• 제목/요약/키워드: maximum power angle

검색결과 298건 처리시간 0.022초

자가발전효율 향상을 위한 유수관내 블레이드 형상의 모델링 및 해석 (Modeling of Blades to Enhance Self-Power Generation in Pipe Flow)

  • 여인환;김도윤;백종후;이영진;신민철;박재우
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.277-285
    • /
    • 2010
  • We examined the optimal shape of blades and efficiency of a self-power generator when the self-power generator using flow of the water in pipe as the power source was installed. Selected factors were the shape of blades, the number of blades, pitch angle, and the existence of separator. GAMBIT2.4 was used as a modeling program, FLUENT6.3, which is computational fluid dynamics simulation program, was used as an analytical model. In the case of a viscous model, k-epsilon standard model was chosen. As a result, when the number of blades was increased, the efficiency and maximum moment were enhanced slightly. The pitch of blades went up, and maximum moment was also increased. The optimal pitch of blade was 62.5 degree and the efficiency was increased by 30%. The efficiency was also increased when a separator was installed.

교류 전압 제어기에 의한 유도전동기의 효율 개선에 관한 연구 (A Study on the Efficiency Improvement of Induction Motor with AC Voltage Controller)

  • 이승철;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.137-139
    • /
    • 1991
  • This paper proposes a minimum power factor control for maximum efficiency operation of an induction motor, under low load condition. Minimum input or maximum efficiency operation is achived by properly adjusting the amplitude of the stator voltage, with the three phase AC voltage controller. Through the simulation, the relationships between the delay angle and input power under various load conditions are examined. Experimental results are also given, which show good coincidence with the simulation results.

  • PDF

Analysis on How to Locate the Maximum Line Voltage to Hull in Steady State on the Vector Diagram Onboard Vessels

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.966-973
    • /
    • 2011
  • Power distribution onboard vessel is typically configured as ungrounded system due to the ability to continuously supply electric power even when an earth fault occurs. The impedance connections between 3 phase power lines and hull cause the line-to-hull voltages to become unstable and increased in case the impedances are unbalanced, bringing the situation susceptible to electric shock and deterioration of insulation material. Also the line-to-hull voltage can reach to a certain maximum value in the steady state depending on the distributed capacitances and grounding resistances between lines and hull. This study suggests how to find and calculate the maximum line-to-hull voltage in view of magnitude and phase angle based on the vector diagram.

Optimal Excitation Angles of a Switched Reluctance Generator for Maximum Output Power

  • Thongprasri, Pairote;Kittiratsatcha, Supat
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1527-1536
    • /
    • 2014
  • This paper investigates the optimal values of turn-on and turn-off angles, and ratio of flux linkage at turn-off angle and peak phase current positions of optimal control for accomplishing maximum output power in an 8/6 Switched Reluctance Generator (8/6 SRG). Phase current waveform is analyzed to determine optimal excitation angles (optimal turn-on and turn-off angles) of the SRG for maximum output power which is applied from a nonlinear magnetization curve in terms of control variables (dc bus voltage, shaft speed, and excitation angles). The optimal excitation angles in single pulse mode of operation are proposed via the analytical model. Simulated and experimental results have verified the accuracy of the analytical model.

증속 기어 압축기용 스러스트 칼라의 윤활 성능 해석 (Performance Analysis of Oil-lubricated Thrust Collars in Integrally Geared Compressors)

  • 이동현;김병옥;선경호
    • Tribology and Lubricants
    • /
    • 제34권5호
    • /
    • pp.169-174
    • /
    • 2018
  • A multi-stage compressor (MSC) is comprised of several impellers installed in the pinion gear shaft driven by a main bull gear. In the pinion shaft, a thrust collar (TC) is installed to support the thrust load. The TC makes the lubrication system simpler in the MSC; therefore, it is widely used in similar kinds of machinery. Typically, TCs are installed on both sides of the bull gear and pressure is developed in the lubricated area by creating a taper angle on the TC and bull gear surface. In the current study, we developed a numerical analysis model to evaluate the performance of the TC considering its design parameters. We sloved the Reynolds equation using the finite element method and applied the half Sommerfeld condition to consider cavitation. Based on the pressure calculated in the lubricated area, we calculated the power loss and minimum film thickness. In addition, we calculated stiffness and damping using perturbation method. We performed parametric studies using the developed model. The results of the analysis show that the maximum pressure presents in the center area of the TC and it increases with the taper angle. The area over which pressure is developed decreases with the taper angle. The results also show that there is an optimum taper angle providing minimum power loss and maximum film thickness. Additionally, the stiffness and damping decrease with the taper angle. As the applied load increases, the power loss increases and the minimum film thickness decreases. However, the stiffness and damping increase with the applied load.

수직축 풍력발전기의 해석에 관하여 (On the Analysis of Vertical-axis Wind Rotor)

  • 김광호;김정오
    • 대한기계학회논문집
    • /
    • 제3권2호
    • /
    • pp.60-67
    • /
    • 1979
  • Aerodynamic forces acting on a curved blade are computed theoretically taking into account the variation of wind speed over the blade to investigate the performance of a vertical axis wind rotor. It is shown that the rotor does not self start at the rated wind speed without a supplementary starting device and that most of the power output is contributed by the central portion of the rotor, and the use of spoilers for limiting the maximum rotational speed is needed for safety. It is also shown that provision of skew angle to the blade does not improve the starting characterstics and only reduces the maximum power output. The effects of geometric variables such as skew angle, blade solidity and ratio of the rotor height to diameter are also discussed.

SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정 (Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method)

  • 장도현;문진영
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.418-425
    • /
    • 1998
  • 본 논문에서는 위상각 제어에서 주어진 턴온 각에서 최대의 토크를 유지하기 위한 적절한 턴오프 각을 자기동조방식(self-tuning method)에 의해 결정하는 방식을 제안하였다. 엔코더에 의해 샘플링 시간(sampling time)동안 구해진 펄스 수는 바로 이전의 샘플링시간 동안 구해진 펄스 수와 비교하여 턴오프 각을 앞으로 또는 뒤로 이동한다. 이러한 과정을 되풀이함으로서 최대 토크를 발생하는 턴오프 각을 결정하게 된다. 실제 회로에서는 원 칩 마이크로프로세서에 의해 처리되었으며 실험을 통해 턴온 각이 변하더라도 자기동조방식에 의해 턴오프 각을 조정하면 빠른 속도가 유지됨을 보여 주었다.

  • PDF

반고정식 PV 시스템의 운영 스케줄 도출 및 그에 따른 발전 효율 변화 고찰 (Optimal Operation Schedule of Semi-Fixed PV System and Its Effect on PV Power Generation Efficiency)

  • 곽인규;문선혜;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.69-77
    • /
    • 2017
  • The amount of solar irradiation obtained by a photovoltaic (PV) solar panel is the major factor determining the power generated by a PV system, and the array tilt angle is critical for maximizing panel radiation acquisition. There are three types of PV systems based on the manner of setting the array tilt angle: fixed, semi-fixed, and tracking systems. A fixed system cannot respond to seasonal solar altitude angle changes, and therefore cannot absorb the maximum available solar radiation. The tracking system continually adjusts the tilt angle to absorb the maximum available radiation, but requires additional cost for equipment, installation, operation, and maintenance. The semi-fixed system is only adjusted periodically (usually seasonally) to obtain more energy than a fixed system at an overall cost that is less than a tracking system. To maximize semi-fixed system efficiency, determining the optimal tilt angle adjustment schedule are required. In this research, we conducted a simulation to derive an optimal operation schedule for a semi-fixed system in Seoul, Korea (latitude $37.5^{\circ}$). We implemented a solar radiation acquisition model and PV genereation model on MATLAB. The optimal operation schedule was derived by changing the number of tilt angle adjustments throughout a year using a Dynamic Algorithm. The results show that adjusting the tilt angle 4 times a year was the most appropriate. and then, generation amount of PV system increased 2.80% compared with the fixed system. This corresponds to 99% compared to daily adjustment model. This increase would be quite valid as the PV system installation area increased.

해상용 태양광 발전 시스템의 설치 각도에 관한 연구 (A Study on the Installation Angle of the Marine Solar Power Generation System)

  • 오진석;장재희
    • 한국항해항만학회지
    • /
    • 제42권3호
    • /
    • pp.167-176
    • /
    • 2018
  • 해상에서 운용되는 일점계류형 해양플랜트의 태양광 발전 시스템은 독립 전원 체계를 가지고 있으며, 해상 환경, 부조일수 등의 영향으로 안정적인 전력을 공급하는 것이 중요하다. 이러한 이유로 태양광 패널을 여러 방향으로 설치하게 되는데, 이 때 각 패널마다 입사되는 광량이 달라지므로 부분음영현상이 발생하게 된다. 육상용 태양광 발전시스템의 발전량은 위도의 영향을 받으므로 우리나라의 경우 $30{\sim}36^{\circ}$ 사이의 각도로 설치하는 것이 일반적이나, 일점계류형 해양플랜트에 설치되는 태양광 발전 시스템의 경우 부분 음영 현상에 의해 최대전력점이 제어 가능 범위 밖에 존재하는 경우가 발생하게 되고 이는 전력 발전 손실이 된다. 이 때 두 패널의 광량차이를 줄임으로써, 최대 전력점을 MPPT 알고리즘이 추종 가능한 범위에 존재하게 하여 발전 효율을 더 높일 수 있으며, 시뮬레이션 결과 설치각도 $20^{\circ}$에서 가장 높은 발전 효율 가짐을 확인하였다.

다물체 동역학 시뮬레이션을 통한 버스의 전복 시험 규정과 안전성 평가에 관한 고찰 (Review of Regulation for Rollover Test and Evaluation of Safety for Buses by using Simulation of Multi-body Dynamics)

  • 박승운;최요한;이철희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권3호
    • /
    • pp.39-46
    • /
    • 2022
  • In South Korea, to evaluate the rollover safety of domestic vehicles, the maximum slope angle of the vehicle is specified, which is verified by the rollover safety test of driving vehicles. However, the domestic rollover safety test is not suitable for buses, because the small amount of static stability factor (SSF) will invalidate the rollover experimental equation due to the high center of mass position of buses. To solve the above problems, a dynamic model of the bus is prepared with assumptions of mass and suspension spring properties. Subsequently, the maximum slope angle of the model was computed by using the simulation of multi-body dynamics, and the result was compared with actual test results to validate the dynamics model. Also, the rollover Fishhook (roll stability) test was conducted in the simulation for driving model. During the simulation, roll angle and roll rate were calculated to check if a rollover occurred. Through the rollover simulation of buses, the domestically regulated formula for rollover safety and the procedure of rollover test for driving vehicles are evaluated. The conclusion is that the present regulation of rollover test should be reconsidered for buses to ensure to get the valid results for rollover safety.