• Title/Summary/Keyword: maximum cell density

Search Result 427, Processing Time 0.043 seconds

Synthesis of Pd and Pt Based Low Cost Bimetallic Anode Electrocatalyst for Glycerol Electrooxidation in Membraneless Air Breathing Microfluidic Fuel Cell

  • Panjiara, Deoashish;Pramanik, Hiralal
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.38-57
    • /
    • 2021
  • The different weight ratios of Pd to Pt, i.e., 16:4, 10:10, 4:16 in Pd-Pt/C and Pd (20 wt. %) /C electrocatalysts with low metal loading were synthesized for glycerol electrooxidation in an air breathing microfluidic fuel cell (MFC). The cell performance on Pd-Pt (16:4)/C anode electrocatalyst was found best among all the electrocatalysts tested. The single cell when tested at a temperature of 35℃ using Pd-Pt (16:4)/C, showed maximum open circuit voltage (OCV) of 0.70 V and maximum power density of 2.77 mW/㎠ at a current density of 7.71 mA/㎠. The power density increased 1.45 times when cell temperature was raised from 35℃ to 75℃. The maximum OCV of 0.78 V and the maximum power density of 4.03 mW/㎠ at a current density of 10.47 mA/㎠ were observed at the temperature of 75℃. The results of CV substantiate the single cell performance for various operating parameters.

Effectiveness of Flashing Light for Increasing Photosynthetic Efficiency of Microalgal Cultures over a Critical Cell Density

  • Park, Kyong-Hee;Lee, Choul-Gyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.3
    • /
    • pp.189-193
    • /
    • 2001
  • Critical cell density (CCD), the maximum cell concentration without mutual shading in algal cultures, can be used as a new operating parameter for high-density algal cultures and for the application of the flashing light effect on illuminated algal cultures. CCD is a function of average cell volume and light illumination area. The CCD is thus proposed as an index of estimation of mutual shading in algal cultures. Where cell densities are below the CCD, all the cells in photobioreactors can undergo photosysnthesis at their maximum rate. At cell densities over CCD, mutual shading will occur and some cells in the illumination chamber cannot grow photoautotrophically. When the cell concentration is higher than the CCD, specific oxygen production rates under flashing light were higher than those under continuous light. The CCD was found to be a useful engineering parameter for the application of flashing light, particularly in high-density algal cultures.

  • PDF

Development of an Immobilized Adsorbent for In Situ Removal of Ammonium Ion from Animal Cell Culture Media and Its Applications to Animal Cell Culture System : II. Application to Cell Culture System (동물세포 배양액으로부터 암모늄 이온의 동시제거를 위한 고정화 흡착제의 개발과 동물세포 배양 시스템에의 응용 : II. 세포배양 시스템에의 응용)

  • 박병곤;이해익;전계택;김익환;정연호
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.411-417
    • /
    • 1998
  • The possibility of application of membrane type immobilized adsorbent to the fed-batch or perfusion culture system with anchorage-independent cells as well as batch system was investigated. The improvement in cell density and cell viability due to the combination of immobilized adsorbent with each culture system was evaluated for the investigation, and the optimum culture system employing immobilized adsorbent system was suggested based on the results. It was observed that the system with immobilized adsorbent showed better cell growth and cell viability than that without immobilized adsorbent in every operation system of batch, fed-batch, and perfusion. In case of batch system, 200% improvement of maximum cell density was observed in the system where ammonium chloride was added on purpose. And 50% improvement of maximum cell density was observed in the fed-batch system where ammonium ion accumulates significantly, while small increase in maximum cell density was observed in the perfusion system where dilution of waste byproducts exists. Especially, the fed-batch system showed the most significant improvement on cell growth because both compensation of nutrient and removal of ammonium ion occurred simultaneously in the system. Therefore a combined system of immobilized adsorbent and fed-batch operation could be suggested as an optimum system with in situ removal of ammonium ion.

