• Title/Summary/Keyword: measurement tool

Search Result 2,198, Processing Time 0.024 seconds

Condition Monitoring of Tool wear using Sound Pressure and Fuzzy Pattern Recognition in Turning Processes (선삭공정에서 음압과 퍼지 패턴 인식을 이용한 공구 마멸 감시)

  • 김지훈
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.164-169
    • /
    • 1998
  • This paper deals with condition monitoring for tool wear during tuning operation. To develop economic sensing and identification methods for turning processes, sound pressure measurement and digital signal processing technique are proposed. To identify noise sources of tool wear and reject background noise, noise rejection methodology is proposed. features to represent condition of tool wear are obtained through analysis using adaptive filter and FFT in time and frequency domain. By using fuzzy pattern recognition, we extract features, which are sensitive to condition of tool wear, from several features and make a decision on tool wear. The validity of the proposed system is condirmed through the large number of cutting tests in two cutting conditions.

  • PDF

Comparative Study on the Configuration Factors and Measurement Method of Yangsaeng Gigong and Psychological Skills Training (양생기공과 심리기술훈련의 구성요인과 측정평가방법의 비교 연구)

  • Jung, Mi-Young;Han, Chang-Hyun;Park, Soo-Jin;Lee, Sang-Nam;Kwon, Young-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.5
    • /
    • pp.1047-1056
    • /
    • 2008
  • If we can evaluate the training results more appropriately and analyze the psychological changes in more objectively, the training can be more efficient and it can help to solve the problems during the training. This research analyzed the similarity and differences of Yangseng Qigong and psychological skill training's components and measurement methods. Also, the research further studied psychological skill training's measurement method. Results : The measurement type of Yangseng Qigong are Sagong, a record of Sagong, Damgong, IIgi, and Sogyeol. Similarly, the measurement type of psychological skills training are questionnaire, interview, personal profile, and observation of a single subject. Despite the similarities between the measurement type of Yangsaeng Qigong and psychological skills training, unfortunately there are differences in the contents. Thus, If we introduce strengths of each method to the other, we may have better measurement methods. The questionnaire method of psychological skills training is the most commonly used method, because it gives concrete, objective, reliable and highly reproducible results. If we refer to the questionnaire development process in psychological skills training, we can have objective and concrete measurement tool for Yangsaeng Qigong training. In the psychological skills training measurement tool development process, there are 5 stages; test conception, test preparation, test execution, question analysis, and test modification. Furthermore, the requirements for the good survey are reliability, validity, practicality, and cultural appropriateness. Through this study, we reached the conclusion that we need to combine two methods together to develop a better method because Yangsaeng Qigong places importance on comprehensive method and realization while psychological skills training places importance on analytical method and objective evaluation. And It seems that a practical study is needed to resolve the concerete problems of Yansaeng Qigong through these concrete cases.

A Study on the Tool Vibration Measurement Using the Fiber Optic Interferometric Sensor in Lathe Cutting Process (광섬유 간섭계 센서를 이용한 선삭가공 공구진동 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.32 no.2
    • /
    • pp.171-187
    • /
    • 2007
  • The purpose of this study is to measure the lathe tool vibration and verify its usefulness using the fiber optic interferometeric sensor instead of using common accelerometer. To compare two vibration signals a Fabry-Perot fiber optic sensor(FOS) is directly attached to the left-side surface of the lathe tool and an accelerometer is attached near to the fiber optic sensor. Measurement signals from the FOS and theoretical results of receptance simulation are compared. When the amplitude of tool vibration increased the frequency shift phenomena was occurred. This means that mass effect occurred and vibration spectrum moved to the low frequency region. Generally this results is agreement to the regenerative chatter. The chatter frequency is not same as the natural frequency of the tool itself. The FOS can also applied to laboratory experiments for students. This experimental technique is perhaps the first attempts because of directly attachment technique. Therefore, suggested Fabry-Perot fiber optic sensor can be used to monitoring the tool wear and vibration.

