• 제목/요약/키워드: max

Search Result 6,392, Processing Time 0.034 seconds

ON FUZZY INTEGRALS DEFINED BY MAX-MEASURES

  • KIM, HYUN MEE;JANG, LEE-CHAE
    • Honam Mathematical Journal
    • /
    • v.26 no.3
    • /
    • pp.355-364
    • /
    • 2004
  • In this paper, we consider fuzzy integrals defined by max-measures and discuss some properties of these fuzzy integrals of measurable functions.

  • PDF

Remote Sensing of NO2 vertical profiles in Beijing on the basis of MAX-DOAS measurements (지상 MAX-DOAS를 이용한 중국 베이징에서의 이산화질소 연직분포 산출 및 지상자료와 비교를 통한 검증연구)

  • Ryu, Jae-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.703-708
    • /
    • 2014
  • $NO_2$ vertical profiles were retrieved via ground based MAX-DOAS measurements for the summer period in 2006 in Beijing, one of the megacities in the Northeast Asia. Large portion of $NO_2$ load was observed at the 0-1 km layer. We found that $NO_2$ rapidly decreases up to the altitude of 3 km. In addition, the retrieved $NO_2$ mixing ratios within 0-1 km layer were compared with those observed at the surface by in-situ monitor. The correlation coefficient (R) between $NO_2$mixing ratios within 0-1 km layer and those at the surface was calculated to be 0.7. The major causes of such discrepancy are thought to be both differences in measured areas and rapid decrease in $NO_2$ mixing ratio with height.

Bioequivalence Assessment of Nabumetone Tablets in Healthy Korean Volunteers

  • Park, Moon-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.15 no.2
    • /
    • pp.118-122
    • /
    • 2007
  • This study was performed to evaluate the bioequivalency between the Osmetone$^{TM}$ Tablet (Myeongmoon Pharm. Co., Ltd.) as a test formulation and the Relafen$^{TM}$ Tablet (Handok Pharm. Co., Ltd.) as a reference formulation. Twenty-four healthy male volunteers were administered the formulations by the randomized Latin square crossover design, and the plasma samples were determined by a high performance liquid chromatography (HPLC) with Ultra-Violet (UV) detector. AUC$_t$, C$_{max}$ and T$_{max}$ were obtained from the time-plasma concentration curves, and log-transformed AUC$_t$ and C$_{max}$ and log-untransformed T$_{max}$ values for two formulations were compared by statistical tests and analysis of variation. AUC$_t$ was determined to be 897.8${\pm}$431.1 ug.hr/ml for the reference formulation and 902.3${\pm}$408.4 ug.hr/ml for the test formulation. The mean values of C$_{max}$ for the reference and test formulations were 24.2${\pm}$8.9 and 24.0${\pm}$9.5 ug/ml, respectively. The AUC$_t$ and C$_{max}$ ratios of the reference Relafen$^{TM}$ Tablet to the test Osmetone$^{TM}$ Tablet were +5.01% and -0.83%, respectively, showing that the mean differences were satisfied the acceptance criteria within 20%. The results from analysis of variance for logtransformed AUC$_t$ and C$_{max}$ indicated that sequence effects between groups were not exerted and 90% confidence limits of the mean differences for AUC$_t$ and C$_{max}$ were located in ranges from log 0.80 to log 1.25, satisfying the acceptance criteria of the KFDA bioequivalence. The Osmetone$^{TM}$ Tablet as the test formulation was considered to be bioequivalant to the Relafen$^{TM}$ Tablet used as its reference formulation, based on AUC$_t$ and C$_{max}$ values.

Contrast Sensitivity as a function of spatial frequency by using polarization (편광을 이용한 눈의 공간주파수-대비민감도 함수 측정기구 설계)

  • Kim, Young-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2000
  • It was to adjust the luminance of light by the rotation angle of the polarizes and analyzer. The luminance value Lmax, Lmin of Contrast Sensitivity could be obtained from the rotation angle ${\theta}_m$ of the average luminance($L_m$), the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the maximum and the minimum's amplitude. $$L_{max}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1+C_s^{-1})$$ $$L_{min}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1-C_s^{-1})$$ We obtained the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the polarizes and analyzer from the rotation angle ${\theta}_m$ of the average luminance($L_m$) and the Contrast Sensitivity($C_s$). $${\theta}_{max}=cos^{-1}[cos{\theta}_m{\cdot}(1+C_s^{-1})^{1/2}]$$ $${\theta}_{min}=cos^{-1}[cos{\theta}_m{\cdot}(1-C_s^{-1})^{1/2}]$$.

