• Title/Summary/Keyword: measurement interval

Search Result 698, Processing Time 0.028 seconds

Design of the Variable Sampling Rates X-chart with Average Time to Signal Adjusted by the Sampling Cost

  • Park, Chang-Soon;Song, Moon-Sup
    • Journal of the Korean Statistical Society
    • /
    • v.26 no.2
    • /
    • pp.181-198
    • /
    • 1997
  • The variable sampling rates scheme is proposed by taking random sample size and sampling interval during the process. The performance of the scheme is measured in terms of the average time to signal adjusted by teh sampling cost when the process is out of control. This measurement evaluates the effectiveness of the scheme in terms of the cost incurred due to nonconformation as well as sampling. The variable sampling rates scheme is shown to be effective especially for small and moderate shifts of the mean when compared to the standard scheme.

  • PDF

Radiation Pattern of the Vibrox Transducer (자외성 페라이트 진동자의 지향특성에 대하여)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.4 no.2
    • /
    • pp.1-6
    • /
    • 1980
  • Computer simulation results on the radiation pattern of an ultrasonic beam by the plurall arrangement of the transducers were reported by Sin (1979). This paper describes on the measurement of radiation pattern in case of one vibrox transducer and two vibrox transducers by varying the interval between the transducers. The measured results obtained are as follows; 1. Radiation wave of ultrasonic transducer is propagated to diffuse with spherical wave from center of transducer. 2. In case of one vibrox transducer, the greater the length of transducer, the sharper becomes the radiation pattern. 3. In case of two vibrox transducers, the maine lobe is revealed at the center of two transducers, it is shown difficult to make control freely of radiation pattern by varying merely the interval of transducers.

  • PDF

Korean Speech Segmentation and Recognition by Frame Classification via GMM (GMM을 이용한 프레임 단위 분류에 의한 우리말 음성의 분할과 인식)

  • 권호민;한학용;고시영;허강인
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.18-21
    • /
    • 2003
  • In general it has been considered to be the difficult problem that we divide continuous speech into short interval with having identical phoneme quality. In this paper we used Gaussian Mixture Model (GMM) related to probability density to divide speech into phonemes, an initial, medial, and final sound. From them we peformed continuous speech recognition. Decision boundary of phonemes is determined by algorithm with maximum frequency in a short interval. Recognition process is performed by Continuous Hidden Markov Model(CHMM), and we compared it with another phoneme divided by eye-measurement. For the experiments result we confirmed that the method we presented is relatively superior in auto-segmentation in korean speech.

  • PDF

Interpretations of Negative Degree Sentences and Questions

  • Kwak, Eun-Joo
    • Journal of English Language & Literature
    • /
    • v.56 no.6
    • /
    • pp.1135-1161
    • /
    • 2010
  • The interpretations of degree expressions require the postulation of new entities to represent degrees. Diverse entities such as degrees, intervals, and vectors are adopted for degree expressions. Positive degree sentences and questions are properly construed with the introduction of these entities, but their negative counterparts need more consideration. Negative degree sentences show dual patterns of entailments depending on contexts, and negative degree questions are unacceptable, making weak islands. To explicate the distinct nature of negative degree sentences and questions, Fox & Hackl (2006) provide an analysis based on degrees while Abrusan & Spector (2010) suggest a proposal in interval readings of degree expressions. I have pointed out the theoretical problems of these analyses and proposed an alternative in the framework of the vector space semantics, following Winter (2005). Bi-directional scales in vector space fit well with the dual patterns of negative degree sentences, and the notion of a reference vector is useful to accommodate the contextual influence in negative degree sentences and to deal with the unacceptability of negative degree questions.

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

A Study on 2-Dimensional Sound Source Tracking System III - mainly on digital signal processing - (2차원적 음원추적에 관한 연구III - 디지털 신호처리를 중심으로 -)

  • 문성배;전승환
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.5
    • /
    • pp.443-450
    • /
    • 2000
  • Before some experiments were carried out with analog bandpass filter which used for filtering the noise included in sound source signal. And this filter was constituted by condenser, register and operational amplifier. Hut these elements made the phase characteristics to differentiate in each sensing channel and cause a little of measurement error. We made new measurement system that was substituted digital filter for the analog filter in order to develop the optimal system which could find the time delay between each sensors with high accuracy. This paper describes the new system's constitution and the function of each parts. Specially three digital filters were designed and applied to the digital signal processing Part. And a series of experiments were carried out with the source's distance 9.53meters and the random bearing interval within the limits of $0^{\circ}$ ~ $180^{\circ}$. As a result, we have recognized that the accuracy of measurements were differentiated by the methods what kind of digital filter were adopted. And we have confirmed the facts that IIR LPF was suitable for sound source's bearing measurement and FIR LPF reduced the range measurement error.

