• Title/Summary/Keyword: mean surface roughness

Search Result 253, Processing Time 0.024 seconds

THE ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE OF VARIOUS DENIAL MAGNETIC ATTACHMENTS (수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구)

  • Sohn Byoung-Sup;Chang Ik-Tae;Heo Seong-Joo;Keak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.336-350
    • /
    • 2001
  • The purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic(${\times}37.5$) and scanning electron microscopic view(SEM ${\times}100$) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.

  • PDF

Effects of the Rapier Weaving Tension Characteristics on the Surface Properties of PET Fabrics (래피어 직기 장력특성이 PET 직물의 표면특성에 미치는 영향)

  • Kim, Seung-Jin;Park, Kyung-Soon
    • Fashion & Textile Research Journal
    • /
    • v.7 no.6
    • /
    • pp.673-679
    • /
    • 2005
  • This study surveys the fabric surface properties such as mean value of the coefficient of friction(MIU), mean deviation of the coefficient of friction(MMD) and mean deviation of surface roughness(SMD) due to warp and weft tension differences using KES-FB system. For this purpose, fabric is designed as 5 harness Satin weave using 150d/48f warp and 200d/384f weft polyester filaments, and is woven by Omega$^{(R)}$ rapier loom by Textec Co.Ltd and Vamatex-P1001ES$^{(R)}$ rapier loom by Vamatex Co.Ltd respectively. These grey fabrics are processed on the same dyeing and finishing processes. The fabric surface properties according to the weaving looms are analysed with warp and weft weaving tensions. And also surveyed the difference of fabric surface properties according to the fabric positions such as center and each edge of fabrics for the sensitive garment. Fabric thickness was also measured and discussed according to the fabric positions such as center and each of fabrics with two looms weaving tensons.

Comparison of alkaline phosphatase activity of MC3T3-E1 cells cultured on different Ti surfaces: modified sandblasted with large grit and acid-etched (MSLA), laser-treated, and laser and acid-treated Ti surfaces

  • Li, Lin-Jie;Kim, So-Nam;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.235-240
    • /
    • 2016
  • PURPOSE. In this study, the aim of this study was to evaluate the effect of implant surface treatment on cell differentiation of osteoblast cells. For this purpose, three surfaces were compared: (1) a modified SLA (MSLA: sand-blasted with large grit, acid-etched, and immersed in 0.9% NaCl), (2) a laser treatment (LT: laser treatment) titanium surface and (3) a laser and acid-treated (LAT: laser treatment, acid-etched) titanium surface. MATERIALS AND METHODS. The MSLA surfaces were considered as the control group, and LT and LAT surfaces as test groups. Alkaline phosphatase expression (ALP) was used to quantify osteoblastic differentiation of MC3T3-E1 cell. Surface roughness was evaluated by a contact profilometer (URFPAK-SV; Mitutoyo, Kawasaki, Japan) and characterized by two parameters: mean roughness (Ra) and maximum peak-to-valley height (Rt). RESULTS. Scanning electron microscope revealed that MSLA (control group) surface was not as rough as LT, LAT surface (test groups). Alkaline phosphatase expression, the measure of osteoblastic differentiation, and total ALP expression by surface-adherent cells were found to be highest at 21 days for all three surfaces tested (P<.05). Furthermore, ALP expression levels of MSLA and LAT surfaces were significantly higher than expression levels of LT surface-adherent cells at 7, 14, and 21 days, respectively (P<.05). However, ALP expression levels between MSLA and LAT surface were equal at 7, 14, and 21 days (P>.05). CONCLUSION. This study suggested that MSLA and LAT surfaces exhibited more favorable environment for osteoblast differentiation when compared with LT surface, the results that are important for implant surface modification studies.

The evolution of microstructures and electrical properties of $Y_2O_3$ thin films on si(100) upon annealing treatments (열처리에 따른 $Y_2O_3$ 박막의 미세 구조 변화와 전기적 특성 변화에 대한 고찰)

  • 정윤하;강성관;김은하;고대홍;조만호;황정남
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3A
    • /
    • pp.218-223
    • /
    • 1999
  • We investigated the interfacial reactions between the $Y_2O_3$ film deposited by ICB processing and p-type (100) Si substrates upon annealing treatments in $O_2$ and Ar gas ambients. we also investigated the evolution of surface morphology of ICB deposited $Y_2O_3$ films upon annealing treatments. We observed that the root-mean-square(RMS) value of surface roughness measured by AFM increased with annealing time at $800^{\circ}C$ in $O_2$ ambient, while the change of surface roughness was not observed in Ar ambient. We also found the growth of $SiO_2$ layer and the formation of yttium silicate layer. From the capacitance values $(C_{acc})$ measured by C-V measurements, the relative didldctric constant of $Y_2O_3$ film in metal-insulator-semiconductor(MIS) structure was estimated to be about 9.

