• Title/Summary/Keyword: mean comfort

Search Result 310, Processing Time 0.025 seconds

Comparison of Differences on Microclimatic Factors and Human Thermal Sensation between in situ Measurement and Computer Modeling (실측과 컴퓨터 모델링을 통한 미기후 요소 및 인간 열환경지수의 차이 비교 분석)

  • Park, Sookuk;Kong, Hak-Yang;Kang, Hoon
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.1
    • /
    • pp.43-52
    • /
    • 2020
  • For investigating restriction in the use of computer modeling results without adjusting them with measured data, this study analyzed and compared microclimatic aspects and human thermal sensation between in situ measurement and computer modeling using ENVI-met in and around a small urban park of downtown Changwon in May, 2012. In the results, ENVI-met underestimated air temperatures and wind speeds than the measured ones and overestimated relative humidities. In the radiation analysis, ENVI-met overestimated solar radiation from the sky hemisphere and terrestrial radiation from the ground hemisphere and underestimated terrestrial radiation from the sky hemisphere. Also, the differences of mean radiant temperatures with the measured ones reached up to 19.6℃ which could create an 1.2 PMV difference. ENVI-met overestimated up to 2.3 PMV and 4℃ UTCI at 12:00. The difference was shown clearly in PMV than in UTCI. Therefore, when computer modeling is used in urban microclimate and human thermal sensation (comfort) studies the modeling results should be compared with measured data and adjusted adequately to adopt the results to urban and landscape planning and design.

Development and Evaluation of Functional Lab Gowns in Point of Thermoregulation and Thermal Comfort (기능성 실험 가운의 개발 및 평가 -체온조절 및 온열 쾌적성을 중심으로-)

  • 최정화;이주영;김소영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.292-302
    • /
    • 2004
  • The purpose of this study was to evaluate thermal properties of lab gowns developed from the point of safety and work efficiency. We evaluated thermal and subjective responses of subjects wearing functional new lab gowns (Type B, C, D) and a popular lab gown on the market (Type A). Type B was a new lab gown made of woven fabric with functional cuffs. Type C was a new apron made of woven fabric with arm protectors. Type D was a new lab gown made of non-woven material with functional cuffs and openings around the armpits. Temperature in the climatic chamber was set at 19$^{\circ}$C as an indoor temperature in winter and at 24$^{\circ}$C in summer. There were no significant differences in rectal temperature and heart rate among four types of gowns and between two air temperatures for 120 min. Mean skin temperature was much higher in the type A and B than in He type C and D (p .05). In the 19$^{\circ}$C air, clothing microclimate temperature on the back was the highest in the type B and was the lowest in the type C (p .05). Clothing microclimate humidity was not significant differences among gowns. In subjective .esponses, subjects perceived that Type B was the warmest gown in the 19$^{\circ}$C and the hottest and more humid in the 24$^{\circ}$C than other gowns. Inversely, type C was the coolest gown among four gowns. Both in the 19$^{\circ}$C and in the 24$^{\circ}$C, the Type D had gained most responses of being comfortable. In conclusion, the temperature difference of 5$^{\circ}$C was more of an influencing factor than the difference from four types of lab gowns. Secondly, we recommend the manufacturers to make lab gowns with functional cuffs for safety purposes. Thirdly, the spread of the type of apron with arm protector will contribute to increase of the frequency of wearing in summer. Fourthly, it is necessary to study continuously about lab gowns with non-woven materials for researchers exposed to toxic chemical and biological materials.

Thermal and subjective responses by sun hats for farmer in a hot climatic chamber (서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응)

  • 김명주;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.5
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.

A Study on Wear Sensations of Tecel Fabrics in Hot Environments (서열환경 하에서의 텐셀소재 의복의 착용감 연구)

  • 권오경;송민규;이창미
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.3
    • /
    • pp.149-161
    • /
    • 2000
  • The purpose of the study was to examine the effect of Tencel fabrics on physiological reactions of a human body and thermal comfort under the hot environment. The 3 females subjects in their twenties were selected and a wear sensation test of the subjects was performed with four experimental ensembles made of cotton and Tencel fabrics for the study in the hot environment(3$0^{\circ}C$, 70%RH). The resets of the test were summarized as follows: For the mean skin temperature, Tencel garments showed about 0.2$^{\circ}C$-0.4$^{\circ}C$ lower than that of the cotton garment. The temperature of the rectal was 0.2$^{\circ}C$-0.4$^{\circ}C$ lower for Tencel garments than that for the colon garment. In the form of ensembles, the order of rectal temperature of the subjects for both Tencel and cotton ensembles was 1>IV>III>II. In the body weight loss according to garment materials, Tencel had a lower and more uniform than the cotton Thus, it could concluded that if the perspiration took into account, garments made of Tencel can be more ideal than that of the cotton. The heart rate and oxygen consumption appeared to be proportional to each other. For the heart rate, ensemble TI and TII of Tencel were much lower than ensemble CI and CII. For whole enembles except for TIV, Tencel ensembles showed relatively better thermal sensation and comfort sensation than the cotton ensembles. In the fatigue sensation, the reactions of the subjects were “slightly fatigue” and “fatigue” for the cotton, but “neutral” and “slightly fatigue” for Tencel.

