• Title/Summary/Keyword: max-n

Search Result 888, Processing Time 0.031 seconds

The availability for cardiorespiratory fitness measurement by 20 m shuttle run test in different sports type of elite athletes. Exercise Science (엘리트 선수들의 운동특성에 따른 20 m 셔틀런 검사의 유용성)

  • Kim, J.K.;Lee, N.J.;Lee, M.S.
    • Exercise Science
    • /
    • v.21 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • This study is to evaluate the availability of cardiorespiratory fitness measurement by 20 m shuttle run test based upon energy contribution rates of elite athletes in different sports type. Sixty-seven elite athletes attending K national university participated in this study. They were divided by three groups based upon sports type, composed of Anaerobic Group (sprint, jumps, weightlifting, throw; n=35), Aerobic Group (medium-long distance; n=9), and Combat Sport Group (judo; n=23). 20 m shuttle run test was conducted by Leger et al.(1982) method and calculating acceleration using measured shuttle run repetitions was conducted by Brewer et al.(1988) method. To test the usefulness of VO2max, graded exercise treadmill test was conducted and standing long jump and 50 m run were measured as power fitness factors. Z-jump was used for measuring power, agility, and muscular endurance. Standing long jump and 50 m run of Anaerobic Group (AnG) was significantly higher than that of Aerobic Group (AeG) and Combat Sport Group (CG) (p<0.05). However, Z-jump of CG was significantly higher than that of AnG and AeG(p<.05). There was a higher correlation of 20 m shuttle run test and VO2max in AnG(r= 0.577, p<.0001) and CG(r= 0.760, p<.0001). Otherwise, there was a low correlation of 20 m shuttle run test and VO2max in AeG. There was no significant group difference to test the availability of 20 m shuttle run test and there was a reduced error when converting 20 m shuttle run results into VO2max. This study examined the usefulness of 20 m shuttle run test by converting 20 m shuttle run repetition results into VO2max calculation, which showed reduced error. Therefore, this study confirmed that it would be needed to convert 20 m shuttle run results into VO2max for universal and practical use in the field without dividing sports type.

The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement (갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가)

  • Lee, Hyun-Kuk;Khang, Hyun Soo;Yang, Seoung-Oh;Han, Man-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

WLAN / WiMAX testing to support the implementation and analysis of MIH Enterprises (WLAN / WiMAX를 지원하는 MIH 기업망 테스트)

  • Yi, Gyu-Sun;Na, Eun-Chong;Lee, Sung-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06d
    • /
    • pp.291-293
    • /
    • 2012
  • 급격히 증가하는 모바일 디바이스에 의한 모바일 데이터 요구량을 처리하기 위해 가장많이 고려되고 있는 IEEE 802.11의 WLAN은 셀룰러보다 높은 데이터 전송속도를 제공하지만 이동성이 고려되어있지 않다. 이에 본 논문에서는 Enterprise WLAN에서 IEEE 802.21 MIH 표준에 기반하여 Media Independent Information Server (MIIS)로부터 수신된 주변 AP들의 네트워크의 정보를 바탕으로 후보 엑세스 AP 네트워크를 선정 및 WiMAX에 make-before-break 핸드오버하는 방안을 제안한다. 제안하는 방안은 실제 Enterprise WLAN와 Mobile WiMAX 환경에서 이동하는 단말의 시간에 따른 TCP throughput에 대한 성능평가를 하였다. 이를 통해 제안하는 방안의 평균TCP throughput 성능이 9.04Mbits/s으로 기존 방안의 TCP throughput 성능 6.49Mbits/s보다 약 40%향상됨을 확인하였다.

Bioequivalence Evaluation of Senafen Tablet and Airtal Tablet Containing Aceclofenac 100 mg (아세클로페낙(100mg) 제제인 세나펜 정과 에어할 정의 생물학적동등성 평가)