  • PDF

Design of Dual-Band Microstrip Antenna for Marine Telecommunication (해상 무선통신을 위한 이중대역 마이크로 스트립 안테나 설계)

  • Choi, Jo-Cheon;Lee, Gwang-Bok;Kim, Kab-Ki;Lee, Seong Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.12
    • /
    • pp.1314-1317
    • /
    • 2014
  • In this letter, we designed monopole microstrip antenna for WLAN / WiMAX system. The monopole antenna is designed by FR-4 substrate with size is $30mm{\times}40mm$. The proposed antenna is based on a planar monopole design which cover WLAN and WiMAX frequency bands. To obtainthe optimized parameters, we used the simulator, CST's Microwave Studio Program and found the parameters that greatly effect antenna characteristics. Using the obtained parameters, the antenna is designed. Thus the proposed antenna satisfied the -10 dB impedance bandwidth requirement while simultaneously covering the WLAN and WiMAX bands. And characteristics of gain and radiation patterns are obtained for WLAN/WiMAX frequency bands.

On the Feasibility of Dual Mode LTE-FDD/TDD and Dual Mode WiMAX-TDD/LTE-TDD (듀얼모드 LTE-FDD/TDD 및 듀얼모드 WiMAX-TDD/LTE-TDD에 대한 실현가능성 연구)

  • Cho, Bong-Youl;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.45-55
    • /
    • 2010
  • While Long Term Evolution-Frequency Division Duplexing (LTE-FDD) is regarded as one of the strong candidates for "4G" wireless broadband access in FDD field, LTE-Time Division Duplexing (TDD) is emerging as one possible migration path for WiMAX-TDD in some cases as well as the migration path for Time Division-Synchronous Code Division Multiple Access (TD-SCDMA). In this paper, we analyze the feasibility of dual mode with LTE-TDD in two combinations: dual mode LTE-FDD/TDD and dual mode Worldwide Interoperability for Microwave Access (WiMAX)-TDD/LTE-TDD. Thanks to the commonality in numerology, terminology, and frame structure between LTE-FDD and LTE-TDD, dual mode LTE-FDD/TDD looks feasible in a cost-effective manner. Thanks to the commonality in scheduling algorithm, control mechanism, and supported spectrum bands, it is shown that dual mode WiMAX-TDD/LTE-TDD looks feasible as well. It should be also noted that the commonality in numerology and frame structure is critical for building a chip while the commonality in algorithms and control mechanisms is critical to make it work.

Frame Synchronization for Mobile WiMAX Femtocells Using IEEE802.11 Based Wireless Backhaul (IEEE 802.11 기반의 무선 백홀을 사용하는 Mobile WiMAX 펨토셀을 위한 프레임 동기화 기법)

  • Choi, Ji-Hoon;Oh, Hyuk-Jun;Yun, Jae-Yeun;Ko, Hyun-Mo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8C
    • /
    • pp.667-679
    • /
    • 2010
  • The use of femtocells in buildings and homes has been widely studied as a means to enlarge the cell coverage and increase the network capacity of mobile communication systems. Femtocells for Mobile WiMAX (M-WiMAX) using time division duplexing (TDD) requires frame synchronization with neighboring base stations to avoid interference between uplink and downlink signals. In this paper, we propose a new frame synchronization method for femtocell using IEEE 802.11 based wireless backhaul, which transfers the time information of mobile network to femtocells via the beacon signal provided by IEEE 802.11. Also, in order to reduce timing error of the proposed method, we modify the collision avoidance scheme in the transmitter of IEEE 802.11 and apply a timing estimation technique designed in the sense of least squares to the receiver of IEEE 802.11. Through computer simulations using the proposed scheme, we evaluate the performance of frame synchronization for femtocells and show that the recovered timing information satisfies the timing specification defined by M-WiMAX standard.

