• Title/Summary/Keyword: maximum transfer

Search Result 1,615, Processing Time 0.027 seconds

Enhancement of Mass Transfer Using Piezoelectric Material in Fluid Flow System

  • Kim, Gi-Beum;Chong, Woo-Suk;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun;Jheong, Gyeong-Rak
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.165-170
    • /
    • 2004
  • The purpose of this work was to assess and quantify the beneficial effects of long-term gas exchange, at varying frequencies, for the development of a vibrating intravascular lung assistance device (VIVLAD), for patients suffering from acute respiratory distress syndrome (ARDS). The experimental design and procedure have been applied to the construction of a new device for assessing the effectiveness of membrane vibrations. An analytical solution has been developed for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers, with the intention of gaining insight into how wall vibrations might enhance the performance of the VIVLAD. As a result, the maximum oxygen transfer rate was reached at the maximum amplitude and through the transfer of vibrations to the hollow fiber membranes. The device was excited by a frequency band of 7Hz at various water flow rates, as this frequency was the 2nd mode resonance frequency of the flexible beam. 675 hollow fiber membranes were also bundled, within the blood flow, into the device.

  • PDF

Jet Impingement Heat Transfer on a Pedestal Encountered in Chip Cooling (충돌제트를 이용한 pedestal 형상의 칩 냉각연구)

  • Lee, Dae-Hee;Chung, Seung-Hoon;Chung, Young-Suk;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.124-130
    • /
    • 2001
  • The heat transfer and flow measurements were made on a cylindrical pedestal mounted on a flat plate with a turbulent impinging air jet. The heat transfer coefficient distributions on the flat plate were measured using the shroud-transient technique and liquid crystal was used to measure the surface temperature. The jet Reynolds number (Re) is 23,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, the dimensionless pedestal diameter-to-height (H/D) from 0 to 1.5, the dimensionless 2nd pedestal diameter-to-height ($H/D_2$) from 0 to 0.4 and the distance from the stagnation point to 2nd pedestal (p/D). The results show that for H/D = 0.5 to 1.5, the Nusselt number distributions on the plate surface exhibit a maximum between $r/d\;{\cong}\;1.0$ and 1.5. The presence of the pedestal appears to cause the flow separation and reattachment on the plate surface, which results in the maximum heal transfer coefficient. Also, for p/D = 2.5 and $H/D_2$ = 0.3, the local Nusselt number in the region corresponding to $r/d\;{\cong}\;1.1$ was increased up to 50% compared to that for $H/D_2=0$.

  • PDF

Reduction Characteristics of Oxygen Carrier Particles for Chemical-looping Combustor with Different Fuels (매체순환식 가스연소기용 산소공여입자들의 연료별 연소특성)

  • Ryu, Ho-Jung;Kim, Kyung-Su;Park, Yeong-Seong;Park, Moon-Hee
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.1
    • /
    • pp.45-54
    • /
    • 2009
  • Reduction reactivity and carbon deposition characteristics of three oxygen carrier particles(OCN01, OCN02, OCN03) have been investigated by using hydrogen, methane, syngas, and natural gas as fuels. For all particles, the maximum conversion, the oxygen transfer capacity, and the degree of carbon deposition increased as the reactive carbon contents increased. The reduction rate and the oxygen transfer rate increased as the moles of required oxygen per input gas increased. The change of maximum conversion, reduction rate, oxygen transfer capacity, oxygen transfer rate and degree of carbon deposition for different fuels can be explained consistently by using parameters such as the reactive carbon contents and the moles of require oxygen per input gas.

Rapid Cooling Mechanism Utilizing Acoustic Streaming Generated by Ultrasonic Vibrations (초음파 진동에 의해 발생된 음향유동을 활용한 급속냉각 메카니즘)

  • Loh, Byoung-Gook;Kwon, Ki-Jung;Lee, Dong-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1057-1066
    • /
    • 2006
  • Acoustic streaming Induced by longitudinal vibration at 30 kHz is visualized for a test fluid flow between the stationary glass plate and ultrasonic vibrating surface with particle imaging velocimetry (PIV) To measure an increase in the velocity of air flow due to acoustic streaming, the velocity of air flow in a gap between the heat source and ultrasonic vibrator is obtained quantitatively using PIV. The ultrasonic wave propagating into air in the gap generates steady-state secondary vortex called acoustic streaming which enhances convective cooling of the stationary heat source. Heat transfer through air in the gap is represented by experimental convective heat transfer coefficient with respect to the gap. Theoretical analysis shows that gaps for maximum heat transfer enhancement are the multiple of half wavelength. Optimal gaps for the actual design are experimentally found to be half wavelength and one wavelength. A drastic temperature variation exists for the local axial direction of the vibrator according to the measurement of the temperature distribution in the gap. The acoustic streaming velocity of the test fluid in the gap is at maximum when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which are specifically 6 mm and 12 mm.

Measurement of the Local Heat Transfer Coefficient on a Concave Surface with a Turbulent round Impinging Jet (오목표면에 분사되는 난류원형충돌제트에 대한 국소열전달계수 측정에 관한 연구)

  • Lim, K.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.112-119
    • /
    • 1995
  • Measurements of the local heat transfer coeffcients on a spherically concave surface with a round impinging jet are presented. The liquid crystal transient method was used for these measurements. This method, which is a variation on the transient method, suddenly exposes a preheated wall to an impinging jet while video recording the response of liquid crystals for the measurement of the surface temperature. The Reynolds numbers used were 1,000, 23,000 and 50,000 and the nozzle-to-jet distance was L/d=2, 4, 6, 8, 10. Presented results are compared to previous measurements for flat plate. In the experiment, the local heat transfer Nusselt numbers on a concave surface are higher than those on a flat plate. Maximum Nusselt number at all region occured at L/d=6 and second maximum in the Nusselt number occured at R/d=2 for both Re=50,000 and Re=23,000 in case of L/d=2 and for only Re=50,000 in case of L/d=4. All other cases exhibit monotonically decreasing value of the Nusselt number along the curved surface.

