• Title/Summary/Keyword: mean skin temp

Search Result 11, Processing Time 0.026 seconds

Thermo Physiological responses of Far Infrared Ray Radiation Fabrics at outdoor in summer (옥외에서 원적외선 방사직물 착용시 온열생리반응)

  • 송명견;안필자;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1996
  • This study was performed to define the effects of Far Infrared Ray Radiation Fabrics as summer garments during outdoor work by human trial. One healthy male subject was volunteered for this study. Experimental garments consisted of three kinds of trousers (Cotton, Cotton/linen blended, Far Infrared Ray Radiation Fabric/wool blended) and basic garments (panty, socks, shirts, and dress shirts). The measurements were rectal temp., skin temp., microclimate inside clothing, heart rate, subjective sensation etc. The results were as follows : 1. Rectal temperature showed the lowest in Far Infrared Ray Radiation Fabrics among 3 garments. 2. Skin temperature (forehead, chest abdomen temp.) and mean skin temperature were lower in Far Infrared Ray Radiation Fabrics than in others, especially during early stage of work. 3. Heart rate showed lower value in Far Infrared Ray Radiation Fabrics than in others but there was no significance among the garments. 4. Humidity inside clothing and total weight loss showed the highest value in Far Infrared Ray Radiation Fabrics.

  • PDF

A Study on the Optimal Clothing Weight in an Air Conditioned Office in Summer (여름철 냉방실내의 적정착의량에 관한 연구)

  • Kim Sun Young;Lee Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.3
    • /
    • pp.45-51
    • /
    • 1985
  • The purpose of this study is to research into the thermal condition and the weight of clothes suitable for the officers engagged in light works in an air-conditioned room in summer. The Major findings are as follows: 1. Thermal conditions of the working environment are $24.5^{\circ}C$ (Dry bulb temp.), $68\%$ (Relative humidity) and 2.6m/sec (Air Velocity). 2. Total clothing weights are 416.6 g/$m^2$ (male) and 340.9 g/$m^2$ (female). Underwear weights are 96.8g/$m^2$ (male) and 85.1g/$m^2$ (female). The latter turned out to be statistically significant in Sexual difference. 3. Means of the thermal sensation are 3.0 (comfortable; male) 2.7 ('Slightly cool' -'Comfortable'; female) and the relationship between clothing weights and thermal sensation proves to be significantly correlated in the case of female. 4. $66.7\%$ of the women and $37.1\%$ of the men feel sensation of coldness at the body's specific area and $79.5\%$ of the women and $54.3\%$ of the men reveals air-conditioning disturbance. 5. As the thermal sensation is close to 'cool-cold', sensation of coldness or air conditioning disturbance are showed up more frequently which is reversely related with weight of under-wear. It is also proved that air conditioning disturbances are influenced by sexual difference in addition to sensation of coldness and thermal sensation. 6. According to the result of experiment, we can have the idea that at condition $X_1$, the drop of limbs' skin temp. is remarkable. At condition $X_2$ skin temp. for distal limbs and mean skin temp. are raised and the falling degree is similar. At condition $X_3$, mean skin temp. and distal skin temp. are remarkably raised, and the falling degree decreases and the beats of pulse rate increase and diastoric blood pressure is lowered.

  • PDF

Effectsd of posture on physiological thermal responses with Ondol heating system (온돌난방에서의 자세에 따른 온열생리적 반응의 성차)

  • 신정화;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

A Study on the Comfort, Physiological Responses and Microclimate in Beding Pad (온돌에서의 욕의 쾌적성에 관한 연구)

  • Lee Soon Won;Kweon Soo Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.1 s.33
    • /
    • pp.44-54
    • /
    • 1990
  • The purpose of this study was to investigate the effects of thickness of the sleeping pad on the physiological responses and the microclimate in the heating ondol room during sleeping time. The measuring points were skin temp., weight loss and body movement as physiological responses and the compression ratio, the temp. on/under the sleeping pad, the inside limp. of the sleeping quilts and subjective sence while 7 hours sleeping. Thickness of sleeping pads was 27.2 mm(A), 34.8 mm (B), 47.9 mm(C) used for 90 days and no used pad 60.7 mm(D). The floor surface temp. was keeping $29{\pm}1^{\circ}C$ while the environmental conditions was at $23{\pm}1^{\circ}C$ ($50{\pm}5\%$ R.H.) The results were as followings; 1) The mean compression ratio after using the sleeping pads for 45 days was about $70\%$ , and it wasn't increased any more thereafter 2) After 2 hours sleeping the temp. under the sleeping pads was shown that C and D were higher than A and B, and the temp. on the sleeping pads was shown that A and C pads were higher than B and D. But after 3-4 hours sleeping the skin temp. of legs was shown that B and D pads were higher than A and C. 3) Weight loss for C pad was significantly higher than others. Body movement and side position in tying was higher in A and C pads than B and D. 4) The inside temp. of quilt for A and C pads were higher in the early part of sleeping period than those of B and C pads and relative humidity was lower in C than others. 5) D pad was softer than others and fatigue degree was turned out to be lowest in D, the highest in A. From this point of view, we concluded that thickness of the sleeping Pad in the heating ondol room had different characteristic from that in no heating ondol room. And 35 mm used pad was turned out to be proper.

