• Title/Summary/Keyword: maximum shear strength

Search Result 610, Processing Time 0.025 seconds

Cyclic flexural behavior of RC members reinforced with Forta-Ferro and Polyvinyl Alcohol fibers

  • Hamed Rajabzadeh Gatabi;Habib Akbarzadeh Bengar;Murude Celikag
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.333-346
    • /
    • 2023
  • This paper presents findings from an experimental study that was focused on evaluating the use of Forta-Ferro (FF) and Polyvinyl Alcohol (PVA) fibers on the response of moderate and special ductility beams under load cycles. For this reason, eight full-scale specimens, identical in geometry, were subjected to gradual cyclic loading. The specimens included two plain concrete beams with medium and special ductility, three beams with medium ductility and stirrup spacing of one-quarter the effective depth (d/4) and three beams with special ductility, and stirrup spacing of one-half the effective depth (d/2), strengthened with FF and PVA fibers separately. The use of fibers was aimed at reducing the amount of shear reinforcement in flexural members. Here, the variation of parameters including the maximum strength, ultimate strength, stiffness, ductility, damage index, energy dissipation, and equivalent damping was studied. Utilizing FF and PVA fibers improved the performance in beams with moderate ductility when compared to those beams with special ductility. Therefore, in special ductility beams, fibers can be used instead of crossties and in moderate ductility beams, fibers can be added to reduce the ratio of shear reinforcement. Furthermore, increasing the stirrup spacing in the moderate ductility beams from d/4 to d/2 and adding 0.6% FF or 1.5% PVA fibers resulted in behavior similar to those of the moderate ductility beam.

Effect of Reinforcement for Web Opening on Shear Strength of Reinforced Concrete Deep Beams (철근콘크리트 깊은 보의 전단 내력에 대한 개구부 보강 효과)

  • Lee, Jong-Kweon;Choi, Yun-Cheul;Lee, Yong-Taeg
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.699-708
    • /
    • 2007
  • Reinforced concrete deep beams are general structural members used as transfer-girder, pile cap, foundation wall and so on. They have a complex stess formation. Generally, failure mechanisms differ from either continuous deep beams or simple supported deep beams. In continuous deep beams, a negative moment is occurred over intermediate support and the location of maximum moment coincide with high shear force. Therefore, failure usually occurs at this region. While on the other hand, in simple supported deep beam, the region of high shear coincides with the region of low moment. The web opening of deep beams for accepting a facility makes shear behaviors of deep beams more complex and gives rise to an expansion of crack around the opening and a decline of shear capacity of deep beams. Therefore, Engineers must determine a delicate reinforcement method to control a crack and increase a shear capacity. The purpose of this report is a computation of an effective reinforcement method through non-linear finite element method by means of adopting various reinforcement method as variables and a computation of shear capacity formula taking an effectiveness of reinforcement into consideration.

Structural Reliability of Thick FRP Plates subjected to Lateral Pressure Loads

  • Hankoo Jeong;R. Ajit Shenoi;Kim, Kisung
    • Journal of Ship and Ocean Technology
    • /
    • v.4 no.2
    • /
    • pp.38-57
    • /
    • 2000
  • This paper deals with reliability analysis of specially orthotropic plates subjected to transverse lateral pressure loads by using Monte Carlo simulation method. The plates are simply supported around their all edges and have a low short span to plate depth ratio with rectangular plate shapes. Various levels of reliability analyses of the plates are performed within the context of First-Ply-Failure(FPF) analysis such as ply-/laminate-level reliability analyse, failure tree analysis and sensitivity analysis of basic design variables to estimated plate reliabilities. In performing all these levels of reliability analyses, the followings are considered within the Monte Carlo simulation method: (1) input parameters to the strengths of the plates such as applied transverse lateral pressure loads, elastic moduli, geometric including plate thickness and ultimate strength values of the plates are treated as basic design variables following a normal probability distribution; (2) the mechanical responses of the plates are calculated by using simplified higher-order shear deformation theory which can predict the mechanical responses of thick laminated plates accurately; and (3) the limit state equations are derived from polynomial failure criteria for composite materials such as maximum stress, maximum strain, Tsai-Hill, Tsai-Wu and Hoffman.

