• 제목/요약/키워드: maximum power point

검색결과 915건 처리시간 0.036초

일사량 조건을 고려한 태양광 발전의 새로운 MPPT 제어 (A novel MPPT control of photovoltaic considering insolation condition)

  • 정병진;고재섭;최정식;김도연;장미금;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1084_1085
    • /
    • 2009
  • This paper proposes a novel maximum power point tracking(MPPT) control algorithm considering insolation to improve efficiency of PV system. The propoed algorithm is composed perturb and observe(PO) method and constant voltage(CV) method. PO method is simple to realize and CV method is possible to tracking MPP with low insolation. Response characteristics of proposed algorithm is compared to conventional PO method with insolation variation. This paper proves the validity of proposed algorithm through the analysis result.

  • PDF

증분컨덕턴스 제어적용 태양광 인버터 실증시험에 관한 연구 (A Study on Real Test of an Incremental Conductance MPPT Control Based Photovoltaic Inverter)

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1211-1217
    • /
    • 2007
  • In this paper, a 10kVA PV inverter applying Incremental Conductance(IncCond) method for maximum power point tracking WIS developed and its performance tests were carried out. Modeling and simulation of PV array and system controller was performed using PSCAD/EMTDC, an electromagnetic transient analysis program. After comparison and analysis of Perturbation & Observation (P & O) and IncCond method, a PV inverter based on IncCond method was designed and manufactured. Grid interface transient characteristics including start-up, normal operation, and fault operation were tested, which verified the usefulness of the proposed system. In the near future, commercialization process will proceed through additional extensive tests of transients.

Current Control Method of WRSM in High-speed Operation Range

  • Lee, Jae-Jun;Lee, Ki-Doek;Jang, Ik-Sang;Lee, Sung-Gu;Chae, Woong-Chan;Lee, Hyung-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2052-2056
    • /
    • 2015
  • This Paper analyzes the characteristics of the WRSM in high-speed operation range. To verify the control characteritics of various WRSM models, the relative position of the central point of current limit circle and voltage limit ellipse is defined as M value and 3 models according to Mmax value are designed through inductance change. Through the designed models, the current control method of 3-variables control for maximum power especially in high-speed operation range is presented.

Development of a Novel MPPT Algorithm of PV System Considering Radiation Variation

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.56-64
    • /
    • 2012
  • This paper proposes a novel maximum power point tracking (MPPT) control algorithm considering radiation to improve efficiency of PV system. The proposed algorithm is composed perturb and observe (PO) method and constant voltage (CV) method. PO method is simple to realize and CV method is possible to tracking MPP with low radiation. Response characteristics of proposed algorithm are compared to conventional MPPT algorithm such as PO method, IC method and CV method with radiation variation. This paper proves the validity of proposed algorithm through the analysis results.

FVSS-PO를 이용한 태양광 발전시스템의 MPPT 제어 (The MPPT Control oh Photovoltaic System using FVSS-PO Method)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.20-26
    • /
    • 2013
  • This paper proposes the maximum power point tracking(MPPT) control of photovoltaic system using fuzzy based variable step size perturbation & observation(FVSS-PO) method. Conventional PO and incremental conductance(IC)MPPT control algorithm generally uses fixed step size. A small fixed step size will cause the tracking speed to decrease and tracking accuracy of the MPP will decrease due to large fixed step size. Therefore, the fixed step size can't be satisfying both the tracking speed and the tracking accuracy. This paper proposes FVSS-PO MPPT algorithm that adjusts automatically step size of PO by fuzzy control according to operating conditions. The validity of MPPT algorithm proposed in this paper prove through compare with conventional PO MPPT algorithm.

