• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.027 seconds

Performance Evaluation of Surface Textures on Concrete Pavement (콘크리트 거친면 마무리처리에 따른 공용성 평가)

  • Park, Kwon-Je;Mun, Jun-Beom;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.6 no.1 s.19
    • /
    • pp.1-11
    • /
    • 2004
  • This study tries to propose the most effective pavement texture method through the performance evaluation of variable texture methods. Noise 2$\sim$3dB is reduced in the section of uniform space 18m longitudinal tinning. This result is proved by comparing the magnitude of noise in two sections. The noise of 26mm longitudinal firming section is greater than that of 18mm section by 2$\sim$3dB(A). The skid resistances measured in all test section show the reasonable results. The roughness or all the test sections satisfies AASHTO roughness standard (PrI 16cm/km). The result or questionnaire survey about driving quality shows that the longitudinal tinning is the most effective method. As the result of a visual measurement, it is proved that the section applied uniform space 26mm longitudinal tinning and the general section applied uniform space 26mm transverse tinning could drain water effectively. As the result of analysis with the ranking method, the 18mm longitudinal tinning in selected as one of the most effective tinning methods. In addition, 26mm longitudinal tinning, random space transverse tinning, and transverse drag are selected in order.

  • PDF

Low Frequency Noise and It's Psychological Effects

  • Eom, Jin-Sup;Kim, Sook-Hee;Jung, Sung-Soo;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • Objective: This entire study has two parts. Study I aimed to develop a psychological assessment scale and the study II aimed to investigate the effects of LFN (low frequency noise) on the psychological responses in humans, using the scale developed in the study I. Background: LFN is known to have a negative impact on the functioning of humans. The negative impact of LFN can be categorized into two major areas of functioning of humans, physiological and psychological areas of functioning. The physiological impact can cause abnormalities in threshold, balancing and/or vestibular system, cardiovascular system and, hormone changes. Psychological functioning includes cognition, communication, mental health, and annoyance. Method: 182 college students participated in the study I in development of a psychological assessment scale and 42 paid volunteers participated in the study II to measure psychological responses. The LFN stimuli consisted of 12 different pure tones and 12 different 1 octave-band white noises and each stimulus had 4 different frequencies and 3 different sounds pressure levels. Results: We developed the psychological assessment scale consisting of 17 items with 3 dimensions of psychological responses (i.e., perceived physical, perceived physiological, and emotional responses). The main findings of LFN on the responses were as follows: 1. Perceived psychological responses showed a linear relation with SPL (sound pressure level), that is the higher the SPL is, the higher the negative psychological responses were. 2. Psychological responses showed quadric relations with SPL in general. 3. More negative responses at 31.5Hz LFN than those of 63 and 125Hz were reported, which is deemed to be caused by perceived vibration by 31.5Hz. 'Perceived vibration' at 31.5Hz than those of other frequencies of LFN is deemed to have amplified the negative psychological response. Consequently there found different effects of low frequency noise with different frequencies and intensity (SPL) on multiple psychological responses. Conclusion: Three dimensions of psychological responses drawn in regard to this study differed from others in the frequencies and SLP of LFN. Negative psychological responses are deemed to be differently affected by the frequency, SPL of the LFN and 'feel vibration' induced by the LFN. Application: The psychological scale from our study can be applied in quantitative psychological measurement of LFN at home or industrial environment. In addition, it can also help design systems to block LFN to provide optimal conditions if used the study outcome, .i.e., the relations between physical and psychological responses of LFN.

Robust Orientation Estimation Algorithm of Fingerprint Images (노이즈에 강인한 지문 융선의 방향 추출 알고리즘)

  • Lee, Sang-Hoon;Lee, Chul-Han;Choi, Kyoung-Taek;Kim, Jai-Hie
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.55-63
    • /
    • 2008
  • Ridge orientations of fingerprint image are crucial informations in many parts of fingerprint recognition such as enhancement, matching and classification. Therefore it is essential to extract the ridge orientations of image accurately because it directly affects the performance of the system. The two main properties of ridge orientation are 1) global characteristic(gradual change in whole part of fingerprint) and 2) local characteristic(abrupt change around core and delta points). When we only consider the local characteristic, estimated ridge orientations are well around singular points but not robust to noise. When the global characteristic is only considered, to estimate ridge orientation is robust to noise but cannot represent the orientation around singular points. In this paper, we propose a novel method for estimating ridge orientation which represents local characteristic specifically as well as be robust to noise. We reduce the noise caused by scar using iterative outlier rejection. We apply adaptive measurement resolution in each fingerprint area to estimate the ridge orientation around singular points accurately. We evaluate the performance of proposed method using synthetic fingerprint and FVC 2002 DB. We compare the accuracy of ridge orientation. The performance of fingerprint authentication system is evaluated using FVC 2002 DB.

