• Title/Summary/Keyword: matrix spike

Search Result 15, Processing Time 0.023 seconds

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation

  • Park, Chang-J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1541-1544
    • /
    • 2002
  • The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

A study on determination of carbadox and olaquindox in swine tissues by matrix solid Phase disperse method" (MSPD 방법에 의한 돈육중 Carbadox와 Olaquindox 분석법 연구)

  • 황래홍;김영수;김기근
    • Korean Journal of Veterinary Service
    • /
    • v.19 no.2
    • /
    • pp.163-171
    • /
    • 1996
  • This study was carried out to determination of carbadox and olaquindox residues in swine tissues by MSPD(matrix solid phase disperse)method. The results obtained were as follows ; 1. Optimal wavelengths of UV for carbadox and olaquindox were 310 and 370nm, respectively 2. Ethyl acetate-Acetonitrile(8:2) was found to be adequate as extractant in this method. 3. The average overall recovery of carbadox at the 0.01, 0.05, and 1.0PPM spike levels was 89. 2% and that of olaquindox was 89.9%, and the detection limits were 0.5ng for carbadox and olaquindox.

  • PDF

Structure of the Male Reproductive System in the Freshwater Prawn Macrobrachium nipponense (징거미새우, Macrobrachium nipponense 수컷 생식기의 구조)

  • 김대현;한창희
    • Journal of Life Science
    • /
    • v.8 no.5
    • /
    • pp.582-588
    • /
    • 1998
  • The male reproductive system of Macrobrachium nipponense consists of a pair of lobulate testes enveloped within a mesenteric sheath extending the length of the carapace. The paired vasa deferentia originated from the mid-lateral region of each testis and extended to the genital pores at the base of the fifth walking legs. The vas deferens has four morphologically distinct regions, i.e., a short and slender proximal region, a long convoluted region, an elongate distal region and an ejaculatory duct that terminates at the genital pore. The sperm mass produced in the testes is surrounded by a basophilic matrix adjacent to the high columnar epithelium and an eosinophilic matrix adjacent to the simple columnar epithelium. The sperm cord is stored in the ejaculatory duct until it is ejaculated. Androgenic gland is found near the subterminal region of the ejaculatory duct between the muscles of the coxopodite of the last thoracic leg. The cell of the androgenic gland is about 6~8 $\mu$m in length, characterized by with extended chromatin in the large nucleus that stained weakly with hematoxylin and there is a large quantity of cytoplasm. The sperm of M. nipponense are typical of the palaemonid type, having a convex, cup shaped head and an elongated spike extending from the centre of the convex head. The spermatophore consisted of an eosinophilic matrix, a basophilic matrix and paired sperm masses which was surrounded by the basophilic matrix. It generally shows a bilaterally symmetrical structure.

  • PDF

Fuzzy System Representation of the Spline Interpolation for differentiable functions

  • Moon, Byung-Soo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.358-363
    • /
    • 1998
  • An algorithm for representing the cubic spline interpolation of differentiable functions by a fuzzy system is presented in this paper. The cubic B-spline functions which form a basis for the interpolation function are used as the fuzzy sets for input fuzzification. The ordinal number of the coefficient cKL in the list of the coefficient cij's as sorted in increasing order, is taken to be the output fuzzy set number in the (k, l) th entry of the fuzzy rule table. Spike functions are used for the output fuzzy sets, with cij's as support boundaries after they are sorted. An algorithm to compute the support boundaries explicitly without solving the matrix equation involved is included, along with a few properties of the fuzzy rule matrix for the designed fuzzy system.