Development and Validation of CSR Measurement Tool of Tourism and Hotel Companies: Focusing on Vietnamese companies (관광 및 호텔 기업의 사회적 책임활동 측정 도구개발 및 타당화: 베트남 기업을 중심으로)

  • Cho, Minje;Oh, Ji-Young
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.4
    • /
    • pp.163-178
    • /
    • 2021
  • Purpose - The purpose of this study is to develop a tool to measure the corporate social responsibility activities of tourism and hotel companies using ISO26000 and to verify its reliability and validity. Design/Methodology/Approach - This study is the development of a tool for evaluating social responsibility activities of tourism and hotel companies. For this, as the first stage filer research, 4 experts developed the questions based on ISO26000. And 12 experts (academia, industry) were surveyed by Delphi to evaluate suitability. Finally, the validity and reliability of the development tool were verified for a total of 55 incumbents and related persons. Research Results - For the development of a tool for measuring social responsibility activities of tourism and hotel companies, based on the standard draft of ISO26000, questions that fit 7 core areas were composed (60 questions). In addition, a Delphi survey was conducted on a panel of 12 experts, and a total of 45 questions were derived. Finally, as a result of an exploratory factor analysis of 55 field experts, 20 items consisting of 6 factors were finally confirmed as a measuring tool for social responsibility activities of tourism and hotel companies. Research implications or originality - It is significant for the first development of a social responsibility activity scale suitable for the situation of tourism and hotel companies by applying ISO26000. This will raise awareness of the importance of social responsibility activities in the tourism industry environment, and will help tourism companies to develop a positive awareness of social responsibility activities and to prepare effective implementation strategies.

Development of Sexual Satisfaction Measurement Tool (여성의 성만족 측정을 위한 도구개발)

  • 김숙남;장순복;강희선
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.753-764
    • /
    • 1997
  • This study was conducted to develop a sexual satisfaction tool for married women in Korea. The data was collected from July 19 to Aug 18, 1997 by means of questionnaires developed by researchers. The subject were 417 married women living in Seoul and Pusan. The process of this study was as follows : 1) The concept of sexual satisfaction was defined. 2) A conceptual framework was identified based on the extensive review of relevant literature and interviews with married women. 3) The preliminary question items containing the attributes and elements of the concept of sexual satisfaction were listed. 4) The preliminary items were revised after a pilot study. 5) The Index of Content Validity(CVI) was calculated from the content specialists' rating. 6) The reliability and validity of the sexual satisfaction measurement tool were tested. As a result of the item and factor analysis, 17 out of 30 items were found to be valid, consequently could be used to measure sexual satisfaction for married women. These final 17 items were divided into two factors. These factors were labeled as "situation factor" (10 items) and "response factor"(7 items) according to the attributes of the clustered items. The reliability of the final 17 items was .9118. Further research is needed to confirm the reliability and validity of the tool by applying it to a group of healthy married women and to a group of married women having health-related problem.

  • PDF

Development of Patient-Centered Healthcare Services Evaluation Scale (환자중심 의료서비스 평가도구 개발)

  • Lee, So Ra;Yang, Nam Young
    • Journal of Home Health Care Nursing
    • /
    • v.27 no.2
    • /
    • pp.198-209
    • /
    • 2020
  • Purpose: This study sought to develop a scale to evaluate patient-centered healthcare services at hospitals and verify its reliability and validity. Methods: We conducted a literature review and interviewed medical personnel and practitioners in medical institutions. We also conducted a content validation and preliminary survey of experts, including 40 preliminary items. We conducted the main survey among 240 medical institution workers to assess the validity and reliability of the preliminary measurement tool. Results: The validity and reliability of the scale were assessed by 29 items underlying six factors: ease of communication, continuity and extension of the hospital's role, stable environment, emotional support, respect for patients' values, and offer of information. Cronbach's α of the whole tool was .91, while the value of each factor ranged from .82 to .74, thereby verifying its reliability. Conclusion: The patient-centered healthcare services scale was identified as a tool appropriate for healthcare professionals. This tool will be useful in a diverse range of research on the development of educational programs for patient-centered healthcare services and the promotion of patient-centered causes.

