• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.034 seconds

Evaluation on Accuracy of Noise Measurement Applications for iPhone 4 and iPhone 3Gs (아이폰 4 및 아이폰 3Gs의 소음측정 애플리케이션에 대한 정확도 평가)

  • Ma, Hye Ran;Park, Doo Yong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.24-28
    • /
    • 2013
  • This article evaluates the accuracy of noise measurements for 37 noise measurement applications for iPhone 4 and iPhone 3Gs. Noise levels were measured using simultaneously a precision sound level meter and iPhones installed noise measurement applications at the levels of 70 dB, 80 dB and 90 dB at 1,000 Hz. Measurement errors were estimated by subtracting two measurements between iPhone and sound level meter. It was found that measurement errors of 34 applications(89.2%) were greater than ${\pm}2$ dB which is the maximum allowable error range for the Type II sound level meter. It was only 4 applications that measurement errors lie within ${\pm}2$ dB error range. There was no significant differences among measurements with four iPhone 4s. However, there were significant differences between the measurements with iPhone 4 and iPhone 3Gs using the same application. It was due to the different hardware specifications such as microphone. Therefore, noise measurement applications, for example, which has to utilize hardware of the smartphone, should be programmed to identify hardware specifications and to adopt appropriate correction factors upon hardware specifications. In conclusion, it is necessary to check accuracy and validity before using the noise measurement applications for iPhones. Also, it was suggested that it should develop an evaluation guideline or protocol on accuracy testing for the measurement applications using a smartphone.

Measurement method for valve noise (밸브의 소음 측정 방법)

  • Lee, Y. B.;Yoon, B. R.;Kwon, H. S.;Park, K. A.;Yoo, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.433-438
    • /
    • 2001
  • Noise is one of the major environmental problems in human life. To reduce the noise emitted from the control valve it is necessary to develop the measurement method, measurement system, analysis method applicable to the field. In this study IEC and ISO standards were investigated and measurement method for the valve noise was proposed. Noise from the valve was measured in the reverberation room and sound power level was calculated. The sound power level increased as the flow rate and pressure difference increased. The noise characteristics are useful to predict valve noise for given conditions, to compare the performance of different valves and to develope low-noise valves.

  • PDF

Uncertainty evaluation in electrochemical noise resistance measurement (전기화학적 노이즈 저항 측정에서의 불확도 평가)

  • Kim, Jong Jip;Kang, Su Yeon
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

The Measurement of Firing Noise of K2 Rifle at Close Distance (근접 측정에 의한 K2 소총 사격음의 측정)

  • 이윤
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1123-1128
    • /
    • 2004
  • An experimental study on firing noise of K2 rifle was performed. Firing noises of K2 rifle were measured at close distance to rifle. Firing noise of K2 rifle which made in Korea, has not measured before. The measurement of firing noise at close distance is not simple, because the amplitude of firing noise is much bigger than the measuring limit of ordinary sound level meter even though it uses a signal attenuator. The measurement of firing noise at close distance is necessary for noise source positioning and for obtaining the sound power of K2 rifle. By this experimental study, the firing noise levels of K2 rifle at different positions are obtained and these data can be used to Predict the sound pressure level at any distance from muzzle of the rifle. Also these data can be used to calculate the threshold shift of gunner's ear.

Design and Analysis of a State Feedback Controller for a Chain of Integrators System under Measurement Noise (측정에러가 있는 적분기 시스템에서의 상태 궤환 제어기 설계 및 분석)

  • Youn, Jae-Seung;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.969-974
    • /
    • 2010
  • In this paper, we propose a fault-tolerant controller for compensating measurement noise of feedback sensor. Because control systems operate via feedback sensor's signal, the measurement noise in sensor's signal results in performance degradation or even system failure. Therefore, control systems often demand on compensating measurement noise. Our controller is equipped with a compensator in order to reject or reduce the effect of measurement noise in feedback information. Our proposed method is verified via simulation and experiment for a Ball and Beam system.

