• 제목/요약/키워드: measurement interval

검색결과 689건 처리시간 0.025초

Degradation of thin carbon-backed lithium fluoride targets bombarded by 68 MeV 17O beams

  • Y.H. Kim;B. Davids;M. Williams;K.H. Hudson;S. Upadhyayula;M. Alcorta;P. Machule;N.E. Esker;C.J. Griffin;J. Williams;D. Yates;A. Lennarz;C. Angus;G. Hackman;D.G. Kim;J. Son;J. Park;K. Pak;Y.K. Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.919-926
    • /
    • 2023
  • To analyze the cause of the destruction of thin, carbon-backed lithium fluoride targets during a measurement of the fusion of 7Li and 17O, we estimate theoretically the lifetimes of carbon and LiF films due to sputtering, thermal evaporation, and lattice damage and compare them with the lifetime observed in the experiment. Sputtering yields and thermal evaporation rates in carbon and LiF films are too low to play significant roles in the destruction of the targets. We estimate the lifetime of the target due to lattice damage of the carbon backing and the LiF film using a previously reported model. In the experiment, elastically scattered target and beam ions were detected by surface silicon barrier (SSB) detectors so that the product of the beam flux and the target density could be monitored during the experiment. The areas of the targets exposed to different beam intensities and fluences were degraded and then perforated, forming holes with a diameter around the beam spot size. Overall, the target thickness tends to decrease linearly as a function of the beam fluence. However, the thickness also exhibits an increasing interval after SSB counts per beam ion decreases linearly, extending the target lifetime. The lifetime of thin LiF film as determined by lattice damage is calculated for the first time using a lattice damage model, and the calculated lifetime agrees well with the observed target lifetime during the experiment. In experiments using a thin LiF target to induce nuclear reactions, this study suggests methods to predict the lifetime of the LiF film and arrange the experimental plan for maximum efficiency.

제주도 삼나무 수간재적표 개발을 위한 주요 수간곡선식 비교 (Evaluation of Major Taper Equation Models for Developing a Stem Volume Table of Cryptomeria japonica in Jeju Island)

  • 김현수;정수영;이광수
    • 한국환경과학회지
    • /
    • 제31권11호
    • /
    • pp.941-950
    • /
    • 2022
  • This study was conducted to provide data and stem information to establish a local volume table of Cryptomeria japonica in Jeju Island. Stem analysis was performed on 26 trees by selecting two average trees from each site of the 13 plots of C. japonica stands in 2021 and 2022. During the analysis stage, one outlier tree was rejected, and a total of 260 observations of the specific stem height of 25 trees were used. Of the seven major taper equation models applied for parameter estimation and statistical verification, the Muhairwe 1999 model was found to be the best fit and selected as the optimal model. Stem shape-related estimates were acquired through the selected model, and sectional measurements according to the Smalian formula applied at an interval of 10 cm from the height of the stem were used to develop a volume table. A paired t-test comparison between the C. japonica volume obtained from the present study and those selected from the current yield table by NIFoS(2020), revealed significant differences (p<0.05), highlighting the necessity of a local volume table for C. japonica in Jeju Island.

조정 종목 상비군 선수의 훈련기 신체구성 및 영양섭취에 관한 연구 (A Study of Body Composition and Energy Intake for Intensive Training Period on Junior Rowing Team Players)

  • 김수남;박주희;김세환
    • 운동영양학회지
    • /
    • 제13권2호
    • /
    • pp.123-130
    • /
    • 2009
  • The purpose of this study was to provide the basic information on nutritional condition for improving performance of the national junior rowing team players(male n=17, female n=14). To attain this purpose, their body composition and energy intake situations were investigated during their three-week winter training camp. Measurement of body composition measured by the interval, and two days, and dietary intake in this study to investigate the type and amount of food, the researchers measured directly, and then refer to the record subjects to investigate the dietary intake and the adoption of a Weighing Method. The result is as follows. During training, body composition due to the high intensity training to maintain a properly balanced diet is the consumption of energy, weight and body composition has a positive influence. The male players' average energy intake is 5,951.6 kcal(72.6 kcal/kgBW, 150%), the rate of the three main nutrients, carbohydrate, fat, protein, is 72.6 : 8.7 : 18.7 respectively. For the female, the average energy intake is 3,685.6 kcal(51.8 kcal/kgBW, 121%), and the rate of the three main nutrients is 76.3 : 8.5 : 15.2. Both of male and female were taken sufficient Vitamin, mineral and other nutrient according to %RI(recommended intake). Based on the results of a survey of elite athletes and nutrition management and the systematic introduction and review of the program in conjunction with a professional nutritionist would need, and can also be applied to expand the school to the scene, the reality of the program review and development of qualified need.