  • PDF

Friction Angle on the Surface of Vertical Ground Anchor in Sand (모래지반내의 연직 지반앵커 표면의 마찰각)

  • 임종철
    • Geotechnical Engineering
    • /
    • v.11 no.4
    • /
    • pp.99-110
    • /
    • 1995
  • In this study, friction angles on the surface of vertical rigid ground anchor in normally consolidated dry sand were measured by model pullout tests in laboratory. Friction angles were obtained from the normal and shear stresses measured along depth of the anchor stir face by attaching several 2-dimensional load cells. Model tests were conducted under the plane strain state and axial symmetric state. From the results of tests, it was concluded that the maximum friction angle on the anchor surface coincides nearly with the maximum angle of stress obliquity on the plane of zero-extension direction obtained by plane strain compression test. This result was made with regard to the strength anisotropy and stress dependency of sand. It showed that when angle of shear resistance of the sand is applied to the friction angle of the anchor surface, the design capacity could be less than the applied force, thus making the anchor unsafe.

  • PDF

An Evaluation of Structural Performance of Reinforced Concrete Column Retrofitted with Grid Type Unit Details of Jacketing Method (격자형 유닛 상세를 가진 단면증설공법으로 보강된 철근콘크리트 기둥의 구조성능평가)

  • Moon, Hong Bi;Lee, Jeong In;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • In the case of columns in buildings with soft story, the concentration of stress due to the difference in stiffness can damage the columns. The irregularity of buildings including soft story requires retrofit because combined load of compression, bending, shear, and torsion acts on the structure. Concrete jacketing is advantageous in securing the strength and stiffness of existing members. However, the brittleness of concrete make it difficult to secure ductility to resist the large deformation, and the complicated construction process for integrity between the existing member and extended section reduces the constructability. In this study, two types of Steel Grid Reinforcement (SGR), which are Steel Wire Mesh (SWM) for integrity and Steel Fiber Non-Shrinkage Mortar (SFNM) for crack resistance are proposed. One reinforced concrete (RC) column with non-seismic details and two columns retrofitted with each different types of proposed method were manufactured. Seismic performance was analyzed for cyclic loading test in which a combined load of compression, bending, shear, and torsion was applied. As a result of the experiment, specimens retrofitted with proposed concrete jacketing method showed 862% of maximum load, 188% of maximum displacement and 1,324% of stiffness compared to non-retrofitted specimen.

Mechanical Properties of Hybrid FRP Rebar (하이브리드 FRP 리바의 역학적 특성)

  • 박찬기;원종필
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.58-67
    • /
    • 2003
  • Over the last decade fiber-reinforced polymer (FRP) reinforcement consisting of glass, carbon, or aramid fibers embedded in a resin such as vinyl ester, epoxy, or polyester has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. But reinforcing rebar for concrete made of FRP rebar has linear elastic behavior up to tensile failure. For safety a certain plastic strain and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. The same should be required for FRP rebar. Thus, the main object of this study was to develop new type of hybrid FRP rebar Also, this study was evaluated to the mechanical properties of Hybrid FRP rebar. The Manufacture of the hybrid FRP rebar was achieved by pultrusion, and braiding and filament winding techniques. Tensile and interlaminar shear test results of Hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

A Study on the Correlation Evaluation of Confining Pressure and Pile-Soil Interface Strength Reduction Factor Using Numerical Analysis (수치해석에 의한 지중 구속압과 말뚝-지반 경계면 강도감소계수 관계 분석)

  • Tae-Gyeom Lee;Jung-Geun Han;Gigwon Hong;Seung-Kyong You
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • In order to evaluate the relationship between the ground confining pressure and the shear characteristics of the pile-soil interface, this study described the comparative results of the existing experimental results and the FEA results using the strength reduction factor. The strength reduction factor was applied to simulate the shear behavior of the pile-soil interface in finite element analysis(FEA). The analysis results showed that the maximum pullout resistance decreased due to the influence of low confining pressure, as the fines content increased. This trend was similar to the previous experimental research, and this FEA model simulated with the interface strength reduction factor was evaluated as reasonable. The analysis results of the variation in the interface strength reduction factor clearly showed that the interface strength reduction factor clearly increased at a high fines content when the confining pressure was 50kPa. However, it was found that the increase rate was low when the confining pressure was 100kPa and 150kPa. Therefore, confining pressure and fines content need to be considered in FEA to evaluate the shear behavior of the pile-soil interface.

