• 제목/요약/키워드: maximum permissible exposure

검색결과 21건 처리시간 0.033초

일부 제련 및 리사지 사업장에서 공기중 납 노출농도의 변화 (The change of air lead concentrations in litharge making and smelting industries)

  • 최재욱;김남수;조광성;함정오;이병국
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.10-18
    • /
    • 2010
  • To provide necessary information for future environmental monitoring of smelting and litharge making industries in Korea, environmental monitoring dataset of air lead concentration of 4 lead industries(1 primary smelting, 2 secondary smelting and 1 litharge making industry) were analyzed from 1994 to 2007. Data were compared using geometric mean and standard deviation with minimum and maximum values according to year of measurement, type of lead industries and type of operation of lead industries. The geometric mean and standard deviation of air concentration for a total of 1140 samples in all lead industries for overall 14 years were 70.7${\mu}g/m^3$ and 5.51 with minimum of 1${\mu}g/m^3$ and maximum of 9,185 ${\mu}g/m^3$. The overall geometric means of air concentration were above the permissible exposure levels(PEL) until year of 2001 and thereafter they were remained at the level of half of PEL. The geometric means of primary smelting, secondary smelting and litharge making industry for overall 14 years were 21.7${\mu}g/m^3$(number of samples: 353), 82.5${\mu}g/m^3$(number of samples: 357) and 164.2 ${\mu}g/m^3$(number of samples: 430) respectively. In primary smelting industry, the highest geometric mean air concentration was 35.4 ${\mu}g/m^3$ in the secondary smelting operation; followed by casting operation (24.9 ${\mu}g/m^3$) and melting operation (14.9 ${\mu}g/m^3$), respectively. On the other hand, in secondary smelting industries, the highest geometric mean air concentration was 125.4${\mu}g/m^3$ in melting operation; followed by casting operation (90.5${\mu}g/m^3$) and pre-treatment operation (43.4${\mu}g/m^3$), respectively. However, in litharge making industries, there were no significant differences of geometric mean air concentrations between litharge operation and stabilizer operation. The proportion of over PEL (50${\mu}g/m^3$) was highest in litharge industry and followed by secondary smelting industries. However The proportions of over PEL(${\mu}g./m^3.$) were decreased by the years of environmental monitoring. The significant reduction of mean air lead concentration since year of 2000 was observed due to more active environmental engineering control and new introduction of new operation in manufacturing process, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist according to more strict enforcement of occupational and safety law by the government.

붕소 화합물로 처리된 편백목재 시험편의 연소시험에 의한 가스 발생 (Gas Generation by Burning Test of Cypress Specimens Treated with Boron Compounds)

  • 진의;정영진
    • 공업화학
    • /
    • 제29권4호
    • /
    • pp.413-418
    • /
    • 2018
  • 붕산, 5붕산암모늄, 붕산/5붕산암모늄 첨가제로 처리한 편백목재 시험편의 연소가스 발생에 관한 시험을 하였다. 4 wt%의 붕소 화합물 수용액으로 각각 편백목재 시험편에 붓으로 3회 칠하였다. 실온에서 건조시킨 후, 콘칼로리미터(ISO 5660-1)를 이용하여 연소가스를 분석하였다. 그 결과, 붕소 화합물로 처리한 시험편의 두 번째_최대산소 소모율은 0.1067~0.1246 g/s로서 공시험편보다 5.3~18.9% 감소했다. 붕산, 5붕산암모늄으로 처리한 시험편의 비소화면적은 2.0~19.0% 감소하였다. 그러나, 붕산/5붕산암모늄으로 처리된 경우 비감쇠면적이 공시험편보다 21.2% 증가하였다. 붕소 화합물로 처리한 시험편의 최대일산화탄소 농도는 0~25% 감소되었다. 이것은 직업안전위생관리국(Occupational Safety and Health Administration, OSHA) 허용기준의 1.6~2.2배의 치명적인 독성을 발생하는 것으로 측정되었다. 붕소화합물은 일산화탄소 감소에는 효과적이었으나 OSHA의 허용기준에는 미치지 못하였다. 붕소화합물은 편백나무의 연소성을 두 번째_최대산소 소모율에 대하여 5.3~18.9%, 최대일산화탄소 발생에 대하여 0~25% 억제하였다.