  • 박은우;송우헌;차영주;최영욱
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.423-428
    • /
    • 1998
  • Aceclofenac is an orally effective non-steroidal anti-inflammatory agent of the phenylacetic acid derivative. Bioequivalence study of two aceclofenac preparations, the test drug (Senafe $n_{R}$: Daewon Phar-maceutical Company) and the reference drug (Airta $l_{R}$: Daewoong Pharmaceutical Company), was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Sixteen healthy male volunteers, 24$\pm$4 years old and 63.9$\pm$6.9 kg of body weight in average, were divided randomly into two groups and administered the drug orally at the dose of 100 mg as aceclofenac in a 2$\times$2 crossover study. Plasma concentrations of aceclofenac were monitored by HPLC method for 12 hr after administration. AU $Co_{-12h}$ (area under the plasma concentration-time curve from initial to 12 hr) was calculated by the linear trapezoidal method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{msx}$) were compiled directly from the plasma drug concentration-time data. Student's t-test indicated no significant differences between the formulations in these parameters. Analysis of variance (ANOVA) revealed that there are no differences in AU $Co_{12h}$, $C_{max}$ and $T_{max}$ between the formulations. The apparent differences between the formulations were far less than 20% (e.g., 0.25, 0.01 and 7.32 for AU $Co_{-12h}$, $C_{max}$. and $T_{max}$, respectively). Minimum detectable differences (%) between the formulations at $\alpha$=0.05 and 1-$\beta$=0.8 were less than 20% (e.g., 14.65, 12.47 and 15.46 for AU $Co_{-l2h}$, $C_{max}$ and $T_{max}$, respectively). The 90% confidence intervals for these parameters were also within $\pm$ 20% (e.g.,-10.19~10.68, -8.87~8.89 and -3.69~ 18.33 for AU $Co_{-12h}$, $C_{msx}$ and $T_{max}$, respectively). These results satisfy the bioequivalence criteria of KFDA guidelines, indicating that two formulations of aceclofenac are bioequivalent.quivalent.ivalent.ent.t.ent.

  • PDF

Effect of Processing Gain on the Iterative Decoding for a Recursive Single Parity Check Product Code (재귀적 SPCPC에 반복적 복호법을 적용할 때 처리 이득이 성능에 미치는 영향)

  • Chon, Su-Won;Kim, Yong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9C
    • /
    • pp.721-728
    • /
    • 2010
  • CAMC (constant amplitude multi-code) has a better performance of error correction in iterative decoding than SPCPC (single parity check product code). CAMC benefits from a processing gain since it belongs to a spread spectrum signal. We show that the processing gain enhances the performance of CAMC. Additional correction of bit errors is achieved in the de-spreading of iteratively decoded signal. If the number of errors which survived the iterative decoding is less than or equal to ($\sqrt{N}/2-1$), all of the bit errors are removed after the de-spreading. We also propose a stopping criterion in the iterative decoding, which is based on the histogram of EI (extrinsic information). The initial values of EI are randomly distributed, and then they converge to ($-E_{max}$) or ($+E_{max}$) over the iterations. The strength of the convergence reflects how successfully error correction process is performed. Experimental results show that the proposed method achieves a gain of 0.2 dB in Eb/No.

The Biochemical Characterization of D-Hydroxyisovalerate Dehydrogenase, a Key Enzyme in the Biosynthesis of Enniatins

  • Lee, Chan; Zocher, Rainer
    • BMB Reports
    • /
    • v.29 no.6
    • /
    • pp.493-499
    • /
    • 1996
  • The biochemical properties of purified D-hydruxyisovalerate dehydrogenase from Fusarium sambucinum was elucidated. D-Hydroxyisovalerate dehydrogenase produced solely D-hydroxyisovalerate from 2-ketoisovalerate. The isoelectric point of the purified enzyme was 7.0. The enzyme was highly specific with 2-ketoisovalerate ($K_{m}=0.188$ mM, $V_{max}=8.814$ mmol/min mg) and 2-keto-3-methyl-n-valerate ($K_{m}=0.4$ mM, $V_{max}=1.851$ mmol/min mg) for the reductive reaction. This was also seen by comparing D-hydroxyisovalerate ($K_{m}=1.667$ mM, $V_{max}=0.407$ mmol/min mg) and D-hydroxy-3-methyl-n-valerate ($K_{m}=6.7$ mM, $V_{max}=0.648$ mmol/min mg) for the oxidative reaction. Thiol blocking reagents, such as iodoacetamide, N-ethylmaleimide and p-chloromecuribenzoate inhibited about 80% of enzyme activity at 0.02 mM, 50 mM and 50 mM, respectively. The enzyme activity was also inhibited by the addition of 0.1 mM of various metal ions, such as $Fe^{2+}$ (67%), $Cu^{2+}$ (88%), $Zn^{2+}$ t (76%) and $Mg^{2+}$ (9%). The enzyme was stable over three months in 50 mM potassium phosphate buffer (pH 5~7) at $-80^{\circ}C$. However the purified enzyme lost 30% of its activity in the same buffer after 24 h at $4^{\circ}C$. The studies about thermal inactivation of D-hydroxyisovalerate dehydrogenase exhibit 209.2 kJ/M of activation enthalpy and 0.35 kJ/mol K of activation entropy.

