• Title/Summary/Keyword: measurement feedback

Search Result 466, Processing Time 0.022 seconds

Real-time Feedback Vibration Control of Structures Using Wireless Acceleration Sensor System - System Design and Basic Performance Evaluation - (무선 가속도센서 시스템을 이용한 건축물의 실시간 피드백 진동제어 - 시스템 구축 및 기초성능 평가 -)

  • Jeon, Joon Ryong;Park, Ki Tae;Lee, Chin Ok;Heo, Gwang Hee;Lee, Woo Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.21-32
    • /
    • 2013
  • This is a preliminary study for the real-time feedback vibration control of building structures. The study developed a wireless acceleration sensor system based on authentic technology capacities, to integrate with the Prototype AMD system and ultimately construct the feedback vibration control system. These systems were used to evaluate the basic performance levels of the control systems within model building structures. For this purpose, the study first developed a wireless acceleration sensor unit that integrates an MEMS sensor device and bluetooth communication module. Also, the study developed an operating program that enables control output based on real-time acceleration response measurement and control law. Furthermore, the Prototype AMD and motor driver system were constructed to be maneuvered by the AC servo-motor. Eventually, all these compositions were used to evaluate the real-time feedback vibration control system of a 2-story model building, and qualitatively measure the extent of vibrational reduction of the target structure within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within 1st and 2nd resonance frequency as well as the random frequency of the model building structure. Ultimately, this study confirmed the potential of its wireless acceleration sensor system and AMD system as an effective tool that can be applied to the active vibration control of other structures.

The Effects of Ultrasound Imaging Visual Feedback During Toe-Spread-Out Exercise in Subjects With Hallux Valgus (엄지발가락가쪽휨증의 발가락벌리기 운동 시 초음파 영상을 이용한 시각적 피드백의 효과)

  • Kang, Sun-young;Choung, Sung-dae;Shim, Jae-hoon
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.21-28
    • /
    • 2016
  • Background: The toe-spread-out (TSO) exercise has been introduced as a strengthening exercise for the abductor hallucis muscle in subjects with hallux valgus. Visual biofeedback using ultrasound imaging during exercise, may increase the ability to selectively contract the abductor hallucis muscle, compared with exercise alone. Objects: The aim of this study was to investigate the effects of ultrasound imaging visual feedback during the TSO exercise with respect to its influence on the angle of the first metatarsophalangeal joint (1st MPJ) and the cross-sectional area (CSA) of the abductor hallucis muscle in subjects with hallux valgus. Methods: Twenty-five healthy young subjects with a mean average age of 22.5 years, and a standard deviation of 2.3 years, were recruited for this study. Hallux valgus was defined as an angles greater than $15^{\circ}$ angle of 1st MPJ. Goniometric measurement was used to determine the angle of 1st MPJ. In addition, an ultrasound system was used to collect the CSA of the abductor hallucis muscle in each foot. The angle of the 1st MPJ and CSA of the abductor hallucis were measured in three positions; the resting position, during TSO exercise, and during TSO exercise in conjunction with real-time ultrasound imaging feedback. All data analyzed using a repeated analysis of variance with Bonferroni correction in order to compare the dependent variables in all three positions. Statistical level of significance was set up as p<.05. Results: The angle of the 1st MPJ was noted to be significantly reduced and the CSA of the abductor hallucis to be significantly greater during TSO exercise used in conjunction with ultrasound imaging visual feedback, compared to when the values were recorded during TSO exercise alone (p<.05). Conclusion: Based on these findings, it can be concluded that the application of ultrasound imaging visual feedback during TSO exercise is more effective in contracting selectively the abductor hallucis than the use of exercise alone.

