• Title/Summary/Keyword: mean stress sensitivity

Search Result 52, Processing Time 0.02 seconds

Clinical Usefulness of Fatigue Severity Scale for Patients with Fatigue, and Anxiety or Depression (피로와 우울.불안증 환자에서 Fatigue Severity Scale의 임상적 유용성)

  • Chung, Koo-In;Song, Chan-Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.9 no.2
    • /
    • pp.164-173
    • /
    • 2001
  • Objectives : Fatigue is a common symptom in primary medical care and has nonspecific and highly subjective features. So it has been difficult to define and measure fatigue, especially those present without any organic diseases. This study was conducted to evaluate the validity of the Fatigue severity scale(FSS) in patients with persistent fatigue who were free of any organic diseases or psychiatric disorders of depression or anxiety. Methods : Subjects consisted of 45 controls, 44 fatigued patients and 43 psychiatric patients with depression or anxiety. They all completed the fatigue severity, modified Bepsi stress, and Hospital anxiety and depression scales. Chalder fatigue scale was administrated randomly in 30 of them. Data were analyzed for reliability and validity of the FSS. Results: Cronbach's a coeffient of FSS was 0.929, and the Pearson correlation coefficient for test-retest was 0.916(p<0.01). ANCOVA for discriminant validity revealed that there were significant differences in mean FSS values among the three groups. The fatigue group had significantly higher FSS value than the other two groups. The psychiatric group also had significantly higher FSS value than the control group. The Pearson correlation coefficient for convergent validity by comparing FSS with Chalder fatigue scale was 0.782(p<0.01). Using FSS index 3.22 as the cut-off point, sensitivity was 84.1% and specificity was 85.7% for the fatigue and control groups, respectively. Conclusion : Results suggested the clinical application of the FSS to be a useful measurement for distinguishing fatigue between patients with physiologic fatigue and psychiatric patients with depression or anxiety.

  • PDF

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.