• Title/Summary/Keyword: maximum detection depth

Search Result 52, Processing Time 0.027 seconds

Simulation of Temporal Variation of Acoustic Transmission Loss by Internal Tide in the Southern Sea of Jeju Island in Summer (여름철 제주 남부해역에서 내부 조석에 의한 음파 전달손실의 시간적 변화 모의실험)

  • Kim, Juho;Kim, Hansoo;Paeng, Dong-Guk;Pang, Ig-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.12-19
    • /
    • 2015
  • In this paper, temporal variations of acoustic transmission loss (TL) affected by internal tide are studied by computer simulation using oceanic data measured in the southern sea of Jeju Island in summer. Temperature was measured with depth (bottom depth are nearly 80 m) in two sites near Seogwipo coast every one hour for 25 hours during July 27 and 28, 2009. The periodic fluctuation of temperature due to the internal tide was observed and its vertical displacement was more than 10 m. In order to investigate temporal variation of TL by internal tide, acoustic propagation between two measurement sites (3.8 km distance) was simulated with a source depth of 10 m. TL variation for 1/3 octave band of 100 Hz center frequency highly coincided with tidal period but more complex variation with indistinct tidal period was observed for 1 kHz. Maximun standard deviation of TL variation was 4.2 dB for 100 Hz at 2.8 km distance from a source and it was 3.7 dB for 1 kHz. The tidal variation was also shown in detection range and its maximum variance was less than 1 km. These results imply that temporal variation of TL should be considered for acoustic researches at the southern sea of Jeju Island.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY (아르곤 레이저의 소아치과에서의 임상적 적용)

  • Lee, Mi-Na;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

Trace Organic Contaminants in Sediments from Deep-sea Basin near Dokdo, Korea

  • Yim, Un-Hyuk;Oh, Jae-Ryoung;Hong, Sang-Hee;Li, Dong-Hao;Shim, Won-Joon;Choi, Hye-Kyung;Kim, Eun-Soo;Shim, Jae-Hyung
    • Ocean and Polar Research
    • /
    • v.24 no.4
    • /
    • pp.391-398
    • /
    • 2002
  • Trace organic contaminants in deep-sea sediments near Dokdo were analyzed. Total PAMs concentration ranged 14.8-314 ng/g dry weight and high molecular weight PAHs were dominant. The highest PAHs concentration was detected at A19 which located at Ulleung Basin. Most of organochlorines were under detection limit. Among the detected organochlorines, DDT compounds were dominant and followed by HCHs and HCB. Butyltin compounds and most of organophosphorus pesticides were not detected. Vertical distribution of PAHs showed typical sub-surface maximum and decreasing trends depending on depth. The highest PAHs concentration reached 454ng/g. Some organochlorines, DDT, HCH was detected and also showed decreasing trends. Other target organic pollutants were not detected in core sediments. Abnormally high level of PAHs concentration in A19 was discussed and the input sources were inferred to be the transport of sludge derived pollutant dumped at dumping site 'Byung' by deep current.

Development an Evaluation Tool for Evaluation of Hypertension Prevention and Management Program in Community Health Posts (보건진료소의 고혈압예방 및 관리사업 평가도구 개발)

  • Cho, Won-Jung;Kwon, Myung-Soon
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.2
    • /
    • pp.197-208
    • /
    • 2004
  • Purpose: This study was to develop an effective evaluation tool for evaluation of hypertension prevention and management program(HPMP) in community health posts (CHPs). Method: Evaluation tool composed from the literature review, the field visiting, and the in-depth interviews with the community health practitioners. Result: The evaluation tool had four domains, each with different maximum points:, hypertension prevention (35), hypertension management (40), environment of the CHPs(10), and evaluation system of the HPMP(15). The first domain was hypertension prevention with sub-domains of health education, and early detection of patients with hypertension. The second domain was hypertension management with sub-domains of management of health records of patients, education and counseling, and treatment and follow-up of patients. The third domain was the environment of the CHPs with subdomains of accessibility of CHPs to residents, accessibility of general health data to the public, and availability of health information to the public by multimedia. The fourth domain was the evaluation system of the HPMP with the subdomains of planning of program, formative evaluation, process evaluation, and summative evaluation. Conclusion: The newly developed evaluation tool will contribute not only to plan and set goals for evaluation of HPMP in CHPs.