Development and Validation of the Measurement Tool of Public Benefits in Regional Cardiocerebrovascular Center (권역심뇌혈관질환센터의 공익성 측정도구 개발)

  • Lee, Kunsei;Shin, Eunyoung;Jeong, Hyoseon;Lee, Jung-Hyun;Kim, Hee-Sook;Lim, Young Sil;Kim, Young Taek
    • Health Policy and Management
    • /
    • v.23 no.4
    • /
    • pp.434-444
    • /
    • 2013
  • Background: Regional Cardiocerebrovascular Centers (RCC) were established for the prevention and treatment of cardiocerebrovascular disease and funded by the Ministry of Health and Welfare. The purpose of this study was to develop and validate the measurement tool of public benefits in RCC. Methods: Through the intensive literature review, experts surveys and their repetitive feedback, we selected the 46 items about the public benefits in RCC. Development of measurement tool involved content validity test using Content Validity Index (CVI), construct validity test through factor analysis and reliability test. Results: Thirty-five items were selected by content validity test, which CVI was 0.08 or higher. Through the construct validity test, 32 items in 7 factors were derived. And Cronbach's alpha was 0.951. Finally, public benefits measurement tool is composed of 32 items in 7 factors which are comprehensiveness of health care services, market complement, emergency care, cost, governance, quality improvement, and government control. Conclusion: Though we developed the measurement tool of public benefits in RCC, it would be utilized to measure the public benefits of various health agencies.

Underwater Hybrid Navigation System Based on an Inertial Sensor and a Doppler Velocity Log Using Indirect Feedback Kalman Filter (간접 되먹임 필터를 이용한 관성센서 및 초음파 속도센서 기반의 수중 복합항법 시스템)

  • Lee, Chong-Moo;Lee, Pan-Mook;Seong, Woo-Jae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.149-156
    • /
    • 2003
  • This paper presents an underwater hybrid navigation system for a semi-autonomous underwater vehicle (SAUV). The navigation system consists of an inertial measurement unit (IMU), an ultra-short baseline (USBL) acoustic navigation sensor and a doppler velocity log (DVL) accompanying a magnetic compass. The errors of inertial measurement units increase with time due to the bias errors of gyros and accelerometers. A navigational system model is derived to include the error model of the USBL acoustic navigation sensor and the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 25 in the order. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors and correct the state equation when the measurements are available. Simulation was performed with the 6-d.o.f. equations of motion of SAUV in a lawn-mowing survey mode. The hybrid underwater navigation system shows good tracking performance by updating the error covariance and correcting the system's states with the measurement errors from a DVL, a magnetic compass and a depth senor. The error of the estimated position still slowly drifts in horizontal plane about 3.5m for 500 seconds, which could be eliminated with the help of additional USBL information.

  • PDF

Design and Implementation of the u-Health Care Services in the Life Environment (생활환경 기반 u-건강관리서비스 설계 및 구현)

  • Hong, In-Hwa;Kim, Ju-Young;Choi, Ho-Chun;Kim, Chan-Gyu;Jung, Kwang-Mo;Kim, Nam-Il;Kang, Jeong-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.107-118
    • /
    • 2011
  • This paper shows a u-Health management system in user's Life environment, which is different from previous ones by enterprises. It's designed for users(citizens) and service provider(especially providing medical service). This paper is discussing on the proof on the service model being operated near the Tancheon stream in the city of Sung-nam. To maximize users' satisfaction, this service has been designed on four disciplines(so easy, so simple, well-customized, funny feedback) in the viewpoint for users. Its algorithm has 4 levels which are measurement, prescription, monitoring and feedback. In the system. there are HCBs(health check boothes) checking out status and assessment of users, customized health prescription customized a health management service prescription engine, exercise programs customized on exercise equipments near the stream and monitoring system.

Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode (전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구)

  • Yi, Kye-Hyoung;Park, Sung-Bin;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.

Development of Error Compensation System and On the Machine Measurement System for Ultra-Precision Machine (초정밀가공기용 오차보상시스템 및 기상측정장치 개발)

