• Title/Summary/Keyword: mean comfort

Search Result 308, Processing Time 0.027 seconds

Physiological Responses and Wearing Sensation of Different Toes Socks Materials (발가락 양말 소재별 인체생리반응 및 착용감)

  • Lee, Ji-Eun;Kwon, Young-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.7
    • /
    • pp.1056-1064
    • /
    • 2008
  • Toes socks are used widely for the health of feet. However, discomfort is one of the major complains from toes socks users. The purpose of this study is to determine the effect of functional fibers on the physiological response and wearing sensation of toes socks. For experiment, two different toes socks with cotton/warm fiber(WS) and cotton/chitosan fiber(CS) were knitted automatically by a computer controlled flat knitting machine. The control toes socks with cotton/nylon/polyurethan(TS) were prepared to compare the properties. Experiments were conducted in a climate room of $16\pm2^{\circ}C$, $50\pm5%$ R.H. The results of this study were as follows. The change of heart rate, pulse rate, and mean skin temperature showed no difference among three different socks. However, skin temperature of TS was evaluated higher than that of WS and CS. After exercise wearing WS both instep temperature and sole temperature of women tend to higher compared to men. Wet sensation and overall comfort sensation of toes socks were significantly influenced by different fiber contents. Subjects evaluated WS and CS more comfortable than TS.

A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom (교실 천장형 Unit의 위치에 따른 온열환경 평가 연구)

  • Cho, Sung-Woo;Choi, Jeong-Min;Son, Young-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment (실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구)

  • 윤동원;강효석;안병욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

Evaluation of Comfortableness in Railroad Electric Rolling Stock - Focused on Temperature and Humidity - (철도 전동차내의 쾌적성 평가에 관한 연구 - 온도 및 습도를 중심으로 -)

  • 박덕신;배상호;정병철;이주열
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.1
    • /
    • pp.41-48
    • /
    • 2003
  • Most of people spends their times in indoor about 85% of a day. Thus, indoor is more serious than outdoor concerned with the health. We discussed comfortableness in a railroad electric rolling stock, and focused on temperature and humidity. Electric rolling stock is one of major public transportation system because of an increasing in population and heavy traffic problems. The passengers are under the influence of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system in electric rolling stock should be designed for the health and comfort. One of the main aims is to create an acceptable thermal environment without draught problem. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in electric rolling stork is turbulent. Temperature and humidity gradients in electric rolling stock have been studied. And, the difference between mean temperature and rotative humidity measured at 0.7, 0.9, 1.2, 1.7m above the floor. It has been found that temperature and relative humidity with large fluctuations caused more draught complaints.

Investigation on the Shoulder Shapes between Korean and American Women Age over 55 for Apparel (장·노년층 여성의 의복제작을 위한 어깨형태 연구 - 한국인과 미국인의 비교 -)

  • Choi, Mee-Sung
    • Fashion & Textile Research Journal
    • /
    • v.5 no.3
    • /
    • pp.260-266
    • /
    • 2003
  • The objective of this study is to compare the general body measurements and shoulder shapes of Korean and American elderly women to supply basic data for the apparel design. The anthropometrics data was collected including both direct and indirect measurements of 283 women over the age of 55 in Korean and the American women. The statistical methods used for the analysis of measurement data are the T-test, Exploratory data analysis, ANOVA and Duncan-test respectively. The results of the T-test indicated that there is a significant difference in the 14 body measurement items except of waist circumference. The results of exploratory data analysis, an independent relationship between shoulder slope angle and forward shoulder roll of Korean women. On the other hand, there is a dependent relationship that the bigger shoulder slope and forward shoulder roll with wide cross back shoulder of American women. Comparison of mean among the three different age groups, aged 55~59 group shows significant differences in the value of difference between cross back shoulders and horizontal shoulder width. This finding indicates that the wide and forward roll shoulder needs to special pattern making like ease amount and curvature for fit and comfort for women's apparel.

Control of Asymmetrical Tall Buildings under Wind Loading (비대칭 고층건물의 내풍 및 제진 해석)

  • 민경원;김진구;조한욱
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.203-211
    • /
    • 1997
  • In the design of tall building system, the wind loading can be more dominant factor than earthquake loading, and thus, it is important to check the stability and human comfort against wind. Experimental wind tunnel test is usually performed to predict wind behavior of a tall building, however, the test is not cost-effective in the preliminary stage for various structural models of tall building systems. In this regard, the study is focused on the numerical wind analysis of the tall building with and without tuned mass dampers based on the three dimensional model of wind loads and building behavior. As a numerical result, an asymmetrical 102-story tall building is presented to show the results of root mean squares of build responses with and without tuned mass dampers.

  • PDF

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

A software reliability model with a Burr Type III fault detection rate function

  • Song, Kwang Yoon;Chang, In Hong;Choi, Min Su
    • International Journal of Reliability and Applications
    • /
    • v.17 no.2
    • /
    • pp.149-158
    • /
    • 2016
  • We are enjoying a very comfortable life thanks to modern civilization, however, comfort is not guaranteed to us. Development of software system is a difficult and complex process. Therefore, the main focus of software development is on improving the reliability and stability of a software system. We have become aware of the importance of developing software reliability models and have begun to develop software reliability models. NHPP software reliability models have been developed through the fault intensity rate function and the mean value functions within a controlled testing environment to estimate reliability metrics such as the number of residual faults, failure rate, and reliability of the software. In this paper, we present a new NHPP software reliability model with Burr Type III fault detection rate, and present the goodness-of-fit of the fault detection rate software reliability model and other NHPP models based on two datasets of software testing data. The results show that the proposed model fits significantly better than other NHPP software reliability models.

Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season (강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

Analysis of the Characteristics of Thermal Environment Change Due to Urban Stream Restoration (도심 하천 복원에 따른 주변지역 열환경 변화 특성 분석)

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.235-248
    • /
    • 2019
  • The purpose of this study is to quantitatively analyze the effects of a restoration project on the decrease in the temperature in the surrounding areas. The thermal environment characteristics of the investigation area were analyzed using the meteorological data from the Busanjin Automatic Weather System which is closest to the target area. The terrain data of the modeling domain was constructed using a digital map and the urban spatial information data, and the numerical simulation of the meteorological changes before and after the restoration of the stream was performed using the Envi-met model. The average temperature of the target area in 2016 was $15.2^{\circ}C$ and was higher than that of the suburbs. The monthly mean temperature difference was the highest at $1.1^{\circ}C$ in November and the lowest in June, indicating that the temperatures in the urban areas were high in spring and winter. From the Envi-met modeling results, reductions in temperature due to stream restoration were up to $1.7^{\circ}C$ in winter, and decreased to $3.5^{\circ}C$ in summer. The effect of temperature reduction was seen in the entire region where streams are being restored.