Design and Implementation of the RF Systems for Bi-directional Wireless Capsule Endoscopes

  • Moon, Yeon-Kwan;Lee, Jyung-Hyun;Park, Hee-Joon;Lee, Ju-Gab;Ryu, Jae-Jong;Lee, Wu-Seong;Woo, Sang-Hyo;Won, Chul-Ho;Cho, Jin-Ho;Choi, Hyun-Chul
    • 한국멀티미디어학회논문지
    • /
    • 제9권12호
    • /
    • pp.1669-1680
    • /
    • 2006
  • This paper explains that the RF systems for hi-directional wireless capsule endoscopes were designed and implemented. The designed RF systems for a capsule endoscope can transmit the images of intestines from the inside to the outside of a body and the behavior of the capsules can be controlled by an external controller simultaneously. The hi-directional wireless capsule endoscope consists of a CMOS image sensor, FPGA, LED, battery, DC to DC Converter, transmitter, receiver, and antennas. The transmitter and receiver which were used in the hi-directional capsule endoscope, were designed and fabricated with $10mm(diameter){\times}3.2mm(thickness)$ dimensions taking into the MPE, power consumption, system size, signal to noise ratio and modulation method. The RF systems designed and implemented for the hi-directional wireless capsule endoscopes system were verified by in-vivo experiments. As a result, the RF systems for the hi-directional wireless capsule endoscopes satisfied the design specifications.

  • PDF

Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

  • Na Hye Kwon;Hye Sung Park;Taehwan Kim;Sang Rok Kim;Kum Bae Kim;Jin Sung Kim;Sang Hyoun Choi;Dong Wook Kim
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.53-62
    • /
    • 2022
  • In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities using radiation generators. And we investigated the current status of shielding evaluation of domestic industrial radiation generators. According to the statistical data from the Radiation Safety Information System, as of 2022, a total of 7,679 organizations are using radiation generating devices. Among them, 6,299 facilities use these devices for industrial purposes, which accounts for a considerable portion of radiation. The organizations that use these devices evaluate whether the exposure dose for workers and frequent visitors is suitable as per the limit regulated by the Nuclear Safety Act. Moreover, during this process, the safety shields are evaluated at the facilities that use the radiation generating devices. However, the facilities that use radiating devices having energy less than or equal to 6 MV for industrial purposes are still mostly evaluated and analyzed according to the National Council on Radiation Protection and Measurements 49 (NCRP 49) report published in 1976. We have investigated the technical standards of safety management, including the maximum permissible dose and parameters assessment criteria for facilities using radiation generating devices, based on the NCRP 49 and the American National Standards Institute/Health Physics Society N.43.3 reports, which are the representative reports related to radiation shielding management cases overseas.

방사선 누설선량 조사를 통한 방어시설과 누설선량 평가방법에 대한 문제점 연구 : 부산, 경남 지역 CT실을 중심으로 (Indicating the Problem of Shielding Design and the Way of Estimating Radiation Leakage for CT Rooms located through Survey of Radiation Leakage : in the case of Busan and Gyung-nam Area)

  • 양원석;최준혁;신운재;민병인
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.768-777
    • /
    • 2013
  • 이 연구는 CT(computed tomography)검사 중 발생하는 방사선 누설선량(radiation leakage)으로부터 종사자 및 일반인의 피폭을 최소화하기 위한 것이다. 부산, 경남에 위치한 대학병원 7곳과 종합전문요양병원 4곳의 CT실을 대상으로 하였다. 누설선량 측정 장소로는 1) 조정실 내 감시창 벽면의 지면으로부터 3m 높이 2) 조정실 내 특정 지점 3) 조정실 내 종사자 출입문 4) 환자 출입문을 선정하였다. 그 결과 M병원의 종사자 출입문에서 가장 높은 누설선량이 나타났다. 각각의 측정값은 고전적 방법에 의한 주당 최대 누설선량으로 환산하였다. 그 결과 1) $5.97{\pm}0.23$, 2) $0.50{\pm}0.02$, 3) $10.00{\pm}0.11$, 4) $2.37{\pm}0.47$ mR/week로 주당 최대 누설선량 허용치(<100 mR/week)이하였다. 하지만 측정 최대 누설선량을 기록한 M병원의 조정실 내 종사자 출입문을 실험적 방법으로 계산한 결과 $118.31{\pm}17.72$ mR/week(>100 mR/week)로 나타났다. 조정실 지면으로부터 3 m 이상의 높이에서의 누설선량은 조정실내부에 영향을 끼쳤다(p<0.05). 따라서, 누설선량의 피해를 줄이기 위해, 주당 최대 누설선량 산출 방법에 대한 개선과, 조정실 차폐벽의 차폐체를 3 m 이상으로 할 것을 제안 한다.

