• Title/Summary/Keyword: maxillary anterior implant

Search Result 189, Processing Time 0.048 seconds

임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료 (Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption)

  • 최유성
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

  • Phyo Ei Ei Htay;Richard Leesungbok;Suk Won Lee;Yu-Jin Jee;Kyung Lhi Kang;Sung Ok Hong
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.259-270
    • /
    • 2023
  • PURPOSE. This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS. Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS. There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION. CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.

Periosteum-attached Autogenous Block Bone Graft with Simultaneous Implant Placement on the Anterior Maxilla: A Case Report

  • Seung-Hyun Park;Jongseung Kim;Ui-Won Jung;Jae-Kook Cha
    • Journal of Korean Dental Science
    • /
    • 제17권2호
    • /
    • pp.64-74
    • /
    • 2024
  • This case report presents the long-term radiographic outcomes of a novel approach for simultaneous lateral augmentation and implant surgery. A 60-year-old male patient who required tooth extraction of the maxillary central and lateral incisors due to trauma visited the clinic. After tooth extraction, severe horizontal and vertical deficiencies occurred owing to atrophy of the alveolar ridge, and a simultaneous guided bone regeneration (GBR) procedure was planned along with the installation of two implants. In the present case, a modification of the conventional 'sandwich technique' was used by placing the mixture of autogenous bone chips and xenografts at the outermost layer to maximize the osteogenic potential at the coronal part of augmentation while applying solely xenografts at the inner layer. To enhance volumetric stability, an autogenous block of periosteum harvested from the maxillary tuberosity was incorporated between the two layers. Cone-beam computed tomography was performed at baseline and 3 years after the surgery to compare radiographic outcomes. Dehiscence after fixture installation was successfully observed at the re-entry of the surgery site. Three years after the surgery, average horizontal bone gains of 6.11 mm and 4.12 mm were observed in the maxillary central and lateral incisor areas, respectively. Healthy peri-implant mucosa and well maintained marginal bone levels were observed 8 years after the surgery, meeting the criteria for implant success. The findings of this case suggest that a substantial amount of horizontal bone gain can be obtained with a layered approach using autogenous bone materials and xenografts, highlighting the advantages of incorporating autogenous blocks into the simultaneous GBR procedure.

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • 대한치과교정학회지
    • /
    • 제46권4호
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

상악 무치악 환자에서 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복 증례 (A case of removable partial denture restoration using implant supported surveyed crown in a maxillary edentulous patient)

  • 성시영;최연조;류재준
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.29-36
    • /
    • 2022
  • 상악 무치악 환자의 구강 회복을 계획할 때 치료 방법으로 임플란트를 이용한 고정성 보철 수복과 총의치 수복 또는 임플란트를 이용한 오버덴쳐 등을 고려할 수 있다. 총의치 수복의 경우 추가적인 수술이 필요 없고 상대적으로 경제적이며 임플란트 지지 고정성 보철 수복의 경우 일반적으로 총의치 수복에 비해 기능적인 부분이 우수하지만 임상적으로 임플란트 식립이 어려운 경우가 존재한다. 최근에는 환자의 요구 및 잔존 치조골의 상태 등을 고려하여 부분적으로 임플란트를 식립한 후 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복도 시도되고 있다. 본 증례는 상악 전방부의 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복을 시행한 증례로 심미 및 기능적으로 만족할 만한 결과를 보여 보고하는 바이다.

구개측으로 식립된 상악 전치부 임플란트 환자에서 3D 프린터를 이용한 Gingival mask 수복 증례 (Gingival mask using 3D Printer for a patient with palatally installed implant in maxillary anterior area)

  • 정경식;김나홍;김성용;이용상
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.363-368
    • /
    • 2020
  • 적절하지 않은 위치에 식립된 임플란트의 보철물은 심미적, 기능적 문제를 나타낼 수 있으나 이를 해결하기는 어려운 때가 많다. 이러한 경우에 재식립 혹은 연조직 및 경조직 이식을 포함하는 외과적 방법을 고려해 볼 수 있지만 결과 예측이 힘들며 긴 치유 기간 및 술 후 불편감과 추가적인 수술 비용이 동반된다. 반면, 보철적 방법으로는 치은 색상의 세라믹이 포함된 고정성 보철물을 제작하거나 가철성 보철물인 gingival mask 제작 등을 생각해볼 수있다. 본 증례에서는 80세의 남환이 과도하게 구개측으로 식립된 임플란트로 인한 상순과 보철물 사이의 음식물 저류에 대한 불편감 및 심미적인 부분에 대한 불만족을 주소로 내원하였고, gingival mask를 제작하여 단 기간 내에 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

외상으로 인한 상악 중절치 발치 즉시 임플란트 증례 보고 (Case report of immediate placement of maxillary central incisor due to traumatic injury)

  • 최민식
    • 대한심미치과학회지
    • /
    • 제31권2호
    • /
    • pp.40-46
    • /
    • 2022
  • 상악전치부는 심미적 회복이 가장 중요한 부위이지만 구치에 비해 좁은 협설측 치조골 폭 및 발치시의 치조골 흡수로 인하여, 그만큼 심미적인 결과를 얻기가 어려운 부위이다. 본 증례 보고를 통해 외상으로 인한 상악전치부의 발치 즉시 임플란트 식립을 통해 치조골 및 연조직 소실을 최소화 하며 심미성을 확보하기 위한 고려 사항에 대해 살펴 보고자 한다.

