• Title/Summary/Keyword: mean-line analysis method

Search Result 123, Processing Time 0.021 seconds

VALIDITY OF POSTERIOR ANTERIOR CEPHALOMETRIC AND 3D-CT FOR ORBITAL CANTING ANALYSIS (안와 경사의 분석을 위한 정모 두부규격방사선사진, 3D-CT의 유용성 평가)

  • Kim, Jin-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.546-553
    • /
    • 2008
  • Purpose: The purpose of this study was to estimate validity of posterior anterior cephalometric and 3D-CT for orbital canting analysis. Materials and methods: Three trained observers classified two patients group using standardized frontal photographs of facial asymmetry patients. Group A consisted of patients with facial asymmetry and orbital canting(n=19), and group B consisted of patients with only facial asymmetry(n=43). Orbital canting was measured with line of bilateral inferior orbitale. Orbital canting measurement was done with posterior anterior cephalometric and 3D-CT. Each horizontal reference line was established by bilateral GWSO(cephalometric), FZS(3D-CT). Maxillary canting and mandibular deviation angle were also measured and analyzed with orbital canting. Results: The mean orbital canting was $3.03{\pm}1.00^{\circ}$ in Group A and $1.11{\pm}0.76^{\circ}$ in Group B in frontal photograph. The mean orbital canting was $1.20{\pm}0.74^{\circ}$ in group A and $1.22{\pm}0.65^{\circ}$ in group B by cephalometric analysis(p>0.05). In 3D-CT, orbital canting was almost paralleled with horizontal reference line. The orbital canting, maxillay canting and mandibular deviation between two groups showed no significant differences except madibular deviation in 3D-CT. Conclusion: Common analysis of posterior anterior cephalometric and 3D-CT is not valide method to evaluate orbital canting for facial asymmetry patients with orbital canting.

Study on Efficient Time Domain Fatigue Analysis of Mooring Chain by Representative Mean Position (부유체 대표 평균 위치를 적용한 계류 라인의 시간 영역 피로 해석 효율화에 대한 연구)

  • Park, Jeongmoon;Kim, Yooil;Kim, Jeong-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.333-340
    • /
    • 2018
  • This paper addresses the concept of the representative mean position, which was devised to improve the numerical efficiency of a time domain fatigue analysis of a mooring chain. To investigate the influence of an artificial offset of the floater on the fatigue of the mooring chain, a parametric study was performed on the moored FPSO under various combinations of offsets and environmental conditions. Tension time histories were calculated using the de-coupled analysis method, and fatigue damages were calculated to determine the influence of the offset. The parametric study was extended to a more realistic case to determine the actual effect of the representative mean position, where a comparison was made between the two different analysis results, one using the representative mean position and the other one using the actual mean position. It was confirmed that the application of the representative mean position guaranteed the conservatism of the fatigue damage with the enhanced numerical efficiency in the time domain fatigue analysis.

A LATERAL CEPHALOMETRIC ANALYSIS OF MIDFACE FOCUSING ON ZYGOMATIC BONE IN KOREAN ADULTS (정상 한국인 성인 남녀에서 협골을 중심으로 한 중안모의 측모 두부방사선 규격사진 분석법)

  • Lee, Eui-Hoon;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.353-359
    • /
    • 1999
  • Purpose : A new method of lateral cephalometric analysis for midface, focusing on zygomatic bone, was created in this study, and measured in Korean adults. The purposes of this study are understanding about new approach for midfacial depression, especially zygomatic bone, and using to make adequate diagnosis and treatment plan. Materials and methods : In this study, esthetic Korean adults, 25 males and 25 females who were between $0^{\circ}$ and $4^{\circ}$ in ${\angle}ANB$, and between 62% and 70% in P/A facial height ratio, and had normal overbite and overjet, were used. Orbitale(Or) and Soft tissue orbitale(Or') were used for indicators of anteroposterior position of zygomatic area. And, mean value and standard deviation of linear and angular measurements, and ratio about each linear measurements, were obtained. then, standard deviation diagram - wiggle diagram - was made for visualization of results. Results : Mean values, standard deviations and ranges of 19 measurements were obtained, and among them, 5 linear measurements that had large standard deviation were excluded and the others were used for making standard deviation diagram. In standard deviation diagram, the following results were obtained. 1. If the measurements are located on more left side of mean-value-vertical -line, the potential of midfacial hypoplasia are stronger, especially zygomatic area. 2. If the measurements are located on more right side of mean-value-vertical-line, the potential of midfacial hypoplasia are decreased. Conclusion : This study presented a new method of lateral cephalometric analysis focusing on zygomatic bone in Korean adults. We expect that the results of this study can be used as parameter when clinicians make decisions about diagnosis and treatment plan for rehabilitation of esthetics and function. But, it is necessary to prove its usefulness, and to further evaluate the results.

