• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.029 seconds

Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측)

  • Ahn, Byoung-Ha;Shim, Jae-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.

Application of Piezoelectric Smart Structures for Statistical Energy Analysis (압전 지능 구조물을 이용한 통계적 에너지 해석 기법)

  • 김재환;김정하;김재도
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Room Acoustic Measurement System Using Impulse Response (임펄스응답을 이용한 실내음향 측정 시스템)

    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.63-67
    • /
    • 1999
  • Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.

  • PDF

The Analysis of VHF/UHF PD and 3d-PD Pattern (3d-PD 패턴과 VHF/UHF PD 신호의 고찰)

  • Lim, Jang-Seob;Park, Yong-Sik;Park, Byoung-Ha;Han, Sok-Kyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.75-78
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Measurement Level Experimental Test Result of GNSS/IMU Sensors in Commercial Smartphones

  • Lee, Subin;Ji, Gun-Hoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.3
    • /
    • pp.273-284
    • /
    • 2020
  • The performance of Global Navigation Satellite System (GNSS) chipset and Inertial Measurement Unit (IMU) sensors embedded in smartphones for location-based services (LBS) is limited due to the economic reasons for their mass production. Therefore, it is necessary to efficiently process the output data of the smartphone's embedded sensors in order to derive the optimum navigation values and, as a previous step, output performance of smartphone embedded sensors needs to be verified. This paper analyzes the navigation performance of such devices by processing the raw measurements data output from smartphones. For this, up-to-dated versions of smartphones provided by Samsung (Galaxy s10e) and Xiaomi (Mi 8) are used in the test experiment to compare their performances and characteristics. The GNSS and IMU data are extracted and saved by using an open market application software (Geo++ RINEX Logger & Mobile MATLAB), and then analyzed in post-processing manner. For GNSS chipset, data is extracted from static environments and verified the position, Carrier-to-Noise (C/N0), Radio Frequency Interference (RFI) performance. For IMU sensor, the validity of navigation and various location-based-services is predicted by extracting, storing and analyzing data in static and dynamic environments.

Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment (유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Jee-Chul;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

Precise Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (Indirect force 측정 방법과 Pseudo-역행렬을 이용한 정밀한 Force 예측)

  • 심재술;안병하;하종훈;정현출
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.564-567
    • /
    • 1997
  • In the design of structure the forces acting on the structure are important parameter for noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. Thus it is necessary to find out indirect force evaluation method. In this paper forces have been measured with in-situ vibration responses and system information. Three existing techniques of indirect force measurement, viz. direct inverse, principal component analysis and regularization have been compared. It has been shown that multi-vibration responses are essential for the precise estimation of the forces. To satisfy those conditions, Rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It has also been obtained that relatively higher force is transmitted though three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate and is investigated the possibility of force evaluation of rotary compressor as a complex structure.

  • PDF

A Remote Measurement of Water Level Using Narrow-band Image Transmission (협대역 영상전송을 이용한 원격 수위 계측시스템)

  • Kim, Ki-Joong;Lee, Nam-Ki;Han, Young-Joon;Hahn, Hern-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.54-63
    • /
    • 2007
  • To measure water levels from remote cites using a narrowband channel, this paper developed a difference image based JPEG communication scheme and a water level measurement scheme using the sparsely sampled images in time domain. In the slave system located in the field, the images are compressed using JPEG after changed to difference images, among which in a period of data collection those showing larger changes are sampled and transmitted. To measure the water level from the images received in the master system which may contain noises caused by various sources, the averaging scheme and Gaussian filter are used to reduce the noise effects and the Y axis profile of an edge image is used to read the water level. Considering the wild condition of the field, a simplified camera calibration scheme is also introduced. The implemented slave system was installed at a river and its performance has been tested with the data collected for a month.

Construction of the Electrochemical Impedance Measurement System Using Fourier Transform (푸리에 변환을 이용한 전기화학적 임피던스 측정 시스템 제작)

  • Hwang, Eui-Jin;Oh, Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.713-719
    • /
    • 1991
  • Electrochemical impedance measurement system using Fourier transform was constructed in the range of the frequencies up to 100 kHz. This system consists of pseudo-random noise generator, specially designed potentiostat, fast data acquisition system, system controller, and computer interface. The performance of the constructed system was found to be almost same as the commercially available system using lock-in amplifier. Measuring time was significantly reduced because the minimum time for the measurement depended on one cycle of the lowest frequency used. It would be possible to study time-varying electrochemical impedance systems such as the initial stages of corrosion processes using this system.

  • PDF