Dependence of Halo Properties on Galactic Potentials

  • Kim, Youngkwang;Lee, Young Sun;Beers, Timothy C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.51.1-51.1
    • /
    • 2017
  • We present the dependence of halo properties on two different Galactic potentials: the $St{\ddot{a}}ckel$ potential and the Milky Way-like potential known as "Galpy". Making use of the Sloan Digital Sky Survey Data Release 12 (SDSS DR12), we find that the shape of the metallicity distribution and rotation velocity distribution abruptly changes at 15 kpc of $Z_{max}$ (the maximum distance of stellar orbit above or below the Galactic plane) and 32 kpc of $r_{max}$ (the maximum distance of an orbit from the Galactic center) in the $St{\ddot{a}}ckel$, which indicates that the transition from the inner to outer halo occurs at those distances. When adopting the $St{\ddot{a}}ckel$ potential, stars with $Z_{max}$ > 15 kpc show a retrograde motion of $V_{\phi}=-60km\;s^{-1}$, while stars with $r_{max}$ > 32 kpc show $V_{\phi}=-150km\;s^{-1}$. If we impose $V_{\phi}$ < $-150km\;s^{-1}$ to the stars with $Z_{max}$> 15 kpc or $r_{max}$> 32, we obtain the peak of the metallicity distribution at [Fe/H] = -1.9 and -1.7 respectively. However, there is the transition of the metallicity distribution at $Z_{max}=25kpc$, whereas there is no noticeable retrograde motion in the Galpy. The reason for this is that stars with high retrograde motion in the $St{\ddot{a}}ckel$ potential are unbound and stars with low rotation velocity reach to larger region of $Z_{max}$ and $r_{max}$ due to shallower potential in the Galpy. These results prove that as the adopted Galactic potential can affect the interpretation of the halo properties, it is required to have a more realistic Galactic potential for the thorough understanding of the dichotomy of the Galactic halo.

  • PDF

Bioequivalence Evaluation of Senafen Tablet and Airtal Tablet Containing Aceclofenac 100 mg (아세클로페낙(100mg) 제제인 세나펜 정과 에어할 정의 생물학적동등성 평가)

  • 박은우;송우헌;차영주;최영욱
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.423-428
    • /
    • 1998
  • Aceclofenac is an orally effective non-steroidal anti-inflammatory agent of the phenylacetic acid derivative. Bioequivalence study of two aceclofenac preparations, the test drug (Senafe $n_{R}$: Daewon Phar-maceutical Company) and the reference drug (Airta $l_{R}$: Daewoong Pharmaceutical Company), was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Sixteen healthy male volunteers, 24$\pm$4 years old and 63.9$\pm$6.9 kg of body weight in average, were divided randomly into two groups and administered the drug orally at the dose of 100 mg as aceclofenac in a 2$\times$2 crossover study. Plasma concentrations of aceclofenac were monitored by HPLC method for 12 hr after administration. AU $Co_{-12h}$ (area under the plasma concentration-time curve from initial to 12 hr) was calculated by the linear trapezoidal method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{msx}$) were compiled directly from the plasma drug concentration-time data. Student's t-test indicated no significant differences between the formulations in these parameters. Analysis of variance (ANOVA) revealed that there are no differences in AU $Co_{12h}$, $C_{max}$ and $T_{max}$ between the formulations. The apparent differences between the formulations were far less than 20% (e.g., 0.25, 0.01 and 7.32 for AU $Co_{-12h}$, $C_{max}$. and $T_{max}$, respectively). Minimum detectable differences (%) between the formulations at $\alpha$=0.05 and 1-$\beta$=0.8 were less than 20% (e.g., 14.65, 12.47 and 15.46 for AU $Co_{-l2h}$, $C_{max}$ and $T_{max}$, respectively). The 90% confidence intervals for these parameters were also within $\pm$ 20% (e.g.,-10.19~10.68, -8.87~8.89 and -3.69~ 18.33 for AU $Co_{-12h}$, $C_{msx}$ and $T_{max}$, respectively). These results satisfy the bioequivalence criteria of KFDA guidelines, indicating that two formulations of aceclofenac are bioequivalent.quivalent.ivalent.ent.t.ent.

  • PDF