Increase in the Th1-Cell-Based Immune Response in Healthy Workers Exposed to Low-Dose Radiation - Immune System Status of Radiology Staff

  • Karimi, Gholamreza;Balali-Mood, Mahdi;Alamdaran, Seyed-Ali;Badie-Bostan, Hassan;Mohammadi, Elaheh;Ghorani-Azam, Adel;Sadeghi, Mahmood;Riahi-Zanjani, Bamdad
    • 대한약침학회지
    • /
    • 제20권2호
    • /
    • pp.107-111
    • /
    • 2017
  • Objectives: Radiation is one of the most important sources of free radical (such as reactive oxygen species) production, which plays an essential role in the etiology of over hundred diseases. The aim of the study was to investigate some immune parameters and hematological indices in healthy workers of the Radiology Department, University Hospital of Mashhad, Iran. Methods: The study was performed on 50 healthy workers: 30 radiology staff as the case group and 20 laboratory workers as the control group. The radiation dose received by the radiology staff participating in the study was less than the annual maximum permissible level, 50 millisievert. Hematological parameters, lymphocyte proliferation and cytokine production were studied in both groups. Results: Among healthy radiology workers, the hematological indices did not differ statistically; however, their proliferation indices and $IFN-{\gamma}$ levels showed significant increases in parallel with decreases in the IL-4 levels as compared to controls. The immune system of workers exposed to low-dose ionizing radiation was found to be shifted from a Type 2 to a Type 1 response to promote cellular immunity. Conclusion: Based on our data, exposure to low-dose ionizing radiation may decrease the prevalence, frequency, and recurrence of various cancers and infectious diseases because of an increase in Th1-cell-based response, thus leading to more protection of the human body against tumor cells and foreign agents and possibly increased longevity. However, due to high rate of fluoroscopy use for interventional radiology, we suggest continuing research projects on radiation protection and hazards to prevent irreversible damage. As a recommendation, in future studies, radiology staff with a weakened immunity due to high radiation exposure should be considered as good choices to be treated using acupuncture techniques because acupuncture has been demonstrated to enhance the function and the number of immune cells.

국내 시판 생수의 불소 이온농도 측정 (Fluoride content of bottled water available in South Korea)

  • 김지수;남용태;김세연;전은주;김진범;정승화
    • Journal of Korean Academy of Oral Health
    • /
    • 제42권4호
    • /
    • pp.199-203
    • /
    • 2018
  • Objectives: The market for bottled water is increasing steadily in South Korea. Bottled water contains several naturally occuring minerals, such as calcium, magnesium, sodium, and fluoride. Fluoride is proven to be effective in preventing dental caries. In South Korea, the maximum permissible concentration of fluoride is 2 ppm for bottled water and 1.5 ppm for tap water. The aim of this study was to investigate the fluoride content of different commercially available brands of bottled water in South Korea, and compare the measured fluoride concentration to the concentration written on the label of each brand of bottled water. Methods: Twenty-seven of the 59 different brands of bottled water produced in South Korea were investigated in this study. Three bottles of each brand were purchased from supermarkets, marts, and convenience stores in each region of Korea in August 2016. For each bottled water brand, the fluoride content was measured three times using a fluoride-ion selective electrode (Orion ionplus Fluoride Electrode 9609, Orion Research, USA). The calibration curve was generated using 0.2 and 2 ppm standard solutions, and confirmed using a 1 ppm standard solution. Results: The mean fluoride content of the 27 brands of bottled water was $0.374{\pm}0.332mg/L$ (range=0.040 to 1.172 mg/L). The fluoride content was labeled by the manufacturer, on each of the tested brands of bottled water. In eight brands, the labeled fluoride content differed from the experimental data. The minimum to maximum fluoride content measured from 10 brands showed a variation of 0.3 mg/L or more when compared to the labeled fluoride content. Conclusions: This study investigated the fluoride content of various brands of bottled water produced in South Korea and compared the measured fluoride levels with fluoride information on the bottle labels. To ensure that consumers are suitably informed regarding their exposure to fluoride, correct labelling of fluoride content in bottled water is important.

Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가 (Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking)

  • 김태원;유순미;전수동;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.73-81
    • /
    • 2018
  • 목 적 : 다발성 뇌 전이의 방사선치료 시 jaw tracking(JT)과 fixed jawFJ)를 이용한 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)를 비교하고 유용성을 평가하고자 한다. 대상 및 방법 : JT를 이용하여 치료받은 다발성 뇌 전이(Multiple Brain Metastasis) 환자 중 6개 이상의 종양이 있고 조사면 크기가 $14{\times}14cm^2$ 이상인 환자 10명을 대상으로 하였다. Eclipse(Ver 13.6 Varian, USA)로 JT와 FJ의 전산화치료계획을 각각 수립하였으며, 전자포털영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 감마지수(Gamma Index, 3 mm, 3 %, 95 % 신뢰구간) 및 최대선량차이(Max. Dose Difference)를 측정하였다. 또한 손상위험장기(Organ At Risk, OAR)의 $D_{max}$$D_{mean}$을 산출하고 비교하였으며 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity Index, HI)를 평가하였다. 결 과 : JT와 FJ의 측정값을 평가한 감마지수는 모든 Case에서 허용 기준(3 mm, 3 %, 95 % 신뢰구간)에 충족하였으며, 최대선량차이값은 Leaf End Transmission이 발생하는 영역에서 시계방향(Clockwise, CW)은 최대 98.4 %, 평균 43.6 %, 반시계방향(Counter-Clockwise, CCW)은 최대 67.9 %, 평균 41.0 %로 측정되었다. 손상위험장기는 JT를 사용하였을 때 각 정상장기에 대한 $D_{max}$의 최대값은 15.36 %~74.59 %, 평균값은 2.84 %~39.80 % 감소, $D_{mean}$의 최대값은 27.90 %~65.23 %, 평균값은 7.70 %~41.71 %로 감소하였으며, 처방선량지수와 선량균질지수값은 차이가 없었다. 결 론 : 다발성 뇌 전이에서 VMAT으로 치료할 경우 JT를 이용하면 치료계획용적(Planning Target Volume, PTV)의 선량분포에 영향을 미치지 않으면서 불특정 영역에서 발생하는 방사선의 누설 및 투과로 인한 불필요한 피폭을 감소시키고 정상장기에 더 낮은 선량으로 방사선치료가 가능할 것으로 사료된다.