  • PDF

A Study on Optimizing Energy Transfer of Capacitive Switching Antenna (Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구)

  • Kim, Jin-Man;Bang, Jeong-Ju;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

A Study on the Mass Transfer from a Square Cylinder Using Naphthalene Sublimation Technique (나프탈렌승화법을 이용한 사각관 주위에서의 물질전달에 관한 연구)

  • 유성연
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1300-1310
    • /
    • 1990
  • Naphthalene sublimation technique is employed to investigate the mass transfer processes from a square cylinder at various Reynolds numbers and various angles of attack. Distribution of the local mass transfer coefficients on each face of the cylinder changes dramatically with the angle of attack. Such variation of local mass transfer rates closely connected with the complex flow phenomena such as stagnation, acceleration, separation, reattachment and vortex shedding. The average Sherwood number has a minimum value at 12.deg.-13.deg., and a maximum value at a=20.deg.-25.deg. A comparison of present mass transfer measurement with other heat transfer measurements, using the heat/mass transfer analogy, shows good agreement in average transfer rates, same trend but notable differences in local values. Therefore, naphthalene sublimation technique can be adopted to explore heat transfer processes in the complex flow situations, which is considered to be hardly possible with the conventional heat transfer measurements.

Experimental study on the longitudinal load transfer of a shallow tunnel depending on the deformation tunnel face (II) (얕은 터널의 굴진면 변형에 따른 종방향 하중전이 특성에 대한 실험적 연구(II))

  • Kim, Yang Woon;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.499-509
    • /
    • 2016
  • In recent years, the use of underground spaces becomes more frequent and the demands for urban tunnels are rapidly increasing. The urban tunnels constructed in the ground with a shallow and soft cover might be deformed in various forms on the face, which would lead, the tunnels to behavior 3-dimensionally, which may have a great impact on the longitudinal load transfer. The tunnel face might deform in various forms depending on the construction method, overburden and the heterogeneity of the ground. And accordingly, the type and size of the distribution of the load transferred to the ground adjacent to the tunnel face as well as the form of the loosened ground may appear in various ways depending on the deformation form of the tunnel face. Therefore, in this study was conducted model tests by idealizing the deformation behavior of the tunnel face, that were constant deformation, the maximum deformation on the top and the maximum deformation on the bottom. And the test results were analyzed focusing on the deformation of the face and the longitudinal load transfer at the ground above the tunnel. As results, it turned out that the size and the distribution type of the load, which was transferred to the tunnel as well as the earth pressure on the face were affected by the deformation type of the face. The largest load was transferred to the tunnel when the deformation was in a constant form. Less load was transferred when the maximum deformation on the bottom, and the least load was transferred when the maximum deformation on the top. In addition, it turned out that, if the cover became more shallow, a longitudinal load transfer in the tunnel would limited to the region close to the face; however, if the cover became higher than a certain value, the area of the load transfer would become wider.

Turbulent Flow and Heat Transfer in an Annular Passage with Repeated-Ribbed Roughness on Both Walls (양측벽면에 반복돌출형 거칠기가 있는 이중관통로내의 난류운동과 열전달)

  • 안수환;이윤표
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.5
    • /
    • pp.26-36
    • /
    • 1996
  • The fully developed turbulent momentum and heat transfer induced by the square-ribbed roughness elements on both the inner and outer wall surfaces in concentric annuli are studied analytically based on a modified turbulence model. The analytical results of the fuid flow are verified by experiment. The experiment is done with a pitot tube and a X-type hot wire anemometer to measure the time mean velocity profiles, zero shear stress positions, maximum velocity positions and friction factors, and etc. shown in Fig.1. The resulting momentum and heat transfer are discussed in terms of various parameters, such as the radius ratio, the relative roughness, the roughness density, Reynolds number, Nusselt bumber and Prand시 number. The study demonstrates that certain artificial roughness elements may be used to enhance heat transfer rates with advantage from the overall efficiency point of view by investigating turbulent flows and heat transfer in Fig.1.

  • PDF

Study on the Characteristics of Heat Transfer with Array of Multiple Impinging Jet Nozzle (충돌제트 노즐의 다중 배열 형상에 따른 열전달 특성)

  • Kim, D.K.;Son, J.D.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.32-37
    • /
    • 2006
  • In this paper, we present the flow and heat transfer characteristics with the array of impinging jet nozzles by using the numerical computation and experiment. Numerical solutions were obtained for dimensionless gap H=6, dimensionless outlet length L=10 and Reynolds number Re=1500 by using the commercial CFD code, CFX-5. Experimental and numerical results were agreed well with each other. It was found that the impinging jet with circular array nozzles generated the uniform heat transfer area and the maximum heat transfer is higher than rectangular array nozzles for certain parameter sets. It is one of the most important utilities providing steam to turbine in order to supply mechanical energy in thermal power plant. It is composed of thousands of tubes for high efficient heat transfer.

  • PDF