• Title/Summary/Keyword: maximal function

Search Result 410, Processing Time 0.029 seconds

Reflex Eye Movements Induced by Stimulation of the Semicircular Canal Nerve in Rabbits (가토반규관신경자극(家兎半規管神經刺戟)에 의(依)한 반사성안구운동기전(反射性眼球運動機轉)에 관(關)하여)

  • Kim, Ki-Ho
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.75-81
    • /
    • 1968
  • According to recent observations of Cohen et al. the patterns of vestibular eye movements of rabbits are different from those of cats. However, the causes of such difference of the reflex eye movements in these species are not wholly explained. While the accumulated data obtained from cats appear to be established, experimental evidences in rabbits are rather meager. The author had re-examined the reflex eye movements of rabbits and attempted to find a mechanism which causes such difference in the reflex eye movements between two species. In anesthesized rabbit, unilateral individual semicircular canal nerve was stimulated selectively with a fine insulated electrode which was inserted through a hole made on the corresponding osseous canal, under a dissecting microscope. When an individual canal nerve was stimulated, the reflex movements of both eyes were observed, photographed, and recorded kymographically. Extraocular muscles were also studied to find their morphological characteristics and to correlate them with the function of the muscles. 1. At the beginning of the stimulation, both eyes moved to a specific direction depending upon the canal stimulated, and such directional eye movements were sustained during the whole course of stimulation. Amplitude of the eye movement showed graded responses to the increasing frequency of the stimulus, reaching to the maximal response at 200-300 cps. 2. Stimulation of the unilateral horizontal canal nerve caused conjugate eye movements, which was also observed in cats and other species by other investigators. 3. Stimulation of the unilateral vertical canal nerve caused a pattern of non-conjugate eye movements, which are different from those observed in cats. Such different patterns of vestibular eye movements in two different species are ascribable to the functional difference of the inferior and superior oblique muscles.

  • PDF

The Optimal Timing of Markdowns: A Decision Model for Jean Market (가격인하 최적시기 연구: Jean Market을 대상으로 한 Decision Model를 중심으로)

  • 곽영식;김용준;남용식;이진화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.5
    • /
    • pp.606-617
    • /
    • 2002
  • The purpose of this study is to develop a decision model that helps manufacturers and retailers determine the optimal timing of markdown in order to maximize their profit. An optimal timing decision model was developed based on three steps; conjoint measurement, scenario analysis and simulation. Data were collected from the sample of 149 out of 170 undergraduate and graduate students in Seoul in 1997. From the Jeans market, 8 brands; Levi's, lee, Guess, Calvin Klein, Pintos, Get used, MFG, and Basic, were selected as competitors for this study. In the conjoint measurement, respondents estimated the level of preference, from 1 to 100, for each item in which brand, price, style, and colors were used to explain product characteristics. Then, in order to reflect competitive situation in Jeans market, four types of scenarios were developed. In each scenario, simulations were applied to decide optimal timing of markdowns that leads to maximal profitability and sales volume. The profit was calculated based on the equation; Profit = Jean's market volume x market share of each brand - cost, where market volume was obtained by integral calculus for market utility function, and market share by logit value of part-worth from the conjoint analysis. For the purpose of the parsimony of the research, costs and the level of markdown were fixed to 30% of the regular price. In results, the optimal timing decision model identified 3 different types of brands. The brands that do not need to take markdown were Ievi's, MFG, and Basic Jeans characterized by the highest brand power and the highest price zone. The brands that needed to take early markdowns were Guess, Lee, Calvin Klein, and Get Used with the intermediate level of brand power and price. The brand that need late markdown was Pintos with the weakest brand power among the competitors and the lowest price. The optimal range of markdown remains for further research.