  • PDF

A Study on Examination of Indoor Thermal Environment Elements and Thermal Sensation Vote of Log Cabins in Winter Season (통나무집의 동절기 실내 온열환경 요소의 측정과 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Kook, Chan
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.21-27
    • /
    • 2007
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially as the wood has distinctive ecological merits in comparison with reinforced concrete and brick, the buildings made by the wood are acknowledged with its superiority of ecological value. Enough field studies for their thermal environment, however, haven't been done. In this study, to investigate indoor environmental condition and occupants' response to it of Log Cabin in Gyeongsangnam-do Hamyang Country Jirisan Natural Recreation Forest, examination of indoor thermal environment and field subjective evaluation have been done in that fundamental information of thermal environment characteristics can be suggested. The results are following; 1) Thermal environment of the Log Cabins; Indoor and outdoor mean dry bulb temperature were $21.9^{\circ}C$ and $-3.1^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8% and 52.1%. These results are below ASHRAE; dry bulb temp. $22.0^{\circ}C$, humidity 30%, and above domestic standards; dry bulb temp. $18{\sim}20.0^{\circ}C$, humidity $40{\sim}60%$. 2) Result of subjective evaluation; Thermal sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. And humid sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. 3) Result of vertical temperature and humidity; Vertical temperature difference from head to ankle was $0.54^{\circ}C$ which means most occupants may feel comfortable.

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments (1) -Thermophysiological Response of Human Body in Local Cooling- (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest 연구(1) -Local Cooling에 따른 인체의 온열생리학적 특성-)

  • Kwon, Oh Kyung;Kim, Jin-A;Kim, Tae Kyu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.265-271
    • /
    • 2000
  • Heat stress results in fatigue, a decline in strength, alertness., and mental capacity. The problem is compounded when high humidity exists. To help relieve worker heat stress, many types of cooling units are marketed. While workers may experience some cooling, critical body core temperatures often continue to elevate. This study was designed to find the effects of three kinds of cooling vest with portable frozen gel strips on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperature as well as sweat rate and clothing microclimate were measured during 80 min in 5 healthy males. Inquiries were also made into the subjective rating thermal, humidity comfort, and fatigue sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal temperature was the lowest in garb A1, intermediate in garb A, and the highest in garb A2 throughout the experiment. And mean skin temperature was the lowest in garb A, intermediate in garb A1, and the highest in garb A2; (b) Temperature and humidity within clothing (back) were garb in Al, intermediate in garb A, and the highest in garb A2. But the temperature and humidity within clothing (chest) were garb in A, intermediate in garb A1, and the highest in garb A2; (c) Most participants (4 out of 5 persons) answered that they felt more comfortable and fatigueless in garb A1 than in garb A and A2. It is concluded that local cooling in garb A1 of the upper torso could physiological reduce the thermal strain in participants wearing cooling vest.

  • PDF

An Experimental Study on the Effects of Nursing Care According to Change of Position During Labor (분만과정중 산모 체위변경에 따른 간호효과의 실질적 연구)

  • 조원분
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.1
    • /
    • pp.139-151
    • /
    • 1978
  • This study is to observe the effects of nursing care according to change of position for comfort during labor and safe delivery of newborn infants and perturbment women. Fifty antepartal primipara with labor pain who were admitted to the delivery room of H University Medical Center from September 1, 1976 to November 15, 1976 (Estimate Delivery Confinement) were selected for this investigation. Among the 50 parturiencys, the experimental group (28 primipara) were placed in 30 degree upright sitting position and the control group (22 primipara) were placed in the supine position. following placement, both groups were observed. The summarized findings of the study were as follows; 1. There was a noticeably significant difference in the duration of the first stage of labor (defined as 4 cm. dilatation of the cervical os with the fetal presenting part engaged to full or 10 cm. dilatation) , between the two groups. For women in the 30 degree upright sitting position, the first stage of labor was close to 33.66 minutes shorter. than for the women in the supine position. (t : 32.79, D.F : 48, p<0.0,i) 2. Although slight differences were observed between the Apgar Scores of the newborn infants of primipara in the two groups, these were not significant. The mean Apgar Score among the newborn infants of primipara in the 30 degree upright sitting position was 9.64 compared with 9.04 for the newborn infants of primipara in the supine position, a difference of 0.6. (x$^2$= 2.44, D.F : 2, p〉0.05) 3. There was a significant difference in the conformability of the perturbment women between the two groups because the shortened duration of the first stage and the high level of comfort score calculated for six factors (body activity, serving bed pan, serving kidney basin, pushing, deep breathing and perturbment women's feelings), that affect nursing care.