  • PDF

Two-Site Optical Observation and Initial Orbit Determination for Geostationary Earth Orbit Satellites

  • Choi, Jin;Choi, Young-Jun;Yim, Hong-Suh;Jo, Jung-Hyun;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.337-343
    • /
    • 2010
  • Optical observation system provides angle-only measurement for orbit determination of space object. Range measurement can be directly acquired using laser ranging or tone ranging system. Initial orbit determination (IOD) by using angle- only data set shows discrepancy according to the measurement time interval. To solve this problem, range measurement data should be added for IOD. In this study, two-site optical observation was used to derive the range information. We have observed nine geostationary earth orbit satellites by using two-site optical observation system. The determination result of the range shows the accuracy over 99.5% compared to the results from the satellite tool kit simulation. And we confirmed that the orbit determination by the Herrick-Gibbs method with the range information obtained from the two-site observation is more accurate than the orbit determination by Gauss method with the one-site observation. For more accurate two-site optical observation, a baseline should satisfy an optimal condition of length and more precise observation system needed.

Performance Analysis of Handover Trigger Based on Signal Strength Measurement (신호 강도 측정 기반 핸드오버 결정 방법의 성능 분석)

  • Park, Jae-Sung;Lim, Yu-Jin
    • The KIPS Transactions:PartC
    • /
    • v.14C no.7
    • /
    • pp.603-610
    • /
    • 2007
  • Effective handover decision is important for providing seamless services to mobile users. In this paper, we propose an analysis framework to evaluate the performance of handover decision based on received signal strength (RSS) measurements in terms of the late notification and false alarm probability. In our framework, we consider mobility of a mobile user, signaling delays for exchanging messages related to handover protocols, cell sizes and RSS measurement interval to stabilize RSS reading due to random measurement errors. By quantitatively scrutinizing the impact of each parameter on the late notification and false alarms, we suggest the research directions for effective handover decision mechanism that may provide fast and reliable handover.

Reliability of Scapular Winging Measurement Using a Scapulometer (익상견갑의 평가를 위한 "Scapulometer"의 신뢰도 연구)

  • Weon, Jong-Hyuek;Choi, Houng-Sik;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2010
  • This study was undertaken to develop the scapulometer, a measuring tool for scapular winging, and to determine the reliability of scapulometer. Thirty subjects with scapular winging greater than 2 cm participated in this study. Two examiners measured scapular winging using the scapulometer. Standardized measurement position of each subject was as follows: neutral position of shoulder and wrist, $90^{\circ}$ flexion of elbow, and cuff weight of 5% and 10% of body weight (BW) to neutral wrist. The interrater and intrarater reliability were calculated with an intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and standard error of measurement (SEM) at 5% BW and 10% BW. The level of scapular winging was tested between 5% BW and 10% BW with a paired t-test. The interrater reliability was shown to be high at 5% BW (ICC(2,k)=.955, 95% CI=.900~.979, SEM=.07) and at 10% BW (ICC(2,k)=.968, 95% CI=.930~.985, SEM=.06). The intrarater reliability was shown to be high at 5% BW (ICC(2,k)=.921, 95% CI=.842~.961, SEM=.09) and at 10% BW (ICC(2,k)=.906, 95% CI=.813~.954, SEM=.10). The level of scapular winging was significantly different between 5% BW and 10% BW. Conclusively, it is demonstrated that the scapulometer is an objective and qualitative measurement tool for scapular winging.

A Technique to Improve the Readability of Ancient Inscription by Using Optical Triangulation Measurement Principle (광삼각법 측정 원리를 이용한 금석문 가독성 향상 방법)

  • Lee, Geun-Ho;Ko, Sun-Woo;Choi, Won-Ho
    • Journal of Information Technology Services
    • /
    • v.11 no.sup
    • /
    • pp.103-111
    • /
    • 2012
  • In epigraph field to study ancient scripts, alternative readability improvement technologies have been developed to replace existing rubbing method which has low resolution and causes surface pollution of heritages from the viewpoints of extraction process and used materials. Recently many methods which are based on analysis of pixel data for extracting outlines of the specific image have been developed with advancement of image processing techniques. But these methods are not applicable and the results are not satisfied in the damaged inscriptions which are weathered by wind and rain for a long time and in the narrowed one. In this paper laser scanning techniques which uses optical triangulation measurement principle are developed to minimize scanning error. The proposed techniques are consisted of 3 parts:(1) the understanding of optical triangulation measurement principle to find scanning guideline (2) determinations of points interval, scanning distance and scanning angle to guarantee scanning data quality (3) identification of valid point data area which will be used in registration process. The proposed character identification method contributed in decoding an ancient inscription on SeukBingGo in Kyungju.