Seismic Performance of Special Shear Wall with Modified Details in Boundary Element Depending on Axial Load Ratio (축력비에 따른 수정된 단부 횡보강상세를 갖는 특수전단벽의 내진성능)

  • Chun, Young-Soo;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.7 no.1
    • /
    • pp.31-41
    • /
    • 2016
  • In this paper, we propose experimental results, which target the major variables that influence the structural performance of a wall, as well as the resulting seismic and hysteretic behavior. Results also provide the basis for the application of performance based design by identifying the nonlinear hysteretic behavior of the wall with boundary element details recently proposed in previous study by Chun et al(2011). From the experimental results, the crack and fracture patterns of a specimen, which adopt the proposed boundary element details, showed similar tendencies regardless of whether axial force or high performance steel bars is applied. Furthermore, results show that the maximum strength of the specimen can be predicted accurately based on the design equation proposed by the standard. In addition, with a higher axial force, there is a tendency that both the initial load and maximum strength increase as deformation capacity reduces, requiring consideration of the reduced deformation capacity due to a high axial force. For walls under such high axial forces, using high performance steel bars is a very effective manner of enhancing deformation capacity. Therefore, reinforcing the plastic hinge region with boundary elements using high performance steel bars is preferable.

Characteristics of Deformation and Shear Strength of a Sandy Soil Deposited on the SAEMANKEUM Sea (새만금지역 해상에 퇴적된 사질토의 변형 및 전단강도 특성)

  • Lee, Kang-Il;Ju, Jae-Woo;Lee, Jin-Soo;Choi, Jong-Pyo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.3
    • /
    • pp.29-37
    • /
    • 2010
  • This study aims at evaluating the engineering properties of very poor graded fine sands deposited on the sea. Using materials sampled at SAEMANKEUM area, a series of rowe cell consolidation tests and triaxial compression tests are conducted in order to evaluate the characteristics of deformation and shear strength by the relative density. Prior to those tests, a maximum and a minimum relative densities are obtained. As a result, it appears that the minimum void ratio is 0.88, and the maximum compactible relative density is about 71%. In addition, internal frictional angle appears to increase linearly with an increase of the relative density which is similar to that of the port KUNJANG.

  • PDF

A Study on the Characteristics of Alluvial Clay in Yangsan-Mulgum (양산-물금 충적점토의 토질특성에 관한 연구)

  • 이달원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.1
    • /
    • pp.102-111
    • /
    • 1997
  • Experiments both in laboratory and field were performed to compare and analyze the characteristics of alluvial clay. The alluvial clay was sampled in test site in which large-scaled tests for the part of the site are under process to suggest the rational method for alluvial clay and the criterion for ground settlement monitoring system. The followings were observed through the experiments : 1. Natural water content, plastic limit, and liquid limit of alluvial clay composed of highly fine grains were 40~80%, 10~20%, and 30~55%, respectively. The values of these properties were relatively small at the ground surface, while the values showed maximum at G.L.- l0m and gradually decreased below the level. 2. Shear strength of alluvial clay was proportionally increased to the depth. Unconfined and triaxial compressive strengths were 0.2~0.6kgf/$cm^2$ and 0.1~0.3kgf/$cm^2$, respectively. 3. Compression index and secondary compression index showed maximum values at G.L.-l0m and gradually decreased below the level. The value of consolidation coefficient was relatively large at the ground surface, constant with decreasing the depth, and incresed when G.L. was below -20m. 4. Piezocone test appeared that alluvial clay with N value of 2~4 was uniformly distributed with 20~ 30m thickness from the ground surface, sand seam was nonuniformly distributed, and penetration pore pressure was 0.8 ~ 1 times of the hydrostatic pressure. Undrained shear strength and consolidation coefficient were 0.04 ~ 0.76kgf / $cm^2$ and $2.88{\times} 10{^-4}~1.3{\times} 10{^-2} cm^2/s$ respectively.

  • PDF