• Title/Summary/Keyword: maxillary molar

Search Result 659, Processing Time 0.025 seconds

EVALUATION OF PERIODONTAL LIGAMENT CELL VIABILITY IN RAT TEETH ACCORDING TO VARIOUS EXTRA-ORAL DRY STORAGE TIMES USING MTT ASSAY (구강 외 노출시간에 따른 흰쥐 치아 치주인대세포 활성도의 MTT 검색법을 이용한 평가)

  • Jeon, In-Soo;Kim, Eui-Seong;Kim, Jin;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.398-408
    • /
    • 2006
  • The purpose of this study was to verify the usefulness of MTT analysis as a tool of measurement of the periodontal ligament cell viability from the extracted rat molar. A total of 80 Sprague-Dawley white female rat of 4 week-old with a body weight of 100 grams were used. The maxillary left and right, first and second molars were extracted under Ketamine anesthesia. Twenty-four teeth of each group (divided as five groups depending upon the time-lapse after extraction such as Immediate, 10, 20, 40 and 60 minutes) were immersed in $200{\mu}l$ of MTT solution (0.5 mg/ml) and processed for optical density measurements. Another 10 teeth of each group were treated as same as above and sectioned at $10{\mu}m$ for microscopic examination. All measurements values were divided by the value of hematoxylin-eosin staining which represented the volume of each corresponding samples. Immediate and 10 minute groups showed highest MTT values followed by 20, 40, and 60 minutes consecutively. Statistical significance (p<0.05) existed between all groups except in immediate versus 10 minute groups and 40 versus 60 minutes. Histological findings also showed similar findings with MTT results in crystal shape and crystal numbers between the experimental groups. These data indicate that in vivo MTT analysis nay be of value for evaluation of the periodontal ligament cell viability without time- consuming cell culturing processes.

Changes of CGRP immunoreactivity in rat trigeminal ganglion neurons during tooth movement (백서 삼차신경절내 신경세포체의 치아이동에 따른 CGRP 면역염색성의 변화)

  • Park, Chyo-Sang;Park, Guk-Phil;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.607-621
    • /
    • 1997
  • GRP was known as the modulator of Pain transmission in central nervous system and local effector to peripheral tissue causing vasodilation, increased blood flow, modulation of immune sysem, stimulation of endothelial cell proliferation, and stimulation of bone formation. Numerous study, therefore, were done to elucidate involvement of CGRP to tooth movement. To investgate the response of CGRP immunoreactive nerve cells according to cell size in trigeminal ganglion during tooth movement, immunohistochemical study was performed using rat. Experimental rats(9 weeks old, 210 gm) were divided as six groups(normal(n=6), 3 hour group(n=5), 12 hour group(n=4), 1 day group(n=5), 3 day group(n=5), 7 day group(n=5)), and were applied orthodontic force (approximately 30 gm) to upper right maxillary molar. After frozen sections of trigeminal ganglions were immunostained using rabbit antisera, the changes of CGRP immunoreactive cells in regard to cell size distribution(small cell(upto $20{\mu}m$), medium cell($20-35{\mu}m$), large cell(above $35{\mu}m$)) were observed. The results were as follows 1. The percentage of CGRP immunoreactive cells to all nerve cells in trigeminal ganglion was 33.0% in normal control group, was decreased to 24.5% in 1 day group, and was increased to 41.8% in 7 day group. 2. The percentage of small, medium, and large cells expressing CGRP immunoreactivity in normal trigeminal ganglion to all CGRP immunoreactive cells were 51.3%, 44.0%, 4.7%, respectively. 3. The percentage of small cells with CGRP immunoreactivity to all CGRP immunopositive cells was increased in 3 hour and 12 hour groups. 4. The percentage of medium cells with CGRP immunoreactivity was increaed in 3 day and 7 day groups. 5. The percentage of large cells with CGRP immunoreactivity was increaed in 7 day group. Conclusively, the small cells with CGRP immunoreactivity in trigeminal ganglion respond to orthodontic force during initial phase of tooth movement, and later the medium and large cells with CGRP immunoreactivity respond

  • PDF

Relationship between the Malocclusion and Caries Prevalence of Adolescents in Iksan (익산시 청소년의 부정교합과 치아우식 유병률 사이의 연관성)

