Using a Scanning Electron Microscopy

  • Sharbidre, Rakesh Sadanand;Park, Se Min;Lee, Chang Jun;Park, Byong Chon;Hong, Seong-Gu;Bramhe, Sachin;Yun, Gyeong Yeol;Ryu, Jae-Kyung;Kim, Taik Nam
    • Korean Journal of Materials Research
    • /
    • v.27 no.12
    • /
    • pp.705-709
    • /
    • 2017
  • The electronic and optical characteristics of molybdenum disulphide ($MoS_2$) film significantly vary with its thickness, and thus a rapid and accurate estimation of the number of $MoS_2$ layers is critical in practical applications as well as in basic researches. Various existing methods are currently available for the thickness measurement, but each has drawbacks. Transmission electron microscopy allows actual counting of the $MoS_2$ layers, but is very complicated and requires destructive processing of the sample to the point where it will no longer be useable after characterization. Atomic force microscopy, particularly when operated in the tapping mode, is likewise time-consuming and suffers from certain anomalies caused by an improperly chosen set point, that is, free amplitude in air for the cantilever. Raman spectroscopy is a quick characterization method for identifying one to a few layers, but the laser irradiation causes structural degradation of the $MoS_2$. Optical microscopy works only when $MoS_2$ is on a silicon substrate covered with $SiO_2$ of 100~300 nm thickness. The last two optical methods are commonly limited in resolution to the micrometer range due to the diffraction limits of light. We report here a method of measuring the distribution of the number of $MoS_2$ layers using a low voltage field emission electron microscope with acceleration voltages no greater than 1 kV. We found a linear relationship between the FESEM contrast and the number of $MoS_2$ layers. This method can be used to characterize $MoS_2$ samples at nanometer-level spatial resolution, which is below the limits of other methods.

A Study on Velocity Distribution Characteristics for Each Location and Effectiveness of Straight Duct Length in a Square-sectional 180° Bended Duct (정사각형 단면을 갖는 180° 곡관에서 위치별 속도분포특성 및 직관거리의 유효성에 관한 연구)

  • Chen, Jing-Jing;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.618-627
    • /
    • 2016
  • This study numerically analyzes the characteristics of the velocity distribution for each location of a square-sectional $180^{\circ}$ bent duct using a Reynolds Stress Turbulent model. The flow parameters were varied, including the working fluids, inlet velocity, surface roughness, radius of curvature, and hydraulic diameter. The boundary conditions for computational fluid dynamics analysis were inlet temperatures of air and water of 288 K and 293 K, inlet air velocity of 3-15 m/s, inner surface roughness of 0-0.001 mm, radius of curvature of 2.5-4.5 D, and hydraulic diameter of 70-100 mm. The working fluid characteristics were highly affected by changes in the viscous force. The maximum velocity profiles in the bent duct were indicated when the $90^{\circ}$ section was in the region of X/D=0.8 and the $180^{\circ}$ section was in the region of Y/D=0.8. Lower surface roughness and higher radius of curvature resulted in a higher rate of velocity change. Also, an efficient measuring location downstream of the bent duct is suggested since the flow deviations were the most stable when the straight duct length was in the region of L/D=30. The minimum deviations at the same velocity conditions according to the hydraulic diameter were mostly indicated in the range of L/D=15-30 based on the standard deviation characteristics.

RHEOLOGICAL CHARACTERIZATION OF COMPOSITES USING A VERTICAL OSCILLATION RHEOMETER (수직 진동형 Rheometer를 이용한 복합레진의 유변학적 성질의 측정)

  • Lee, In-Bog;Cho, Byung-Hoon;Son, Ho-Hyun;Lee, Sang-Tag;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.489-497
    • /
    • 2004
  • Objective: The purpose of this study was to investigate the viscoelastic properties related to handling characteristics of composite resins, Methods: A custom designed vertical oscillation rheometer (VOR) was used for rheological measurements of composites. The VOR consists of three parts: (1) a measuring unit, (2) a deformation induction unit and (3) a force detecting unit, Two medium viscous composites, Z100 and Z250 and two packable composites, P60 and SureFil were tested. The viscoelastic material function, including complex modulus $E^{*}$ and phase angle ${\delta}$, were measured. A dynamic oscillatory test was used to evaluate the storage modulus (E'), loss modulus (E") and loss tangent ($tan{\delta}$) of the composites as a function of frequency ($\omega$) from 0.1 to 20 Hz at $23^{\circ}C$. Results: The E' and E" increased with increasing frequency and showed differences in magnitude between brands. The $E^{*}s$ of composites at ${\omega}{\;}={\;}2{\;}Hz$, normalized to that of Z100, were 2.16 (Z250), 4,80 (P60) and 25.21 (SureFil). The magnitudes and patterns of the change of $tan{\delta}$ of composites with increasing frequency were significantly different between brands. The relationships between the complex modulus $E^{*}$, the phase angle ${\delta}$ and the frequency \omega were represented by frequency domain phasor form, $E^{*}{\;}(\omega){\;}={\;}E^{*}e^{i{\delta}}{\;}={\;}E^{*}{\angle}{\delta}$. Conclusions: The viscoelasticity of composites that influences handling characteristics is significant different between brands, The VOR is a relatively simple device for dynamic, mechanical analysis of high viscous dental composites. The locus of frequency domain phasor plots in a complex plane is a valuable method of representing the viscoelastic properties of composites.

