• Title/Summary/Keyword: measurement interval

Search Result 695, Processing Time 0.032 seconds

High Resolution Hydroacoustic Investigation in Shallow Water for the Engineering Design of Railroad Bridge (철도교량 설계 지반조사를 위한 고분해능 수면 탄성파반사법의 응용 사례)

  • ;Swoboda Ulrich
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.231-238
    • /
    • 2001
  • To investigate the underground structure of shallow water, Han-river near Yangsou-Ri, high resolution hydroacoustic measurements were carried out for the engineering design of railroad bridge. The acoustic source was a Boomer with an energy of 90 to 280J and in a frequency range up to about 16KHz. The reflected signals were received by using both traditional hydrophones(passive element) and a specially devised receiver unit(active element) mainly composed of piezofilms and preamplifier. They are connected to the "SUMMIT" data acquisition system(DMT-GeoTec company), where the sampling interval was set to 1/32㎳. The source position was continuously monitored by a precision DGPS system whose positioning accuracy was on the order of loom. For the quality control purposes, two different source-receiver geometries were taken. That is to say, the measurements were repeated along the profile everytime depending on the different source energy(175J, 280J), the receiving elements(passive, active) and two different source-receiver geometries. It was shown that the data resolution derived from a proper arrangement with the active hydrophone could be greatly enhanced and hence the corresponding profile section caused by the regular data processing system "FOCUS" accounted excellently for the underground formation below the shallow water.w the shallow water.

  • PDF

Development of the iron-cored electronic current transformer (철심 코어형 전자식 변류기 개발)

  • Kang, Yong-Cheol;Kim, Yeon-Hee;Jang, Sung-Il;Park, Jong-Min;Choi, Jung-Hwan;Kim, Yong-Kyun;Lee, Byung-Sung;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.136-137
    • /
    • 2008
  • A current transformer(CT) should provide the faithful reproduction of the primary current to the measurement or the protection equipments. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the CT. A compensating algorithm for the secondary current of the current transformer that removes the effects of the hysteresis characteristics of the iron-core has proposed. The core flux linkage is calculated by integrating the measured secondary current, and then inserted into the flux-magnetizing current curve to obtain the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and added to the measured current to obtain the correct current. This paper describes the innovative new product of the iron-cored electronic current transformer. This product composes an iron-cored CT and an intelligent electronic device(IED) ported the compensating algorithm. The test results of the iron-cored electronic current transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

Wind-induced tall building response: a time-domain approach

  • Simiu, Emil;Gabbai, Rene D.;Fritz, William P.
    • Wind and Structures
    • /
    • v.11 no.6
    • /
    • pp.427-440
    • /
    • 2008
  • Estimates of wind-induced wind effects on tall buildings are based largely on 1980s technology. Such estimates can vary significantly depending upon the wind engineering laboratory producing them. We describe an efficient database-assisted design (DAD) procedure allowing the realistic estimation of wind-induced internal forces with any mean recurrence interval in any individual member. The procedure makes use of (a) time series of directional aerodynamic pressures recorded simultaneously at typically hundreds of ports on the building surface, (b) directional wind climatological data, (c) micrometeorological modeling of ratios between wind speeds in open exposure and mean wind speeds at the top of the building, (d) a physically and probabilistically realistic aerodynamic/climatological interfacing model, and (e) modern computational resources for calculating internal forces and demand-to-capacity ratios for each member being designed. The procedure is applicable to tall buildings not susceptible to aeroelastic effects, and with sufficiently large dimensions to allow placement of the requisite pressure measurement tubes. The paper then addresses the issue of accounting explicitly for uncertainties in the factors that determine wind effects. Unlike for routine structures, for which simplifications inherent in standard provisions are acceptable, for tall buildings these uncertainties need to be considered with care, since over-simplified reliability estimates could defeat the purpose of ad-hoc wind tunnel tests.

Quantitative assessment of offshore wind speed variability using fractal analysis

  • Shu, Z.R.;Chan, P.W.;Li, Q.S.;He, Y.C.;Yan, B.W.
    • Wind and Structures
    • /
    • v.31 no.4
    • /
    • pp.363-371
    • /
    • 2020
  • Proper understanding of offshore wind speed variability is of essential importance in practice, which provides useful information to a wide range of coastal and marine activities. In this paper, long-term wind speed data recorded at various offshore stations are analyzed in the framework of fractal dimension analysis. Fractal analysis is a well-established data analysis tool, which is particularly suitable to determine the complexity in time series from a quantitative point of view. The fractal dimension is estimated using the conventional box-counting method. The results suggest that the wind speed data are generally fractals, which are likely to exhibit a persistent nature. The mean fractal dimension varies from 1.31 at an offshore weather station to 1.43 at an urban station, which is mainly associated with surface roughness condition. Monthly variability of fractal dimension at offshore stations is well-defined, which often possess larger values during hotter months and lower values during winter. This is partly attributed to the effect of thermal instability. In addition, with an increase in measurement interval, the mean and minimum fractal dimension decrease, whereas the maximum and coefficient of variation increase in parallel.

Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline (단열배관의 온라인 두께측정시스템 개발)

  • Jang, Ji-Hun;Kim, Byeong-Ju;Jo, Gyeong-Sik;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.32
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF

The AS4059 Hydraulic System Cleanliness Classification System: Replacement of NAS1638

  • Day, Mik;Hong, Jeong-Hee
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.39-45
    • /
    • 2012
  • The NAS 1638 cleanliness classification system was originally developed in 1966 by the US Aircraft Industries of America to both simplify reporting of particle count data and to control the introduction of dirt during the assembly of aircraft fluid systems. The numbers of particles at stated sizes are represented by broad bands where the interval was generally a doubling of contamination. A number of systems have been introduced since this to suit differing requirements. NAS 1638 and AS4059 are used in other industrial sectors such as the Off-shore & Sub-Sea and the Primary Metal Industries. The changes to ISO contamination measurement standards controlled by ISO/TC131/SC6 in 1999 meant that a revision of most of these classification systems was necessary. The body responsible for NAS 1638 decided to withdraw it for new installations and replace it with an update of an existing standard, SAE AS 4059. This paper details the philosophy behind the contamination coding systems, the reasons for the changes to the ISO contamination standards and explains the workings of AS 4059, the replacement for NAS 1638. It goes on to detail the latest changes to this standard.

Toxicity Study of Streptococcus pneumoniae Vaccine Administrated Subcutaneously in Rats

  • Park, Sin-Jeong;Seo, Kook-Heon;Han, Sang-In
    • Toxicological Research
    • /
    • v.27 no.2
    • /
    • pp.111-118
    • /
    • 2011
  • This study was performed to evaluate the toxicity of polysaccharide-based Streptococcus pneumoniae vaccine in Specific Pathogen Free (SPF), Sprague-Dawley (SD) rats. S. pneumoniae vaccine was administrated subcutaneously each dose level of high (560 ${\mu}g$/rat), medium (280 ${\mu}g$/rat) and low (140 ${\mu}g$/rat) on days 0, 14, 28. The rats were observed for 2 weeks or 4 weeks after the final injection. During this test, there were no significant dose-dependent changes in body weight, water and food consumption. In urinalysis and serum chemistry, dose-related changes were not detected. In hematology, the percent of neutrophils and lymphocytes in white blood cells were changed significantly. According to the measurement of organ weight, only spleen weight was significantly increased in all groups of administration compared to the control group. In the histopathological examination, an antigen-deposit, vacuolated macrophages, infiltrated inflammatory cells and a formation of granulation tissue were observed at the site of an administration. These results are considered as an outcome by immune responses through a vaccination. Consequently, the results of this study demonstrated that S. pneumoniae vaccine has no toxicity when it was administrated subcutaneously three times in 2-week interval at a high dose of 560 ${\mu}g$/rat.

The Forward Prediction of Radiation Sound Field Using Acoustic Holography : Basic Theory and Signal Processing Method (음향 홀로그래피를 이용한 방사 음장의 전방예측 방법에 관한 기본 이론 및 신호처리 방법)

  • 김양한;권휴상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1654-1668
    • /
    • 1992
  • The acoustic field resulted by the radiation of sound from vibrating structure is predicted based on the sound pressure measurements. The sound pressures are measured at discreate point on the measurement plane ; Hologram. Based on these discreate measurements, the sound field away from the acoustic source is constructed based on the discreate form of Kirchhoff-Helmohltz integral equations The velocities, intensities, and pressures of arbitrary plane of interest in space are predicted and visualized The effects on the sound field reconstruction ; finite aperture effect, effect of finite sampling interval in space studied in terms of wraparound error and spatial aliasing. Numerical simulations and experimental verifications are performed to see these effects. To reduce the wraparound error, zero padding technique in space is used and the usefulness of the method is demonstrated by various examples.

An Analysis Technique of Ultrasonic Pulse Signal for Measuring Ship's Draught (선박의 홀수 측정을 위한 초음파 펄스 신호의 해석기법)

  • 이은방;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.4
    • /
    • pp.1-8
    • /
    • 1995
  • Although ship's draught information onboard is substantial for both the safety of navigation and the estimation of loaded cargoes, its accuracy depends, in conventional surveying method, on the skillfulness of observers and the condition of the sea surface round the vessel. To obtain more accurate information accessibly, measuring instruments with sophisticated sensors such as mechanical, electronic and ultrasonic transducers have been developed. However, they have still limitation in accuracy and in making up a system due to the complexity of processing signal. In this paper, we propose a new technique for analyzing ultrasonic pulse signal, in order to improve the measurement accuracy and simplify a remote sensing system of draught by ultrasonic waves. In this technique, pulse signal is translated into phase curve which is composed of the phase value defined in time domain. Then, the time interval between two signals different in waveform, is waveform, is analytically determined by calculating average time difference on phase curves. Also, analytical procedure can be carried out in real time with the successive five data sampled at T/4, for high speed digital processing with computer and A/D converter. This technique is useful for measuring draught under the influence of sea condition and for interfacing its data briefly to the integrated bridge system.

  • PDF

Size Specifications of Korean Adult Male for the Ready-made Garments (기성복 제작을 위한 성인 남성의 사이즈 스팩의 분류)

  • 김구자;이순원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1247-1257
    • /
    • 1997
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready·made garments, especially jacket and dress shirts. Concept of the comfort and fitness has become a major concern in the basic function of the ready-made garments. Data were collected by the real anthropometric measurement and by the photographic sources. Sample size was 1.290 subjects as the sample and their age range was from 19 to 54 pean old by the stratified sampling method. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SAS package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. Control dimensions for jacket and dress shirts has been designated by Bcorean Apparel Sizing System (KS-K). Therefore this study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 has the high coverage rate of 22.1%, 21.0% and 18.8% respectively and are composed of the majority of 61.9% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 65.75% of the expected frequency distribution without stature were covered by 19 size specification.

  • PDF