• Title/Summary/Keyword: measurable range

Search Result 77, Processing Time 0.023 seconds

Feasibility study on the development of noncontact temperature sensor using infrared optical fiber (적외선 투과 광섬유를 이용한 비접촉식 온도 센서 개발을 위한 기초 연구)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Chung, Soon-Cheol;Tack, Gye-Rae;Jun, Jae-Hoon;Lee, Bong-Soo;Son, Sang-Hee;Cho, Seung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halides infrared optical fiber. An infrared radiation from a heat source is transferred by a silver halides infrared optical fiber and measured by infrared sensors such as a thermopile and a thermal optical power-meter. The relationships between the temperature of a heat source and the output voltage of the thermopile and the optical power of a thermal optical power-meter are determined. The measurable temperature range using a thermopile and a thermal optical power-meter are from 100 to $750^{\circ}C$ and from 30 to $750^{\circ}C$ respectively. It is expected that a noncontact temperature sensor using infrared optical fiber can be developed for medical and industrial usages based on the results of this study.

Micro-Machined Capacitive Linear Encoder with a Mechanical Guide (마이크로 머시닝으로 제작한 기계적 가이드를 갖는 정전용량 선형 인코더)

  • Kang, Daesil;Moon, Wonkyu
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.440-445
    • /
    • 2012
  • Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) is a novel displacement sensor which has wide measurable range with high resolution. The sensor, however, is very sensitive to relative rotational alignment between stator and mover of the sensor as well as its displacement. In addition to, there can be some disturbances in the relative rotational alignment, so some noises occur in the sensor's output signal by the disturbances. This negative effect of the high sensitivity may become larger as increasing sensitivity. Therefore, this negative effect of the high sensitivity has to be compensated and reduced to achieve nanometer resolution of the sensor. In this study, a new type capacitive linear encoder with a mechanical guide is presented to reduce the relative rotational alignment problem. The presented method is not only to reduce the alignment problem, but also to assemble the sensor to the stage conveniently. The method is based on a new type CLECDiS that has mechanical guide autonomously. In the presented sensor, when the device is fabricated by micro-machining, the guide-rail is also fabricated on the surface of the sensor. By the direct fabrication of the guide-rail with high precision micro-machining, errors of the guide-rail can be reduced significantly. In addition, a manual yaw alignment is not required to obtain large magnitude of the output signal after the assembly of the sensor and the stage. The sensor movement is going to follow the guide-rail automatically. The prototype sensor was fabricated using the presented method, and we verify the feasibility experimentally.

Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR (광섬유와 OTDR을 이용한 실시간 수위 및 온도 측정)

  • Sim, Hyeok In;Yoo, Wook Jae;Shin, Sang Hun;Jang, Jaeseok;Kim, Jae Seok;Jang, Kyoung Won;Cho, Seunghyun;Moon, Joo Hyun;Lee, Bongsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1239-1244
    • /
    • 2014
  • In this study, two fiber-optic sensors were fabricated to measure water level and temperature using optical fibers, a coupler, a Lophine and an OTDR (optical time-domain reflectometer). First, using Fresnel's reflection generated at the distal-ends of each optical fiber, which was installed at different depth, we measured the water level according to the variation of water level. Next, we also measured the temperature of water using a temperature sensing probe based on the Lophine, whose absorbance changes with the temperature. The measurable temperature range of the fiber-optic sensor is from $5^{\circ}C$ to $65^{\circ}C$ because the maximum operation temperature of the optical fiber without a physical deterioration is up to $80^{\circ}C$.

Development of Noncontact Temperature Sensor Using Silver Halide Optical Fiber for Medical Usages (Silver Halide 광섬유를 이용한 의료용 비접촉식 온도 센서 개발)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Chung, Soon-Cheol;Tack, Gye-Rae;Lee, Bong-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.337-342
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halide optical fiber. The infrared collimator and focus head are connected both ends of a silver halide optical fiber with SMA connectors and used to collimate radiations of a heat source and to focus them to infrared sensors such as a pyroelectric sensor and a thermopile sensor, respectively. The relation ships between the temperatures of a heat source and the output signals of the infrared sensors are determined to measure the surface temperature of a heat source. The measurable temperature range is from 25 to $60^{\circ}C$. It is expected that a noncontact temperature sensor using a silver halide optical fiber can be developed for medical usages such as temperature monitoring during hyperthermia, cryosurgery, laser surgery and diagnostic procedure based on the results of this study.

