• Title/Summary/Keyword: measurement Noise

Search Result 3,228, Processing Time 0.038 seconds

Study on the Noise Reduction in the Rotary Compressor using BLDC Motor (BLDC 모터를 적용한 로터리 컴프레서 소음 저감에 관한 연구)

  • Kim, Jin-Soo;Lim, Kyung-Nae;Ku, Se-Jin;Lee, Jang-Woo;Jeon, Si-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.674-681
    • /
    • 2008
  • The main noise source of the BLDC rotary compressor for air conditioner was analyzed by using the measurement of noise and vibration, noise contour, and experimental modal analysis. The source is presumed to the mechanical resonance excited by the electromagnetic attractive force of the BLDC motor. To reduce the excessive noise of the BLDC rotary compressor due to the mechanical resonance, air-gap was enlarged. Its validation was conducted by the analysis of the electromagnetic attractive force which is generated by the BLDC motor. By enlarging the length of air-gap, the noise in the compressor and air conditioner was significantly improved by 2.5dB(A) and 4.5dB(A), respectively.

  • PDF

Influence of Exposed Aggregate Texturing on the Reducing Traffic Noise Emission

  • Han-Young, Moon;Sang-Wook, Ha;Eun-Cheol, Yang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1067-1070
    • /
    • 2003
  • The effects of traffic noise are a serious concern in many urban communities throughout the world. Environmental noise at high intensities directly affects human health by causing hearing loss and indirectly affects human welfare by interfering with sleep, thought, and conversation. In general, portland cement concrete(PCC) pavement is known to create more noise than asphaltic surfaces though it has the advantage of durability and superior surface. However, the results of preliminary laboratory test showed exposed aggregate concrete(EAC) have an effect on reducing traffic noise. Based on the laboratory test, pilot construction of exposed aggregate concrete was performed and series of in-situ measurements were conducted for noise analysis which included the pass-by noise measurement and the close-proximity method. Conclusively, It is expected that tire/pavement noise which is represented much noise levels at higher frequencies would be significantly reduced on special textures of pavement as like exposed aggregate concrete.

  • PDF

A Study on Radiation Characteristic for Railway Noise (철도소음의 방사특성에 관한 연구)

  • Kim, Jae-Chul;Moon, Kyeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.531-536
    • /
    • 2003
  • In order to control the railway noise. we should know the radiation characteristic of the noise during the train passage Generally, the railway noise sources for conventional trains are classified by the rolling noise and power unit noise in tangent track. In this Paper. we describe on a train model that is considered to be a row of point sources to calculate the radiation characteristic The calculation results are compared with short distance measurement of three kinds of trains (EMU, Mookungwha, Saemaul). It is shown that the radiation characteristic of the rolling noise that is major noise source of electric multiple unit is dipole type. We know that characteristic of the engine noise is radiated as the cosine type.

An Study for Noise Effects by the Power Plant (발전소 발생소음에 대한 영향 분석)

  • Lee, Wook-Ryun;Kim, Hee-Soo;Kim, Dong-Whan;Bae, Yong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.513-517
    • /
    • 2014
  • In this paper, I summarize the case for the noise emission of domestic power plants and foreign power plants occurred recently. It is described to main content that is analyzing of the noise source and looking at the noise generated, if necessary to derive the solution. In addition, a case study is shown based on that noise levels can be changed by the differently surrounding environmental conditions during the measurement noise.

  • PDF

Noise Source Identification and Design Changes for Noise Reduction of a Fork-Lift Truck (지게차 소음원 규명 및 소음 저감)

  • 송세철;전범석;김원명;김형근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.557-563
    • /
    • 1997
  • In order to satisfy the regulations concerned with the noise emission of fork-lift trucks and thereby increase export to the western countries, a noise reduction technique should be developed in the early design stage. In this paper, several noise sources are identified using the sound suppression method and sound intensity measurement, and their contributions to the sound levels at the operator's ears and at the distance of 7m from the vehicle are studied. For each of the major noise producting components, noise abatement alternative are suggested and their effects are analyzed.