Outcome of endodontic treatments performed by Brazilian undergraduate students: 3- to 8-year follow up

  • Jessica Gabriele da Rocha;Isabella Marian Lena;Jessica Lopes Trindade;Gabriela Salatino Liedke;Renata Dornelles Morgental;Carlos Alexandre Souza Bier
    • Restorative Dentistry and Endodontics
    • /
    • 제47권3호
    • /
    • pp.34.1-34.12
    • /
    • 2022
  • Objectives: This study aimed to evaluate the success rate of endodontic treatments performed by undergraduate students and the factors associated with the outcome. Materials and Methods: A follow-up of 3 to 8 years after root canal filling was carried out in 91 patients. At the follow-up visits, medical and dental history questionnaires were applied along with clinical and radiographic examinations. Data collected in the clinical exam included: the presence of pain, swelling, sinus tract, mobility, tenderness to palpation and percussion, periodontal probing profile, and type/quality of coronal restoration. Postoperative and follow-up radiographs were digitalized and analyzed by 2 trained and calibrated examiners to assess periapical healing. The treatment outcome was based on strict clinical and radiographic criteria and classified as success (absence of any clinical and radiographic sign of apical periodontitis) or failure (other combination). Logistic regression was used to investigate the impact of clinical and radiographic variables on endodontic treatment outcomes at a 5% significance level. Results: The success rate of endodontic treatments was 60.7%. The only risk factor significantly associated with failure was the presence of a periapical lesion on the postoperative radiograph (odds ratio, 3.35; 95% confidence interval, 1.17-9.54). Conclusions: The success rate of endodontic treatments performed by undergraduate students was low and was jeopardized by the presence of a periapical lesion on the postoperative radiograph.

나노초 레이저 가공을 활용한 초소수 표면 특성을 가지는 사출 금형에 관한 연구 (A Study on the Injection Mold with Superhydrophobic Surface Properties Using Nanosecond Laser Machining)

  • 박정래;김혜진;박지영;성시명;홍서연;송기혁
    • Design & Manufacturing
    • /
    • 제17권3호
    • /
    • pp.48-54
    • /
    • 2023
  • In this study, an injection mold with ultra-small surface properties was manufactured using nanosecond laser processing. A superhydrophobic characteristic analysis was performed on the PET specimen manufactured through this. To this end, a hydrophobic pattern was defined using the Cassie-Baxter model. The defined features were selected with a spot diameter of 25um and pitch spacing of 30um and 35um. As a result of the basic experiment, it was confirmed that the fine pattern shape had an aspect ratio of 1:1 when the pitch interval was 35um and 20 iterations. Through the determined processing conditions, a hydrophobic pattern was implemented on the core surface of KP4. A specimen with a hydrophobic pattern was produced through injection molding. The height of the molded hydrophobic pattern is 20 ㎛ less than the depth of the core and the contact angle measurement results are 92.1°. This is a contact angle smaller than the superhydrophobic criterion. Molding analysis was performed to analyze the cause of this, and it was analyzed that the molding was not molded due to the lack of pressure in the injection machine.

