• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.03 seconds

Analysis of a CubeSat Magnetic Cleanliness for the Space Science Mission (우주과학임무를 위한 큐브위성 자기장 청결도 분석)

  • Jo, Hye Jeong;Jin, Ho;Park, Hyeonhu;Kim, Khan-Hyuk;Jang, Yunho;Jo, Woohyun
    • Journal of Space Technology and Applications
    • /
    • v.2 no.1
    • /
    • pp.41-51
    • /
    • 2022
  • CubeSat is a satellite platform that is widely used not only for earth observation but also for space exploration. CubeSat is also used in magnetic field investigation missions to observe space physics phenomena with various shape configurations of magnetometer instrument unit. In case of magnetic field measurement, the magnetometer instrument should be far away from the satellite body to minimize the magnetic disturbances from satellites. But the accommodation setting of the magnetometer instrument is limited due to the volume constraint of small satellites like a CubeSat. In this paper, we investigated that the magnetic field interference generated by the cube satellite was analyzed how much it can affect the reliability of magnetic field measurement. For this analysis, we used a reaction wheel and Torque rods which have relatively high-power consumption as major noise sources. The magnetic dipole moment of these parts was derived by the data sheet of the manufacturer. We have been confirmed that the effect of the residual moment of the magnetic torque located in the middle of the 3U cube satellite can reach 36,000 nT from the outermost end of the body of the CubeSat in a space without an external magnetic field. In the case of accurate magnetic field measurements of less than 1 nT, we found that the magnetometer should be at least 0.6 m away from the CubeSat body. We expect that this analysis method will be an important role of a magnetic cleanliness analysis when designing a CubeSat to carry out a magnetic field measurement.

Design and Implementation of Biological Signal Measurement Algorithm for Remote Patient Monitoring based on IoT (IoT기반 원격환자모니터링을 위한 생체신호 측정 알고리즘 설계 및 구현)

  • Jung, Ae-Ran;You, Yong-Min;Lee, Sang-Joon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.6
    • /
    • pp.957-966
    • /
    • 2018
  • Recently, the demand for remote patient monitoring based on IoT has been increased due to aging population and an increase in single-person household. A non-contact biological signal measurement system using multiple IR-UWB radars for remote patient monitoring is proposed in this paper. To reduce error signals, a multilayer Subtraction algorithm is applied because when the background subtraction algorithm was applied to the biological signal processing, errors occurred such as voltage noise and staircase phenomenon. Therefore, a multilayer background subtraction algorithm is applied to reduce error occurrence. The multilayer background subtraction algorithm extracts the signal by calculating the amount of change between the previous clutter and the current clutter. In this study, the SVD algorithm is used. We applied the improved multilayer background subtraction algorithm to biological signal measurement and computed the respiration rate through Fast Fourier Transform (FFT). To verify the proposed system using IR-UWB radars and multilayer background subtraction algorithm, the respiration rate was measured. The validity of this study was verified by obtaining a precision of 97.36% as a result of a control experiment with Neulog's attachment type breathing apparatus. The implemented algorithm improves the inconvenience of the existing contact wearable method.

Outcome of Conservative Treatment for Patients with Disc Displacement of Temporomandibular Joint (측두하악관절 원판변위 환자의 보존적 치료결과)

  • Kim, Kyung-Hee;Kim, Ik-Hwan;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.305-318
    • /
    • 2007
  • To evaluate the treatment outcome after conservative treatment in patients with TMJ disc displacement which is the most common temporomandibular joint arthropathy, the subjects were chosen among the patients who presented to the Department of Oral Medicine of Pusan National University Hospital, diagnosed as TMDs and treated with conservative methods from 1994 to 2006 for 13 years. 88 patients with diagnosis of DD/cR and 60 patients with diagnosis of DD/sR were selected as the experimental group and 74 patients with diagnosis of masticatory muscle disorder (MMD) were selected as the control group. Subjective symptoms and clinical findings were investigated to evaluate and compare the subjects' status at the first visit and the last visit. The results were as follows; 1. Pain, noise, LOM and MCO measurements of DD/cR, DD/sR and MMD groups were markedly improved after conservative treatments including behavior therapy, physical therapy, medication and splint therapy. 2. At the first visit, high score of pain in MMD group, high score of noise and large MCO measurement in DD/cR group and high LOM score in DD/sR group were observed. At the last visit, high score of noise and increased MCO measurement in DD/cR group and high score of pain and LOM in DD/sR group were observed. 3. Among the patients who complained joint sound at their first visit, about 60% showed complete loss of joint sound after conservative treatment 4. DD/cR and DD/sR groups showed satisfactory outcomes after conservative treatments such as behavior therapy, physical therapy, medication and splint therapy while MMD group showed similar treatment outcome irrespective of the treatment modality used. 5. There was no difference in treatment outcomes after conservative treatments when the subjects were classified and compared according to gender, age group and chronicity. 6. MMD showed satisfactory prognosis in 10 treatments in less than 6 months while DD showed favorable prognosis in 10-20 treatments for 6 months to 2 years.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF

A Study on Public Nuisance in Kwangju City (Survey on Air Pollution and Noise Level) (공해(公害)에 관(關)한 조사연구(調査硏究) -광주시(光州市)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 조사연구(調査硏究)-)

  • Chung, Yo-Han;Kim, Kil-Wng;Moon, Jae-Kyu;Jhoo, Heung-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 1972
  • During the period from June 1st 1971 to November 30 th 1971, studies on air pollution were made in Kwangju city. The city was divided into 6 areas; the downtown area, the semi-downtown area, the heavy traffic area, the commercial area, the residential area, the park area, 13 surveying sites were selected each representing the characteristics of the area. The Measurement methods which were used are described below. Sulfur oxides were measured by $PbO_2$ cylinder method, sulfur dioxides ($SO_2$) and carbon monoxide (CO) by the MSA & Kitakwa detector, dustfall by the Deposit gauge method, and the noise levels by the Kanomax soundlevel meter. The results obtained are as follows: 1. The mean value of sulfur oxides in Kwangju city was $1.16mg\;SO_3/day/100cm^2\;PbO_2$, ranging from $0.45mg\;SO_3/day/100cm^2\;PbO_2$ to $3.10mg\;SO_3/day/100cm^2\;PbO_2$. 2. The mean values of sulfur oxides according to its specific area in the city were $1.45mg\;SO_3/day/100cm^2\;PbO_2$ in heavy traffic area, 1.36 in downtown area, 1.23 in semi-downtown area, 1.11 in commercial area, 0.96 in residential area, and 1.07 in park area, respectively. 3. The average concentration of sulfur dioxide was 0.063 ppm from 2 to 5 P.M in Kwangju city. 4. The average concentrations of sulfur dioxides according to its specific area, from 2 to 5 P.M, in the city were 0.084 ppm in heavy traffic area & downtown area, 0.067 in commercial area, 0.053 in semi-downtown area, 0.052 in residential area, and 0.036 in park area. 5. The average concentration of carbon monoxide was 22.3 ppm from 2 to 5 P.M, in Kwangju city. 6. The average concentrations of carbon monoxide according to its specific area, from 2 to 5 P.M, in the city were 27.0 ppm in downtown area, 26.3 in semi-downtown area, 23.0 in heavy traffic area, 21.7 in commercial area, 20.0 in residential arera, and 17.6 in park area. 7. The mean value of dusifall in Kwangju city was $29.28ton/km^2/month$, ranging from $9.85ton/km^2/month$ to $66.34ton/km^2/month$. 8. The mean values of dustfall according to its specific area in the city were $50.37ton/km^2/month$ in semi-downtown area, 42.76 in heavy traffic area, 34.67 in downtown area, 17.77 in commercial area, 14.40 in park area, and 14.76 in residential area. 9. The mean values of the soluble dust in Kwangju city was $10.23ton/Km^2/month$ and that of the insoluble dust was $19.05ton/Km^2/month$. 10. The mean value of noise level in Kwangju city was 62 phon, ranging from 37 phon to 88 phon. 11. The mean values of noise level according to its specific area in the city were 76 phon in heavy traffic area, 67 in semi-downtown area, 64 in downtown area, 59 in commercial area, 52 in part area, and 50 in residential area.

  • PDF

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Evaluation of Usefulness of SPIO (Superparamagnetic iron oxide) Contrast Agent in MRCP (Magnetic resonance cholangiopancreatography) (자기공명 담도췌장조영술에서의 SPIO 조영제의 유용성 평가)

  • Hong, In-Sik;Lee, Hae-Kak;Cho, Jae-Hwan;Kim, Hyeon-Ju;Jang, Hyun-Cheol;Park, Cheol-Soo;Lee, Sun-Yeob;Goo, Eun-Hoe;Dong, Kyung-Rae;Cho, Moo-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of SPIO contrast agent in Magnetic Resonance Cholangiopancreatography (MRCP) by performing a quantitative comparative analysis in patients undergoing MRCP for gallbladder stones with and without oral injection of SPIO (Superparamagnetic iron oxide) contrast agent. The subjects were 36 patients undergoing MRCP for suspected gallbladder stones between January 2009 and February 2010 and they were divided into halves to compare the two groups of with and without SPIO agent. For each subject in both the injected and non-injected group, T2-weighted images on a 1.5T MR scanner were obtained, using both the breath-holding and respiratory-triggered methods, respectively. The following regions were measured; for breath-hold T2-weighted images, the measurement regions were located at the central part of the gallbladder, and the areas 15 mm away from its center, toward the front and back, respectively, which were chosen to include surrounding tissues, while for respiratory-triggered T2-weighted images, at the central part of the gallbladder, and segment 5 and 6 of liver. In a quantitative analysis, average signal to noise ratio (SNR) in each of regions of interest (ROI) for each group were calculated and then average contrast to noise ratio (CNR) in each of ROI were obtained by using the SNR in the gallbladder as the basis to compare and analyze the values between the two groups. The CNR were higher for the injected group in those regions.