• 제목/요약/키워드: meander line

검색결과 124건 처리시간 0.025초

마이크로스트립 Meander 라인의 S-파라메터 특성 (S-Parameter Characteristics of Microstrip Meander Line)

  • 김태원;신용조;김윤석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1201-1202
    • /
    • 2008
  • In this paper, using symmetrical condensed node(SCN), the TLM numerical technique has been successfully applied to microstrip meander line. A detailed technique of the symmetrical condensed node(SCN) may be used to model planar microstrip transmission line is presented. Also, the S-parameters $S_{11}$ and $S_{21}$ of microstrip meander line have been computed. From obtained results, TLM analysis is shown to be an efficient method for modeling complicated structure of planar microstrip transmission line.

  • PDF

지상파 DMB에 적용되는 소형 평면 안테나 (A Small Meander line Antenna for T-DMB Applications)

  • 채규수
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2008년도 추계학술발표논문집
    • /
    • pp.270-273
    • /
    • 2008
  • A small meander line antenna for T-DMB (Terrestrial Digital Multimedia Broadcasting) is presented. The antenna proposed here is based on a typical planar meander line antenna and miniaturized by using a double sided structure. A prototype antenna is manufactured based on the simulation results and the basic performances are measured. The presented antenna designed to operate in T-DMB band (174~216MHz) and can be adopted for various mobile applications.

  • PDF

미앤더 라인을 이용한 RFID 태그 안테나 최적 설계 (Optimized Design of a Tag Antenna for RFID using a Meander Line)

  • 김형석
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2293-2298
    • /
    • 2011
  • In this paper, A tag antenna structure for RFID application with resonant frequency of 920MHz is proposed using the meander line technique and Evolution Strategy. Miniaturization structure design for a tag antenna is performed by structure combining the half-wave dipole with a meander line. To achieve this, an interface program between a commercial EM analysis tool and the optimal design program is made for implementing the evolution strategy technique that seeks a global optimum of the objective function through the iterative design process consisting of variation and reproduction. The optimized tag antenna size is 63mm ${\times}$ 15mm ${\times}$ 1mm. And the proposed antenna is realized on FR-4 substrate (${\epsilon}_r=4.4$, $tna{\delta}=0.02$).

적층구조를 갖는 미앤더라인 칩 안테나 (A Meander-Line Chip Antenna with Stacked Layer)

  • 남인현;박성호;오태성;안병철
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.506-510
    • /
    • 2003
  • In this paper, a meander-line chip antenna with stacked layer is suggested, designed and fabricated employing the LTCC(Low Temperature Co-fired Ceramic) fabrication techniques. To reduce the antenna chip size, the meander-line antenna strip is distributed over three layer. Layers one interconnected using via holes. A 2.4 GHz chip antenna with size of $3.75{\times}7.9{\times}1.0 mm^3$ is designed and fabricated using the LTCC technique. Measurements of the fabricated antenna show 160 MHz bandwidth and 3.75 dBi maximum gain. The Measured reflection coefficient and radiation patterns agree well with the prediction by electromagnetic simulation.

  • PDF

Electromagnetic Behavior of High -$T_c$ Superconductors underthequenchstate -

  • 정동철;최효상;황종선;윤기웅;한병성
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.183-187
    • /
    • 2002
  • In this paper we analyzed the electromagnetic behavior of high $-T_{c}$ superconductor under the quench state using finite element method. Poisson equation was used in finite element analysis as a governing equation and was solved using algebra equation using Gallerkin method. We first investigate d the electromagnetic behavior of U-type superconductor. Finally we applied our analysis techniques to 5.5 kVA meander-line superconducting fault current limiters (SFCL) which are currently developed by many power-system researcher in the world. Meshes of 14,600 elements were used in analysis of this SFCL. Analysis results show that the distribution of current density was concentrated to inner curvature in meander-line type-superconductors and maximum current density 14.61 $A/\m^2$ and also maximum Joule heat was 6,420 W/㎥. We concluded that this meander line-type SFCL was not pertinet fur uniform electromagnetic field distribution.n.

  • PDF

마이크로스트립 미앤더 선로의 신호 왜곡 현상 연구 (The Study on Signal Distortion of Meander-shaped Microstrip Line)

  • 두진경;홍영표;김정민;육종관
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.197-202
    • /
    • 2005
  • In this paper, we analyzed the signal distortion incorporating meander-shaped transmission line on PCB in broadband frequency range, up to 50GHz. This broadband characteristic provides reasonable analysis of digital pulse having very short rising time. Simulation results reveal suppression characteristic at multiband which is dependent on only the width of meander arm. This width of arm also can be adjusted using different permittivity because it provides different effective wave-length. It is found that the suppression characteristic shows sharpness with as a function of the number of arms. However, these characteristics shown limitation for microstrip line structure rather than for stripline structure, so we can avoid these unwanted phenomena using stripline structure.