Measurement of atherosclerosis markers in individuals with periodontitis

  • Angar Soronzonbold;Erkhbilguun Munkhkherlen;Khongorzul Batchuluun;Oyun-Enkh Puntsag;Uurtuya Shuumarjav;Bayarchimeg Batbayar
    • Journal of Periodontal and Implant Science
    • /
    • 제54권1호
    • /
    • pp.37-43
    • /
    • 2024
  • Purpose: The inflammatory response due to inflammatory cytokines, bacterial pathogens, and the altered lipoprotein metabolism in patients with periodontitis indicates that infection with periodontal anaerobic bacteria may influence atherogenesis in vitro and in vivo. We aimed to explore the effect of periodontitis concerning clinical and ultrasound markers of early atherosclerosis. Methods: In this case-control study, a total of 30 systemically healthy adults (15 with periodontitis and 15 without periodontitis) over 40 years of age were studied. Periodontitis was determined by measuring the clinical attachment level (CAL) and radiographic bone loss (RBL). Conventional cardiovascular risk factors, including body mass index, serum levels of total cholesterol (TCH), triglycerides (TG), and high-density and low-density lipoprotein (HDL and LDL, respectively) cholesterol were evaluated. Carotid artery intima-media thickness (IMT) was measured using ultrasonography. Results: The mean values of the CAL and carotid IMT were 5.02±0.9 mm and 0.084±0.01 cm vs. 1.6±0.61 mm and 0.072±0.02 cm in the periodontitis and healthy groups, respectively, reflecting statistically significant differences (P=0.001 and P=0.037, respectively). There were statistically significant differences in the serum levels of TCH, TG, and LDL between the 2 groups (P=0.017). The CAL and RBL were positively associated with carotid IMT and serum cholesterol levels, except for HDL, whereas tooth loss was not associated with any markers (P<0.05). Compared to the healthy group, participants with periodontitis exhibited 2.09 times higher odds (95% confidence interval, 1.22-3.59) of having subclinical atherosclerosis. Conclusions: The presence of periodontitis increased the risk of atherosclerosis.

Risk Factor Analysis of Cryopreserved Autologous Bone Flap Resorption in Adult Patients Undergoing Cranioplasty with Volumetry Measurement Using Conventional Statistics and Machine-Learning Technique

  • Yohan Son;Jaewoo Chung
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권1호
    • /
    • pp.103-114
    • /
    • 2024
  • Objective : Decompressive craniectomy (DC) with duroplasty is one of the common surgical treatments for life-threatening increased intracranial pressure (ICP). Once ICP is controlled, cranioplasty (CP) with reinsertion of the cryopreserved autologous bone flap or a synthetic implant is considered for protection and esthetics. Although with the risk of autologous bone flap resorption (BFR), cryopreserved autologous bone flap for CP is one of the important material due to its cost effectiveness. In this article, we performed conventional statistical analysis and the machine learning technique understand the risk factors for BFR. Methods : Patients aged >18 years who underwent autologous bone CP between January 2015 and December 2021 were reviewed. Demographic data, medical records, and volumetric measurements of the autologous bone flap volume from 94 patients were collected. BFR was defined with absolute quantitative method (BFR-A) and relative quantitative method (BFR%). Conventional statistical analysis and random forest with hyper-ensemble approach (RF with HEA) was performed. And overlapped partial dependence plots (PDP) were generated. Results : Conventional statistical analysis showed that only the initial autologous bone flap volume was statistically significant on BFR-A. RF with HEA showed that the initial autologous bone flap volume, interval between DC and CP, and bone quality were the factors with most contribution to BFR-A, while, trauma, bone quality, and initial autologous bone flap volume were the factors with most contribution to BFR%. Overlapped PDPs of the initial autologous bone flap volume on the BRF-A crossed at approximately 60 mL, and a relatively clear separation was found between the non-BFR and BFR groups. Therefore, the initial autologous bone flap of over 60 mL could be a possible risk factor for BFR. Conclusion : From the present study, BFR in patients who underwent CP with autologous bone flap might be inevitable. However, the degree of BFR may differ from one to another. Therefore, considering artificial bone flaps as implants for patients with large DC could be reasonable. Still, the risk factors for BFR are not clearly understood. Therefore, chronological analysis and pathophysiologic studies are needed.

