• 제목/요약/키워드: measurement indicator

검색결과 495건 처리시간 0.027초

한국의 보건지표 체계 개선에 관한 연구 (A study on development of health indicator system in Korea)

  • 윤치근;윤병준;이준협;김윤신
    • 보건행정학회지
    • /
    • 제13권2호
    • /
    • pp.44-66
    • /
    • 2003
  • I. Background and Purpose Health Indicator system and measurement of health status are an important fields in national health fields. This study reviewed the overall concepts of health and health indicators, health indicator system. The purposes of this study are to build the conceptual health framework, and suggest a health indicator system, in order to correspond to the situation of national health and the demand of International organizations. II. Scope and Contents The scope of this study ; - Review of tile conceptual health framework, health indicators, and health Indicator system - Selection and development of tile new individual health indicators - Suggestion of tile revised health indicator system III. Results of Study This study intented to build the conceptual and framework of national health and provide the measurement tools of health status. This study developed the health indicator system through the conceptual and hierarchial approach to national health. The health indicator system contains 6 concern: areas and each sub-areas. The major concern areas are health state and behavior, deathㆍdiseaseㆍdisability, health care utilization, health resources, health expenditure and finance, other affecting factors on health. This health indicator system is corresponding to the situation of health status patterns and the demand of international organizations. And this health indicator system is considering the present health data production system and the availability of health data.

일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가 (Daily check device manufacture and efficiency Evaluation for daily Q.A)

  • 김찬용;제영완;이제희;박흥득
    • 대한방사선치료학회:학술대회논문집
    • /
    • 대한방사선치료학회 2005년도 춘계학술대회 초록집
    • /
    • pp.19-22
    • /
    • 2005
  • 방사선 종양학과에서 실시하고 있는 일일 정도관리 항목인 out put laser alignment, field size, SSD indicator 점검을 간편하고 정확하게 할 수 있도록 phantom 모양의 daily check device를 설계하고 제작하였다. 본 장치를 사용하여 4개월(2005. $2\~5$)월 동안 4대의 선형가속기 일일 정도관리에 사용한 곁과 측정과정이 편리하고 시간이 단축되어 일일점검의 효율성이 향상 되었고, 출력선량 측정은 각 장비별로 ${\pm}\;2\%$ 이내였으며 laser, field size, SSD indicator 는 ${\pm}\;1mm$ 이내의 범위에서 측정되었다. 일일 정도관리 기록을 기초로 하여 월간, 연간 정도관리의 객관적인 기초 자료로 활용할 수 있었다. 제작된 daily check device는 기존 상품화된 고가의 측정 장비를 대체 사용가능하게 함으로써 비용절감 효과가 기대되며, 향후 장치 재질의 견고성 및 가벼운 소재의 개발이 필요할 것으로 사료된다.

  • PDF

WIRELESS SENSOR NETWORK BASED BRIDGE MANAGEMENT SYSTEM FOR INFRASTRUCTURE ASSET MANAGEMENT

  • Jung-Yeol Kim;Myung-Jin Chae;Giu Lee;Jae-Woo Park;Moon-Young Cho
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1324-1327
    • /
    • 2009
  • Social infrastructure is the basis of public welfare and should be recognized and managed as important assets. Bridge is one of the most important infrastructures to be managed systematically because the impact of the failure is critical. It is essential to monitor the performance of bridges in order to manage them as an asset. But current analytical methods such as predictive modeling and structural analysis are very complicated and difficult to use in practice. To apply these methods, structural and material condition data collection should be performed in each element of bridge. But it is difficult to collect these detailed data in large numbers and various kinds of bridges. Therefore, it is necessary to collect data of major measurement items and predict the life of bridges roughly with advanced information technologies. When certain measurement items reach predefined limits in the monitoring bridges, precise performance measurement will be done by detailed site measurement. This paper describes the selection of major measurement items that can represent the tendency of bridge life and introduces automated bridge data collection test-bed using wireless sensor network technology. The following will be major parts of this paper: 1) Examining the features of conventional bridge management system and data collection method 2) Mileage concept as a bridge life indicator and measuring method of the indicator 3) Test-bed of automated and real-time based bridge life indicator monitoring system using wireless sensor network

  • PDF

입경측정을 위한 영상처리기법에서 입자 초점면 존재 판단 기준의 설정 (Determination of In-focus Criteria In Image Processing Method for Particle Size Measurement)