Design and Analysis of an Output Feedback Controller for a Chain of Integrators System Compensating Measurement Noise of Feedback Sensor (적분기 시스템에서 센서의 측정에러를 보상하는 출력 궤환 제어기 설계 및 분석)

  • Kim, Hyun-Do;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.4
    • /
    • pp.299-303
    • /
    • 2011
  • In this paper, we propose an output feedback controller for a chain of integrators system compensating measurement noise of feedback sensor. Measurement noise makes feedback signals distorted, and results in performance degradation or even system failure. Therefore, we need to design a robust controller to accommodate the possible measurement noise in the feedback information. Our controller is equipped with a gain-scaling factor to reject or minimize the effect of measurement noise in output feedback information. We give a theoretical analysis of the controlled system and illustrate the improved control performance via an example.

A Measurement and Analysis of Low Level Radiated-Noise Using Vertical Line Array (수직선배열을 이용한 저소음 함정음향 측정 및 분석기법)

  • Choi, Jae-Yong;Son, Kweon;Dho, Kyeong-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.55-64
    • /
    • 2003
  • Underwater acoustic noise measurement is an essential element for vulnerability assessment of modern naval platforms. But during the last few decades environmental conditions have drastically changed due to the gradually increasing sea ambient noise level and decreasing submarine radiated noise level. A real-time underwater acoustic measurement system with vertical line array is designed for the quiet submarine radiated noise assessment in challenging environment. This system has a constant directivity index in measurement frequency range and accurate tracking capability for the transmission loss compensation and navigation aids inside the submarine. This system has been validated at sea and used several times for the submarine noise measurement.

Wireless Lan System And Its Applying to the Environment Noise Mapping (무선 인터넷 시스템을 이용한 소음 오염도 측정)

  • 김흥섭;이상권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.286-289
    • /
    • 2002
  • This paper proposes wireless fan system as noise measurement system. It is easy to combine measurement system(Hardware) and analytic system(software) to the Wireless tan system. Thus wireless fan system can be applied to noise mapping system and noise monitoring system. This paper show noise measurement experiment and result using wireless lan system.

  • PDF

The effect of noise and doppler for range measurement of low orbit satellite using tone method (톤 방식을 사용한 저궤도 위성 거리 측정에서의 잡음과 도플러 영향 분석)

  • 김영완;박동철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.641-650
    • /
    • 2000
  • The effects of noise and doppler for low orbit satellite range measurement using tone method are represented in this paper. Also the optimal noise bandwidth of range signal detection circuit which is used for range measurement system of KOMPSAT is proposed. Based on the effects of satellite orbit parameters via the deduction of dynamic motion characteristics of low orbit satellite and signal to noise spectral density of range measurement signal, the effects of noise and doppler for range measurement system are analyzed. The effect of satellite link noise is decreased, but the effect for doppler is increased as the PLL noise bandwidth of range signal detection circuit is increased. The validation of analyzed effect is verified via comparison of measurement results of KOMPSAT's range measurement system and simulation results in environments of low orbit satellite.

  • PDF

Evaluation of Elevator Noise level of Apartment Houses through Vibration Measurement (진동측정을 통한 공동주택 엘리베이터 소음 레벨 평가)

  • Kang, Min-Woo;Song, Min-Jeong;Oh, Yang-Ki
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.641-654
    • /
    • 2018
  • Elevator noise in apartment houses is one of the factors which prevent the residents from quiet and comfortable life. The elevator noise measurement method [KS F ISO 16032] is introduced from the matching ISO standard, however, it has problems in the application to the actual measurement. To visualize the problems, measurements in an apartment house are conducted, which has been suffering from the elevator noise for a long time. The measurement itself is extremely difficult due to the low sound pressure level of elevator, which is lower than 35 dB (A), and the even higher background noise level. However the vibration levels measured at the same time are relatively less disturbing As a result of vibration measurement, it was found that the vibration is clearly measured on the wall, and presents a high correlation coefficient of over 0.8 with the noise levels measured This shows that the vibration level measured on the elevator walls may be rather reliable numbers than the elevator noise levels in the actual noisy condition of elevator halls and the vicinity.