  • PDF

Development of Posture Evaluation System through Digital Recognition Method (디지털 영상인식 방법을 통한 자세평가 및 운동가동범위 측정시스템 개발)

  • Moon, Young-Jin;Lee, Soon-Ho;Back, Jin-Ho;Lee, Jong-Gak;Lee, Gun-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.49-65
    • /
    • 2004
  • The purpose of this study is development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. The results of this study are as follows. First, Scoliosis evaluation through this research measurement system represent 3mm error in 7 cervical point and deepest lumbar point, 0.7mm error in other point. This mean this research measurement system have a reliability for scoliosis evaluation. Second, for spine line evaluation on high fat subject, we need reconstrection spine line after measurement for fat thickness in 7 cervical point and deepest lumbar point. Third, In pedioscope error test, it present 0.01848cm in X axis and 0.01757cm in Y axis. This results mean pedioscope have a reliability foot evaluation. Forth, Posture evaluation and Range of Motion measurement system by using digital vision analysis method can fast measure in range of motion and foot evaluation and posture. therefore we can expect this system application in young people posture clinic center and hospital and so on.

Validation on Residual Variation and Covariance Matrix of USSTRATCOM Two Line Element

  • Yim, Hyeon-Jeong;Chung, Dae-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.287-293
    • /
    • 2012
  • Satellite operating agencies are constantly monitoring conjunctions between satellites and space objects. Two line element (TLE) data, published by the Joint Space Operations Center of the United States Strategic Command, are available as raw data for a preliminary analysis of initial conjunction with a space object without any orbital information. However, there exist several sorts of uncertainties in the TLE data. In this paper, we suggest and analyze a method for estimating the uncertainties in the TLE data through mean, standard deviation of state vector residuals and covariance matrix. Also the estimation results are compared with actual results of orbit determination to validate the estimation method. Characteristics of the state vector residuals depending on the orbital elements are examined by applying the analysis to several satellites in various orbits. Main source of difference between the covariance matrices are also analyzed by comparing the matrices. Particularly, for the Korea Multi-Purpose Satellite-2, we examine the characteristics of the residual variation of state vector and covariance matrix depending on the orbital elements. It is confirmed that a realistic consideration on the space situation of space objects is possible using information from the analysis of mean, standard deviation of the state vector residuals of TLE and covariance matrix.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method (선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

Muscle Function Path Analysis through Muscle Activity Analysis of Human Myofascial Meridians

  • Park, Young Hyun;Hong, Aa Reum;So, Jea Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.279-285
    • /
    • 2017
  • Objective: The purpose of this study was to perform a muscle function path analysis of muscle function on myofascial meridians. Method: Seven male students (mean age: $22{\pm}3.46years$; mean mass: $72.71{\pm}8.19kg$; mean height: $174{\pm}4.39cm$) without a history of musculoskeletal system symptoms or injuries were recruited for this study. The measurement muscle of the myofascial line was selected along with the muscle presented in "anatomy trains (Thomas W. Myers. 2014)", and the attachment of the surface EMG (Telemyo 2400T G2, USA) pad was determined according to "EMG analysis (Kim Tae Wan et al., 2013)". The subjects underwent maximum volumetric contraction of their fascia line end muscles three times in lying and standing postures and were subjected to the maximum number of contractions of the myofascial line muscle three times in the lying and standing postures. The sampling rate of the EMG signal was set to 1,000 Hz, and the bandwidth was 20 to 350 Hz. The activity of each muscle was quantitated using the Pearson correlation coefficient, and SPSS 22.0 was used for data analysis. Results: In myofascial meridians, a positive correlation in the myofascial connection and a negative correlation in the mechanical connection were observed. Conclusion: Muscles that show significant contract correlations with one another may be expected to be used as an effective clinical marker in muscle strengthening or relaxation therapy, and rehabilitative training. In this study, the correlation of total myofascial meridians may differ without consideration of functional posture. Future studies need to consider these points.