Postoperative analgesic effects of the quadratus lumborum block in pediatric patients: a systematic review and meta-analysis

  • Insun Park;Jae Hyon Park;Hyun-Jung Shin;Hyo-Seok Na;Bon-Wook Koo;Jung-Hee Ryu;Ah-Young Oh
    • The Korean Journal of Pain
    • /
    • 제37권1호
    • /
    • pp.59-72
    • /
    • 2024
  • Background: This study assessed the postoperative analgesic efficacy and safety of the quadratus lumborum block (QLB) in pediatric patients. Methods: Electronic databases were searched for studies comparing the QLB to conventional analgesic techniques in pediatric patients. The primary outcome was the need for rescue analgesia 12 and 24 hours after surgery. Secondary outcomes covered the Face-Legs-Activity-Cry-Consolability Scale (FLACC) scores at various time points; parental satisfaction; time to the first rescue analgesia; hospitalization time; block execution time; block failure rates, and adverse events. Results: Sixteen randomized controlled trials were analyzed involving 1,061 patients. The QLB significantly reduced the need for rescue analgesia both at 12 and 24 hours after surgery (12 hours, relative risk [RR]: 0.45; 95% confidence interval [CI]: 0.01, 0.88; 24 hours, RR: 0.51; 95% CI: 0.31, 0.70). In case of 24 hours after surgery, type 1 QLB significantly reduced the need for rescue analgesia (RR: 0.56; 95% CI: 0.36, 0.76). The QLB also exhibited lower FLACC scores at 1 hour (standardized mean difference [SMD]: -0.87; 95% CI: -1.56, -0.18) and 6 hours (SMD: -1.27; 95% CI: -2.33, -0.21) following surgery when compared to non-QLB. Among QLBs, type 2 QLB significantly extended the time until the first rescue analgesia (SMD: 1.25; 95% CI: 0.84, 1.67). No significant differences were observed in terms of parental satisfaction, hospitalization time, block execution time, block failure, or adverse events between QLB and non-QLB groups. Conclusions: The QLB provides non-inferior analgesic efficacy and safety to conventional methods in pediatric patients.

Clinical and Imaging Parameters Associated With Impaired Kidney Function in Patients With Acute Decompensated Heart Failure With Reduced Ejection Fraction

  • In-Jeong Cho;Sang-Eun Lee;Dong-Hyeok Kim;Wook Bum Pyun
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.169-177
    • /
    • 2023
  • BACKGROUND: Acute worsening of cardiac function frequently leads to kidney dysfunction. This study aimed to identify clinical and imaging parameters associated with impaired kidney function in patients with acute decompensated heart failure with reduced ejection fraction (HFrEF). METHODS: Data from 131 patients hospitalized with acute decompensated HFrEF (left ventricular ejection fraction, < 40%) were analyzed. Patients were divided into two groups according to the glomerular filtration rate (GFR) at admission (those with preserved kidney function [GFR ≥ 60 mL/min/1.73 m2] and those with reduced kidney function [GFR < 60 mL/min/1.73 m2]). Various echocardiographic parameters and perirenal fat thicknesses were assessed by computed tomography. RESULTS: There were 71 patients with preserved kidney function and 60 patients with reduced kidney function. Increased age (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.04-1.12; p = 0.005), increased log N-terminal pro b-type natriuretic peptide (OR, 1.74; 95% CI, 1.14-2.66; p = 0.010), and increased perirenal fat thickness (OR, 1.19; 95% CI, 1.10-1.29; p < 0.001) were independently associated with reduced kidney function, even after adjusting for variable clinical and echocardiographic parameters. The optimal average perirenal fat thickness cut-off value of > 12 mm had a sensitivity of 55% and specificity of 83% for kidney dysfunction prediction. CONCLUSIONS: Thick perirenal fat was independently associated with impaired kidney function in patients hospitalized for acute decompensated HFrEF. Measurement of perirenal fat thickness may be a promising imaging marker for the detection of HFrEF patients who are more susceptible to kidney dysfunction.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.