Experimental study of extracting artificial boundary condition frequencies for dynamic model updating

  • Hou, Chuanchuan;Mao, Lei;Lu, Yong
    • Smart Structures and Systems
    • /
    • v.20 no.2
    • /
    • pp.247-261
    • /
    • 2017
  • In the field of dynamic measurement and structural damage identification, it is generally known that modal frequencies may be measured with higher accuracy than mode shapes. However, the number of natural frequencies within a measurable range is limited. Accessing additional forms of modal frequencies is thus desirable. The present study is concerned about the extraction of artificial boundary condition (ABC) frequencies from modal testing. The ABC frequencies correspond to the natural frequencies of the structure with a perturbed boundary condition, but they can be extracted from processing the frequency response functions (FRF) measured in a specific configuration from the structure in its existing state without the need of actually altering the physical support condition. This paper presents a comprehensive experimental investigation into the measurability of the ABC frequencies from physical experiments. It covers the testing procedure through modal testing, the data processing and data analysis requirements, and the FRF matrix operations leading to the extraction of the ABC frequencies. Specific sources of measurement errors and their effects on the accuracy of the extracted ABC frequencies are scrutinised. The extracted ABC frequencies are subsequently applied in the damage identification in beams by means of finite element model updating. Results demonstrate that it is possible to extract the first few ABC frequencies from the modal testing for a variety of artificial boundary conditions incorporating one or two virtual pin supports, and the inclusion of ABC frequencies enables the identification of structural damages without the need to involve the mode shape information.

Development and Application of Acute Bioassay Method on Solid Samples using Bioluminescence Producing Bacteria (박테리아 발광 특성을 이용한 고형시료 급성 독성법 연구 및 적용)

  • Ko, Kyung-Seok;Kong, In-Chul;Jung, Hong-Gyung;Ro, Yul
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.46-52
    • /
    • 2007
  • A toxicity method using bioluminescence producing bacteria, Escherichia coli DH5 RB1436, was developed and applied on solid environmental samples. In the assay, 1 g soil sample was mixed with 4 ml RB1436 strain. Sets amended with p-buffer were employed for control in soil test, showing approximately 108% of sets amended with combusted soils. Measurable differences were observed between relatively more polluted groups (HP) and less polluted groups (LP) of soil samples, showing average toxicity 43 and 26%, respectively, in direct soil toxicity test. $EC_{50}$'s for all soil groups appeared in the range of $1.8{\sim}4.6\;g$, but those of sediments from dam reservoir and refuses were below 0.22 g. This developed bioassay should prove useful as a screening test for toxicity in various types of environmental solid samples.

Ifosfamide and Doxorubicin Combination Chemotherapy for Recurrent Nasopharyngeal Carcinoma Patients

