• Title/Summary/Keyword: material homogeneity

Search Result 160, Processing Time 0.027 seconds

Effect of the Structured Education for Knowledge of Hepatitis B Type and Self Care Behavior in Chronic Hepatitis B Patients (구조화된 환자교육이 만성 B형 간염환자의 B형 간염에 관한 지식과 자가간호 수행에 미치는 효과)

  • Eum Sun-Ja
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.65-79
    • /
    • 1998
  • The purpose of this study was to identify the effect of structured patient education on knowledge of Hepatitis B type and behavior about self care in chronic hepatitis B patients, and to fine the strategy to promote their self care behavior. The research design was quasi-experiment research. The study method had been done by investigating the experimental group and control group through the questionnaire on 50 patients who had been out patient medicine department in U university hospital in Ulsan from september 1st 1997 to the end of October, 1997. The analysis of the collected material had been done for the homogeneity test in which general characterics of experimental group and control group had been tested by $x^2-test$ and the homogeneity test of the knowledge of hepatitis B type and self care behavior before by t-test. To test the hypothesis the t-test had been given for the difference of the knowledge of hepatitis B type and self care behavior between the two groups and the correlation between knowledge of hepatitis B type and self care behavior performance had been tested by Pearson's correlation coefficient. The results as follows : 1. The 1st hypothesis 'The experimental group which received the structured education should be higher in the knowledge of hepatitis B type than the control group' was supported(t=-6.25, P=.000). 2. The 2nd hypothesis 'The experimental group which received the structured education whould be higher in the self care behavior performance than the control group' was supported(t=-5.15, P=.000). 3. The 3rd hypothesis 'The higher the knowledge of hepatitis B type in the patient the higher the self care behavior performance degree' was supported(r=.492, P=.001). In conclusion, the patients who received the structured education showed the increase in the degree of knowledge of hepatitis B type and self care behavior performance. so the structured education had been judged the nursing intervention had been prerequisite in increasing knowledge of hepatitis B type and self care behavior performance of the chronic hepatitis B patients.

  • PDF

An Investigation on the Nonlinear Shear Behavior of FRP Composites Considering Temperature Variation and Fabricating Parameters (FRP 복합재료의 온도변화 및 제작인자별 비선형 전단거동 조사)

  • Jung, Woo-Young;Hwang, Jin-Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.833-841
    • /
    • 2013
  • In the case of composite material, a variety of characteristics were expressed depending on the materials that were composed of. In this study, the materials showing non-linear shear behavior were investigated among FRP composite. Each specimen was designed and analyzed according to ASTM D4255 method: regulations on the 2-rail. The dependent variables included in this experiment were a variety of fiber, fiber volume ratio, fiber array direction, temperature, material homogeneity. For determination of characteristics based on the fiber array, fiber array direction of 0, 30, 45, and 60 degrees were selected for test specimen. Temperature of 25, 40, 60, and $80^{\circ}C$ were considered for investigation of FRP materials'shear behavior based on the external temperature. Nonlinear shear behavior was observed throughout the FRP composite material in this study. Also, using vinyl ester resins, high fiber volume ratio, and fiber array direction of 45 degree appeared to show the most prominent nonlinear shear behavior. As for the findings related to the temperature change, non-linear behavior was decreased as the external temperature increased. For factory manufactured product, non-linear behavior was relatively at parity in comparison to the behavior found in the hand lay-up FRP composite specimen.

Evaluation of field applicability for grouting method using self-healing grout material (자기치유 물질을 이용한 그라우팅공법의 현장적용성 평가)

  • Choi, Yong-Sung;Kim, Byoung-Il;Yoo, Wan-Kyu;Lee, Jae-Dug;Choi, Yong-Ki
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.485-500
    • /
    • 2020
  • Due to various advantages such as small facilities, ease of construction and so on, the grouting technology which is widely used in construction field has developed remarkably compared with the past. However, the efforts to improve the homogeneity of quality, long-term durability and environmental problems have been continued. In recent years, new grouting method has been developed in order to solve problems such as low strength, durability and leaching phenomenon of liquid glass (sodium silicate) grouting material in Korea. A newly developed method integrates the injection material with the ground by the self-healing material of crystallization growth type. For this reason, it is known that improvement of the durability and water quality of the ground, prevention of leaching, and environment friendliness can be expected. The present study applied a newly developed method to test sites and verified its effect such as injection range, improvement effect, waterproofing performance and so on. Standard penetration test, field permeability test, borehole shear test, pressuremeter test and pH test were conducted, and the results were compared between before and after developed method application. As results of tests, the field applicability and improvement effect of developed method were proved to be excellent.