  • 고광웅;김주연;이상용
    • 대한기계학회논문집B
    • /
    • 제23권3호
    • /
    • pp.398-407
    • /
    • 1999
  • In the present image processing technique, the concept of the gradient indicator(GI) has been introduced to find out the depth-of-field in sizing large particles ranging from $30{\mu}m$ to $30{\mu}m$ where using of the concept of the normalized contrast value(VC) is not appropriate. The gradient indicator is defined as the ratio of the local value to the maximum possible value of the gray-level gradient in an image frame. The gradient indicator decreases with the increases of the particle size and the distance from the exact focal plane. A particle is considered to be in focus when the value of the gradient indicator at its image boundary stays above a critical value. This critical gradient indicator($GI_{critical}$) is defined as the maximum gradient indicator($GI_{max}$) subtracted by a constant ${\Delta}GI$ which is to account for the particle-size effect. In the present ca.so, the value of ${\Delta}GI$ was set to 0.28 to keep the standard deviation of the measured particles mostly within 0.1. It was also confirmed that, to find the depth-of-field for small particles(${\leq}30{\mu}m$) with the same measurement accuracy, tho concept of the critical normalized contrast($VC_{critical}$) is applicable with 85% of the maximum normalized contrast value($VC_{max}$). Finally, the depth-of-field was checked for the size range between $10{\mu}m$ and $300{\mu}m$ when the both in-focus criteria ($GI_{critical}$ and $VC_{critical}$) were adopted. The change of the depth-of-field with the particle size shows good linearity in both the VC-applicable and the GI-applicable ranges with a reasonable accuracy.

문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가 (Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage)

  • 임보아;신은정;이선명
    • 보존과학연구
    • /
    • 통권31호
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

광촉매 반응을 이용한 총유기탄소 분석 칩 (Total Organic Carbon Analysis Chip Based on Photocatalytic Reaction)

  • 김승덕;정동건;권순열;최영찬;이재용;구성모;공성호
    • 센서학회지
    • /
    • 제29권2호
    • /
    • pp.128-132
    • /
    • 2020
  • Total organic carbon (TOC) analysis equipment, which was previously used to prevent eutrophication in advance, is heavy, bulky, and expensive; therefore, so it is difficult to be carried and has been used as an experimental unit. In this study, a through-carbon analysis chip that integrates pretreatment through photocatalytic oxidation and carbon dioxide measurement using a pH indicator was investigated. Both the total carbon - inorganic carbon method and the nonpurgeable organic carbon (NPOC) measurement method require an acidification part for injecting an acid solution for inorganic carbon measurement and removal, an oxidation part for total carbon or NPOC oxidation and a measurement part for Carbon dioxide (CO2) measurement. Among them, the measurement of oxidation and CO2 requires physical technology. The proposed TOC analysis chip decomposed into CO2 as a result of the oxidizing of organic carbon using a photocatalyst, and the pH indicator that was changed by the generated CO2 was optically measured. Although the area of the sample of the oxidation part and the pH indicator of the measurement part were distinguished in an enclosed space, CO2 was quantified by producing an oxidation part and a measurement part that shared the same air in one chip. The proposed TOC analysis chip is less expensive and smaller, cost and size are disadvantages of existing organic carbon analysis equipment, because it does not require a separate carrier gas to transport the CO2 gas in the oxidation part to the measurement part.

도서관에 적용가능한 정보불평등 측정지표 개발 연구 (A Study on the Development of Information Inequality Measurement Indicator Optimized for the Library)

  • 노영희;장로사
    • 정보관리학회지
    • /
    • 제36권4호
    • /
    • pp.53-81
    • /
    • 2019
  • IFLA의 UN 2030 Agenda, 도서관정보정책위원회의 제3차 도서관발전종합계획(2019-2023)에서 사회적 포용을 실천하는 도서관의 역할을 강조함에 따라 최근 국내외를 막론하고 정보불평등을 해소하기 위한 공공서비스기관으로서 도서관이 새롭게 조명되고 있다. 이에 본 연구에서는 도서관에 적합한 정보불평등 측정지표를 개발하였으며, 이를 위해 전문가 집단의 검증단계로서 FGI 및 델파이기법을 실시하였다. 그 결과, 최종지표는 총 3개의 평가영역, 총 12개의 평가항목, 총 30개의 평가지표로 도출되었다. 구체적으로 첫째, 접근 평가영역에서는 3개의 평가항목, 8개의 평가지표가 도출되었으며, 둘째, 역량 평가영역에서는 5개의 평가항목, 12개의 평가지표가 도출되었고, 셋째, 활용 평가영역에서는 4개의 평가항목, 10개의 평가지표가 도출되었다. 본 연구는 현재 범지구적으로 도서관에 적용 가능한 정보불평등 측정지표가 전무한 상황에서 개발되었다는 점에서 무엇보다 그 의미와 가치가 클 것으로 사료된다.