  • 이대희;나혁민;오창진;김호상;민흥기;김민기;임경진;김태형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.599-603
    • /
    • 2003
  • This paper present an error compensation system and On-Machine Measurement(OMM) system for improving the machining accuracy of ultra-precision lathe. The Fast-Tool-Servo(FTS) driven by a piezoelectric actuator is applied for error compensation system. The controller is implemented on the 32bit DSP for feedback control of piezoelectric actuator. The control system is designed to compensates three kinds of machining errors such as the straightness error of X-axis slide, the thermal growth error of the spindle. and the squareness between spindle and X-axis slide. OMM is preposed to measure the finished profile of workpiece on the machine-tool using capacitive sensor with highly accurate ruby tip probe guided by air bearing. The data acquisition system is linked to the CNC controller to get the position of each axis in real-time. Through the experiments, it is founded that the thermal growth of spindle and tile squareness error between spindle and X-axis slide influenced to machining error more than straightness error of X-axis slide in small travel length. These errors were simulated as a sinusoidal signal which has very low frequency and the FTS could compensate the signal less than 30 m. The implemented OMM system has been tested by measuring flat surface of 50 mm diameter and shows measurement error less than 400 mm

  • PDF

Development of Contact Force Measurement Algorithm for a 3D Printing-type Flexible Tactile Sensor (3D 프린팅 방식 유연 촉각센서의 접촉력 측정 알고리즘 개발)

  • Jeong, Kyeong-Hwa;Lee, Ju-Kyoung;Lee, Suk;Lee, Kyung-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.583-588
    • /
    • 2015
  • Flexible tactile sensors can provide valuable feedback to intelligent robots regarding the environment around them. This is especially important when robots such as, service robots share a workspace with humans. This paper presents a contact force measurement algorithm of a flexible tactile sensor. This sensor is manufactured by a direct-writing technique, which is one 3D printing method, using multi-walled carbon nano-tubes. An analog signal processing circuit has been designed and implemented to reduce noise contained in the sensor output. In addition, a digital version of the Butterworth filter was implemented by software running on a microcontroller. Through various experiments, characteristics of the sensor system have been identified. Based on three traits, an algorithm to detect the contact and measure the contact force has been developed. The entire system showed a promising prospect to detect the contact over a large and curved area.

A/F Control of an MPI Engine on Transient Conditions with an Intergration type Ultrasonic Flow Meter (적분형 초음파 유량계를 이용한 MPI 엔진의 비정상상태 공연비 제어)

  • 김중일;장준석;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.36-47
    • /
    • 1999
  • Three-way catalyst converter, cleaning up the exhaust gas contamination of SI engine, has the best efficiency when A/F ratio is near the stoichiometry . The feedback control using oxygen sensors in the exhaust manifold has limits caused by the system delays. So the accurate measurement of air flow rate to an engine is essential to control the fuel injection rate especially on transient condition like the rapid throttle opening and closing. To measure the rapid change of flow rates. the air flow meter for the engine requires quick response, flow reversal detection, and linearity . Tjhe proposed integration type air flow meter (IFM), composed of an ultrasonic flow meter with an integration circuit, has significantly improved the measurement accuracy of air mass inducted through the throttle body. The proposed control method estimated the air mass at the cylinder port using the measured air mass at the throttle . For the fuel dynamic model, the two constant fuel model is introduced . The control parameters from air and fuel dynamics are tuned to minimize the excursion of the air fuel ratio. As a result A/F ratio excursion can be reduced within 5% when throttle rapidly opens and closes at the various engine conditions.

  • PDF

Design and DSP-based Implementation of Robust Nonlinear Speed Control of Permanent Magnet Synchronous Motor (영구자석 동기전동기의 강인 비선형 속도제어기의 설계 및 DSP에 기반한 구현)

  • 백인철;김경화;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 1999
  • A design and DSP-based implementation of robust nonlinear speed control of a permanent magnet synchronous motor(PMSM) under the unknown parameter variations and speed measurement error is presented. The model reference adaptive system(MRAS) based adaptation mechanisms for the estimation of slowly varying parameters are derived using the MIT rule. For the disturbances or quickly varying parameters, a quasilinearized and decoupled model which includes the influence of parameter variations and speed measurement error on the nonlinear speed control of a PMSM is derived. Based on this model, a boundary layer integral sliding mode controller to improve the robustness and performance of the nonlinear speed control of a PMSM is designed and compared with the conventional controller which employs Proportional plus Derivative(PD) control. To show the validity of the proposed scheme, simulations and DSP-based experimental works are carried out and compared with the conventional control scheme.