EFFECT OF CAVITY DIVERGENCY ON CEMENT THICKNESS AND BOND STRENGTH OF RESIN INLAY (와벽 이개도가 레진 인레이의 시멘트 두께 및 접착 강도에 미치는 영향)

  • Cha, Yoon-Seog;Cho, Yong-Bum;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.619-627
    • /
    • 1996
  • There are increasing use of composite resin in the posterior teeth and the new indirect inlay technique was introduced for compensating much troubles faced in direct technique. Many researchers insisted that overall properties of restorative materials were enhanced by an additional curing but this technique still has a problems about using cement material. Resin inlay obtains retention force from friction and another adhesion to tooth structure. A shape of cavity preparation was noted but studies about cement thickness and bond strength with cavity divergency are rare. The purpose of this study is to assess the effect of cavity divergency on cement thickness and bond strength of resin inlay. Cavities, which divergency was $6^{\circ}$, $16^{\circ}$, and $26^{\circ}$ in each group, were prepared and their divergency was verified by Adobe Photoshop program through the image capture with stereo microscope and FlexCam. Inlays were fixed into the cavities with a resin cement, Superbond and were handled under chemical (in 75% ethanol for 24 hrs.) and thermal stress (500 cycles from $5^{\circ}$ to $55^{\circ}C$). MXT 70 (x400) was used for measuring the cement thickness and bond strength was evaluated with a universal testing machine. Following results were obtained : 1. The cement thickness in Mean (S.D.) were; 35.58 (10.31)${\mu}m$ in $6^{\circ}$ group, 35.97 (10.49)${\mu}m$ in $16^{\circ}$ group, and 41.43 (9.33)${\mu}m$ in $26^{\circ}$ group. But there was no significant difference between groups. 2. The bond strength in Mean (S.D.) were ; 33.18 (5.53)kg in $6^{\circ}$ group, 23.47 (13.40)kg in $16^{\circ}$ group, and 19.75 (10.48)kg in $26^{\circ}$ group. $6^{\circ}$ group showed significantly higher value compared to $16^{\circ}$ and $26^{\circ}$ groups (p<0.05). Although the results of this study indicate $6^{\circ}$ divergency will be good for resin inlay, cavity preparation with this type will have lots of difficulties in manufacturing, try-in, and cementation procedures, such as deformation. So it is concluded that $16^{\circ}$ divergent cavity preparation is recommended in resin inlay technique.

  • PDF

Grip Strength as a Predictor of Cerebrovascular Disease (뇌혈관질환의 예측인자로서의 악력)

  • Jung, Seok-Hwan;Kim, Jae-Hyun
    • Health Policy and Management
    • /
    • v.29 no.3
    • /
    • pp.303-311
    • /
    • 2019
  • Background: Cerebrovascular disease is included in four major diseases and is a disease that has high rates of prevalence and mortality around the world. Moreover, it is a disease that requires a high cost for long-term hospitalization and treatment. This study aims to figure out the correlation between grip strength, which was presented as a simple, cost-effective, and relevant predictor of cerebrovascular disease, and cerebrovascular disease based on the results of a prior study. And furthermore, our study compared model suitability of the model to measuring grip strength and relative grip strength as a predictor of cerebrovascular disease to improve the quality of cerebrovascular disease's predictor. Methods: This study conducted an analysis based on the generalized linear mixed model using the data from the Korea Longitudinal Study of Ageing from 2006 to 2016. The research subjects consisted of 9,132 middle old age people aged 45 years or older at baseline with no missing information of education level, gender, marital status, residential region, type of national health insurance, self-related health, smoking status, alcohol use, and economic activity. The grip strength was calculated the average which measured 4 times (both hands twice), and the relative grip force was divided by the body mass index as a variable considering the anthropometric figure that affects the cerebrovascular disease and the grip strength. Cerebrovascular diseases, a dependent variable, were investigated based on experiences diagnosed by doctors. Results: An analysis of the association between grip strength and found that about 0.972 (odds ratio [OR], 0.972; 95% confidence interval [CI], 0.963-0.981) was the incidence of cerebral vascular disease as grip strength increased by one unit increase and the association between relative grip strength and cerebrovascular disease found that about 0.418 (OR, 0.418; 95% CI, 0.342-0.511) was the incidence of cerebral vascular disease as relative grip strength increased by unit. In addition, the model suitability of the model for each grip strength and relative grip strength was 11,193 and 11,156, which means relative grip strength is the better application to the predictor of cerebrovascular diseases, irrespective of other variables. Conclusion: The results of this study need to be carefully examined and validated in applying relative grip strength to improve the quality of predictors of cerebrovascular diseases affecting high mortality and prevalence.