지역보건 관련 소지역간 건강증진지표 개발에 관한 연구 (Development of Small Area Health Promotion Indicator for Community Health Initiative)

  • 김춘배;고광욱;박재성;최헌
    • 보건교육건강증진학회지
    • /
    • 제20권1호
    • /
    • pp.19-39
    • /
    • 2003
  • Purpose: Although there is a lot of secondary data available for comparing community health status and planning health policies in terms of large area such as metropolitan cities or provinces, there is restricted data for establishing community health policies of the small areas such as towns, Gun(i.e., districts), and Gu. Specifically, the problems of producing a valuable index for health promotion in small areas are three fold: First, there is not an appropriate index model for measuring a small community health status. Second, a large part of secondary data in the small areas has been produced in an irregular time interval. In addition, all valuable data can not be integrated without time consuming work. Thus this study tries to establish a health promotion index model for assisting community health promotion initiatives of local governments. Methods and materials: Literature review, community health specialist consultation and a questionnaire survey was performed. Results: Based on Dever's model, a prototype of health promotion indicators was proposed and modified by the community health specialists. 15 classification scheme of statistical yearbook reorganized into the six areas. Those six areas were comprised in 24 indicator class with 96 specific indicators. Through further modification processes by a questionnaire survey, we developed a health promotion indicator model that contains six areas with 23 indicator class encompassed by 87 specific indicators. Conclusions: This study proposed a model of health promotion indicator comprised in the six areas with 23 indicator classes for measuring small area health promotion status. However, more specific or additional data in human biology, environment, and socioeconomic data is essential for producing a stronger model for health promotion measurement.

문화재 보존시설에서의 습도지시카드 적용성 연구 (The Application of Humidity Indicators for Environmental Measurement Apparatus of Preservation Facility)

  • 임보아;신은정;도민환
    • 보존과학연구
    • /
    • 통권30호
    • /
    • pp.47-61
    • /
    • 2009
  • Cultural heritages are affected by various environmental factors. Main factors are temperature, humidity, light and indoor air pollutants such as ozone, nitrogen oxides. Especially humidity condition is very important. Low humidity condition can cause contraction and high humidity condition can lead to growth of microorganism. This study is conducted to appraise an applicability of the Humidity Indicator which is one of the simple method for humidity control. The Humidity Indicator shows the humidity conditions through color change. Therefore, photometer was used to correctly measure the color change of Humidity Indicator. As a result of lab test, Humidity Indicators was stabilized after one hour from en exposure in a certain humidity condition and the indicators indicated clear correlations between color changes of Humidity Indicators and humidity conditions. Some Humidity Indicators which had been selected through the lab tests were applied to preservation facilities of cultural heritages and the indicators indicated closed correlations with humidity conditions in indoor of facilities.

  • PDF

쓰레기 매립지 가스포집관에서 유출가스 계측에 관한 연구(1) -유량계 계측오차의 최소화를 위한 해석 - (A Study on the Measurement of Gas Discharge from the Gas Vent of Sanitary Landfill(1)- analysis for minimizing the measurement error of flow meter -)

  • 이해승;이찬기
    • 한국토양환경학회지
    • /
    • 제3권1호
    • /
    • pp.83-92
    • /
    • 1998
  • 본 연구는 가스 포집관을 설치한 쓰레기 매립지에서의 가스 유동에 따른 모델 해석으로 부터 다음의 결과를 얻었다. 1) 저항이 없는 유량 계측기의 오차는, 투기계수 $10^{-14}$ $m^{2}$(실트; 포화투수계수 $10^{-7}$ m/s)보다 작은 복토를 쓰고 가스 발생량을 계측한다면, \circled1 직경 l0m 내에서는 0.5 mL/s 이상, \circled2 직경 20m 내에서는 2mL/s 이상, \circled3 직경 50m 내에서는 10 mL/s 이상의 유량범위에서, 정확한 계측치를 얻을 수 있다. 2)복토층의 \circled1투기계수가 $10^{-16}$$m^{2}$(점토; 포화투수계수 $10^{-9}$( m/s)에서는, 3종(bubblemeter, water head indicator and rotor meter)의 유량 계측기 모두 50m까지 유효한 계측이 가능하다. \circled2투기계수가 1$10^{-14}$$m^{2}$에서는, bubble meter and water head indicator는 5m 이하, rotor meter는 15m 내의 범위에서 유효한 계측이 가능하다. \circled3투기계수가 $10^{12}$$m^{2}$에서는 가스 포집관의 2m범위 이내에서만 유효히 계측된다. 3) 가스 포집관에 유량 계측기를 설치하면, 계측조건의 변화로 정상조건까지의 도달시간은 bubble meter와 water head indicator는 약 1일, roter meter는 약 1시간 정도가 소요된다.

  • PDF