Low temperature plasma deposition of microcrystalline silicon thin films for active matrix displays: opportunities and challenges

  • Cabarrocas, Pere Roca I;Abramov, Alexey;Pham, Nans;Djeridane, Yassine;Moustapha, Oumkelthoum;Bonnassieux, Yvan;Girotra, Kunal;Chen, Hong;Park, Seung-Kyu;Park, Kyong-Tae;Huh, Jong-Moo;Choi, Joon-Hoo;Kim, Chi-Woo;Lee, Jin-Seok;Souk, Jun-H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.107-108
    • /
    • 2008
  • The spectacular development of AMLCDs, been made possible by a-Si:H technology, still faces two major drawbacks due to the intrinsic structure of a-Si:H, namely a low mobility and most important a shift of the transfer characteristics of the TFTs when submitted to bias stress. This has lead to strong research in the crystallization of a-Si:H films by laser and furnace annealing to produce polycrystalline silicon TFTs. While these devices show improved mobility and stability, they suffer from uniformity over large areas and increased cost. In the last decade we have focused on microcrystalline silicon (${\mu}c$-Si:H) for bottom gate TFTs, which can hopefully meet all the requirements for mass production of large area AMOLED displays [1,2]. In this presentation we will focus on the transfer of a deposition process based on the use of $SiF_4$-Ar-$H_2$ mixtures from a small area research laboratory reactor into an industrial gen 1 AKT reactor. We will first discuss on the optimization of the process conditions leading to fully crystallized films without any amorphous incubation layer, suitable for bottom gate TFTS, as well as on the use of plasma diagnostics to increase the deposition rate up to 0.5 nm/s [3]. The use of silicon nanocrystals appears as an elegant way to circumvent the opposite requirements of a high deposition rate and a fully crystallized interface [4]. The optimized process conditions are transferred to large area substrates in an industrial environment, on which some process adjustment was required to reproduce the material properties achieved in the laboratory scale reactor. For optimized process conditions, the homogeneity of the optical and electronic properties of the ${\mu}c$-Si:H films deposited on $300{\times}400\;mm$ substrates was checked by a set of complementary techniques. Spectroscopic ellipsometry, Raman spectroscopy, dark conductivity, time resolved microwave conductivity and hydrogen evolution measurements allowed demonstrating an excellent homogeneity in the structure and transport properties of the films. On the basis of these results, optimized process conditions were applied to TFTs, for which both bottom gate and top gate structures were studied aiming to achieve characteristics suitable for driving AMOLED displays. Results on the homogeneity of the TFT characteristics over the large area substrates and stability will be presented, as well as their application as a backplane for an AMOLED display.

  • PDF

Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking (Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가)

  • Kim, Tae Won;Yoo, Soon Mi;Jeon, Soo Dong;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.73-81
    • /
    • 2018
  • Purpose : The aims of this study were to compare and assess the effectiveness of Volumetric Modulated Arc Therapy(VMAT) using jaw tracking(JT) and fixed jaw(FJ) in radiation therapy of multiple brain metastasis. Methode and material : Among the patients with Multiple Brain Metastasis treated with jaw tracking, 10 patients with more than 6 tumors and with the size of radiation field $14{\times}14cm^2$ or more were included. Each Treatment plans with jaw tracking(JT) and fixed jaw(FJ) was established with Eclipse (Ver. 13.6 Varian, USA). Gamma Index (3 mm, 3 % confidence interval - 95 %) and maximum dose difference were measured with an electronic portal imaging device(EPID). The $D_{max}$ and $D_{mean}$ of Organ At Risk(OAR) were assessed and compared, and the Conformity Index(CI) and Homogeneity Index(HI) were evaluated. Result : Evaluating jaw tracking(JT) and fixed jaw(FJ) outcomes, in all cases, Gamma Index met the permissible standard of 3 mm, 3 % confidence intervals of 95 %. The maximum dose difference value from the areas with leaf end transmission was measured at a maximum of 98.4 % and an average of 43.6 % in clockwise(CW), and 67.9 % and 41.0 % for each in Counter-Clockwise(CCW). With jaw tracking, the maximum value of $D_{max}$ for each normal organ in OAR decreased in 15.36 %~74.59 % with the average value decreasing in 2.84 %~39.80 %. The maximum value of $D_{mean}$ in OAR decreased in 27.90 %~65.23 %, with the average value decreasing in 7.70 %~41.71 %. No change has been found in Conformity Index and Homogeneity Index values. Conclusion : When Jaw tracking is used in treating patients with multiple brain metastasis with VMAT, the unnecessary exposure due to leakage and transmission of radiation in unspecified areas was reduced, without affecting the dose distribution of the planning target volume(PTV), and the availability of radiation therapy with lower doses in normal organs is expected.

