• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.046 seconds

A Process Optimization of HVOF on ALBC3 by Experiments Design (실험계획법을 이용한 ALBC3에 대한 고속화염용사의 최적 공정 설계)

  • Kim, Young-Moon;Lim, Byung-Chul;Kim, Min-Tae;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.448-453
    • /
    • 2016
  • Erosion and abrasion caused by cavitation damage occur in fluid equipment, such as ships or impellers. Similarly, the equipment damage from noise and vibration can shorten its life. This study analyzed the importance of the parameter characteristics of the process optimization of HVOF (High Velocity Oxygen Fuel spraying), which is generally used in a variety of industries for enhancing the resistibility from the cavitation phenomenon. The surface of the ALBC3 substrate was coated with an amorphous powder as a filler metal according to the experimental design using the Taguchi method, and then the characteristics with each parameter were analyzed using a porosity measurement test. The optimal process conditions was a combustion pressure of 80psi, coating distance of 270mm, gun speed of 200mm/s, and powder feed rate of 25g/min as a result of the HVOF coating by applying the experimental design. The combustion pressure, coating distance and powder feed rate were more than 25% and indicated a similar contribution rate, but the contribution rate of the gun speed was 19%, which was slightly less than the others. The contribution rate with each parameter was only slightly significant. On the other hand, all four parameters were found to be important in the contribution rate aspects of the HVOF coating process.

An Experimental Study on the Fire Monitoring System for Tunnel Using SMA and Fiber Optic Cable (형상기억합금과 광케이블을 이용한 터널의 화재감지 시스템 개발에 관한 실험적 연구)

  • Hwang, Ji-Hyun;Park, Ki-Tae;Lee, Kyu-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.128-134
    • /
    • 2014
  • Recently, design and construction of street tunnels tend to focus on cost reduction and preservation of nature. Accordingly, research is actively being carried out to quickly detect fires when they occur in tunnels, which have partially closed structures. Among such research, fire detection methods using optical fiber sensors have a wide bandwidth and fast transmission speed, while using light as a medium. Therefore, it does not receive electrical interference and there is almost no loss of information during transmission, while also having little noise as well. In relation to this, a fire monitoring system that can accurately detect the location of fires in real time using shape memory alloy and optical cables was developed in this study. In order to verify the developed method, light loss measurement test was conducted according to indoor temperature changes, while also conducting fire simulation tests by installing test beds in common underground zones with different external environments of temperature and distance. Upon carrying out experiments, the fire monitoring system developed in this study was found to be able to detect fires in long distance sections in real time.

Development of an On-line Measurement Method for Clean Biofuel Based on Near Infrared Spectroscopy and Chemometrics (근적외선 분광학과 화학계량학에 기반한 청정 바이오연료 실시간 품질 측정 기술 개발)

  • Cho, Hyeong-Su;Ryu, Jun-Hyung;Liu, J. Jay
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.215-224
    • /
    • 2011
  • It is an important issue to develop quality assessing system for biofuel for the purpose of accelerating the mass production of biofuel. It is particularly challenging to conduct testing method in the mass production of bioethanol while meeting quality specifications such as ASTM (American Society for Testing & Materials) D4806-10. In order to address this challenge, this paper proposes on-line spectroscopic quality assesment system based on Near Infrared spectrum and Partial Least Squares method in Chemometrics. As a result of testing a number of preprocessing methods and Partial Least Squares, it was found out that Savitzky-Golay method showed the best performance in terms of spectrum correction, noise reduction, and model maintenance. The proposed system allows us to assess multiple quality components continuously using spectroscopic facilities with the cheap cost. Since the value of R2 is more than 0.99, it is possible to replace the laboratory analysis.

Disease Classification using Random Subspace Method based on Gene Interaction Information and mRMR Filter (유전자 상호작용 정보와 mRMR 필터 기반의 Random Subspace Method를 이용한 질병 진단)

  • Choi, Sun-Wook;Lee, Chong-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • With the advent of DNA microarray technologies, researches for disease diagnosis has been actively in progress. In typical experiments using microarray data, problems such as the large number of genes and the relatively small number of samples, the inherent measurement noise and the heterogeneity across different samples are the cause of the performance decrease. To overcome these problems, a new method using functional modules (e.g. signaling pathways) used as markers was proposed. They use the method using an activity of pathway summarizing values of a member gene's expression values. It showed better classification performance than the existing methods based on individual genes. The activity calculation, however, used in the method has some drawbacks such as a correlation between individual genes and each phenotype is ignored and characteristics of individual genes are removed. In this paper, we propose a method based on the ensemble classifier. It makes weak classifiers based on feature vectors using subsets of genes in selected pathways, and then infers the final classification result by combining the results of each weak classifier. In this process, we improved the performance by minimize the search space through a filtering process using gene-gene interaction information and the mRMR filter. We applied the proposed method to a classifying the lung cancer, it showed competitive classification performance compared to existing methods.

