• 제목/요약/키워드: materials flow

검색결과 3,926건 처리시간 0.027초

다이캐스트 주물의 금형공동내에서 탕류에 관한 수모델적 연구 (A Water Model Study on Molten Metal Flow in Die Cavity of Die Casting)

  • 김명제;최희호;조남돈
    • 한국주조공학회지
    • /
    • 제14권6호
    • /
    • pp.576-589
    • /
    • 1994
  • Water modeling experiments and computer simulation for the predictions of defects of die castings are very important to produce high quality castings with less cost. The relation between the variable air vent system and the characteristics of the fluid flow in the die cavity is studied by using water modeling tests, which give ideas on reasonable designing of die cavity, vent arrangement and gating system. In order to test the water modeling, injection is done by using water containing NaCl. Flow behaviors in cavities are visualized by high speed camera and video tape recorder, and local filling time is measured with electrode sensors. Special attention is paid to the configuration of die cavity. Simulated results by computer are examined and compared with the results of water modeling experiments. There are close correlations between the simulated results and water modeling ones.

  • PDF

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

비정상 열 하중을 받는 이질재료의 열량 집중 계수 해석 (Thermal flow intensity factor for non-homogeneous material subjected to unsteady thermal load)

  • 김귀섭
    • 한국항공운항학회지
    • /
    • 제16권4호
    • /
    • pp.26-34
    • /
    • 2008
  • This article provides a comprehensive treatment of cracks in non-homogeneous structural materials such as functionally graded materials (FGMs). It is assumed that the material properties depend only on the coordinate perpendicular to the crack surfaces and vary continuously along the crack faces. By using laminated composite plate model to simulate the material non-homogeneity, we present an algorithm for solving the system based on Laplace transform and Fourier transform techniques. Unlike earlier studies that considered certain assumed property distributions and a single crack problem, the current investigation studies multiple crack problem in the FGMs with arbitrarily varying material properties. As a numerical illustration, transient thermal flow intensity factors for a metal-ceramic joint specimen with a functionally graded interlayer subjected to sudden heating on its boundary are presented. The results obtained demonstrate that the present model is an efficient tool in the fracture analysis of non-homogeneous material with properties varying in the thickness direction.

  • PDF

The effect of the MgO process on the properties of AC-PDPs

  • Kim, Young-Sung;Park, Min-Soo;Ryu, Byung-Gil
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1376-1379
    • /
    • 2007
  • The effects of the MgO fabrication process on the properties of AC-PDPs were examined. MgO films were deposited by e-beam evaporation with various substrate temperatures and oxygen flow rates. MgO films were analyzed by XRD, CL and ellipsometer. Panel properties such as luminance, efficiency, discharge voltage and discharge delay time were measured with test panels. MgO films with higher temperature, smaller oxygen flow rate showed shorter discharge delay time. Also they showed smaller XRD peak intensity. These results revealed that the discharge delay time was strongly influenced by temperature and oxygen flow rate of the MgO fabrication process.

  • PDF

Transverse permeability measurement of a circular braided preform in liquid composite molding

  • Chae, Hee-Sook;Song, Young-Seok;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • 제19권1호
    • /
    • pp.17-25
    • /
    • 2007
  • In liquid composite molding (LCM), composites are produced by impregnation of a dry preform with liquid resin. The resin flow through the preform is usually described by Darcy's law and the permeability tensor must be obtained for filling analysis. While the resin flow in the thickness direction can be neglected for thin parts, the resin flow in the transverse direction is important for thicker parts. However, the transverse permeability of the preform has not been investigated frequently. In this study, the transverse permeability was measured experimentally for five different fiber preforms. In order to verify the experimental results, the measured transverse permeability was compared with numerical results. Five different fiber mats were used in this study: glass fiber woven fabric, aramid fiber woven fabric, glass fiber random mat, glass fiber braided preform, and glass/aramid hybrid braided preform. The anisotropic braided preforms were manufactured by using a three dimensional braiding machine. The pressure was measured at the inlet and outlet positions with pressure transducers.