Effective PPG Signal Processing Method for Detecting Emotional Stimulus (감성 자극 판단을 위한 효과적인 PPG 신호 처리 방법)

  • Oh, Dong-Gi;Min, Byung-Seok;Kwon, Sung-Oh;Kim, Hyun-Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.393-402
    • /
    • 2012
  • In this study, we propose a signal processing algorithm to measure the arousal level of a human subject using a PPG(Photoplethysmography) sensor. From the measured PPG signals, the arousal level is determined by PPI(Pulse to Pulse Interval) and discrete-time signal processing. We ran psychophysical experiments displaying visual stimuli on TV display while measuring PPG signal from a finger, where the nature landscape scenes were used for restorative effect, and the urban environments were used to stimulate the stress. However, the measured PPG signals may include noise due to subject movement and measurement error, which results in incorrect detections. In this paper, to mitigate the noise impact on stimulus detection, we propose a detecting algorithm using digital signal processing methods and statistics of measured signals. A filter is adopted to remove a high frequency noise and adaptively designed taking into account the statistics of the measured PPG signals. Moreover we employ a hysteresis method to reduce the distortion of PPI in decision of emotional. Via experiment, we show that the proposed scheme reduces signal noise and improves stimulus detection.

Effects on the Magnetic Property Changes due to the defect in the Nuclear Reactor Vessel Material Irradiated by Fast Neutron (고속 중성자 조사에 의한 원자로 용기재료내의 결함생성이 자기적 특성변화에 미치는 영향)

  • Jeong, Myeong-Mo;Kim, Gil-Su;Jang, Gi-Sang;Yu, Geun-Bae;Park, Deok-Geun;Kim, Gil-Mu;Yun, In-Seop;Hong, Chi-Yu
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1240-1244
    • /
    • 1999
  • In order to assess the effects on the magnetic properties due to the defect in the material irradiated by fast neutron ranging $10^0-10^{18}n/cm^2$, the magnetic properties such as maximum magnetic induction, coercivity, remanence, Barkhausen Noise Amplitude(BNA), Barkhausen Noise Energy(BNE) and hardness were measured. It is shown that the magnetic properties and hardness do not change by the fast neutron irradiation under $10^{17}n/cm^2$. Therefore, in this experiment, it is understood that the magnetic properties decrease by the increase of hardness. This measurement method can be used to evaluate the neutron irradiation embrittlement nondestructively since the magnetic properties and hardness do change by the neutron irradiation over $10^{17}n/cm^2$ consistently.

  • PDF

A comparative study of cavitation inception of naval ship's propeller using on-board noise and vibration signals (선체 부착 소음/진동 센서를 이용한 함정 추진기 캐비테이션 초생 분석 비교 연구)

  • Hongseok Jeong;Hanshin Seol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.243-249
    • /
    • 2023
  • The occurrence of cavitation on the propeller is directly linked to the naval ship's survivability, and it is necessary to design a propeller shape that delays the cavitation inception. However, the propeller cavitation can occur under various operating conditions, thus it is important to identify whether the propeller cavitation exists during operation as well as in the design phase. To this end, it is necessary to use noise or vibration signals on board to monitor the cavitation inception. In this study, a hydrophone and an accelerometer were installed on the ship hull right above the propeller to compare the performance of analyzing cavitation inception between acoustic and vibration signals. Also, a high speed camera was used to visually observe the occurrence of cavitation through an observation window. The measured results showed that the spectral shapes between acoustic and vibration signals were different, but the level increases at each frequency band and the overall level of the frequency band from 1 kHz to 10 kHz showed a similar tendency. The Detection of Envelope Modulation On Noise (DEMON) analysis also showed similar results for both acoustic and vibration signals, confirming that both hydrophones and accelerometers can be utilized in the analysis of cavitation inception.