  • PDF

Effects of anode surface area and methylene blue dye treatment on the power density of microbial fuel cell with sponge and carbon nano tube electrode (음극 전극 표면적과 메틸렌블루 염색이 스펀지 탄소나노 튜브 전극 미생물 연료전지의 전력수율에 미치는 영향)

  • Lee, Chae-Young;Park, Su-Hee;Song, Young-Chae;Woo, Jung-Hui;Yoo, Kyu-Seon;Chung, Jae-Woo;Han, Sun-Kee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.883-888
    • /
    • 2012
  • Anode electrode is one of the most important factors in microbial fuel cell (MFC). This study was conducted to investigate the effects of mediator as methylene blue (MB) and electrode surface area on the power density of MFC with sponge and carbon nano tube (CNT) electrode (SC). The SC electrode with MB (MC) showed the maximum power density increased from 74.0 $mW/m^2$ to 143.1 $mW/m^2$. The grid shaped sponge and CNT (GSC) electrode showed the maximum power density of 209.2 $mW/m^2$ due to the increase of surface area from 88.0 to 152.0 $cm^2$. The GSC electrode with MB (GMC) revealed the maximum power density of 384.9 $mW/m^2$ which was 5.2 times higher than that obtained from the MFC with SC. Therefore MB and increase of surface area led to enhance the performance of microbial fuel cell such as power density.

BcI-2 Over-expression Reduced the Serum Dependency and Improved the Nutrient Metabolism in a NS0 Cells Culture

  • Tey Beng Ti;Al-Rubeai Mohamed
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.3
    • /
    • pp.254-261
    • /
    • 2005
  • The over-expression of Bcl-2 has greatly improved the culture period, specific growth rate, and maximum viable cell density of NS0 cells culture under low serum condition. Further analysis of these data suggests that a saturation model of the Monod type can be used to represent the relationships of specific growth rate and initial serum concentration. The ${\mu}_{max}$ and $K_s$ for the Bcl-2 cell line is $0.927day^{-1}\;and\;0.947\%(v/v)$ respectively, which are $21\%$ greate and $7\%$ lower respectively than its control counterpart. Study on the amino acid supplementation revealed that Bcl-2 cell lines possess greater improvement in the specific growth rate and maximum viable cell density compared to the control cell lines. A further increase in the amino acid supplementation has resulted a $17\%$ decrease in specific growth rate and no improvement in maximum viable cell density in the control culture. However, the Bcl-2 cell line exhibited a better growth characteristic in this culture condition compared to that of control cell lines. The higher specific growth rate and maximum viable cell density of the Bcl-2 cell line in medium fortified with serum and MEM EM suggested a more efficient nutrient metabolism compared to that in the control cell line. The low serum and amino acid utilisation rate and the higher cell yield may prove to be important in the development of serum/protein free culture.

Performance Evaluation of Free breathing Fuel Cell by using Synthetic Jet Air Blower (Synthetic Jet Air Blower를 이용한 Free Breathing 연료전지의 성능 평가)

  • Choi, Jong-Pil;Ku, Bo-Sung;Jang, Jae-Hyuk;Seo, Young-Ho;Kim, Byeong-Hee
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2834-2838
    • /
    • 2008
  • An free breathing proton exchange membrane fuel cell (PEMFC) was developed. This paper presents a study of the several effect on the performance of a fuel cell such as air flow rate, opening ratio, and cathode structures. Especially, an air flow rate is critical condition to improve the fuel cell performance. In this paper, we developed a synthetic jet micro air blower to supply high stoichiometric air. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. In comparison with free convection fuel cells, the forced-convection fuel cell which equipped synthetic jet micro air blower brings higher performance and stability for long term test. Also, power consumption of the synthetic jet micro air blower is under 0.3W. The results show that the maximum power density was $188mW/cm^2$ at $400mA/cm^2$. The maximum power density was higher 40% than power density of free convection fuel cell.