  • PDF

Pressure Losses in PVC Pipe and Fittings (PVC 배관부품의 마찰 손실)

  • Cho, Sung-Hwan;Choi, Jin-Hee
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.4
    • /
    • pp.209-214
    • /
    • 1984
  • Friction factors and equivalent sand roughness of PVC pipe fittings have been studied by experiments in the Reynolds number range of $2,000\~70,000$. PVC pipe fittings studied are straight pipes, $90^{\circ}$ elbows and tees with 15, 25, and 40mm in norminal diameter, all manufactured in Korea with KS mark approval. Equivalent relative roughness of PVC pipes obtained lies between smooth pipe and 0.002. The study shows that equivalent sand roughness of PVC pipes increasses in proportion of the square root of pipe diameter , and can be approximately abtained by multiplying 4 to the root mean square value measured by metal surface roughness tester. Loss coefficient of PVC $90^{\circ}$ elbows decreases slowly with increasing Reynolds number. Loss coeffiicent of tees is a function of ratio of flow rates and Reynolds number.

  • PDF

Randomized clinical trial to evaluate the efficacy and safety of two types of sandblasted with large-grit and acid-etched surface implants with different surface roughness

  • Jeon, Jun-Hyung;Kim, Min-Joong;Yun, Pil-Young;Jo, Deuk-Won;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.4
    • /
    • pp.225-231
    • /
    • 2022
  • Objectives: This study aims to evaluate the efficacy and safety of two types of sandblasted with large-grit and acid-etched (SLA) surface implants with different surface roughness. Patients and Methods: This study was conducted based on a clinical record review of 55 patients (mean age, 53.00 years). A total of 80 SLA surface implants was placed. Among the 80 implants, 38 implants placed in 29 subjects had surface roughness (Ra) of 3.09 ㎛ (test group, TG), while the other 42 implants placed in 31 subjects had a surface roughness (Ra) of 2.50 ㎛ (control group, CG). A comparison was made of implant primary/secondary stability; success and survival rates; marginal bone loss; and soft tissue assessment including probing pocket depth (PPD), plaque index (PI), gingival index (GI), and bleeding on probing (BOP) between the groups at 1 year after implant placement. Results: Among the implants that were initially registered, 1 from the TG and 4 from the CG dropped out, leaving 37 implants in the TG and 38 implants in the CG to be traced and analyzed. Although 1 TG case showed unstable primary stability, all cases showed stable secondary stability. Success and survival rates at 1 year after implant placement were 100% in both groups. Marginal bone loss was 0.07 mm and 0.00 mm for the TG and CG, respectively, but the difference was not significant. Among the several parameters for evaluation of soft tissue, the TG showed lower PI at 1 year after implant placement (TG=0.00, CG=0.29; P=0.0004), while the remaining categories showed no significant difference between the groups. Conclusion: This study shows that the two types of SLA implants with different surface roughness have no difference in efficacy or safety. Therefore, both of the implants can be used safely and with promising outcomes.

A Study on the Properties of TiN Films by Using Electron Beam Irradiation (전자-빔 조사를 이용한 TiN 박막의 물성변화에 관한 연구)

  • Shin, C.H.;Sung, Y.J.;Lim, S.Y.;Shin, G.W.;Jeong, C.W.;Kim,, S.K.;Kim, J.H.;You, Y.Z.;Kim, Dae-Il
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.1
    • /
    • pp.29-33
    • /
    • 2010
  • Titanium nitride (TiN) films were deposited on the polycarbonate substrate by using radio frequency (RF) magnetron sputtering without intentional substrate heating. After deposition, the films were bombarded with intense electron beam for 20 minutes. The intense electron irradiation impacts on the crystalline, hardness and surface roughness of the TiN films. The films irradiated with an electron beam of 300 eV show the small grains on the surface, while as deposited TiN films did not showany grains on the surface. Also the surface harness evaluated with micro indenter was increased up to 18 Gpa at electron energy of 900 eV after electron beam irradiation. In addition, surface root mean square (RMS) roughness of the films irradiated with intense electron beam affected strongly. The films irradiated by electron beam with 900 eV have the lowest roughness of 1.2 nm in this study.