가변속 풍력 발전용 영구자석형 동기발전기의 적응 슬라이딩 모드 제어기 설계 (Adaptive Sliding Mode Controller Design of Permanent Magnet Synchronous Generator for Variable-Speed Wind Turbine System)

  • 김성수;최한호
    • 제어로봇시스템학회논문지
    • /
    • 제22권5호
    • /
    • pp.315-319
    • /
    • 2016
  • This paper proposes a simple adaptive sliding mode control algorithm for controlling a permanent magnet synchronous generator (PMSG) of a MW-class direct-driven wind turbine system. The proposed adaptive sliding mode controller does not require accurate knowledge of the PMSG parameter or turbine torque values. The proposed controller can accurately track the reference angular speed computed by the maximum power point tracking(MPPT) algorithm. Finally, this paper gives Matlab/Simulink simulation results to verify the practicality and effectiveness of the proposed adaptive sliding mode controller.

진행파를 이용한 송전선로의 고장점 표정 알고리즘 (A Fault Location Algorithm for a Transmission Line Using Travelling Waves)

  • 강상희;김진한
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권10호
    • /
    • pp.542-549
    • /
    • 2004
  • The conventional fault location algorithms based on the travelling waves have an inherent problem. In cases of the close-up faults occurring near the relaying point and of the faults having zero degree inception angle of voltage signals, the conventional algorithms can not estimate an accurate fault distance. It is because the shapes of travelling waves are near sinusoidal in those cases. A new method solving this problem is presented in this paper. An FIR(Finite Impulse response) filter which makes high frequency components prominent and makes the power frequency component and dc-offset attenuated is used. With this method, the cross-correlation peak is to be very clear when a close-up fault or a fault having near zero-degree inception angle occurs. The cross-correlation peaks can be clearly distinguished and accurate fault location is practically possible consequently. A series of simulation studies using EMTP(Electromagnetic Transients Program) show that the proposed algorithm can calculate an accurate fault distance having maximum 2% or less error.

감육배관의 파괴거동 평가 (Fracture Behavior Evalustion of Pipes with Local Wall Thinning)

  • 안석환;남기우;김선진;김현수;김진환;도재윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.61-66
    • /
    • 2001
  • Fracture behaviors of pipes with local wall thinning is very important for the integrity of nuclear power plant. In pipes of energy plants, sometimes, the local wall thinning may result from severe drosion-corrosion damage. However, effect of local wall thinning on strength and fracture behaviors of piping system were not well studied. In this paper, the monotonic bending tests were performed of full-scale carbon steel pipes with local wall thinning. A monotonic bending load was applied to straight pipe specimens by four-point loading at ambient temperature without internal pressure. From the tests, fracture behaviors and fracture strength of locally thinned pipe were manifested systematically. The observed failure modes were divided into four types; ovalization, ovalization+cracking, local buckling and local buckling+cracking. Also, maximum load was successfully evaluated.

  • PDF

퍼지제어기에 의한 온도보상효과를 고려한 태양광 발전 시스템의 MPPT제어 특성 (The Characteristic of MPPT Control for Photovoltaic System by Temperature Compensation Effect using Fuzzy Controller)

  • 강병복;차인수;유권종;정명웅;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.238-241
    • /
    • 1995
  • In this paper, a new Maximum Power Point Tractor (MPPT) using Fuzzy Controller is proposed to improve energy convention efficiency. Temperature compensation effect means the photovoltaic voltage is change in condition irradiation, temperature and etc. Fuzzy algorithm is applied to control Boost MPPT converter by Temperature compensation effect. Temperature compensation range is $-40\sim+100^{\circ}C$.

  • PDF

전류형 인버터의 리액터 경감을 위한 태양광발전시스템 (Photovoltaic System for the DC Reactor Reduction of the Current Source Inverter)

  • 박인덕;성낙규;이승환;강승욱;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.484-486
    • /
    • 1997
  • In this paper, we compose of the utility phovoltaic system with the stepdown chopper and the current source inverter to reduce pulsation of dc current and dc reactor. We study that control several ways(twice frequency of utility voltage square pulse and without the chopper) of chopper part. Therefore if voltage across the dc reactor equal to zero, it is decreased. And we control modulation factor of the chopper to operate at maximum power point around of solar cell.

  • PDF