• Title/Summary/Keyword: mean square slope

Search Result 61, Processing Time 0.023 seconds

Fundamental periods of reinforced concrete building frames resting on sloping ground

  • De, Mithu;Sengupta, Piyali;Chakraborty, Subrata
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.305-312
    • /
    • 2018
  • Significant research efforts were undertaken to evaluate seismic performance of vertically irregular buildings on flat ground. However, there is scarcity of study on seismic performance of buildings on hill slopes. The present study attempts to investigate seismic behaviour of reinforced concrete irregular stepback building frames with different configurations on sloping ground. Based on extensive regression study of free vibration results of four hundred seventeen frames with varying ground slope, number of story and span number, a modification is proposed to the code based empirical fundamental time period estimation formula. The modification to the fundamental time period estimation formula is a simplified function of ground slope and a newly introduced equivalent height parameter to reflect the effect of stiffness and mass irregularity. The derived empirical formula is successfully validated with various combinations of slope and framing configurations of buildings. The correlation between the predicted and the actual time period obtained from the free vibration analysis results are in good agreement. The various statistical parameters e.g., the root mean square error, coefficient of determination, standard average error generally used for validation of such regression equations also ensure the prediction capability of the proposed empirical relation with reasonable accuracy.

Concentration Error Assessment by Comparison of Solar Flux Measurement and Modeling (집광 열유속 측정과 모델링의 비교를 통한 집광 오차 평가)

  • Chai, Kwan-Kyo;Yoon, Hwan-Ki;Lee, Hyun-Jin;Lee, Seong-Uk;Kim, Si-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.82-90
    • /
    • 2013
  • Concentration errors critically affect the performance of solar concentrator, so their evaluation is important to the concentrated solar power technology. However, the evaluation is very challenging because error sources are various and not easy to measure individually. Therefore, the integrated effect of concentration errors is often more interesting and useful for large-scale applications. In the present work, we analytically investigate and classify various concentration error sources and then explain that the effect of various concentration errors can be represented in terms of a root mean square value of reflector surface slope error. We present an indirect approach to assessing the reflector surface slope error by comparing solar flux measurement data with modeling calculations. We apply the approach for solar furnaces with different thermal capacity and investigate its advantages and disadvantages.

A Study on a Comparison of Sky View Factors and a Correlation with Air Temperature in the City (하늘시계지수 비교 및 도시기온 상관성 연구: 강남 선정릉지역을 중심으로)

  • Yi, Chaeyeon;Shin, Yire;An, Seung Man
    • Atmosphere
    • /
    • v.27 no.4
    • /
    • pp.483-498
    • /
    • 2017
  • Sky view factor can quantify the influence of complex obstructions. This study aims to evaluate the best available SVF method that represents an urban thermal condition with land cover in complex city of Korea and also to quantify a correlation between SVF and mean air temperature; the results are as follows. First, three SVF methods comparison result shows that urban thermal study should consider forest canopy induced effects because the forest canopy test (on/off) on SVF reveals significant difference range (0.8, between maximum value and minimum value) in comparison with the range (0.1~0.3) of SVFs (Fisheye, SOLWEIG and 3DPC) difference. The significance is bigger as a forest cover proportion become larger. Second, R-square between SVF methods and urban local mean air temperature seems more reliable at night than a day. And as the value of SVF increased, it showed a positive slope in summer day and a negative slope in winter night. In the SVF calculation method, Fisheye SVF, which is the observed value, is close to the 3DPC SVF, but the grid-based SWG SVF is higher in correlation with the temperature. However, both urban climate monitoring and model/analysis study need more development because of the different between SVF and mean air temperature correlation results in the summer night period, which imply other major factors such as cooling air by the forest canopy, warming air by anthropogenic heat emitted from fuel oil combustion and so forth.

Evaluation of the equation for predicting dry matter intake of lactating dairy cows in the Korean feeding standards for dairy cattle

