• Title/Summary/Keyword: measured method

Search Result 22,595, Processing Time 0.049 seconds

Comprision Study of Measure Method on Leveling (수준측량 측정방법의 비교연구)

  • Hwang, Jin-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • This paper measured some condition about differential height of two points for the comparison of measure by direct method and Geodimeter and trigonometric Leveling method. The research was compared relationship between the volue to get from three measure method and five measured man. The significance of between three measure method and five measured man has been investigated by analysis of two-way ANOVA. The result indicate that between five measured man show insignficance, and between the direct method and Geodeter method show signficance and between the direct method and trigonometric Leveling method show signficance but between the Geodeter method and trigonometric Leveling method, two method show insignficant. Therefore, when using Geodemeter leveling method and trigonometric Leveling method, you must keep particular attention when former two Leveling method about instrumental error, natural error, and personal error, two Leveling method using low precision leveling.

Analysis of Electrical Resistivity Characteristics of Concrete by Using Flat Electrode Method (평판접지 전극방법을 이용한 콘크리트의 전기비저항 특성 분석)

  • Park, Chang Seon;Park, Hae Won;Lee, Kang Hun;Jeong, Jin Hoon
    • International Journal of Highway Engineering
    • /
    • v.19 no.3
    • /
    • pp.57-63
    • /
    • 2017
  • PURPOSES : The pole electrode method damaged the concrete pavement on inserting the electrode into the pavement surface. This study examined the feasibility of the flat electrode method to observe the concrete pavement instead of the pole electrode method and analyzed the resistivity characteristics of the concrete by performing laboratory tests. METHODS : The resistivity of the concrete specimens manufactured with three different mixing ratios (38.50%, 39.50%, and 40.50%) were measured using the pole and flat electrode methods according to the concrete age (7 and 28 days) and electrode spacing (20 mm, 30 mm, and 40 mm). RESULTS :In both pole and flat electrode methods, the resistivity increased with increasing fine aggregate proportion regardless of the concrete age. The resistivity measured at a concrete age of 28 days was slightly larger than that measured at 7 days. In the case of a concrete age of 7 days, the resistivity measured by the flat electrode method was larger than that measured by the pole electrode method. The difference disappeared at 28 days. CONCLUSIONS :The results suggest that the flat electrode method can replace the pole electrode method because the resistivity measured by both methods was similar. Hence, the development of a technology to apply the flat electrode method to actual concrete pavement is necessary.

A hybrid inverse method for small scale parameter estimation of FG nanobeams

  • Darabi, A.;Vosoughi, Ali R.
    • Steel and Composite Structures
    • /
    • v.20 no.5
    • /
    • pp.1119-1131
    • /
    • 2016
  • As a first attempt, an inverse hybrid numerical method for small scale parameter estimation of functionally graded (FG) nanobeams using measured frequencies is presented. The governing equations are obtained with the Eringen's nonlocal elasticity assumptions and the first-order shear deformation theory (FSDT). The equations are discretized by using the differential quadrature method (DQM). The discretized equations are transferred from temporal domain to frequency domain and frequencies of the nanobeam are obtained. By applying random error to these frequencies, measured frequencies are generated. The measured frequencies are considered as input data and inversely, the small scale parameter of the beam is obtained by minimizing a defined functional. The functional is defined as root mean square error between the measured frequencies and calculated frequencies by the DQM. Then, the conjugate gradient (CG) optimization method is employed to minimize the functional and the small scale parameter is obtained. Efficiency, convergence and accuracy of the presented hybrid method for small scale parameter estimation of the beams for different applied random error, boundary conditions, length-to-thickness ratio and volume fraction coefficients are demonstrated.

Effect of Analytical Method on the Pharmacokinetic Evaluation of Bromosulfophthalein: Comparison of HPLC and UV Spectroscopy Method (Bromosulfophthalein의 체내동태 평가에 미치는 분석법의 영향: HPLC 법과 UV 흡광광도법의 비교)

  • Oh, Ju-Hee;Cha, You-Kyoung;Lee, Young-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.399-403
    • /
    • 2008
  • The aim of this study was to evaluate the difference of analytical methods for the pharmacokinetic study of bromosulfophthalein (BSP), an indicator of hepatobiliary function. The plasma and bile concentrations of BSP after intravenous administration were measured according to custom UV spectroscopy and HPLC, respectively. Plasma concentration of BSP measured by UV spectroscopy was similar to that measured by HPLC. There was no significant difference in the distribution volume, total body clearance, area under the curve and mean residence time of BSP between different analytical method groups. However, bile concentration of BSP measured by UV spectroscopy was overestimated compared with concentration measured by HPLC method. Biliary clearance of BSP obtained from UV spectroscopy method was almost 3 times higher than that obtained from HPLC method. Thus, a feasibility of UV spectroscopy method for high throughput pharmacokinetic evaluation of BSP was limited to the study based on the plasma concentration of BSP, not bile concentration.

A Study on the In-plane Displacement Measurement of Spot welded Joints by Electronic Speckle Pattern Interferometry Method (레이저 스패클 간섭법에 의한 점 용접부의 면내변위 측정에 관한연구)

  • 성백섭
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.48-53
    • /
    • 1997
  • Electronic Speckle Pattern Interferometry(ESPI) using the Model 95 Ar laserm, a video system and an image processor was applied to the in-plane displacement measurements. Unlike traditional strain gauges or moire method, ESPI method requires no special surface preparation or attachments and can be measured in-plane displacement with no contact and real time. In this experiment wpecimen was loaded in parallel with a loadcell. The specimen was the cold rolled sdteel sheet of 2mm thickness, which was attached strain gauges. The study provides an example of how ESPI have been used to measure strain displacement in this specimen. The results measured by ESPI have been used to measure strain displacement in this specimen. The results measured by ESPI have been used to measure strain displacement in this specimen. The results measured by ESPI compare with the data which was measured by strain gauge method in tensile testing.