  • Shin, Gayoung;Ra, Jiyoung;An, Soyoun;Song, Jihyun;Lee, Kwanghee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.3
    • /
    • pp.207-217
    • /
    • 2014
  • The purpose of the present study was to evaluate the relationship between the malocclusion and dental caries in adolescents with permanent dentition. The subjects of the study were 385 adolescents aged 12 to 15 years. Dental Aesthetic Index (DAI) and DMFT index were recorded as clinical indicators of malocclusion and dental caries. The mean Dental Aesthetic Index (DAI) score of the subjects was 12.42 and the mean DMFT index of the subjects was 2.89. Four students (1.04%) were included in the group of orthodontic treatment mandatory, which signifies the handicapping malocclusion. Moreover, the result of gender-specific analysis of the DAI components observed that the prevalence of midline diastema and mandibular overjet were significantly higher among boys (p < 0.05). In 7 components (missing teeth, incisal segment crowding, maxillary anterior irregularity, mandibular anterior irregularity, mandibular overjet, anterior openbite, antero-posterior molar relationship) among the 10 DAI components, abnormal groups showed significantly higher DMFT index than normal groups (p < 0.05). The subjects in the group of definite to handicapping malocclusion (DAI ${\geq}$ 26) showed significantly higher DMFT index than the subjects in the group of minor or no malocclusion (p < 0.01). In addition, the DAI score had significant positive linear correlation with the DMFT index (r = 0.584, p < 0.01). Consequently, the current findings suggested a positive relationship between the malocclusion and caries prevalence. And several specific types of malocclusion were supposed to be significantly correlated with dental caries.

The effects of pregnancy on alveolar bone turnover during experimental tooth movement in rats (백서에서 실험적 치아이동시 임신이 치조골 교체(Turnover)에 미치는 영향에 대한 연구)

  • Kim, Young-Sun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.413-421
    • /
    • 2000
  • The purpose of this study was to observe the effects of pregnancy on the experimental tooth movement and alveolar bone turnover process of Sprague-Dawley female rat. Sixty rats were divided into pregnant-tooth movement group(P-Tm), normal-tooth movement group(N-Tm) and normal group(N). Maxillary first molar appliances were inserted bilaterally and activated to 40grams. To measure the amount of tooth movement, x-ray was taken 2 times after appliance insertion and before sacrifice. Animals were sacrificed at 1,3,7,14 days(N=5). Just after sacrifice, alveolar bones were collected and frozen immediately for biochemical analysis. Tooth movement was assessed cephalometrically and tartrate-resistant acid(TRAP) and alkaline phosphatase (ALP) activities were measured in extracts of paradental alveolar bone. The results were as follows: 1. The amount of tooth movement in P-Tm group was greater than that of N-Tm group(p<0.01). 2. Alveolar bone ALP of normal tooth movement group was not significantly different from the control, TRAP was significantly different from the control(p<0.01). In normal tooth movement group, alveolar bone ALP was increased gradually and peak(day 7) fell off significantly at day 14(p<0.05). The Peak of alveolar bone TRAP(day 7) fell off slightly, sustained day 14(p<0.01). 3. Alveolar bone ALP and TRAP of pregnant tooth movement group were not significantly different from that of normal tooth movement group. In pregnant tooth movement group, alveolar bone ALP was increased at day 3(p<0.01) and fell off significantly at day 7-14, alveolar bone TRAP were increased at day 3 and sustained day 14. 4. The peak of alveolar bone phosphatases in pregnant tooth movement group(day3) preceded the peak in normal tooth movement group(day7) (p<0.01). According to the above results, we suggested that bone resorption activity was increased in alveolar bone of pregnant rat, and the degree of tooth movement in pregnancy may be greater than that of normal group because of high bone turnover of alveolar bone in pregnant rat.

  • PDF

Finite element analysis of effectiveness of lever arm in lingual sliding mechanics (Lingual sliding mechanics의 lever arm 효과에 대한 유한요소분석)

  • Kim, Kyeong-Hee;Lee, Kee-Joon;Cha, Jung-Yul;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.324-336
    • /
    • 2011
  • Objective: The aim of this study was to conduct three-dimensional finite element analysis of individual tooth displacement and stress distribution when a posterior retraction force of 200 g was applied at different positions of the retraction hook on the transpalatal arch (TPA) of a molar, and over different lengths of the lever arm on the maxillary anterior teeth in lingual orthodontics. Methods: A three-dimensional finite element model, including the entire upper dentition, periodontal ligaments, and alveolar bones, was constructed on the basis of a sample (Nissan Dental Product, Kyoto, Japan) survey of Asian adults. Individual movement of the incisal edge and root apex was estimated along the x-, y-, and z-coordinates to analyze tooth displacement and von Mises stress distribution. Results: When the length of the lever arm was 15 mm and 20 mm, the incisal edge and root apex of the anterior teeth was displaced lingually, with a maximum lingual displacement at the lever arm length of 20 mm. When the posterior retraction hook was on the root apex, the molars showed distal displacement. When the length of the lever arm was 20 mm, anterior extrusion was reduced and the crown of the canine displaced toward the buccal side, in which case, the retraction hook was on the edge, rather than at the center, of the TPA. Conclusions: The results of the analysis showed that when 6 anterior teeth were retracted posteriorly, lateral displacement of the canine and lingual displacement of the incisal edge and root apex of the anterior teeth occur without the extrusion of the anterior segment when the length of the lever arm is longer, and the posterior retraction hook is in the midpalatal area.