  • Lee, Mingyung;Lee, Junsung;Jeon, Seoyoung;Park, Seong-Min;Ki, Kwang-Seok;Seo, Seongwon
    • Animal Bioscience
    • /
    • v.34 no.10
    • /
    • pp.1623-1631
    • /
    • 2021
  • Objective: This study aimed to validate and evaluate the dry matter (DM) intake prediction model of the Korean feeding standards for dairy cattle (KFSD). Methods: The KFSD DM intake (DMI) model was developed using a database containing the data from the Journal of Dairy Science from 2006 to 2011 (1,065 observations 287 studies). The development (458 observations from 103 studies) and evaluation databases (168 observations from 74 studies) were constructed from the database. The body weight (kg; BW), metabolic BW (BW0.75, MBW), 4% fat-corrected milk (FCM), forage as a percentage of dietary DM, and the dietary content of nutrients (% DM) were chosen as possible explanatory variables. A random coefficient model with the study as a random variable and a linear model without the random effect was used to select model variables and estimate parameters, respectively, during the model development. The best-fit equation was compared to published equations, and sensitivity analysis of the prediction equation was conducted. The KFSD model was also evaluated using in vivo feeding trial data. Results: The KFSD DMI equation is 4.103 (±2.994)+0.112 (±0.022)×MBW+0.284 (±0.020)×FCM-0.119 (±0.028)×neutral detergent fiber (NDF), explaining 47% of the variation in the evaluation dataset with no mean nor slope bias (p>0.05). The root mean square prediction error was 2.70 kg/d, best among the tested equations. The sensitivity analysis showed that the model is the most sensitive to FCM, followed by MBW and NDF. With the in vivo data, the KFSD equation showed slightly higher precision (R2 = 0.39) than the NRC equation (R2 = 0.37), with a mean bias of 1.19 kg and no slope bias (p>0.05). Conclusion: The KFSD DMI model is suitable for predicting the DMI of lactating dairy cows in practical situations in Korea.

The Study on the Optimal Angle of the Solar Panel using by Solar Radiation Model (태양복사모델을 이용한 태양전지판의 최적 경사각에 대한 연구)

  • Jee, Joon-Bum;Choi, Young-Jean;Lee, Kyu-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.64-73
    • /
    • 2012
  • The angle of solar panels is calculated using solar radiation model for the efficient solar power generation. In ideal state, the time of maximum solar radiation is represented from 12:08 to 12:40 during a year at Gangneung and it save rage time is12:23. The maximum solar radiation is 1012$W/m^2$ and 708$W/m^2$ inc lear sky and cloudy sky, respectively. Solar radiation is more sensitive to North-South (N-S) slope angle than East-West (E-W) azimuth angle. Daily solar radiation on optimum angle of solar panel is higher than that on horizontal surface except for 90 days during summer. In order to apply to the real atmosphere, the TMY (typical meteorological Year) data which obtained from the 22 solar sites operated by KMA(Korea Meteorological Administration) during 11 years(2000 to 2010) is used as the input data of solar radiation model. The distribution of calculated solar radiation is similar to the observation, except in Andong, where it is overestimated, and in Mokpo and Heuksando, where it is underestimated. Statistical analysis is performed on calculated and observed monthly solar radiation on horizontal surface, and the calculation is overestimated from the observation. Correlationis 0.95 and RMSE (Root Mean Square Error) is10.81 MJ. The result shows that optimum N-S slope angles of solar panel are about $2^{\circ}$ lower than station latitude, but E-W slope angles are lower than ${\pm}1^{\circ}$. There are three types of solar panels: horizontal, fixed with optimum slope angle, and panels with tracker system. The energy efficiencies are on average 20% higher on fixed solar panel and 60% higher on tracker solar panel than compared to the horizontal solar panel, respectively.

Fabrication of High Speed Modulation Doped SMQW-PBH-DFB-LD (변조 도핑된 SMQW-PBH-DFB-LD의 고속변조 특성)

  • 장동훈;이중기;조호성;박경형;김정수;박철순;김흥만;편광의
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.228-232
    • /
    • 1995
  • We have made modulation doped SMQW-PBH-DFB-LD for high speed optical communications. The waveguide and barrier layers were doped by Zn with the concentration of $1.2 \times 10^{18}cm^{-1}$. Mean threshold current and slope efficiency were 24.88 mA (minimum 16 mA) and 0.197 mW/mA (maximum 0.275 mW/mA) respectively. Linewidth enhancement factor ($\alpha$) of MD-SMQW-PBH-DFB-LD was reduced than that of SMQW-PBH-DFB-LD. Linewidth enhancement factor of 1.8 owes to the large gain coefficient of modulation doped active layer. The resonance frequency was linearly increased with the square root of optical power. The resonance frequency in small signal modulation was measured as 8 GHz and -3 dB modulation bandwidth was 10 GHzat $46mA(I_{th}+30mA)$..