  • PDF

UV ray protective function and wear sensation of garment for plastichouse worker (비닐하우스용 작업복의 자외선 차단 성능과 착용감 연구)

  • 최정화;백윤정
    • Korean Journal of Rural Living Science
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 1995
  • This study was designed to obtain the basic data developing the UV ray protective garments for the plastichouse workers. Two subjects were volunteered for 1hr. wear test in plastic house, and the ensembles was composed of one of three kinds blouse (UV blocking blouse, polyester/cotton 47/53 blouse, and polyester blouse), shorts, sleeveless undershirts, pants and socks. The measurements were rectal temperature, skin temperature, microclimate inside clothing, subjective sensation, and the colour difference of UV sensor. The results were as follows: 1. Microclimate especially, temperature inside clothing of polyester blouse was the highest among the garments. And UV-proof polyester blouse showed the lower mean skin temperature and microclimate than others. Showing the highest sweat volume. 2. No significant difference on UV ray blocking function among 3 kinds of garment was shown. 3. We could conform that in spring for the plastic house wぉw s garment low thermal insulating value and wide covering area were more important factors than UV blocking function of fabric.

  • PDF

The Effect of Napping of Knitted Fabric on Wear Sensation (편성물의 기모가공이 착용감에 미치는 영향)

  • Lee Jong-Min;Lee Soon-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.11 no.3 s.25
    • /
    • pp.41-55
    • /
    • 1987
  • The purpose of this study is to investigate the effects of napping of knitted fabric on wear sensation and physiological responses. Experimental garments were four types of warm-ups made of either $100\%$ PET or $65/35\%$ P /C and either napped or unnapped respectively. Two healthy young female adults were chosen as subjects for the experiment. Experimental room conditions were as follows: Temp., $22\pm0.5^{\circ}C$ R.H., $54\pm3\%$ and Air Velocity, 0.25m/ sec or 2. 86m/sec. The subjects exercised on bicycle ergometer and rested alternatively for totally 45-min. The results are summarized as follows. 1) With napped Warm-up, chest, back, mean skin temp. and microclimates, i.e., temp., relative humidity and water vapor pressure inside the clothing, were higher than with unnapped warm-up. And there was no difference in pulse rate between napped and unnapped warm-ups. 2) Wear sensations of thermal, humidity, tactile and comfort were 'more hot' and 'more uncomfortable' in 0.25m/sec air velocity. but in 2.86m/sec condition the tactile sensation was 'better' and 'more comfortable' with napped warm-ups. According to Pearson's Correlation, among various kinds of wear sensations, tactile is most related with comfort. From these results, it can be concluded that napped fabric decreases the rate of heat trans? mission and moisture diffusion through the clothing. Therefore skin and body temp. and temp., R.H., Vapor Pressure inside the clothing are increased.

  • PDF

Skin Temperature Responses of Hanbok When It Worn (한복 착용에 따른 피보온의 변화)

  • 송명견;신정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.763-770
    • /
    • 2002
  • The objective of the study was to investigate skin temperature responses of Hanbok when it was worn. Two healthy females(average 21 years, 155cm and 60kg were exposed to a climatic chamber(Room Temp. $21{\pm}1^{\circ}C,\;52{\pm}2%R.H.$, 0.15m/s). During the experiment, rectal temperature, skin temperature of 9 areas, clothing microclimate, subjective sensation were measured. Chima and Jogory to be made of silk nobang(SN) or Ramie were worn for summer. Polyester(P) Chima and Jogori(R) could be wort for spring and autumn. For winter, silk Chima, Jogori(S) and Durumagi(D) were commonly worn. Rectal temperature was high in order of naked(N), R, SN, P, S, D. However Mean skin temperature was reversely high in order of D, S, SN, R, P, naked. In naked, skin temperature was high in order of head, trunk upper extremity and lower extremity. But on wearing of Hanbok, it was the highest at the chest except head regardless of kinds of clothing ensembles. Skin temperature of upper arm was secondly highest on wearing the silk ensemble and the Durumagi ensemble, but skin temperature of buttock was secondly highest on wearing the silk nobang ensemble and the ramie ensemble. Skin temperature on wearing the silk ensemble was generally higher than those on other clothing ensembles. Local and mean skin temperatures on wearing the silk ensemble and the Durumagj ensemble were generally higher than on other clothing ensembles. Heat resistance of the fabric might have affected on the local skin temperature.