A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS WITH CAVITY DESIGN ON FRACTURE OF COMPOSITE RESIN INLAY RESTORED TOOTH (복합레진 인레이 수복시 와동형태에 따른 치아파절에 관한 유한요소법적 연구)

  • Kim, Chull-Soon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.231-254
    • /
    • 1994
  • Fracture of cusp, on posterior teeth, especially those carious or restored, is major cause of tooth loss. Inappropriate treatments, such as unnecessarily wide cavity preparations, increase the potential of further trauma and possible fracture of the remaining tooth structures. Fracture potential may be directly related to the stresses exerted upon the tooth during masticatory function. The purpose of this study is to evaluate the fracture resistance of tooth, restored with composite resin inlay. In this study, MOD inlay cavity prepared on maxillary first premolar and restored with composite resin inlay. Three dimensional finite element models with eight nodes isoparametric solid element, developed by serial grinding-photographing technique. These models have various occlusal isthmus and depth of cavity, 1/2, 1/3 and 1/4 of isthmus width and 0.7, 0.85 and 1.0 of depth of cavity. The magnitude of load was 474 N and 172 N as presented to maximal biting force and normal chewing force. These loads applied onto ridges of buccal and lingual cusp. These models analyzed with three dimensional finite element method. The results of this study were as follows : 1. There is no difference of displacement between width of occlusal isthmus and depth of cavity. 2. The stress concentrated at bucco-mesial comer, bucco-disal comer, pulpal line angle and the interface area between internal slopes of cusp and resin inlay. 3. The vector of stress direct to buccal and lingual side from center of cavity, to tooth surface going on to enamel. The magnitude of vector increase from occlusal surface to cervix. 4. The crack of tooth start interface area, between internal slop of buccal cusp and resin inlay. It progresses through buccopulpal line angle to cervix at buccomesial and buccodistal comer. 5. The influence with depth of cavity to fracture of tooth was more than width of isthmus. 6. It would be favorable to make the isthmus width narrower than a third of the intercuspal distance and depth of cavity is below 1 : 0.7.

  • PDF

The Analysis of Differences in Pulmonary Functions, Jerk Cost, and Ground Reaction Force Depending on Professional and Amateur Dancers in Korea Dance (한국무용 숙련자와 미숙련자에 따른 폐기능, 부드러움, 그리고 지면반력의 차이 분석)

  • Park, Yang-Sun;Kim, Mee-Yea;Lee, Sung-Ro
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.349-357
    • /
    • 2014
  • The purpose of this study was to examine the differences in the performance of dancing motions depending on the level of skill by investigating pulmonary functions, ground reaction force, and jerk cost. The subjects of this study were 12 professional dancers (career: 16 yrs) and 12 amateur dancers (career: 9 yrs) who had similar physical conditions. We selected four motion phases which included the diagonal line motion, the deep flexion motion, the breath motion, and the turn motion with one leg after a small step walking motion, with Goodguri Jangdan. In the experiment, 6 infrared cameras were installed in order to analyze the value of the jerk costs and the force plate form. Finally, we measured the pulmonary functions of the subjects. For data analysis, independent t-tests according to each event, were carried out in the data processing. According to the results of FVC % Predicted, the professional dancers showed greater lung capacities than the amateur dancers, indicating that the level of dancing skill influences lung capacity. Based on the result of the balance test, the professional dancers used more vertical power than did the amateur dancers when performing maximal flexion motion. The professional dancers used a propulsive force of pushing their body forward by keeping the center of body higher while the amateur dancers used a braking power by keeping their bodies backward. When performing medial-lateral movements, the amateur dancers were less stable than the professional dancers. There were no differences in values of jerk costs between the amateur dancers and the professional dancers.