Evaluation of Validity Thyroid Scintigraphy Using Parallel Hole Collimator (갑상샘 신티그래피 검사 시 평행다공형 조준기 적용의 유효성 평가)

  • Su-Young Park;Ji-Youn Kim;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2024
  • In this study, When acquisition thyroid scintigraphy images, a parallel hole collimator was applied, and the difference from the pinhole collimator was quantitatively analyzed under each image acquisition condition. Visual size, resolution, sensitivity, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were evaluated using thyroid phantom and point source. When comparing visual size, it was confirmed that an image similar to the size of the pinhole collimator could be obtained only when a magnification ratio of about 2.00 to 2.09 times when applying a parallel hole collimator. There was no tendency in FWHM(mm) measurement using a point source, and sensitivity was high in the parallel hole collimator. SNR and CNR were high when using a low magnification ratio, matrix size of 128×128, and a parallel hole collimator. In images of similar size to the naked eye, when the matrix size was the same, both SNR and CNR were high in the pinhole collimator. Therefore, when performing a thyroid scintigraphy test, if appropriate conditions are set according to the situation of each hospital and a parallel hole collimator is applied, it can be a good option in terms of equipment utilization and work efficiency.

Evaluation of Image Noise and Radiation Dose Analysis In Brain CT Using ASIR(Adaptive Statistical Iterative Reconstruction) (ASIR를 이용한 두부 CT의 영상 잡음 평가 및 피폭선량 분석)

  • Jang, Hyon-Chol;Kim, Kyeong-Keun;Cho, Jae-Hwan;Seo, Jeong-Min;Lee, Haeng-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study on head computed tomography scan corporate reorganization adaptive iteration algorithm using the statistical noise, and quality assessment, reduction of dose was evaluated. Head CT examinations do not apply ASIR group [A group], ASIR 50 applies a group [B group] were divided into examinations. B group of each 46.9 %, 48.2 %, 43.2 %, and 47.9 % the measured in the phantom research result of measurement of CT noise average were reduced more than A group in the central part (A) and peripheral unit (B, C, D). CT number was measured with the quantitive analytical method in the display-image quality evaluation and about noise was analyze. There was A group and difference which the image noise notes statistically between B. And A group was high so that the image noise could note than B group (31.87 HUs, 31.78 HUs, 26.6 HUs, 30.42 HU P<0.05). The score of the observer 1 of A group evaluated 73.17 on 74.2 at the result 80 half tone dot of evaluating by the qualitative evaluation method of the image by the bean curd clinical image evaluation table. And the score of the observer 1 of B group evaluated 71.77 on 72.47. There was no difference (P>0.05) noted statistically. And the inappropriate image was shown to the diagnosis. As to the exposure dose, by examination by applying ASIR 50 % there was no decline in quality of the image, 47.6 % could reduce the radiation dose. In conclusion, if ASIR is applied to the clinical part, it is considered with the dose written much more that examination is possible. And when examination, it is considered that it becomes the positive factor when the examiner determines.

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Optical Communication and Sensing Modules for Plastic Optical Fibers (고분자광섬유용 광통신 및 센서 모듈)

  • Park, Byung-Wook;Yoon, Do-Young;Kim, Dong-Shik
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.558-564
    • /
    • 2009
  • POF(Polymer optical fiber) offers advantages of lighter, inexpensive, and easier to use over GOF(glass optical fiber). Its higher transmission loss and low bandwidth, however, make it suitable only for short distance networking such as LAN. The polymer materials and its synthesis technology of low transmission loss and the broader application for flexible POF are the two of many critical areas to be investigated more. In the current study, low-noise POF modules are developed and optimized with a low noise amplifier and low cost LED of 650 nm. In order to demonstrate the dynamic characteristics of the POF module for optical communication and sensing, we have built an image transfer module, optical transmission speed measurement module, optical transceiver for RS-232, and sound-transfer module, and the signal characteristics of them are evaluated. It is found that the module can be readily used for a quick and simple measurement of optical transfer speed. With help of analog amplifier, LED, and PD, sound and image transfers through a maximum 60 m optical waveguide have been confirmed. Real-time data transfer was also demonstrated in PID control, which is thought to be valuable to industrial plant design and control.