직물의 자외선 방어율에 따른 인체의 Vit. $D_3$ 합성과 온열생리적인 반응

  • 송명견;안령미;신정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.980-986
    • /
    • 1999
  • This study was done to ivestigate the fabrics thatminimized harmfulness of UVB(ultraviolet B) and that might product Vit. {{{{ {D }`_{3 } ^{ } }} by UVB. Twelve female subjects wearing in three different types i.e fabric A(UVB 100% protection) fabric B(UVB 50% protection) and bikinii were exposed to outdoor environment (Air Temp : 25℃, 42% R,H Air velocity : 0.13m/s UV does :6KJ/m2) Blood samples were taken 24 hours before the after the experiment in order to examine concentration of vit.{{{{ {D }`_{3 } ^{ } }} in the blood. During the experiment axillary temperature skin temperature of 7 areas(forehead Chest Upper arm, Hand Thigh Lower leg, Foot) were measured. The more irradiated areas by UVB were the more the concentration of serum 25(OH){{{{ {D }`_{3 } ^{ } }} were significantly. Mean skin temperature was significantly low levekl in wearing the fabric of UVB 50% protection (p<0.001) Axillary temperature was significantly high level in wearing the fabric of UVB 50% protection (p<0.001). Therefore the fabric of UVB 50% protection intercepts the radiation and has advantage to give off body heat over other fabrics

  • PDF

Effects of Covering Parts of Body with Garments on Human Thermoregulation and Sensation(II) (신체의 부위별 피복이 체온조절 및 주관적인 감각에 미치는 영향(II))

  • 이종민
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • In this study the physiological significance of the upper and lower body on thermoregulation and sensation are examined. Experiments were carried out on 4 females in a climatic chamber conditioned at $25\pm1^{circ}C, 50\pm5%$ R.H.. Before the measurements, subjects were exposed to 3 types of enviromental temperature: 1) $25\pm1^{\circ}C$ for 60 min.(ST), 2) $25^{\circ}C$\rightarrow35^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(HT), 3) $25^{\circ}C$\rightarrow15^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(LT) covering the upper body (U) or lower body (L) with garments. 1) $T_{re}$ was significantly higher in L than in U only in 57 condition. $T_{sk}$ and Temp. under the clothing were higher in U than in L in all three conditions. Thermal sensation was warmer in U than in L, and comport sensation was most comfortable in HT condition. 2) When the upper or lower body was covered or exposed, the mean skin temperature of the upper body was higher than that of the lower body. Following covering and uncovering the same area, the changes in skin temperature were greater in the upper body than in lower body, and covering the upper body produced a greater difference of skin temperature between body and lower body than covering the lower body. 3) In all environmental conditions, when the upper body was uncovered, the skin temperatures of the chest, upper arms and forearms dropped to a considerable degree, and when the lower body was uncovered, skin temperatures of the legs showed the same pattern. On the other hand, skin temperature of the thinghs showed only little change in all cases except forehead and back uncovered or covered in two clothing types.

  • PDF

The Effectso f Textiles Materials and Wearing Type on the Thermal Insulation Value (의복의 소재 및 형태가 보온력에 미치는 영향)

  • 손원교;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1098-1109
    • /
    • 1999
  • This study was to examine the effects of textiles materials and wearing types on the thermal regulation responses of human, Cotton polyester wool silk and rayon were chosen as outerwears and acetate was selected as a lining. Blouse-skirt suits blouse-slacks suits and one-piece dress made of selected textiles were examined by human trials, Tests results were as follows ; 1 When subjects wore vlouse-slacks suits Tmsk was showed the highest value. There was a significant difference on Tmsk(p<0.05) when they wore one-piece dress. The temperature of microclimate inside clothing when subjects wore blouse-slacks suits showed the highest value and one-piece dress and then blouse-skirt suits in order. For blouse-skirt suits clothing without lining showed higher temperature of the back of microclimate inside clothing than clothing with lining except cotton(p<0.1) 2. There were no significant consistency of the increasing rates of thermal insulation of garment at fabric test and human trials among polyesterand silk.

  • PDF