585-nm Pulsed Dye Laser Treatment of Vocal Polyp (585-nm Pulsed Dye LASER를 이용한 성대 폴립의 치료)

  • Choi, Hong-Shik;Lee, Kun-Wayn;Kim, Min-Ho;Kwon, Soon-Ho;Jeon, Ju-Hyun;Kim, Kwang-Moon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • Background and Objectives: The 585-nm pulsed dye laser (PDL) has recently been adopted by otolaryngologists because of its epithelial-sparing properties. Many authors have reported the use of PDL for treatment of various vocal cord lesions. This purpose of this study is to examine the effectiveness of 585-nm PDL in the treatment of vocal polyp. Materials and Methods: Eight patients with vocal polyp were treated with 585-nm PDL from Sep. 2006 to Nov. 2006 in Yong-dong Sevrance hospital. 5 of them went through local anesthesia and 3 of them went through general anesthesia. In order to control laser fiber, flexible digital transnasal laryngoscope was applied under local anesthesia and general anesthesia using LMA, and micromanipulator was used under general anesthesia using endotracheal tube. The evaluations of vocal function was done at pre-and postoperation. Results: All patients improved in the perceptual evaluation of voice after PDL surgery. The aerodynamic study revealed that 5 of 8 patients showed improvement in maximal phonation time, and 6 of 8 showed improvement in mean airflow rate during phonation. The acoustic analysis revealed that all patients showed improvement in Jitter and Shimmer, and 7 of 8 showed improvement in noise to harmony ratio. Conclusion: This study demonstrates promising results in the efficacy of 585-nm PDL for the treatment of vocal polyps, and it illustrates a new option for vocal polyp treatment as well as the advantage of PDL surgery.

  • PDF

Learning and Performance Comparison of Multi-class Classification Problems based on Support Vector Machine (지지벡터기계를 이용한 다중 분류 문제의 학습과 성능 비교)

  • Hwang, Doo-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.1035-1042
    • /
    • 2008
  • The support vector machine, as a binary classifier, is known to surpass the other classifiers only in binary classification problems through the various experiments. Even though its theory is based on the maximal margin classifier, the support vector machine approach cannot be easily extended to the multi-classification problems. In this paper, we review the extension techniques of the support vector machine toward the multi-classification and do the performance comparison. Depending on the data decomposition of the training data, the support vector machine is easily adapted for a multi-classification problem without modifying the intrinsic characteristics of the binary classifier. The performance is evaluated on a collection of the benchmark data sets and compared according to the selected teaming strategies, the training time, and the results of the neural network with the backpropagation teaming. The experiments suggest that the support vector machine is applicable and effective in the general multi-class classification problems when compared to the results of the neural network.

  • PDF

Immediate effects of single-leg stance exercise on dynamic balance, weight bearing and gait cycle in stroke patients

  • Jung, Ji-Hye;Ko, Si-Eun;Lee, Seung-Won
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.49-54
    • /
    • 2014
  • Objective: This study aimed to identify how various applications of weight bearing on the affected side of hemiplegia patients affect the ability of balance keeping of the affected leg and the gait parameters. Design: Cross-sectional study. Methods: Eighteen patients with hemiplegia participated in this study. There were twelve males and six females. This study investigated the effects of the single-leg stance exercise on dynamic balance, weight bearing, and gait ability compared with four conditions. Dynamic balance and weight bearing were measured using the step test (ST) of the affected side in stroke patients. In addition, gait parameters were measured using the optogait system for analysis of the spatial and temporal parameters of walking in stroke patients. Results: This study investigated the effect of the single leg stance exercise on the paralysis side. The ST showed significant findings for all conditions (p<0.05). Therefore, knee extension and flexion exercise on the affected side single-leg stance (condition 4) significantly improved dynamic balance and weight bearing on the affected side (p<0.05). In the condition of moving the knee joint in a single-leg stance was discovered that the stance phase time significantly increased more than in the condition of supporting the maximal voluntary weight on the affected side (p<0.05). Conclusions: Single-leg stance on the paralysis side with knee flexion and extension increased symmetry in weight bearing during stance phase time. This study suggests that single-leg stance exercises augments improved gait function through sufficient weight bearing in the stance phase of the affected side.