  • PDF

A study on fine actuating stage for autofocus by using flexure-hinge type lever mechanism (탄성 힌지 타입 레버 메커니즘을 이용한 자동 초점 조절 미세구동장치에 대한 연구)

  • Lee J.S.;Hong S.I.;Kim H.S.;Jang H.K.;Lee K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.665-666
    • /
    • 2006
  • In precision laser microfabrication, focusing is essential to acquire good machining precision and uniform machining quality. If it does not perform, laser machining cannot be realized. So, confocal scanning method with high depth resolution is used for focus detection technique. This paper is concerned with a procedure for design, analysis and performance test of an autofocus fine actuating stage, which is composed of flexure-hinge type lever mechanism and piezoelectric actuator. Through series of analytical design, the stage is simplified as a rigid bodies(lever and main body) and springs(flexure hinges). The simplified model was applied to determine the dimension of flexure hinges and lever. After structural analysis confirmed design requirement, an actual stage was made and verified through an experiment on the static and dynamic characteristics(maximum stroke and 1st natural frequency). The fabricated stage was satisfied with the design requirement.

  • PDF

An Experimental Study on Shielding Apparatus for the Impulse Noise of K2 Rifle (K2소총의 사격음 차폐장치에 관한 실험적 연구)

  • Lee, Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.486-492
    • /
    • 2010
  • This paper studies an experimental analysis of the impulse noise of K2 rifle when its bullet passes through the large tube(length 1.84m, outer diameter 50cm, glass wool & steel). In experiment, the characteristics of the sound of shooting were different according to the way of shooting; the results of the experiment are given below. First of all, the shooting sound was lower in single-shot shooting, when compared to 3rds burst-shot shooting, difference averaging 2.8dB, 4.0dB at maximum. In short, the difference is minuscule. Secondly, the sound of the K2 rifle was diminished when shot in a tube, ranging from 2.7dB to 15.4dB, averaging 8.2dB. Thirdly, the shooting sound of the K2 rifle was diminished as the insertion depth deepened with formulas given in Fig. 5, 6. Fourthly, basic data for excluding sound of the shooting were presented. Lastly, the characteristics of the shooting sound could be equally used as a basic material for developing marksmanship and sharp-shooting detection device.

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

Structural Shape Estimation Based on 3D LiDAR Scanning Method for On-site Safety Diagnostic of Plastic Greenhouse (비닐 온실의 현장 안전진단을 위한 3차원 LiDAR 스캔 기법 기반 구조 형상 추정)

  • Seo, Byung-hun;Lee, Sangik;Lee, Jonghyuk;Kim, Dongsu;Kim, Dongwoo;Jo, Yerim;Kim, Yuyong;Lee, Jeongmin;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.5
    • /
    • pp.1-13
    • /
    • 2024
  • In this study, we applied an on-site diagnostic method for estimating the structural safety of a plastic greenhouse. A three-dimensional light detection and ranging (3D LiDAR) sensor was used to scan the greenhouse to extract point cloud data (PCD). Differential thresholds of the color index were applied to the partitions of raw PCD to separate steel frames from plastic films. Additionally, the K-means algorithm was used to convert the steel frame PCD into the nodes of unit members. These nodes were subsequently transformed into structural shape data. To verify greenhouse shape reproducibility, the member lengths of the scan and blueprint models were compared with the measurements along the X-, Y-, and Z-axes. The error of the scan model was accurate at 2%-3%, whereas the error of the blueprint model was 5.4%. At a maximum snow depth of 0.5 m, the scan model revealed asymmetric horizontal deflection and extreme bending stress, which indicated that even minor shape irregularities could result in critical failures in extreme weather. The safety factor for bending stress in the scan model was 18.7% lower than that in the blueprint model. This phenomenon indicated that precise shape estimation is crucial for safety diagnostic. Future studies should focus on the development of an automated process based on supervised learning to ensure the widespread adoption of greenhouse safety diagnostics.

Detection of the Defect on the Metal Surface Using the Modulated Microwave (변조 고주파에 의한 금속표면 결함 검출)

  • Joo, G.T.;Jung, S.H.;Song, K.Y.;Kim, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.173-179
    • /
    • 1999
  • The defects on the metal surface. such as the ended circular pressed hole. the penetrated circular drilled hole, and the linear hollow lanes have been investigated by means of the microwave. In this experiment, frequency was set at 9.2GHz with 3kHz modulation, and the methods of reflection, transmission, fixed carrier frequency, and mod-demodulated technique have been used for investigating defects. The magnitudes of the microwave signals have been changed at the ended circular pressed hole and the penetrated circular drilled hole. The defect sizes that were estimated from the reflected microwave signals had the dimensions enlarged by twice the original size of the penetrated circular drilled hole and 2.5 times the original size of the ended circular pressed hole. The magnitudes of the reflected microwave signals from the linear hollow lane have increased with expansion of the width of the notch. In the linear hollow lane with the depth of 2.4mm, the reflected microwave signals versus the defect widths had a maximum value at the defect width of 50mm, and in the linear hollow lanes with the depths of 1.2mm and 0.45mm, the reflected microwave signals versus the defects widths had the maximum values each at the defect depths of 55mm.

  • PDF