  • PDF

Initial oxidation behavior in High temperature of low carbonsteel containing small amount Ni element. (미량 Ni 함유 저 합금강의 고온초기 산화거동)

  • 손근수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.179-184
    • /
    • 1999
  • When the steel containing Si is oxidated in hi temperature, Re2O3, Red scale is made on the metal side as the spike phase, and this scale invasion into matrix. Therefore, it affects the feature, after rolling. It is reported that the role of Si is FeO/Fe2SiO4 eutectic compound, but Si can not affect pure iron independently. There must be Ni, then the spike phase can exist. Prominence and depression made by Ni that is necessity at the process to work iron. Therefore, in this study after the change of the amount of Ni in pure iron and steel and oxidation, the structure of the oxide and the surface, and the distribution of the elements were considered. In conclusion, at 100$0^{\circ}C$, 110$0^{\circ}C$, 120$0^{\circ}C$ the curves of oxidation weight are all S curves. Especially, in the beginning of oxidation as the amount of Ni increase, the amount of oxidation also increase. Practical steel has less oxidation than pure steel added Ni. There is much FeO in Fe-Ni alloy, compare to practical steel which has much Fe3O4. Especially, we could know considerable Ni was concentrated on the metal side in Fe-Ni alloy, practical steel. and the surface of the scale.

  • PDF

Improvement of Validity and Efficiency for Detection of Cryptosporidium Ocysts and Giardia Cysts in Environmental Water Samples (환경수 중 크립토스포리디움 오시스트 및 지아디아 시스트 검출의 정확도 및 회수율 향상을 위한 연구)

  • 이목영;조은주;김도연;변승헌;이의광;오세종;안승구
    • Korean Journal of Microbiology
    • /
    • v.39 no.1
    • /
    • pp.27-35
    • /
    • 2003
  • No currently available methods to monitor pathogenic protozoa, Cryptosporidium and Giardia in environmental water come close to acceptable sensitivity, specificity and reproducibility, and so it has to be accompanied by thorough quality control and performance evaluation to credibly predict the distribution of them. We collected surface water samples from the Han River and spiked our prepared (oo)cysts, determined Matrix Spike recoveries using USEPA Method 1623 and considered what factors influence MS recovery and validity. As a result, average 46% of spiked oocysts and 60% of spike cysts were recovered, but repetitive sampling and statistical approach seemed to be necessary to determine the environmental pollution level of two protozoa as their variation coefficients was so much as 35oio and 26%. And MS recoveries with two acid dissociations during immunomagnetic separation were improved more 10% than that with one dissociations and the use of spiked suspension enumerated by flow cytometry instead of manual preparation enhanced the validity and reliability in spiking tests. Because fluorescence characteristics of (oo)cysts stained on well slides with FITC-labeled monoclonal antibodies and DAPI was not always same, well Elides from spiked field samples were helpful to evaluate the performance of staining. We found many (oo)cyst-like objects with typical fluorescence, not (co)cysts, from the Han River water samples, and then it was concluded that nuclei staining by DAPI (4',6-diamidino-2-phenylindole) and examination by Differential Interference Contrast Microscope should be critical for valid identification.

Genetic Diversity of Barley Cultivars as Revealed by SSR Masker

  • Kim, Hong-Sik;Park, Kwang-Geun;Baek, Seong-Bum;Suh, Sae-Jung;Nam, Jung-Hyun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.5
    • /
    • pp.379-383
    • /
    • 2002
  • Allelic diversity of 44 microsatellite marker loci originated from the coding regions of specific genes or the non-coding regions of barley genome was analyzed for 19 barley genotypes. Multi-allelic variation was observed at the most of marker loci except for HVM13, HVM15, HVM22, and HVM64. The number of different alleles ranged from 2 to 12 with a mean of 4.0 alleles per micro-satellite. Twenty-one alleles derived from 10 marker loci are specific for certain genotypes. The level of polymorphism (Polymorphic Information Content, PIC) based on the band pattern frequencies among genotypes was relatively high at the several loci such as HVM3, HVM5, HVM14, HVM36, HVM62 and HVM67. In the cluster analysis using genetic similarity matrix calculated from microsatellite-derived DNA profiles, two major groups were classified and the spike-row type was a major factor for clustering. Correlation between genetic similarity matrices based on microsatellite markers and pedigree data was highly significant ($r=0.57^{**}$), but these two parameters were moderately associated each other. On the other hand, RAPD-based genetic similarity matrix was more highly associated with microsatellite-based genetic similarity ($r=0.63^{**}$) than coefficient of parentage.