Antiestrogen, Trans-Tamoxifen Modulation of Human Breast Cancer Cell Growth

  • Lee, Hyung-Ok;Sheen, Yhun-Yhong
    • Archives of Pharmacal Research
    • /
    • v.20 no.6
    • /
    • pp.572-578
    • /
    • 1997
  • To gain further insight into how antiestrogens modulate cell function, the effects of antiestrogen on cell proliferation were studied in human breast cancer cells. We examined the effects of trans-tamoxifen on the proliferation of three human breast cancer cell lines that differed in their estrogen receptor contents. Trans-tamoxifen $(1{\mu}M)$ markedly inhibited the estrogen stimulated proliferation of MCF-7 human breast cancer cells that contained high levels of estrogen receptor $(1.15{\pm}0.03 pmole/mg protein)$ over that of control. In T47D cells that contained low levels of estrogen receptor $(0.23{\pm}0.05 pmole/mg protein)$, trans-tamoxifen $(1{\mu}M)$ showed minimal inhibition of estrogen stimulated cell proliferation over that of control. MDA-MB-231 cells, that contained no detectable levels of estrogen receptors, had their growth unaffected by trans-tamoxifen treatment. These results showed their sensitivity to growth inhibition by antiestrogen conrrelated well with their estrogen receptor content. Also we examined the effect of antiestrogen on cellular progestrone receptor level as well as plasminogen activator activity in MCF-7 cells. Trans-tamoxifen $(1{\mu}M)$ showed maximal inhibition of estrogen stimulated progestrone receptor level as well as plasminogen activator activity in MCF-7 cells that were stimulated by estrogen. It is not clear whether these inhibitions of progestrone receptor and plasminogen activator activity by estrogen are related to the antiestrogen inhibition of cell proliferation of MCF-7 cells. From the results of this study, it is clearly demonstrated that trans-tamoxifen is an antiestrogen in MCF-7 human breast cancer cells. Our data suggest that the biological effectiveness of trans-tamoxifen appear to result from its affinity of interaction with the estrogen receptor.

  • PDF

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.

Ca2+ Sensitivity of Anoctamin 6/TMEM16F Is Regulated by the Putative Ca2+-Binding Reservoir at the N-Terminal Domain

  • Roh, Jae Won;Hwang, Ga Eun;Kim, Woo Kyung;Nam, Joo Hyun
    • Molecules and Cells
    • /
    • v.44 no.2
    • /
    • pp.88-100
    • /
    • 2021
  • Anoctamin 6/TMEM16F (ANO6) is a dual-function protein with Ca2+-activated ion channel and Ca2+-activated phospholipid scramblase activities, requiring a high intracellular Ca2+ concentration (e.g., half-maximal effective Ca2+ concentration [EC50] of [Ca2+]i > 10 μM), and strong and sustained depolarization above 0 mV. Structural comparison with Anoctamin 1/TMEM16A (ANO1), a canonical Ca2+-activated chloride channel exhibiting higher Ca2+ sensitivity (EC50 of 1 μM) than ANO6, suggested that a homologous Ca2+-transferring site in the N-terminal domain (Nt) might be responsible for the differential Ca2+ sensitivity and kinetics of activation between ANO6 and ANO1. To elucidate the role of the putative Ca2+-transferring reservoir in the Nt (Nt-CaRes), we constructed an ANO6-1-6 chimera in which Nt-CaRes was replaced with the corresponding domain of ANO1. ANO6-1-6 showed higher sensitivity to Ca2+ than ANO6. However, neither the speed of activation nor the voltage-dependence differed between ANO6 and ANO6-1-6. Molecular dynamics simulation revealed a reduced Ca2+ interaction with Nt-CaRes in ANO6 than ANO6-1-6. Moreover, mutations on potentially Ca2+-interacting acidic amino acids in ANO6 Nt-CaRes resulted in reduced Ca2+ sensitivity, implying direct interactions of Ca2+ with these residues. Based on these results, we cautiously suggest that the net charge of Nt-CaRes is responsible for the difference in Ca2+ sensitivity between ANO1 and ANO6.