  • PDF

Material Life Cycle Assessment of Graphene 2wt% Added to Li1.6Ni0.35Mn0.65O2 Half-Cell (그래핀 2wt%를 첨가한 Li1.6Ni0.35Mn0.65O2 Half-Cell의 물질 전 과정 평가)

  • CHO, KYOUNG-WON;LEE, YOUNG-HWAN;HAN, JEONG-HEUM;YU, JAE-SEON;HONG, TAE-WHAN
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.132-137
    • /
    • 2020
  • Lithium secondary batteries have become an important power source for portable electronic devices such as cellular phones, laptop computers. Presently, commercialized lithium-ion batteries use a LiCoO2 cathode. However, due to the high cost and environmental problems resulting from cobalt, an intensive search for new electrode materials is being actively conducted. Recently, solid solution LiMn1-xNixO2 have become attractive because of high capacity and enhanced safety at high voltages over 4.5 V. The Li1.6Ni0.35Mn0.65O2 compounds were conventionally prepared by a sol-gel method, which can produce the layered Li-Ni-Mn-O compounds with a high homogeneity. And by adding a graphene 2wt% the first charge-discharge voltage profiles was increased over Li1.6Ni0.35Mn0.65O2 compound. Also, the variation s of the discharge capacities with cycling showed a higher capacity retention rater. In this study, material lifecycle evaluation was performed to analyze the environmental impact characteristics of Li1.6Ni0.35Mn0.65O2 & graphene 2wt% half-cell manufacturing process. The software of material life cycle assessment was Gabi. Through this, environmental impact assessment was performed for each process. The environmental loads induced by Li1.6Ni0.35Mn0.65O2 & graphene 2wt% synthesis process were quantified and analyzed, and the results showed that the amount of power had the greatest impact on the environment.

A study on the Change of Uniaxial Compressive Strength and Young's Modulus According to the Specimen Size of Intact Material (무결함 재료의 크기에 따른 강도와 탄성계수의 변화에 관한 연구)

  • Lee, Seung-Woo;Song, Jae-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.3
    • /
    • pp.205-217
    • /
    • 2006
  • Rock and discontinuities are main factors consisting of a rock mass and the physical properties of each factor have direct effects on the mechanical stability of artificial structures in the rock mass. Because physical properties of the rock and discontinuities change a lot according to the size of test materials, a close attention is needed when the physical properties, obtained from laboratory tests, are used for the design of field structures. In this study, change of physical properties of intact materials due to the change of their size are studied. Six kinds of artificial materials including crystal, instead of an intact rock, are adopted for the study to guarantee the homogeneity of specimen materials even with relatively large size. Uniaxial strength and Young's modulus of each artificial material are checked out for a size effect and compared with the predicted values by Buckingham's theorem - dimensional analysis. A numerical analysis using PFC (Particle Flow Code) is also applied and primary factors influencing on the size effect are investigated.

Improving Reproducibility of Coercivity of HDDR-treated Nd-Fe-B-type Material by Controlling Hydrogen Decrepitation (수소파쇄 제어를 통한 HDDR 처리한 Nd-Fe-B계 재료의 보자력 재현성 향상)

