• Title/Summary/Keyword: material artifact

Search Result 92, Processing Time 0.022 seconds

The Study about the Positioning Block Artifact in Digital Radiography Environment (Digital Radiography 환경에서 Positioning Block Artifact에 관한 연구)

  • Kim, Byung-Ki;Choi, Jun-Gu;Lee, Jun;Lee, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • Purpose : In sponge quality of the material in digital radiography environment coating because do position blocks two that do not become coating done positioning blocks two that do not become coating done positioning block and sponge quality of the material to testing bench image artifact's difference compare. Method of study : In digital radiography environment positioning block of different two products same sunshine or effect that image and positioning block artifact gents in image analyze. the target used positioning block 2 when examine hand, rib and examination condition did each differently according to used positioning block. reflex compared picture that do image and verify that examine first time. Result : 1. In sponge quality of the material coating in done product artifact appear. Did not appear in product that do not become coating. 2. Can know coating's existence, that artifact according to radish happens. 3. Quality of the material coating's existence, there was difference of slippage according to radish Conclusion : Quality of the material coating phenomenon that done positioning block thus, it may have to be considered that use after estimate degree that get in image.

  • PDF

The study on stability of restoration material of organic artifact (유기질 문화재 복원재료의 재질안정성에 대한 연구)

  • Jeong, Seon-Young;Jeong, So-Young;Jeong, Seon-Hwa;Seo, Jin-Ho
    • 보존과학연구
    • /
    • s.29
    • /
    • pp.5-18
    • /
    • 2008
  • Hanji among paper, which is material for support of the organic artifact such as painting and Thangkas, is given as much importance as the original material in the conservation treatment of artifacts. This lining paper can go through physical and chemical deterioration due to its organic nature, and inflict serious damage to the original materials of the artifact. There is a lot of difficulty in keeping continuous production of the paper mulberry fiber based on lining paper due to a short supply of raw material and discontinuation of traditional method. Also restoration and conservation treatment is done by relying only on the knowledge and skill of few experts without any recognized manual based on scientific analysis. In this study, we evaluated the stability of lining paper which is used to support organic artifact. As the result of experiments, this lining paper was made from mulberry tree in Korea and produced by means of oebal method, but was not treated by starch in its surface.

  • PDF

A Study on the Ball-Bar Artifact for the Volumetric Error Calibration of Machine Tools (Machine Tools 공간오차 분석을 위한 Bal1-bar Artifact 연구)

  • Lee, Eung-Suk;Koo, Sang-Seo;Park, Dal-Gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.986-991
    • /
    • 2004
  • For volumetric error measurement and calibration for machine tools, manufacturing machine or coordinate measuring machine (CMM), are studied using a Ball-bar artifact. A design of the Ball-bar is suggested manufactured by Invar, which is a low thermal expansion material, and precision steel balls. The uncertainty for the artifact method is discussed. A method of the Ball-bar artifact for obtaining 3-D position errors in CMM is proposed. The method of error vector measurement is shown using the Ball-bar artifact. Finally, the volumetric error is calculated from the error vectors and it can be used for Pitch error compensation in conventional NC machine and 3-D position Error map for calibration of NC machine tools.

The Study of Decrease Artifact when Scanning Head and Neck PET/CT(Decrease Radiation Dose of Patient) (두경부 PET/CT검사 시 인공음영 감소에 관한 연구 (환자 피폭선량 경감))

  • Kim, Ki-Jin;Kim, Gha-Jung;Yoo, Se-Jong;Kim, Jeong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.153-158
    • /
    • 2016
  • Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.

Analysis of the artifact reduction rate for the types of medical metals in CT with MAR algorithm (CT의 MAR알고리즘 적용 시 의료용 금속 물질별 인공물 감소율 분석)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.655-662
    • /
    • 2016
  • We investigated on the usefulness of MAR algorithm by making a comparison of the CT value between before and after applying the MAR algorithm in dual energy CT, using the various kinds of medical metals, causing the artifact to lead to the low image quality. As a result, the artifact was reduced in most cases (P<0.05); in particular, the artifact was highly reduced (P<0.05) using high density material, like alloy-stainless (reduced by 78.1%) and platinum, for example GDC coil (reduced by 76.1%). The effect of decreasing the Black hole artifact was outstanding in both the alloy-stainless and alloy-titanium (P<0.05). However, in case of GDC coil-a type platinum, white streak artifact was reduced effectively (P<0.05). Therefore, in case of patients who have medical metals inserted, we think that high-quality image information can be provided by decreasing the artifact caused by high density material through MAR algorithm in dual energy CT.