  • PDF

Development of an Index for the Evaluation of Intake Booming Noise of a Passenger Car (차량의 흡기부밍소음 평가지수 개발)

  • Park Y. W.;Chai J. B.;Jang H. K.;Lee J. K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.884-890
    • /
    • 2004
  • In this paper, an index for the evaluation of vehicle intake booming noise is developed through a correlation analysis of objective measurement data and subjective evaluation data. First, intake orifice noise is measured at the wide-open test condition. And then, acoustic transfer function between intake orifice noise and interior noise at the steady state condition is estimated. Simultaneously, subjective evaluation was carried out with a ten-scale score by 8 engineers. Next, the correlation analysis between the psycho-acoustic parameters derived from the measured data and the subjective evaluation is performed. The most critical factor was determined and the corresponding index for the intake booming noise is obtained from the multiple factor regression method. At last, the effectiveness of the proposed index is validated.

Uncertainty in the Calibration of Coaxal Thermal Noise Sources using a Noise Figure Measuring Equipment

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.79-86
    • /
    • 2004
  • In this paper, the uncertainty in the calibration of coaxial thermal noise sources using a noise figure measuring (NFM) equipment is evaluated. Contributions to the uncertainty such as the calibration uncertainty of the standard noise source, mismatch, measurement of adapter efficiency, ambient temperature variation, and repeatability are evaluated in the frequency range of 10 MHz to 18 ㎓. Results show that the expanded uncertainty(k=2) is 0.23 ㏈ for the noise sources of 5 ㏈ and 15 ㏈ ENR, and 0.27 ㏈ for those of 21 ㏈.

ENVIRONMENTAL NOISE POLICIES AND NOISE CONTROL PRACTICE IN CHINA

  • Tian, Jing
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.25-32
    • /
    • 2005
  • In China, environmental noise policies are composed of correlated laws adopted by the Standing Committee of the National People's Congress and promulgated by the President of the country, regulations promulgated by the State Council and/or local government, standards issued by the Standardization Administration Committee (SAC) under the State Council. The laws mainly include the 'Environmental Protection Law' and the 'Law on Prevention and Control of Pollution From Environmental Noise' Regulations are often applied to a special noise pollution phenomenon of wide influence. They are generally only effective in a given area and/or a specific period. Tens of correlated standards specify the noise level limits of different functional zones of land use and of different equipment, machines, devices, appliances etc., and the measurement methods. In this presentation, a brief introduction to these policies and their operations is given and discussed. The conclusion is that the policies supply an effective legislative basis for environmental noise prevention and control in China, but still a lot of work should be conducted and completed to strive for a quiet society.

  • PDF

A Study on Silencer Performance Assessment under Onboard Condition (선내 탑재된 소음기 성능평가 방법에 관한 연구)

  • Lee, Do-Kyung;Jin, Bong-Man;Lee, Cheul-Won;Kim, Nho-Sung;Choi, Su-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.731-736
    • /
    • 2004
  • The exhaust noise of auxiliary engine in ships is directly transmitted to bridge wing with only distance attenuation. It is not easy to find out practical treatment to be applied between exhaust pipe and bridge wing to reduce the transmission of the exhaust noise. In general, therefore, a silencer is fitted to reduce the exhaust noise and correspondingly noise of bridge wing. The silencer should be properly designed under the consideration of the frequency component of the exhaust noise and the required performance such as noise reduction or insertion loss. In general, the gas inside the exhaust pipe flows with high temperature and speed and thus onboard test condition is more adverse than the standard atmospheric condition. In this study, the test method to evaluate silencer performance using a probe microphone is introduced.

  • PDF

Actual Noise Condition of the Subway Station in Gwang-ju City (광주광역시 지하철 소음실태 조사연구)

  • Kim, Heung-Sik;Park, Gi-Pyo;Shin, Seung-Hun;Lee, Min-Tae;Moon, Gyeong-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.934-937
    • /
    • 2004
  • The purpose of this study is to present a fundamental data to get the noise reduction method of subway station in Gwang-ju city. Subway noise level measurement and questionnaire on the satisfaction of sound condition were carried out. The results show that the noise level of the subway station and the noise reduction effect installed by screen door is over 10 dB(A).

  • PDF