  • PDF

The Development of Prediction Equation for Estimating VO2max from the 20 m PSRT in Korean Middle-School Girls. Exercise Science (20 m 점증 왕복달리기 검사를 이용한 여중생의 VO2max 추정식 개발)

  • Park, Dong-Ho;Song, Jung-Ran;Lee, Sang-Hyun;Kim, Chang-Sun
    • Exercise Science
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • The purpose of this study was to develop and validate regression models to estimate maximal oxygen uptake (VO2max) from the 20 m Progressive Shuttle Run Test (20 m PSRT) in Korean middle-school girls aged 13-15 years. The 20 m PSRT and VO2max were assessed in a sample of 194 participants. The sample was randomly split into validation (n=127) and test-retest reliability (n=99, 32 out of 127 participants also performed validity test) groups. 127 participants performed a graded exercise test (GXT, stationary gas analyser) and the 20 m PSRT (portable gas analyser) once to develop a VO2max prediction model and to analyze the validity of the modified 20 m PSRT protocol (starting at 7.5 km/h and increasing by 0.5 km/h every 1 min). 99 participants performed the 20 m PSRT twice for test-retest reliability purpose. Mean measured VO2max (39.2±5.1 ml/kg/min) from the potable gas analyzer was significantly increased from that measured during the GXT from stationary gas analyzer (37.7±5.7 ml/kg/min, p=.001) using the modified 20 m PSRT protocol. But it was a narrow range (1.5 ml/kg/min). The measured VO2max from the potable and stationary gas analyzers correlated at r=.88(p<.001). Test-retest of the 20 m PSRT yielded comparable results (Laps r=.88 & final speed r=.85). New regression equations were developed from present data to predict VO2max for middle-school girls: y=.231×Laps-.311×weight(in kg)+46.201 (r=.74, SEE=4.29 ml/kg/min). It is concluded that (a) the modified 20 m PSRT protocol is a valid and reliable test and (b) this equation developed in this study provides valid estimates of VO2max of Korean middle-school girl aged 13-15 years.

DEGREE CONDITIONS AND FRACTIONAL k-FACTORS OF GRAPHS

  • Zhou, Sizhong
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.2
    • /
    • pp.353-363
    • /
    • 2011
  • Let k $\geq$ 1 be an integer, and let G be a 2-connected graph of order n with n $\geq$ max{7, 4k+1}, and the minimum degree $\delta(G)$ $\geq$ k+1. In this paper, it is proved that G has a fractional k-factor excluding any given edge if G satisfies max{$d_G(x)$, $d_G(y)$} $\geq$ $\frac{n}{2}$ for each pair of nonadjacent vertices x, y of G. Furthermore, it is showed that the result in this paper is best possible in some sense.

Measurement of AC Hysteresis Loops under Variable Tensile Stress for Amorphous Wire (비정질 세선의 인장응력에 따른 교류자기이력 특성측정)

  • 조희정;양종만;손대락;김구영
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.61-64
    • /
    • 1993
  • We have constructed a hysteresis loop tracer in order to measure the magnetic properties of amorphous wires under variable tensile stress. It has a force range of 0 N to 20 N and a magnetizing frequency of 1 kHz to 20 kHz. Using the ac-hysteresis loop tracer, we can measure the magnetic properties(maximum magnetic induction $B_{max}$, residual magnetic induction $B_{r}$, coercive field strength $H_{c}$, etc.) of amorphous wires with precision of 1% under variable tensile stresses.

  • PDF

IMPROVEMENT AND GENERALIZATION OF A THEOREM OF T. J. RIVLIN

  • Pritika, Mahajan;Devi, Khangembam Babina;Reingachan, N.;Chanam, Barchand
    • Nonlinear Functional Analysis and Applications
    • /
    • v.27 no.3
    • /
    • pp.691-700
    • /
    • 2022
  • Let p(z) be a polynomial of degree n having no zero inside the unit circle. Then for 0 < r ≤ 1, the well-known inequality due to Rivlin [Amer. Math. Monthly., 67 (1960) 251-253] is $$\max\limits_{{\mid}z{\mid}=r}{\mid}p(z){\mid}{\geq}{\(\frac{r+1}{2}\)^n}\max\limits_{{\mid}z{\mid}=1}{\mid}p(z){\mid}$$. In this paper, we generalize as well as sharpen the above inequality. Also our results not only generalize, but also sharpen some known results proved recently.