반용융상태에서 재료의 변형거동에 관한 유한요소해석 (Finite Element Analysis of r Deformation Behavior of Materials at Semi-Solid State)

  • 윤종훈;김낙수;김헌영;김중재;임용택
    • 소성∙가공
    • /
    • 제6권4호
    • /
    • pp.319-328
    • /
    • 1997
  • A flow stress involving strain, solid fraction, and breakage ratio, and solid fraction updating algorithm were proposed to depict the deformation behavior of materials at the semi-solid state. In case of isothermally simple upsetting of Sn-15%Pb alloy at the semi-solid state, by comparing the results of finite element analysis with the existing experimental results, the reliability of both the developed flow stress and updating algorithm were investigated. It was found that the verified program can effectively be used in the rigid-viscoplastic finite element analysis of the semi-solid forging processes.

  • PDF

분말컨넥팅로드 단조의 유한 요소 해석 (Finite Element Analysis of P/M Connecting Rod Forging)

  • 박종진
    • 소성∙가공
    • /
    • 제1권1호
    • /
    • pp.33-41
    • /
    • 1992
  • Sintered P/M connecting rod is forged to increase density and to satisfy dimensional specifications. Flow of the materials is different form that of wrought materials due to pores in the preform. The Mises yield function was modified to. include the first invariant of stress tensor, and the associated flow rule was derived by applying the normality rule to the yield function. Axisymmetric and plane-strain finite element analyes were carried out for the ring and beam portions of the connecting rod, respectively. The flow of the preform and density change of the analysis are presented in this paper. A load-stroke curve was also presented by superimposing analysis results for the ring and beam portions.

  • PDF

Experimental Determination of Velocity Flow Fields in a Cold Model for Czochralski Crystal Growth System Using an Incorporated Magnet Probe

  • Lee, Snag-Ho;Kim, Min-Cheol;Yi, Kyung-Woo
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1998년도 PROCEEDINGS OF THE 15TH KACG TECHNICAL MEETING-PACIFIC RIM 3 SATELLITE SYMPOSIUM SESSION 4, HOTEL HYUNDAI, KYONGJU, SEPTEMBER 20-23, 1998
    • /
    • pp.21-25
    • /
    • 1998
  • An experimental investigation on flow pattern was carried out in molten Woods metal using an incorporated magnet probe to determine the velocity field in a Woods metal model of Czochralski crystal growth system. The local velocities in Woods metal were obtained 3-dimensionally at numerous positions of large crucible by measuring the voltage induced in the melt. Since there have not been a lot of the model experiments on the velocity distributions in the large size of melt with low Prandtl number for Czochralski crystal growth system, the present paper aims to give useful guidelines for e analysis of fluid flow in Czochralski growth system.

  • PDF

Numerical Analysis on the Flow Pattern in the Melt of Cold Model for the Czochralski system

  • Kim, Min-Cheol;Lee, Sang-Ho;Yi, Kyung-Woo
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1998년도 PROCEEDINGS OF THE 15TH KACG TECHNICAL MEETING-PACIFIC RIM 3 SATELLITE SYMPOSIUM SESSION 4, HOTEL HYUNDAI, KYONGJU, SEPTEMBER 20-23, 1998
    • /
    • pp.113-116
    • /
    • 1998
  • A numerical study was performed on the fluid flow in the melt of the cold model for Czochralski growth system. The fluid flow in the melt of Woods metal with crucible diameter of 20cm was calculated using a three dimensional finite difference method. Since the crucible size is large, fully turbulent model as well as laminar model was used in the calculation. The effects of crucible rotation rate, crystal rotation rate and wall temperature difference on the velocity and temperature distribution were also investigated. For the purpose of verifying the results of calculation, a cold model experiment using Woods metal was also conducted and the velocity distribution in the melt of the model was measured.

  • PDF

공압시스템 제습용 중공사막 모듈의 하우징 형태에 따른 제습효율 특성 연구 (A Study on Dehumidification Characteristics of Housing with Shape for Pneumatic System)

  • 정은아;이기윤;윤소남
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.66-71
    • /
    • 2019
  • In this study, flow analysis and dehumidification experiments were performed on hollow fiber membrane module to confirm the dehumidification characteristics for its different configurations. The CFD for the three different models was conducted using $30^{\circ}C$ temperature and 30%RH inlet humidity for quantitative analysis. Each model has different shape parameters i.e. the number of baffles. Comparison between flow analysis results and dehumidification experiment results revealed a percentage error of about 5%. The difference in relative humidity between the inlet and outlet for each model was calculated using flow analysis data. It was established that the difference in relative humidity of the inlet and outlet for the refined model with three baffles was highest among the three modeled modules of hollow fiber membrane module, i.e. around 9%.