Dynamic Pyroelectric Properties of The $Pb(Zr_{0.9}Ti_{0.1})O_3$ Ceramics ($Pb(Zr_{0.9}Ti_{0.1})O_3$ 세라믹 Dynamic 초전특성에 관한 연구)

  • Min, Kyung-Jin;Kang, Seong-Jun;Chang, Dong-Hoon;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.28-34
    • /
    • 2000
  • Pyroelectric properties of the $Pb(Zr_{0.9}Ti_{0.1})O_3$ ceramics having the rhombohedral structure have been studied by using the dynamic measurement method. The pyroelectric responses of the $Pb(Zr_{0.9}Ti_{0.1})O_3$ ceramics are characterized in both low and high medulation frequency regions and their frequency depences are observed. In the low frequency region (2~200Hz), the change of polarization increases and shows the maximum since the reorientation rate of domains is higher than the modulation frequency. Inthe high frequency region (200~2000Hz), the pyroelectrci response decreases as the frequency increases, because the reorientation of domains is suppressed and so the change of polarization decreases. Pyroelectric coefficient, figure of merit, noise equivalent power and detectivity of the $Pb(Zr_{0.9}Ti_{0.1})O_3$ ceramics are measured as $1.6{\times}10^{-8}C/cm^2{\cdot},\;1.6{\times}10^{-11}C{\cdot}cm/J,\;2.4{\times}10^{-7}W/Hz^{1/2}\;and\;4.17{\times}10^6cm{\cdot}Hz^{1/2}/W$, respectively.

  • PDF

Near-Infrared Imaging Spectrometer onboard NEXTSat-1

  • Jeong, Woong-Seob;Lee, Dae Hee;Moon, Bongkon;Park, Kwijong;Park, Sung-Joon;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Kim, Mingyu;Lee, Duk-Hang;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.70.1-70.1
    • /
    • 2013
  • New space program for "Next-Generation Small Satellite (NEXTSat)" launched last year after the success of the series of Science & Technology Satellite (STSAT). KASI proposed the near-infrared imaging spectrometer as a scientific payload onboard NEXTSat-1. It was selected as one of two scientific payloads. The approved scientific payload is the near-infrared imaging spectrometer for the study of star formation history (NISS). The efficient near-infrared observation can be performed in space by evading the atmospheric emission as well as other thermal noise. The observation of cosmic near-infrared background enables us to reveal the early Universe in an indirect way through the measurement of absolute brightness and spatial fluctuation. The detection of near-infrared spectral lines in nearby galaxies, cluster of galaxies and star forming regions give us less biased information on the star formation. In addition, the NISS will be expected to demonstrate our technologies related to the development of the Korea's leading near-infrared instrument for the future large infrared telescope, SPICA.

  • PDF

Image Reconstruction Using Iterative Regularization Scheme Based on Residual Error in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 잔류오차 기반의 반복적 조정기법을 이용한 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.272-281
    • /
    • 2014
  • In electrical impedance tomography (EIT), modified Newton Raphson (mNR) method is widely used inverse algorithm for static image reconstruction due to its convergence speed and estimation accuracy. The unknown conductivity distribution is estimated iteratively by minimizing a cost functional such that the residual error namely the difference in measured and calculated voltages is reduced. Although, mNR method has good estimation performance, EIT inverse problem still suffers from ill-conditioned and ill-posedness nature. To mitigate the ill-posedness, generally, regularization methods are adopted. The inverse solution is highly dependent on the choice of regularization parameter. In most cases, the regularization parameter has a constant value and is chosen based on experience or trail and error approach. In situations, when the internal distribution changes or with high measurement noise, the solution does not get converged with the use of constant regularization parameter. Therefore, in this paper, in order to improve the image reconstruction performance, we propose a new scheme to determine the regularization parameter. The regularization parameter is computed based on residual error and updated every iteration. The proposed scheme is tested with numerical simulations and laboratory phantom experiments. The results show an improved reconstruction performance when using the proposed regularization scheme as compared to constant regularization scheme.

The Effect of Number of Echoes and Random Noise on T2 Relaxography : Development of 8-Echo CPMG (에코의 개수와 임의 잡음이 T2 이완영상의 구성에 미치는 영향연구 : 8에코 CPMG영상화 펄스열의 개발)

  • 정은기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The mapping of the spin-spin relaxation time T2 in pixel-by-pixel was suggested as a quantitative diagnostic tool in medicine. although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any mis-regitration of each pixels signal for the fitting of T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17-20 msec can give the reliable T2 map.

  • PDF

Manufacture and Evaluation of Reference Samples for Low Magnetic Moment (저자기 모멘트용 표준시료 제작 및 성능평가)

  • Park, I.W.;Hong, Y.S.;Kim, Y.M.;Yoon, H.;Lee, K.J.;Cho, S.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • We have manufactured and evaluated reference samples for the use of low magnetic moment measurements. Before the measurements, SQUID magnetometers were magnetically shielded from external magnetic noise. We considered the purity including magnetic impurities, the optimum thickness, the modification method, and the shape in the preparation of the samples. Three paramagnetic polycrystaline metal plates of Ti, W, and Al with the area of $4mm{\times}6mm$ were prepared finally. The magnetic moments of these three samples are measured very linear up to the field of 5 T without magnetic hysteresis. The temperature deviated ratios of the magnetic moments for Ti, Al, and W from 290 K to 310 K are 0.7, 1.5, and 0.1 %, respectively. The measured magnetic moments for Ti and W samples by our research team are very well agreeable with those by two SQUID magnetometers and a VSM at Quantum Design via international round robin test. The results suggest that the prepared reference samples are well suited for the use in the low magnetic moment measurement with SQUID based magnetometers.

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors (광섬유 센서를 이용한 경량전철 교량의 사용성 평가)

  • Kang, Dong-Hoon;Chung, Won-Seok;Kim, Hyun-Min;Yeo, In-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.305-312
    • /
    • 2007
  • Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.