  • Dede, Didem Sener;Aksoy, Sercan;Cengiz, Mustafa;Gullu, Ibrahim;Altundag, Kadri
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2225-2228
    • /
    • 2012
  • Background: We assessed the efficacy and toxicity of ifosfamide and doxorubicin combination chemotherapy (CT) regimen retrospectively in Turkish patients with recurrent or metastatic nasopharyngeal carcinoma (NPC) previously treated with platinum-based chemotherapy. Methods: A total of thirty patients who had received cisplatin based chemotherapy/chemoradiotherapy as a primary treatment received ifosfamide 2500 $mg/m^2$ days 1-3, mesna 2500 $mg/m^2$ days 1-3, doxorubicin 60 mg/m2 day 1 (IMA), repeated every 21 days. Eligible patients had ECOG PS< 2, measurable recurrent or metastatic disease, with adequate renal, hepatic and hematologic functions. Results: Median age was 47 (min-max; 17-60). Twenty six (86.7 %) were male. Median cycles of chemotherapy for each patient were 2 (range:1-6). Twenty patients were evaluable for toxicity and response. No patient achieved complete response, with nine partial responses for a response rate of 30.0% in evaluable patients. Stable disease, and disease progression were observed in five (16.7%) and six (20.0%) patients, respectively. Clinical benefit was 46.7%. Median time to progression was 4.0 months. Six patients had neutropenic fever after IMA regimen and there were one treatment-related death due to tumor lysis syndrome in first cycle of the CT. No cardiotoxicity was observed after CT and treatments were generally well tolerated. Conclusion: Ifosfomide and doxorubicin combination is an effective regimen for patients with recurrent and metastatic NPC. For NPC patients demonstrating failure of cisplatin based regimens, this CT combination may be considered as salvage therapy.

Management of GHG Emissions from the Public Organizaions in Land and Housing Construction Sector (토지·주택 건설부문 공공기관의 온실가스 배출량 관리방안 고찰)

  • Lee, Ki-Hong;Yoo, Jung-Hyun;Rhim, Joo-Ho;Jeon, Seon-Jeong
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.307-313
    • /
    • 2011
  • This study was aimed to suggest a management strategy of GHG emissions for the public organizations in land and housing costruction sector. As public organizations' businesses are characterized as 'public' and 'comprehensive', these characteristics should be considered in scoping emissions, setting-up reduction target, building GHG inventory, and establishing management system. Since public organizations' activities in construction sector involve a wide range of social infrastructure construction projects, it is not easy to account their actions to reduce GHG emissions quantitatively. Therefore, this study suggested that a twofold approach is suitable for public organizations in construction area, classifying the measurable reductions and the immeasurable actions according to the their business characteristics. To give a concrete example, a GHG emission management system for the Korea Land and Housing Corporation (LH) was proposed.

Characteristic analysis of a thermochromic material based fiber-optic temperature sensor for measuring temperature of subsurface water (열변성 물질을 이용한 지하수 온도 측정용 광섬유 온도센서의 특성분석)

  • Seo, Jeong-Ki;Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Heo, Ji-Yeon;Lee, Bong-Soo;Koh, Yong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.467-474
    • /
    • 2009
  • In this study, we describe the feasibility of developing a fiber-optic temperature sensor using a thermochromic material such as 2,4,5-triphenylimidazole or also called Lophine. A sensor-tip is fabricated by mixing of a Lophine powder, which has a non-toxic and hydrophobic characteristics, and an epoxy resin. The temperature change in the sensor-tip gives rise to a change in the optical absorbance of the Lophine, and the transmittance of a light through the Lophine is also changed. We have measured the intensities of modulated lights due to the change of optical absorbance of the Lophine by using of a photo-multiplier tube(PMT). The relationships between the temperatures and the output voltages of PMT are determined to measure the temperature of water. The measurable temperature range of the fiber-optic sensor is from 5 to $30^{\circ}C$.

Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant (냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발)

  • Yoo, Wook-Jae;Lee, Bong-Soo;Park, Byung-Gi;Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1730-1734
    • /
    • 2010
  • Generally, a pH value of secondary water in a nuclear power plant should be estimated after sampling and cooling down. In this process, the measurement of temperature is very important because a pH value is varied according to the temperature of secondary water. In this study, a noncontact fiber-optic temperature sensor using a silver halide optical fiber is fabricated to measure the temperature of cooled secondary water. And we have measured an infrared radiation, which is transferred by a silver halide optical fiber from a heat source, using a thermopile sensor. The relationships between the temperature of a heat source and the output voltage of the fiber-optic temperature sensor according to the change of distance and angle are determined. The measurable temperature range of the fiber-optic temperature sensor is from 25 to $60^{\circ}C$. Based on the results of this study, a noncontact temperature sensor using a silver halide optical fiber can be developed for the temperature measurement of the pH sample in the secondary water system.