Distortion of Magnetic Resonance Imaging for Different Types of Orthodontic Material (치과 교정 물질에 따른 자기공명영상의 왜곡)

  • Song, Hyun-Og;Lim, Cheong-Hwan;Lee, Sang-Ho;Yang, Oh-Nam;Baek, Chang-Moo;Jung, Hong-Ryang
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.439-446
    • /
    • 2014
  • To evaluate the effects of an artifact by metal material for orthodontics in Magnetic Resonance Image (MRI) examination, wires and brackets used in orthodontics were selected and compared. Using a head coil, a $T_2$-weighted image, $T_1$-weighted image and FLAIR image were obtained. With obtained images, the sizes of the artifacts were measured and compared using Image J Program. In the research, the material with the biggest artifact in the wires and brackets for orthodontics was stainless steel wire. In the future, selecting and developing metal for correction should be considered also in other fields along with the purpose of orthodontics.

The feasibility of algorithm for iterative metal artifact reduction (iMAR) using customized 3D printing phantom based on the SiPM PET/CT scanner (SiPM PET/CT에서 3D 프린팅 기반 자체제작한 팬텀을 이용한 iMAR 알고리즘 유용성 평가에 관한 연구)

  • Min-Gyu Lee;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.35-40
    • /
    • 2024
  • Purpose: To improve the image quality in positron emission tomography (PET), the attenuation correction technique based on the computed tomography (CT) data is important process. However, the artifact is caused by metal material during PET/CT scan, and the image quality is degraded. Therefore, the purpose of this study was to evaluate image quality according to with and without iterative metal artifact reduction (iMAR) algorithm using customized 3D printing phantom. Materials and Methods: The Hoffman and Derenzo phantoms were designed. To protect the gamma ray transmission and express the metal portion, lead substance was located to the surface. The SiPM based PET/CT was used for acquisition of PET images according to application with and without iMAR algorithm. The quantitative methods were used by signal to noise ratio (SNR), coefficient of variation (COV), and contrast to noise ratio (CNR). Results and Discussion: The results shows that the image quality applying iMAR algorithm was higher 1.15, 1.19, and 1.11 times than image quality without iMAR algorithm for SNR, COV, and CNR. Conclusion: In conclusion, the iMAR algorithm was useful for improvement of image quality by reducing the metal artifact lesion.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Co-evolving with Material Artifacts: Learning Science through Technological Design

  • Hwang, Sung-Won;Roth, Wolff-Michael
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.1
    • /
    • pp.76-89
    • /
    • 2004
  • Recent studies of science and technology "in-the-making" revealed that the process of designing material artifacts is not a straightforward application of prior images or theories by one (or more) person(s) isolated from his or her (their) environment. Rather, designing is a process contingent on the social and material setting for both engineering designers and students. Over the past decade, designing technological artifacts has emerged as an important learning environment in science classrooms. Through the analyses of a large database concerning an innovative simple machines curriculum for sixth-and seventh-grade students, we accumulated valid evidence for the nature of the designing process and science learning through it. In this paper, we show that design actions intertwine with the transformation of the objectified raw materials and artifact, the designer collective, and the mediating tools enabling that transformation, which constitute the elements of an activity from the perspective of cultural-historical activity theory. We conceptualize the continuous change of relation between material artifacts, designers, and tools throughout the design activity as co-evolution. Two episodes were selected to exemplify synchronic and diachronic change of relations inherent in co-evolving activity system. Finally, we discuss the implications of co-evolution during design activity for science learning.

Evaluation of the Utility of Self Produced MRI Radiofrequency Shielding Material (자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가)

  • Lee, Jin-Hoe;Lee, Bo-Woo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.89-94
    • /
    • 2020
  • This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time..