Prediction of the alveolar bone level after the extraction of maxillary anterior teeth with severe periodontitis

  • Hong, Chul Eui;Lee, Ju-Youn;Choi, Jeomil;Joo, Ji-Young
    • Journal of Periodontal and Implant Science
    • /
    • 제45권6호
    • /
    • pp.216-222
    • /
    • 2015
  • Purpose: After extraction, the alveolar bone tends to undergo atrophy in three-dimensions. The amount of alveolar bone loss in the horizontal dimension has been reported to be greater than the amount of bone loss in the vertical dimension, and is most pronounced in the buccal aspect. The aim of this study was to monitor the predictive alveolar bone level following the extraction of anterior teeth seriously involved with advanced chronic periodontitis. Methods: This study included 25 patients with advanced chronic periodontitis, whose maxillary anterior teeth had been extracted due to extensive attachment loss more than one year before the study. Periapical radiographs were analyzed to assess the vertical level of alveolar bone surrounding the edentulous area. An imaginary line connecting the mesial and the distal ends of the alveolar crest facing the adjacent tooth was arbitrarily created. Several representative coordinates were established in the horizontal direction, and the vertical distance from the imaginary line to the alveolar crest was measured at each coordinate for each patient using image analysis software. Regression functions predicting the vertical level of the alveolar bone in the maxillary anterior edentulous area were identified for each patient. Results: The regression functions demonstrated a tendency to converge to parabolic shapes. The predicted maximum distance between the imaginary line and the alveolar bone calculated using the regression function was $1.43{\pm}0.65mm$. No significant differences were found between the expected and actual maximum distances. Likewise, the predicted and actual maximum horizontal distances did not show any significant differences. The distance from the alveolar bone crest to the imaginary lines was not influenced by the mesio-distal spans of the edentulous area. Conclusions: After extraction, the vertical level of the alveolar ridge increased to become closer to the reference line connecting the mesial and distal alveolar crests.

상악 전치부 치간 이개와 구치부 교합지지 상실을 가진 환자에서 교정치료를 동반한 완전 구강회복 증례 (Full mouth rehabilitation on the patient with maxillary anterior diastema and posterior bite collapse with orthodontic treatment)

  • 이선기
    • 구강회복응용과학지
    • /
    • 제38권1호
    • /
    • pp.60-68
    • /
    • 2022
  • 심한 치주염을 가진 환자는 잔존 치조골의 흡수가 증가함에 따라, 병적인 치아 이동이 증가하고 구치부 교합지지 상실의 가능성이 높다. 특히, 상악 전치부에서 병적인 치아 이동이 발생하는 경우, 환자는 심미적인 위축감과 삶의 질 저하를 경험할 수 있다. 중증 치주염 환자에게 교정치료는 새로운 뼈 형성을 촉진하고 치주낭을 감소시키며, 임상적 부착을 얻어 보철 수복에 유리한 결과를 가져옴으로써 이상적인 교합과 기능 회복을 가능하게 한다. 구치부의 교합지지 상실로 인해 전치부 병적 치아 이동이 있는 환자에게 치주치료, 교정치료, 임플란트 치료를 계획함으로써 이상적인 수복공간 확보와 안정적인 교합접촉을 형성하였고, 구치부 교합회복을 통한 기능적인 전악수복을 통해 심미적인 결과를 얻었다.

다층 지르코니아를 이용한 임플란트 전치부 수복 증례 (Restoration of anterior teeth with dental implant using multilayer zirconia)

  • 이성희;이영후;홍성진;백장현;노관태;배아란;권긍록;김형섭
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.469-477
    • /
    • 2021
  • 상악 전치부 임플란트의 성공적인 수복을 위해서는 pink esthetics와 white esthetics가 모두 충족되어야 한다. Pink esthetics 부분의 경우 적절한 임시보철물의 역할이 중요하고, white esthetics 부분의 경우에는 최종 보철물의 색상과 형태가 중요하다. 다층 지르코니아는 기존의 단일구조 지르코니아에 비해 절단 부위의 투명도가 높기 때문에 추가적인 도재 축성 없이 자연스러운 보철물 제작이 가능하다. 따라서 본 증례에서는 상악 전치를 상실한 환자에서 적절한 임시보철물을 통해 기능과 심미성을 충분히 회복한 후 다층 지르코니아를 통해 white esthetics를 달성하였다.