Hourglass Control in Rigid-Plastic Finite Element Analysis (강소성 유한요소해석에서 Hourglass Control)

  • Gang, Jeong-Jin;O, Su-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1290-1300
    • /
    • 1996
  • The finite element method, based on rigid-plastic formulation, is widely used to simulate metal forming processes. In order to improve the computational efficiency of the rigid-plastic FEM, one-point integration is used to evaluate the stiffness matrix with four-node rectangular elements and eight-node brick elements. In order to control the hourglass modes, hourglass strain rate components were introduced and included in the effective strain rate definition, Numerical tests have shown that the proposed one-point integration scheme reduces the stiffness matrix evaluation time without deteriorating the convergence behavior of Newton-Raphson method. Simulations of a ring compression, a plane-strain closed-die forging and the three-dimensional spike forging processes were carried out by using the proposed integration method. The simulation results are compared to those obtained by applying the conventional integraiton method in terms of the solution accuracy and computational efficiency.

A comparison study of 76Se, 77Se and 78Se isotope spikes in isotope dilution method for Se (셀레늄의 동위원소 희석분석법에서 첨가 스파이크 동위원소 76Se, 77Se 및 78Se들의 비교분석)

  • Kim, Leewon;Lee, Seoyoung;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.170-178
    • /
    • 2016
  • Accuracy and precision of ID methods for different spike isotopes of 76Se, 77Se, and 78Se were compared for the analysis of Selenium using quadrupole ICP/MS equipped with Octopole reaction cell. From the analysis of Se inorganic standard solution, all of three spikes showed less than 1 % error and 1 % RSD for both short-term (a day) and long-term (several months) periods. They showed similar results with each other and 78Se showed was a bit better than 76Se and 77Se. However, different spikes showed different results when NIST SRM 1568a and SRM 2967 were analyzed because of the several interferences on the m/z measured and calculated. Interferences due to the generation of SeH from ORC was considered as well as As and Br in matrix. The results showed similar accuracy and precisions against SRM 1568a, which has a simple background matrix, for all three spikes and the recovery rate was about 80% with steadiness. The %RSD was a bit higher than inorganic standard (1.8 %, 8.6 %, and 6.3 % for 78Se, 76Se and 77Se, respectively) but low enough to conclude that this experiment is reliable. However, mussel tissue has a complex matrix showed inaccurate results in case of 78Se isotope spike (over 100 % RSD). 76Se and 77Se showd relatively good results of around 98.6 % and 104.2 % recovery rate. The errors were less than 5 % but the precision was a bit higher value of 15 % RSD. This clearly shows that Br interferences are so large that a simple mathematical calibration is not enough for a complex-matrixed sample. In conclusion, all three spikes show similar results when matrix is simple. However, 78Se should be avoided when large amount of Br exists in matrix. Either 76Se or 77Se would provide accurate results.

Evaluation of LC/MS and LC/UVD(EPA-631) Methods in Determination of Benomyl Concentration in Water Samples (LC/MS법 및 LC/UVD(EPA-631)를 이용한 수계 중 Benomyl의 분석법 평가)

  • Kim, Kee D.;Choi, Won Gyu;Seo, Yong Chan;Park, Byung Hwang;Choi, Hye Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.1
    • /
    • pp.40-44
    • /
    • 2001
  • Benomyl, one of the known endocrine disrupting chemicals, was analyzed to understand the its fate in water. Benomyl analysis process in water sample include the following sequential steps. Hydrolysis of benomyl into carbendazim, solvent extraction, concentration, and the concentration of final carbendazim solution was determined by LC/MS (TOF). Recoveries of the spiked samples were good with the range of 80.6 to 118.6% and the MDL was 1,600 times lower than that of LC/UVD method. The use of LC/MS (TOF) successfully eliminated the positive error incurred by interferencing materials in the matrix.

  • PDF