CROSS-SECTIONAL MORPHOLOGY AND MINIMUM CANAL WALL WIDTHS IN C-SHAPED ROOT OF MANDIBULAR MOLARS (C-shaped canal의 절단면 분석을 통한 근관형태의 변화와 근관과 치아외벽간의 최소거리 분석에 관한 연구)

  • Song, Byung-Chul;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • The C-shaped canal system is an anatomical variation mostly seen in mandibular second molars, although it can also occur in maxillary and other mandibular molars. The main anatomical feature of C-shaped canals is the presence of fins or web connecting the individual root canals. The complexity of C-shaped canals prevents these canals from being cleaned, shaped, and obturated effectively during root canal therapy, and sometimes it leads to an iatrogenic perforation from the extravagant preparation. The purpose of this study was to provide further knowledge of the anatomical configuration and the minimal thickness of dentinal wall according to the level of the root. Thirty extracted mandibular second molars with fused roots and longitudinal grooves on lingual or buccal surface of the root were collected from a native Korean population. The photo images and radiographs from buccal, lingual, apical direction were taken. After access cavity was prepared, teeth were placed in 5.25% sodium hypochlorite solution for 2 hours to dissolve the organic tissue of the root surface and from the root canal system. After bench dried and all the teeth were embedded in a self-curing resin. Each block was sectioned using a microtome (Accutom-50, Struers, Denmark) at interval of 1 mm. The sectioned surface photograph was taken using a digital camera (Coolpix 995, Nikon, Japan) connected to the microscope. 197 images were evaluated for canal configurations and the minimal thickness of dentinal wall between canal and external wall using 'Root Thickness Gauge Program' designed with Visual Basic. The results were as follows : 1. At the orifice level of all teeth, the most frequent observed configuration was Melton's Type C I (73%), however the patterns were changed to type C II and C III when the sections were observed at the apical third. On the other hand, the type C III was observed at the orifice level of only 2 teeth but this type could be seen at apical region of the rest of the teeth. 2. The C-shaped canal showed continuous and semi-colon shape at the orifice level, but at the apical portion of the canal there was high possibility of having 2 or 3 canals 3. Lingual wall was thinner than buccal wall at coronal, middle, apical thirds of root but there was no statistical differences.

Comparison of TheraCal LC, Mineral trioxide aggregate, and Formocresolas pulpotomy agents in rat molar (백서에서 치수절단술에 사용하는 TheraCal LC, MTA 그리고 Formocresol의 비교)

  • Lee, Bin-Na;Song, Young-Sang;Lee, Go-Woon;Kim, Young-Hoon;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Korean Journal of Dental Materials
    • /
    • v.44 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • TheraCal LC, a new light-cured, resin-modified calcium silicate-filled base/liner material, has been introduced as a pulpotomy agent. The aim of this study was to evaluate the capacity of hard tissue formation and pulpal response after pulpotomy with TheraCal LC. Twenty-two 9-week-old male rats were anesthetized, cavities were prepared in maxillary first molars and pulps were capped with formocresol (FC), mineral trioxide aggregate (MTA), and TheraCal LC. Specimens obtained from rats were scanned using a high-resolution micro CT system. The specimens were prepared and evaluated histologically, and immunofluorescence assay was performed to assess the dentin matrix protein-1 (DMP-1) expression. On micro CT analysis, the MTA and TheraCal LC groups showed thicker hard tissue formation than the FC group. On hematoxylin and eosin (H&E) staining, MTA and TheraCal LC groups showed dentine bridge formation with vital pulp beneath the materials. On immunofluorescence analysis, DMP-1 was highly expressed in the TheraCal LC group compared to the FC group. TheraCal LC showed similar capacity to form hard tissue as MTA when it was used as a pulpotomy agent. Because of its good manipulation and faster setting time compared to MTA, TheraCal LC could be considered as a good alternative to MTA.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.