  • PDF

Evaluation of the Thermal Properties of Disposable Coveralls for Railroad Carriage Maintenance Workers (철도 차량 정비 작업자를 위한 일회용 부직포 작업복의 온열적 성능 평가)

  • 최정화;이주영;김소영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.8
    • /
    • pp.1175-1185
    • /
    • 2004
  • This study evaluated thermo-physiological and subjective properties of improved disposable coveralls for railroad carriage maintenance through climatic chamber trials and a filed study. Subjects wore five kinds of disposable coveralls (Type A: a disposable coverall on the market, Type B: a coverall with an improved hood and size-adjustable design, Type C: a coverall with a portable hood, Type D: a coverall with small holes for ventilation, Type E: a sleeveless coverall, Type F: a separated type of coverall with half sleeves) The air temperature in the climatic chamber was set in 9$^{\circ}C$ and 30$^{\circ}C$ For each condition, subjects simulated the railroad work for 120min. and rectal temperature, skin temperatures, clothing microclimate and subjective sensations were measured. The results of chamber trials showed rectal temperature and clothing microclimate did not display significant differences by clothing type. In 30$^{\circ}C$ air temperature, mean skin temperature was higher in Type E and Type F than in Type A(p<0.05) but between the improved coveralls(B-F), we could not find any significant difference. In the case of thermal comfort, the most preferred types were Type B and Type C in 9$^{\circ}C$ and Type F in 30$^{\circ}C$. All subjects felt more comfortable in the improved coveralls than in coveralls of the market (Type A). In field study, workers preferred Type B, Type C and Type F to Type A but the most favorite type differed by the specific type of work. Especially, workers were dissatisfied that Type D tore easily due to lots of small holes around the armpits and Type I did not protect workers' shoulder and arms from oil contamination. According to the climatic chamber trials and field study, the most effective coveralls were Type B and Type C for winter and Type F for summer.

Parent Perspectives of Diagnostic and Monitoring Tests Undertaken by Their Child with Inflammatory Bowel Disease

  • Ho, Shaun Siong Chung;Keenan, Jacqueline Ilene;Day, Andrew Stewart
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.1
    • /
    • pp.19-29
    • /
    • 2021
  • Purpose: To assess parent perspectives of the current and potential future tests for their child with inflammatory bowel disease (IBD). Methods: New Zealand parents of a child with IBD were invited to complete an anonymous online survey. Experiences relating to their child's blood or faecal tests, medical imaging (abdominal ultrasound [US], abdominal computerised tomography [CT] and magnetic resonance enterography) and colonoscopy were collected. Perceived attitudes to potential future testing of urine, saliva, and breath, were sought. Results: Twenty-eight parents, 93% female completed the survey, and 86% were aged between 35 and 54 years. Baseline information was provided by parents for 27 of 28 children, 70.3% had Crohn's disease with a mean disease duration of 2.67 years. Blood tests were the most requested and completed tests, while CT was the least ordered and most refused test. Colonoscopy was rated as the least comfortable and generated the most worry. Explanation of test significantly improved parent's levels of understanding when their child had blood, faecal, imaging (US) or colonoscopy tests. Providing an explanation, test invasiveness and the impact of the blood results may have on their child's treatment significantly improved parents' comfort levels. However, explanation of colonoscopy generated a significant parental concerns. Saliva, urine and blood tests were chosen as the most preferred disease monitoring tests. Conclusion: Parents preferred any tests less invasive than colonoscopy for monitoring their child's IBD. Although providing explanation of their child's tests enhanced parents' understanding, it can also affect parents' levels of concern and comfort.

Comparison of intermaxillary fixation techniques for mandibular fractures with focus on patient experience

  • Kim, Young Geun;Yoon, Sung Ho;Oh, Jae Wook;Kim, Dae Hwan;Lee, Keun Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2022
  • Background: Intermaxillary fixation (IMF) is a technique that allows for the reduction and stabilization of mandibular fractures. Several methods of IMF, such as self-tapping screws or arch bars, have been developed. This study aimed to validate the usefulness of IMF with a self-tapping screw compared to IMF with arch bars with focus on the patients' perspective. Methods: We retrospectively reviewed the medical records of all patients who were treated for mandibular fractures at our hospital between August 2014 and February 2021. A total of 57 patients were enrolled in this study. Thirteen patients were excluded from the analysis: three patients were lost to follow-up, and 10 patients did not undergo IMF. Finally, 44 patients were analyzed, of which 31 belonged to the arch bar group, and 13 belonged to the screw group. Patient discomfort and pain during IMF application and removal were analyzed using a patient self-assessment questionnaire. The surgeon also assessed oral hygiene, IMF stability, and occlusion. Results: We applied IMF to 34 men (77%) and 10 women (23%). The mean age of the patients was 37.3 years. The most common fracture site was the angle (30%), followed by the parasymphysis (25%), the body (23%), the condyle (11%), and the ramus (11%). Patient discomfort and oral hygiene were statistically favorable in the screw group. The IMF application time was statistically shorter in the screw group (p< 0.001). IMF stability was not statistically different between the two groups. The pain score during IMF removal was lower in the screw group (p< 0.001). Conclusion: Compared to arch bars, IMF screws provide more comfort during the IMF period, help maintain favorable oral hygiene, and have a shorter application time. From the patient's perspective, IMF screws are an excellent alternative to conventional arch bars when applicable.