  • PDF

三重水素($^{3}H$) 放射能의 生理分析에 關한 硏究 (A Study on Bioassay of Tritium($^{3}H$) Radioacitivity)

  • 황선태;오필재;김원식
    • 한국대기환경학회지
    • /
    • 제3권1호
    • /
    • pp.27-33
    • /
    • 1987
  • 삼중수소 ($^{3}H$) 에 관한 환경 및 생물학상의 연구는 1950년대 중반부터 선진국에서 수행되오고 있다. 삼중소소에 대한 잠재적 노출의 경우 통상적 처리절차는 삼중수소의 신체부하량이라고 일컬어지는 이른바 신체내에 축적된 삼중수소의 양을 결정하기 위하여 삼중수소수로서 오줌속에 포함되는 삼중수소 방사능의 생리분석이다. 전신에 있어서 삼중수소의 최대허용신체부하량은 신체조직에 대하여 약 $30{\mu}Ci/{\ell}$ 이다. 생리분석에서 오줌속에 삼중수소를 검출하는데 가장 보편적인 조사준위(照射准尉)는 최대허용신체부하량의 1/10 이다. 이러한 생리분석 연구계획을 위해서는 소광보정(消光補正) 곡선을 그리는 것이 가장 우선적이다. 이것은 검뇨용 오줌의 색깔이 일정하지 않기 때문에 필요한 것이다. 이 경우에서 소광효과는 주로 오줌시료에 의한 섬광빛의 흡수에 기인된다. 소광보정곡선으로 판단된 공식은 통계적 근거에서 최소자승법에 의하여 Y (%) = 0.771 + 1.836 ${\tmes}10^{-4}$X(count)로 얻어졌다. 여기서 Y는 섬광계수 효율로서 약 12%에서 31% 범위의 값으로 나타났다. 본 논문에서는 삼중수소의 생물학적 반감기와 신체계통적으로 분포된 삼중수소에 적용되고 있는 정체(停滯) 공식에 관한 간략한 이론에 관하여 서술된다.

  • PDF

붕소 화합물로 처리된 편백목재의 연소시험에 의한 연기발생 (Smoke Generation by Burning Test of Cypress Plates Treated with Boron Compounds)

  • 정영진;진의
    • 공업화학
    • /
    • 제29권6호
    • /
    • pp.670-676
    • /
    • 2018
  • 붕산, 5붕산암모늄, 붕산/5붕산암모늄 첨가제로 처리한 편백목재 시험편의 연소가스 발생에 관한 시험을 하였다. 15 wt%의 붕소 화합물 수용액으로 각각 편백목재 시험편에 붓으로 3회 칠하였다. 실온에서 건조시킨 후, 콘칼로리미터(ISO 5660-1)를 이용하여 연소가스를 분석하였다. 그 결과, 붕소화합물로 처리한 시험편의 연기성능지수(SPI)는 공시편 보다 1.37~2.68배 증가하였고, 연기성장지수(SGI)는 29.4~52.9% 감소하였다. 그리고 붕소화합물로 처리된 시험편의 연기강도(SI)는 공시편보다 1.16~3.92배 감소되어 연기 및 화재 위험성이 낮아지는 것으로 예상된다. 또한 붕소화합물로 처리한 시험편의 최대일산화탄소($CO_{peak}$) 농도는 공시편보다 12.7~30.9% 감소되었다. 그러나 미국직업안전위생관리국(OSHA) 허용기준(PEL)보다 1.52~1.92배 높은 치명적인 독성을 발생하는 것으로 측정되었다. 붕소화합물은 일산화탄소를 감소시키는 역할을 하였으나 편백목재 자체의 일산화탄소의 생성 농도가 높기 때문에 감소효과에 대한 기대에 미치지 못하였다.