Modeling of Plasma Etch Process using a Radial Basis Function Network (레이디얼 베이시스 함수망을 이용한 플라즈마 식각공정 모델링)

  • Park, Kyoungyoung;Kim, Byungwhan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • A new model of plasma etch process was constructed by using a radial basis function network (RBFN). This technique was applied to an etching of silicon carbide films in a NF$_3$ inductively coupled plasma. Experimental data to train RBFN were systematically collected by means of a 2$^4$ full factorial experiment. Appropriateness of prediction models was tested with test data consisted of 16 experiments not pertaining to the training data. Prediction performance was optimized with variations in three training factors, the number of pattern units, width of radial basis function, and initial weight distribution between the pattern and output layers. The etch responses to model were an etch rate and a surface roughness measured by atomic force microscopy. Optimized models had the root mean-squared errors of 26.1 nm/min and 0.103 nm for the etch rate and surface roughness, respectively. Compared to statistical regression models, RBFN models demonstrated an improvement of more than 20 % and 50 % for the etch rate and surface roughness, respectively. It is therefore expected that RBFN can be effectively used to construct prediction models of plasma processes.

Analysis of Texture Characteristics of Asphalt Pavements (아스팔트 포장의 노면조직 특성 분석)

  • Hong, Seong Jae;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.1-6
    • /
    • 2017
  • PURPOSES : Pavement textures can be categorized into four according to wavelength: microtexture, macrotexture, megatexture (roads), and roughness. Pavement surface texture influences a number of aspects of tire-pavement interaction such as wet-weather friction, tire-pavement noise, splash, spray, tire-wear, and rolling resistance. In particular, macrotexture is the pavement surface characteristic that considerably impacts tire-pavement noise. In general, it can be demonstrated that tire-pavement noise increases with the increase of texture depth and wavelength. Recently, mean profile depth (MPD) and wavelength have been used to evaluate tire-pavement noise. This study aimed to identify the relationship between mean profile depth and average wavelength for asphalt pavement based on the information obtained on a number of asphalt pavement sections. METHODS : Profile data were collected from a number of expressway sections in Korea. In addition, mean profile depth and average wavelength were calculated by using this profile data. Statistical analysis was performed to determine the correlationship between mean profile depth and average wavelength. RESULTS:This study demonstrates a linear relationship between mean profile depth and average wavelength for asphalt concrete pavement. CONCLUSIONS :The strong relationship between mean profile depth and average wavelength of asphalt pavement was determined in this study.

Gas Cluster ion Source for Etching and Smoothing of Solid Surfaces (고체 표면 식각 및 평탄화를 위한 가스 클러스터 이온원 개발)

  • 송재훈;최덕균;최원국
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.232-235
    • /
    • 2002
  • An 150 kV gas cluster ion accelerator was fabricated and assessed. The change of surface morphology and surface roughness were examined by an atom force microscope (AFM) after irradiation of $CO_2$ gas clusters on Si (100) surfaces at the acceleration voltages of 50 kV. The density of hillocks induced by cluster ion impact was gradually increased with the dosage up to 5$\times$10$^{11}$ ions/$\textrm{cm}^2$. At the boundary of the ion dosage of 10$^{12}$ ions/$\textrm{cm}^2$, the density of the induced hillocks was decreased and RMS (root mean square) surface roughness was not deteriorated further. At the dosage of 5x10$^{13}$ ions/$\textrm{cm}^2$, the induced hillocks completely disappeared and the surface became very flat. In addition, the irradiated region was sputtered. $CO_2$ cluster ions are irradiated at the acceleration voltage of 25 kV to remove hillocks on indium tin oxide (ITO) surface and thus to attain highly smooth surfaces. $CO_2$ monomer ions are also bombarded on the ITO surface at the same acceleration voltage to compare sputtering phenomena. From the AFM results, the irradiation of monomer ions make the hillocks sharper and the surfaces rougher On the other hand, the irradiation of $CO_2$ cluster ions reduces the hight of hillocks and planarize the ITO surfaces. From the experiment of isolated cluster ion impact on the Si surfaces, the induced hillocks m high had the surfaces embossed at the lower ion dosages. The surface roughness was slightly increased with the hillock density and the ion dosage. At higher than a critical ion dosage, the induced hillocks were sputtered and the sputtered particles migrated in order to fill valleys among the hillocks. After prolonged irradiation of cluster ions, the irradiated region was very flat and etched.

  • PDF