  • PDF

Effect of Reinforcements on Dynamic Elastic Modulus of Polyethylene Matrix Composite Materials (폴리에틸렌기지 복합재료의 동적탄성계수에 대한 강화재의 효과)

  • 김경섭;정현규;홍순형
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.1-4
    • /
    • 1999
  • The attenuation coefficients of SiC particle reinforced low-density polyethylene (LDPE) matrix composites were measured by pulse echo method and dynamic elastic measure method with varying the volume fraction of SiC particle ranged from 0% to 40% and the size of SiC particles ranged from 0.8$\mu$m to 48$\mu$m. The SiCp/LDPE composites were fabricated with the melt injection process and the fabricated composites showed almost full density above 99% up to 40vo1% SiCp reinforcements. The attenuation constant of LDPE measured by dynamic elastic constant had same result with that measured by pulse echo method, but the attenuation constant of SiCp/LDPE measured by dynamic elastic constant did not have same result with that measured by pulse echo method.

  • PDF

A Comparison of Thoracic Gas Volume measured by Body Plethysmographic Method and Functional Residual Capacity measured by Closed Circuit Method (Body Plethysmograph 방법과 폐쇄식회로법으로 측정한 기능적잔기량의 비교)

  • Chung, Chee-Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 1970
  • By using Siregnost FD 91 body plethysmograph, we measured thoracic gas volume (TGVe) at end of expiration in 19 healthy subjects aged 20-43 years in order to compare with functional residual capacity (FRC) measured by closed circuit method. The results obtained were as follows 1. Mean values of TGVe and FRC were $3.395{\pm}0.5851{\ell},\;and\;3.393{\pm}0.618{\ell}$, respectively. 2. A advantage of the body phethysmographic method for measuring thoracic gas volume was that it were rapid, safe, and easy to perform, requires no gas sample for chemical analysis, and measured TGVe several times.

  • PDF

Comparison of Measured and Predicted Resting Metabolic Rate of 30-40 aged Korean Women (30-40대 성인여성의 휴식대사량 측정치와 추정 공식 적용 계산치의 비교)

  • Lee, Jeong-Suk;Lee, Ga-Hui;Kim, Eun-Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.13 no.2
    • /
    • pp.157-168
    • /
    • 2007
  • The purposes of this study were to measure the resting metabolic rate(RMR) of 30-40 year old women and to compare it with values predicted using published equations. Body weight, height and body fat of subjects were measured. RMR was measured by two indirect calorimeter(method 1 and method 2). RMR was predicted using various equations. Average height, weight and body fat(%) of subjects were 158.6cm, 59.1kg and 30.9%, respectively. The RMR(1621.2$\pm$301.5 kcal/day) measured by portable indirect calorimeter(method 2) was significantly higher than RMR(1447.4$\pm$223.6 kcal/day) measured by typical indirect calorimeter(method 1). Comparison of measured RMR with predicted RMRs suggested that there was a least difference in RMR predicted by equation of Cunningham. According to RMSPEs(Root Mean Squared Prediction Errors), equations of Cunningham and body surface area were found to predict measured RMR(by method 1) most accurately (within 239.1kcal/day and 232.9kcal/day, respectively). The fat free mass and fat mass - adjusted correlation showed that measured RMR(by method 1) had negative relationships with muscle mass(r = -0.873) and fat free mass(r = -0.866). The equations of Cunningham and body surface area provide relatively accurate estimates of RMR when determining energy needs of 30-40 aged women. There are needs for development of RMR predicted equations that are derived from large samples of Korean.

  • PDF

Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic (위상 검출 방식 레이저 스캐너의 APD bias 전압 특성을 이용한 검출신호세기 제어 방법)

  • Jang, Jun-Hwan;Yoon, Hee-Sun;Hwang, Sung-Ui;Park, Kyi-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1096-1100
    • /
    • 2012
  • In the phase-shift measurement method, the distance light travels can be obtained based on the phase difference between the reference signal and the measured signal. When the object having various colors is measured, the intensity of the measured signal much varies even at the same distance, and it causes different phase delay due to wide dynamic range input to a signal processing circuit. In this work, an measured intensity control method is proposed to solve this phase delay problem.

A Comparison of Methods for Estimating the Proper Cane Length for Hemiplegic Patients (성인편마비환자의 지팡이 길이 측정법 비교)

  • Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.1-7
    • /
    • 1996
  • Two standard methods of cane length measurements were compared to find which methods really achieve the elbow flexion of 20 degrees to 30 degrees Twenty-four patients with hemiplegia who were ambulatory participated in this study. Method I : Length of the cane measured from the floor to the top of the greater trochanter. Method II : Length of the cane measured from the floor to the distal wrist crease with the arm at the side. Using an adjustable cane, each individual was fitted according to the two methods, and elbow angle was measured after each adjustment. The elbow angle according to Method I and Method II was $46.4{\pm}20$, $44.3{\pm}12.2$, respectively. No significant difference was found in the elbow angle or the cane length between the two methods. Of the 24 participants, 5(20.8%) measured according to method I and 3(12.5%) measured according to method II showed the elbow angle between 20 degrees and 30 degrees. These low predictive rates of agreement between ideal cane length and actually achieved elbow angle showed that these two methods which have conventionally been accepted as a standard to measure ideal cane length need to be revised through further research.

  • PDF