• Title/Summary/Keyword: measurement & verification(M&V)

Search Result 21, Processing Time 0.027 seconds

Study on Economical M&V Methoodology for the Lighting Control System (조명제어시스템 경제적인 실적확인 기법 연구)

  • Choi, Kyung-Shik;Han, Seung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF

A Survey on the M&V to guarantee the energy saving performance of ESCO (ESCO 에너지절약 성과보증의 M&V 적용사례 분석)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • ESCO industry should guarantee the energy saving performance in response to changes of regulations ESCO. In this point, the application of the M&V is important task on energy saving performance. Therefore, we need to examine the contents of practice for the M&V in developed countries. Between energy user and ESCO, it is important to provide and measure the energy saving performance by guarantee of energy savings performance contracts. After 2013 ESCO business began focusing on guaranteed savings contracts. For this reason, we need to take M&V cases recommended from IPMVP and applied in United States and Japan. Therefore, we should be ready about M&V application for the real conditions of ESCO.

AC loss Measurement of Superconducting Power Cable (초전도 전력케이블의 교류손실 측정)

  • Hwang, Si-Dole;Hyun, Ok-Bae;Sohn, Song-Ho;Choi, Hyung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.524-526
    • /
    • 2005
  • As a research activity of the project of "Verification Test of Superconducting Power Cable", we measured the AC loss of a short length superconducting power cable. The rating and the length of the cable were 22.9kV, 1,250A and 2.2m. The voltage taps for measuring the AC loss were attached to both ends of the conductor of the superconducting cable. Through the voltage taps and a lock-in amplifier we measured the in-phase component of the voltage($V_x$) with the load current(I). The AC loss was measured by multiplying the in-phase component of the voltage($V_x$) by the load current(I). The value of the AC loss of the superconducting power cable was 1.18W/m/phase/kA at 77.3K, 1atm.

  • PDF

Three Axis Isotropic Field Strength Measuring Antenna (3축 등방성 전계강도 측정 안테나)

  • Choi, Suk-Hwan;Kim, Dong-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.9
    • /
    • pp.879-885
    • /
    • 2014
  • In this paper, we designed and fabricated wideband 3-axis isotropic antenna for the Electro-Magnetic Fields(EMFs) measurement. Each part of proposed 3-axis antenna has isotropic characteristics and arbitrary axis of proposed 3-axis antenna could be selectable using RF switch. Also, a resistor was inserted in each axis of proposed 3-axis antenna for improving antenna gain and noise suppression characteristics, and port impedance of each dipole antenna were matched by balun. For the performance verification of antenna, GTEM Cell which generates standard electromagnetic field was used for the derivation of antenna factor and receiver sensitivity. As a result, fabricated 3-axis isotropic antenna has receiver sensitivity of 0.12~4.2 mV/m and typical VSWR of 3.3:1 within a wide operation frequency range from 0.03 MHz to 3 GHz.