  • PDF

과도 사고 시 Au/YBCO 박막 곡선의 저항 거동 (Resistance Development in Au/YBCO Thin Film Meander Lines under High-Power Fault Conditions)

  • 김혜림;심정욱;최인지;임성우;현옥배
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.81-86
    • /
    • 2006
  • We investigated resistance development in $Au/YBa_2Cu_3O_7(YBCO)$ thin film meander lines during high-power faults. The meander lines were fabricated by patterning 300 nm thick YBCO films coated with 200 nm thick gold layers into meander lines. A gold film grown on the back side of the substrate was also patterned into a meander line. The front meander line was connected to a high-power fault-test circuit and the back line to a DC power supply. Resistance of both lines was measured during the fault. They were immersed in liquid nitrogen during the experiment. Behavior of the resistance development prior to quench completion could be understood better by comparing resistance of the front meander lines with that of the back. Quench completion point could be determined clearly. Resistance and temperature at the quench completion point were not affected by applied field strength. The experimental results were analyzed quantitatively with the concept of heat transfer within the meander lines/substrate and to the surrounding liquid nitrogen. In analysis, the fault period was divided into three regions: flux-flow region, region prior to quench completion, and region after quench completion. Resistance was calculated for each region, reflecting the observation for quench completion. The calculated resistance in three regions was joined seamlessly and agreed well with data.

  • PDF

YBCO 박막형 저항형 한류기에 적용 가능한 Meander Line 해석 연구 (Analytical Investigations on the Figures of Meander Lines on the YBCO Thin Film for Resistive Fault Current Limiters)

  • 이방욱;강종성;박권배;오일성;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.221-224
    • /
    • 2002
  • Superconducting electrical devices are under development in a national project in Korea. And KEPCO and LGIS are in charge of development of a resistive type fault current limiters(FCLs) with YBCO thin films. In order to realize FCLs, the rated power of FCLs must be increased. For this purpose, it is of great interest to increase of allowed voltage of unit component without electrical and thermal damages. So, meander lines were widely used for the conducting path to increase maximum electric field. In this research, numerical simulations on the electromagnetic behaviors of the device were carried out, especially focusing on the effect of meander line structures on the YBCO thin films. To evaluate the structures of meander lines, three types of meander lines were considered for numerical analysis using finite element method (FEM). In this simulation, both normal state and fault conditions were considered for calculation of electric field, current density, magnetic field density. And the simulation resulted are compared to find the optimum design of meander lines for resistive FCLs.

  • PDF

Open-Ended Two-Strip Meander-Line Antenna for RFID Tags

  • Son, Hae-Won;Choi, Gil-Young;Pyo, Cheol-Sig
    • ETRI Journal
    • /
    • 제28권3호
    • /
    • pp.383-385
    • /
    • 2006
  • A new meander-line antenna consisting of two open-ended strips is proposed for a compact and broadband UHF radio frequency identification tag. An equivalent circuit model for the proposed antenna is derived and used to perform a simple and wideband impedance match to an arbitrary complex impedance of a tag chip without any additional matching network. The performance of the proposed antenna is validated by comparing calculated and measured results, which show good agreement.

  • PDF

Design of a Small Radio Frequency Identification Tag Antenna Using a Corrugated Meander Line Applicable to a Drug Runout Sensor System

  • Ko, Dong-Ok;Woo, Jong-Myung
    • Journal of electromagnetic engineering and science
    • /
    • 제18권1호
    • /
    • pp.7-12
    • /
    • 2018
  • This article proposes an ultrahigh frequency band radio frequency identification (RFID) tag antenna for drug runout management that can be used in hospitals. The RFID tag antenna is designed to function as a sensor that alerts drug runout when a drug inside a drip chamber is completely consumed but does not work when a drug remains inside a drop chamber. A previously proposed 915 MHz dipole antenna, is too large to be attached to the drip chamber of a feeding bag. Moreover, the length of the dipole (L) should be increased for conjugate matching with an RFID chip. Therefore, the dipole antenna is downsized so that it can be attached to the drip chamber through a fine meander line structure coupling with a corrugate meander line. A transparent cover is added to enhance the grip force between the designed antenna and the drip chamber and to enable detachment. The dimensions of the completed antenna structure attachable to a drip chamber are 32.59 mm (height) and 13.5 mm (width). The gain reduction due to the decreased antenna length is enhanced. The fabricated antenna shows an average omni-directional read range of 10.65 m on a horizontal plane and has the function of sensing the presence of a drug.