  • Kim, Kyung Min;Kim, Ja Young;Kwon, Hae-Woong;Lee, Jeong Gu;Yu, Ji Hun
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.111-116
    • /
    • 2015
  • Practical difficulty in the HDDR (hydrogenation - disproportionation - desorption - recombination) processing of Nd-Fe-B-type alloy is a poor reproducibility of coercivity of the HDDR-treated material. In an attempt to improve the reproducibility of coercivity of the HDDR-treated $Nd_{12.5}Fe_{80.6}B_{6.4}Ga_{0.3}Nb_{0.2}$ alloy, the hydrogen decrepitation was carefully controlled so as to induce more extensive micro-cracks in the particle. Prior to the hydrogenation and disproportionation reaction of HDDR processing, an additional hydrogen degassing was carried out at an elevated temperature of $600^{\circ}C$ under vacuum for the previously hydrogen decrepitated particle. During the additional hydrogen degassing the lattice of hydrogen absorbed $Nd_2Fe_{14}B$ phase was further shrunken, hence more microcracks were introduced in the particle due to its brittle nature. Particles with more micro-cracks had more homogeneous hydrogen absorption and desorption reaction during the HDDR-treatment. The improved reproducibility of coercivity of the HDDR-treated material was attributed to the improved homogeneity of the HDDR reactions due to the presence of more micro-cracks.

A comparison of nursing effects after the improvement of nasogastric tube feeding method (비위관 영양방법 개선에 따른 간호효과 비교)

  • Choi, Ja-Yun;Jang, Keum-Seong;Hwang, Seon-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.4
    • /
    • pp.645-654
    • /
    • 2002
  • Purposes : This study was conducted to examine nursing effects after using a new method of nasogastric tube feeding with recycled PETE bottle making use of gravity, and to compare with those of bolus method using syringe and pressure. Methods : The data collected from patients with nasogastric tube feeding more than a week at an internal medicine unit of C university hospital located in G-city from January 1st, 1998 through June 30th, 2000. For this nonequivalent control group posttest non-synchronized design, 28 patients were assigned to an experimental group and 35 patients to a control group. The homogeneity of two groups and the dependent variables were tested with use of $x^2-test$ and t-test. Results : The duration of hemostatic use was significantly shorter in the experimental group than control group(t=2.63, p=0.02). Also, the patients with PETE bottle feeding had a lower cost of material(t=3.51, p=0.01) and a lower rate of the time of direct nursing care(t=2.44, p=0.04) than those of control group. But, there was no significant difference between two groups in the length of hospital stay. Conclusion : This results indicates that nasogastric tube feeding with PETE bottle is superior to nasogastric tube feeding with syringe. This findings gave us an evidence to enhance nursing effectiveness in clinical setting.

  • PDF

The effect of nano-sized starting materials and excess amount of Bi on the dielectric/piezoelectric properties of 0.94[(BixNa0.5)TiO3]-0.06[BaTiO3] lead free piezoelectric ceramics

  • Khansur, Neamul Hayet;Ur, Soon-Chul;Yoon, Man-Soon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.31.1-31.1
    • /
    • 2009
  • In an approach to acclimate ourselves torecent ecological consciousness trend, a lead-free piezoelectric material, bismuth sodium titanate (abbreviated as BNT) based bismuth sodium barium titanate (abbreviated as BNT-BT), was considered as an environment-friendly alternative for a lead based piezoelectric system. Ceramic specimens of0.94[(BixNa0.5)TiO3]-0.06[BaTiO3] (x = 0.500~0.515) compositions were prepared by a modified mixed oxide method. To increase the chemical homogeneity andre action activity, high energy mechanical milling machine and pre-milled nanosized powder has been used. In this method (BixNa0.5)TiO3 (x=0.500~0.515) andBaTiO3 were prepared separately from pre-milled constituent materials at low calcination temperature and then separately prepared BNTX (X=1, 2, 3 and 4) and BT were mixed by high energy mechanical milling machine. Without further calcination step the mixed powders were pressed into disk shape and sintered at $1110^{\circ}C$. Microstructures, phase structures and electrical properties of the ceramic specimens were systematically investigated. Highly dense ceramic specimens with homogenous grains were prepared in spite of relatively low sintering temperature. Phase structures were not significantly influenced by the excess amount Bi. Large variation on the piezoelectric and dielectric properties was detected at relative high excess Bi amounts. When $x{\leq}0.505$, the specimens exhibit insignificant variation in piezoelectric and dielectric constant though depolarization temperature is found to be decreased. Considerable amount of decrease in piezoelectric and dielectric properties are observed with higher excess of Bi amounts ($x{\geq}0.505$). This research indicates the advantages of high energy mechanical milling and importance of proper maintenance of Bi stoichiometry.

  • PDF