A Study on Sasang Constitutional Classification Factor using Sasang Constitutional Analysis Tool 2 (사상체질진단툴 2를 활용한 사상체질 분류 인자 연구)

  • Kim, Eun-Ju;Seo, Seung-Ho;Park, Seong-Eun;Na, Chang-Su;Son, Hong-Seok
    • Journal of Sasang Constitutional Medicine
    • /
    • v.30 no.3
    • /
    • pp.40-47
    • /
    • 2018
  • Objectives The purpose of this study is to analyze the factors contributing to the classification of Sasang Constitution using Sasang Constitutional Analysis Tool 2. Methods A total of 99 subjects were assessed for the classification of Sasang Constitution using four measurement factors (face, voice, body shape, and questionnaire information) of Sasang Constitutional Analysis Tool 2. Results Taeeumin had significantly higher body weight and BMI. In the result of the agreement between the judgment of the four measurement factors and the final judgment of Sasang Constitution, the agreement degree of Soeumin was the highest value of 2.6. Taeeumin, Soeumin, and Soyangin showed the highest agreement with the individual judgment of face, body shape and questionnaire, and body shape, respectively. Conclusions It is difficult to conclude that any individual factor contributes significantly to the classification of Sasang Constitution. Further study on Sasang Constitutional Analysis Tool 2 involving more peoples is needed in order to determine the factors contributing to the classification of Sasang Constitution.

Estimation of Anti-vibration Glove Performance Considering the Vibration Characteristic of Power Tool through Development of Flexible Palm Adapter (Flexible Palm 어댑터의 개발을 통한 동력 공구의 진동 특성을 고려한 방진장갑의 성능 평가)

  • Song, Chi-Mun;Jang, Han-Kee;Hong, Seok-In;Chai, Jang-Bom
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.217-224
    • /
    • 2009
  • This study aims to show the guideline to select optimal anti-vibration gloves for specific power tools to prevent hazardous vibration to human body. It is most desirable for the correct evaluation of handtransmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm as recommended in ISO 5349-1. First, the accurate acceleration measurement device was developed of which the thickness and weight were less than 6 mm and 12 g respectively so that it can be placed between the handle and the palm without any inconvenience during the measurement. Finally, using the device we estimated anti-vibration glove performances considering the frequency characteristics of generated vibration by the power tool.

Development and Application of Tool for Measuring High School Students' Scientific Experience (고등학생의 과학 경험 측정을 위한 도구의 개발 및 적용)

  • Kim, Nak-Kyu;Ryu, Chun-Ryol
    • Journal of the Korean earth science society
    • /
    • v.31 no.3
    • /
    • pp.276-287
    • /
    • 2010
  • The purpose of this study is to develop a measurement tool quantifying the degree of high school students' scientific experience. Based on previous studies, we divided the factors that compose school scientific experience into three categories: general activity experience, scientific inquiry experience and laboratory apparatus experience. While, outside of school scientific experience was divided into general activity experience, interesting activity experience and field trip experience. Items consisting each factor were selected from scientific experience measurement tools used in previous researches, most frequent answers showed in open questionnaire about scientific experiences, and exploratory analysis of textbooks. After the measurement tool developed by pilot-questionnaires and previous researches were preliminary tested and then was secondarily tested for a group of 413 high school students. The content validity and construct validity of the measurement tool was evaluated by two school teachers and two experts in science education and by factor analysis, respectively. The reliability of the tool was estimated with Cronbach Alpha. The results of validity and reliability revealed that the tool was appropriate for measuring scientific experience.

Tool Wear and Fracture Monitoring through the Sound Pressure in Turning Process (음압을 이용한 선삭작업에서의 마모, 파손 감시)

  • 이성일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.82-87
    • /
    • 1997
  • In order to make unmanned machining systems with satisfactory performances, it is necessary to incorporate appropriate condition monitoring systems in the machining workstation to provide the required intelligence of the expert. This paper deals with condition monitoring for tool wear and fracture during turning operation. Developing economic sensing and identification methods for turning processes, sound pressure measurement and digital signal processing technique are proposed. The validity of the proposed system is confirmed through the large number of cutting tests.

  • PDF