  • PDF

High Cell Density Culture of Micro-algal Dunaliella bardawil (미세조류 Dunaliella bardawil의 고농도 세포배양)

  • 정욱진;왕만식;최승인;정병철;김주곤
    • KSBB Journal
    • /
    • v.14 no.2
    • /
    • pp.160-166
    • /
    • 1999
  • High cell density cultivation of microalga Dunaliella bardawil using nitrogen fed-batch cultures was studied in batch flask. Optimum environmental conditions include concentrated nutrients except NaCl and carbon sources, carbon sources, pH, light, agitation, nitrate and phosphate ions. Cell growth, consumption rates of nitrate and phosphate ions were monitored. Optimal conditions for higher cell density were found to be(in the range tested): 5 times concentrated media(1 times-10 times concentrated media) pH 8.0 (7.0-9.0) white light(blue and red light) 15mM of nitrate (0.94-15mM) 250mM $NaHCO_3$ and $CO_2$ gas. However, the addition of phosphate ions did not enhance the algal maximum cell density and specific growth rate. Nitrate was found to be effective for the cell growth. The maximum cell density of fed-batch culture using nitrate ions in $8.955{\times}106$cells/ml after 189hr incubation.

  • PDF

Evaluation of power density in microbial fuel cells using expanded graphite/carbon nanotube (CNT) composite cathode and CNT anode (팽창흑연·소나노튜브 복합 음극과 탄소나노튜브 양극으로 이루어진 미생물 연료전지의 전력수율 평가)

  • Han, Sun-Kee;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.503-509
    • /
    • 2013
  • Electrochemical redox capacity of a microbial fuel cell (MFC) electrode is an important factor in the power density. This study was conducted to investigate the redox capacity of surface modified anode and cathode electrodes by measuring their conductivities. An anode electrode was modified with nitric acid and a cathode electrode was modified with heat treatment. The anode electrode modified with 20 % of the nitric acid concentration showed the highest conductivity of $6.2{\mu}S/cm/g$ and the maximum power density of $306.0mW/m^2$ when used in a MFC. The cathode electrode modified at $472^{\circ}C$ for 18 min showed the highest conductivity of $5.2{\mu}S/cm/g$ and the maximum power density of $276.20mW/m^2$ when used in a MFC. On the other hand, an MFC using both the electrodes showed the highest maximum power density of $408.2mW/m^2$. Meanwhile, a control MFC without modified electrodes generated very small voltage (0.014 mV), so the power density could not be measured.

High Cell Density Culture of Bifidobacterium longum by Cross-flow Filtration (Cross-flow filtration에 의한 Bifidobacterium longum의 고농도 배양)

  • Lee, Myong-Suk;Park, Yun-Hee
    • Applied Biological Chemistry
    • /
    • v.40 no.1
    • /
    • pp.18-22
    • /
    • 1997
  • The conditions for production of high cell density of Bifidobacterium longum were investigated and the cross-flow filtration system was used to remove the inhibitory metabolites, lactic acid and acetic acid. The maximum cell growth was observed with glucose as carbon source at the concentration of 50 g/l at $37^{\circ}C$ with the initial pH 6.5. When B. longum was cultured in a cross-flow filtration system, the maximum cell growth was observed at a dilution rate(D) of $0.31\;h^{-1}$ and the dry cell weight was 16.4 g/l($3.5{\times}10^{10}\;cell/ml$), which was about four times higher than that obtained in the batch culture with pH control.

  • PDF

Medium Recycle Process for the Production of scu-PA from Serum Free Medium (무혈청 배지로부터 scu-PA의 생산을 위한 배지의 재사용 공정에 관한 연구)

  • 김영남;박경유
    • KSBB Journal
    • /
    • v.8 no.1
    • /
    • pp.17-22
    • /
    • 1993
  • $1.96{\times}10^{-5}$(IU/cell/hr) of specific scu-PA production rate was obtained from HEK cells in maintaining ca. $8{\times}10^{5}$(cells/ml) of maximum roll density at 10(ml/hr) of perfusion rate with recycling 20% serum free conditioned media. It can be compared to $4{\times}10^{6}$(cells/ml) of maximum cell density and $4.56{\times}10^{-4}$(IU/cell/hr) of specific production rate in cultivating cells with 1% serum containing medium. Thc conversion ratio of scu-PA to tc-UK increased up to 55% as the recycling ratio increased; however, recycling the used medium seemed to have least negative effect on cell growth. It also showed that the recycling process had definitive advantage of using serum free medium in perfusion cultivation of HEK cell line.

  • PDF