  • PDF

A Study on the Boronizing treatment of the microalloyed steel (비조질강의 Boronizing 처리에 관한 연구)

  • 김강형;선명숙;윤재홍;변응선;권동일
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.4
    • /
    • pp.268-277
    • /
    • 1996
  • Boronizing treatment of Microalloyed steel has been investigated by mean of Boronizing paste mainly consisted of $B_4C$ at various temperatures and times. The micro hardness of the boride layers were about HV 1200~1500. The thickness of the boride layer were increased with an increase of square root of treatment time at constant temperature. The activation energy for diffusion of boron in the specimen obtained from the slope of Arrhenius plots was 254 kJ/mol, but 197 kJ/mol for the induction heated specimen. The boride layer had a good corrosion resistance in solutions of 20% HCl and 20% $H_2SO_4$, solution. In 20% $HNO_3$ solution, however, its corrosion resistance increased. The boride layer had a good high temperature oxidation resistance at below $800^{\circ}C$, but at temperature above $900^{\circ}C$, the oxidation resistance decreased as the oxidation temperature.

  • PDF

Influence of Aging on Surface EMG Signals Generated Under Sustained Fixed Load Contraction (고정 부하 수축시 기록한 표면근전도 신호에 대한 노화의 영향)

  • Lee, Jin;Kim, Sung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1497-1505
    • /
    • 2010
  • The present study was performed to investigate the effect of aging on muscular activity of older subjects under the condition of fixed load muscle contraction. SEMG signals were recorded from old (46 women) and young (45 women) groups performing sustained isometric elbow flexion contraction with a fixed load during 30 seconds. Linear regression and mean square error (MSE) analysis with four characteristic variables (ARV, RMS, MDF, MNF) were used to compare the age-related difference (of local muscle fatigue and fluctuation of the amplitude and frequency) in the SEMG signal. The main results can be summarized as follows: During sustained muscle contraction with a fixed load: i) the MSE values of amplitude (ARV, RMS) and frequency (MDF, MNF) variables were more than 30% higher for the young than for the old adults; ii) the measures of local muscle fatigue (slope of the MDF and MNF) indicated greater fatigue in the old; and iii) the rate of increase of the SEMG amplitude was higher for the young than the old.

Development of new Multifunction Voltage Recorder (다기능 디지털 전압기록장치 시스템 개발)

  • Shon, Su-Goog;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.693-696
    • /
    • 1999
  • This paper describes a new voltage recorder for the voltage management of a power distribution line by using a new voltage measurement technique. The RMS(Root Mean Square) voltage measurement for the power line under the assumption of a sinusoidal input voltage is taken by the full-wave rectifier, half-adder utilizing operational amplifier(OP) circuit. A/D converter utilizing a dual slope converter converts an analog voltage signal into a serial pulse. The pulse is counted with a single chip micro-controller, converted with the RMS voltage, and saved into a flash memory. In the last, a new voltage recorder with compact size and multifunction is developed. Also, Voltage Management System that can analyze the stored data via RS-232C cable is developed based on Windows 95 and Visual C++.

  • PDF

초정밀 비구면의의 설계, 측정 및 가공의 비용절감을 지원하는 새로운 비구면 표현식 Q Polynomials의 소개

  • Sin, Ji-Sik
    • The Optical Journal
    • /
    • s.150
    • /
    • pp.31-41
    • /
    • 2014
  • 현재까지 많은 업체에서 사용되는 비구면 표현식의 단점을 해결하여 직관적이며 예측가능한 면을 표현할 수 있는 새로운 비구면 표현식, 일명 Q Polynomials (또는 Forbes Polynomials, Q-type Polynomials)을 소개한다. Q Polynomials은 기존 quadratic polynomial을 이용한 표현식과 달리 서로 영향을 미치지 않는 유일한 함수 Qm를 기본으로 하는 다항식으로 구성되어 있기 때문에 각 계수는 하나의 비구면에 대해 유일한 계수다. 각 항의 함수의 모양이 이미 정해져 있기 때문에 계수들의 크기를 살펴보면 비구면도, 측정 가능성, 가공 및 생산 가능성에 대한 예측이 가능하다. 따라서 비구면 설계 시점에서부터 시험/검사, 생산이 실질적으로 가능한 비구면 광학요소인지가 판정되므로 설계시부터 설계자, 시험/검사자, 생산자 사이의 합의가 이루어지는 것과 같다. 따라서 생산성과 간섭계 측정을 이용한 초정밀 비구면를 제조할 수 있는 결과에 이르게 된다. 이미 도입한 여러 업체에서 긍정적인 결과를 얻고 있다. Q polynomials은 기존에 현업에서 사용되고 있는 광학 설계 프로그램에도 적용되어 사용 가능하다.

  • PDF