A Study on the Edge Construction of CMM Data Using a Method of Mean Curvature Block (평균곡률 구간법을 이용한 CMM 데이터의 경계 형성 연구)

  • Chang, Byoung-Chun;Kim, Dae-Il;Oh, Seok-Hyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.74-80
    • /
    • 2010
  • The purpose of reverse engineering design using 3D measurement data is an accurate reconstruction of real body. In oder to accomplish this object, it is important that creating exact extracting edges should be studying out first of all. This study used edge-based method to find out edge point from the measuring point data. The characteristics are analysed using the mean curvature block method on the fitting NURBS curve and defined edges through block removal condition. The results showed that only using the NURBS curve of maximum curvature analysis to define correct edge of real geometry is limited, but this segmentation approach provides simplified necessary condition for edge classification, and an effectiveness to classify a straight line, curves and fillets etc.

Out-line Space-shape Variation of Clothing Fitness with Somatotype (체형유형에 따른 의복의 착의 공간 형상 변화)

  • 이수정
    • Korean Journal of Human Ecology
    • /
    • v.1 no.2
    • /
    • pp.113-118
    • /
    • 1998
  • Clothing shape is principally described in seven factors that are composed of clothing design, clothing material, clothing size, pattern design, sewing method and body motion etc.. The aims of this study was to measurement out-line space-shape variation of clothing fitness with somato type by using the image processing. The subjects for direct anthropometric measurements were 248 female college students aged from 19 to 22. The data were statistically analyzed by principal analysis and cluster analysis. The results were obtained three somato type. Also I made skirts in order to analyzed to the out-line space-shape variation of clothing fitness with body. The effect of somato type on the shape of flare skirts was determined by the out-line space-shape variation of clothing fitness with body. The out-line space-shape variation of clothing fitness with body was observed between the node number and amplitudes of clothing wave form and node number was determined at the maxim of space-shape amplitude, and the space-shape amplitudes have related with aspect ratio of cross-sectional shape. Results for flare skirts show changes in amplitude and mean with fabrics, somato type. therefore gray-level histogram are correlated with changes out-line space-shape, differences in drape spacing and related fabric properties and their somato type. (Korean J Human Ecology 1(2):113∼110 1998)

  • PDF

A Novel Equivalent Wiener-Hopf Equation with TDL coefficient in Lattice Structure

  • Cho, Ju-Phil;Ahn, Bong-Man;Hwang, Jee-Won
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.500-504
    • /
    • 2011
  • In this paper, we propose an equivalent Wiener-Hopf equation. The proposed algorithm can obtain the weight vector of a TDL(tapped-delay-line) filter and the error simultaneously if the inputs are orthogonal to each other. The equivalent Wiener-Hopf equation was analyzed theoretically based on the MMSE(minimum mean square error) method. The results present that the proposed algorithm is equivalent to original Wiener-Hopf equation. The new algorithm was applied into the identification of an unknown system for evaluating the performance of the proposed method. We compared the Wiener-Hopf solution with the equivalent Wiener-Hopf solution. The simulation results were similar to those obtained in the theoretical analysis. In conclusion, our method can find the coefficient of the TDL (tapped-delay-line) filter where a lattice filter is used, and also when the process of Gram-Schmidt orthogonalization is used. Furthermore, a new cost function is suggested which may facilitate research in the adaptive signal processing area.