• Title/Summary/Keyword: material and equipment

Search Result 1,525, Processing Time 0.031 seconds

A Study on Improvement of Field Implementation of Asphalt Surface Reinforcement Method (아스팔트 표면 강화공법의 현장 적용성 개선 방안 연구)

  • Jo, Shin Haeng;Kim, Kyungnam;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.389-395
    • /
    • 2017
  • A study was carried out to improve the field implementation of asphalt surface reinforcement method which is a preventive maintenance. Mean Texture Depth (MTD) was measured to quantify the surface condition and used to determine the optimum application rate. Determining the application rate using MTD can reduce the material loss from 30% to 15%. In order to reduce the curing time to 30 minutes, the heat capacity of $317kcal/m^2$ is required. Therefore, the design capacity of the heating curing device requires more than 380,000 kcal/hr. The asphalt surface reinforcement method is preferably applied at a time when slight cracking occurs before the permanent deformation becomes serious. Through the analysis of the pavement survey data, it was decided to apply the surface reinforcement method at the crack rate of 3~4%. Heating the surface reinforcement agent to $50^{\circ}C$ improves workability and ensures sufficient penetration depth even at a crack width of 1 mm. The results will be utilized as basic data for the development of automated construction equipment for efficiency improvement.

A Folkloric Demonstration on 'Sam-gama' The Field Report on the Construction, Structure and Utilization of 'Sam-gama' ('삼가마' 유구에 대한 민속학적논증 '삼가마'(삼굿)의 축조와 구조, 운용에 대한 현지조사 보고)

  • Lim, Hyoung Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.4
    • /
    • pp.4-19
    • /
    • 2009
  • Though admitting that, in light of the recent archaeological trend, the excavation on relics of Sam-gama (a sort of kiln steaming the hemp) is increasingly reported, little efforts by far have been made not only to restore its traditional structure design but also to research hardly the change of hemp-steaming technologies in ages. In this regard, this paper shows the exploration of structural method and design as well as operability with regard to Sam-gut, traditional hemp-processing equipment that was recently reconstructed in Jungsun, Kangwon Province. Samgut, generally positioned at the waterside area, is an traditional device for steaming hemp to get bast fibers from the raw material of hemp, principally consisting of HWA-JIP(fire-place) to obtain steams by feeding fire ad Mong-got(boiling chamber) to make the hemp steamed after stacking. More specifically, thick round-logs were piled at the bottom of Hwajip prior to stacking stones around its circumferential area. When the timber positioned below gets burned with high temperature to heat stones existing in the upper side, waters then poured onto it after laying a bundle of grass and soil up to the boiled stones. If so, there generates hot vapor, which is conveyed to Monggot to steam the hemp. Functionally, it is of outstanding importance that Samgut is capable of producing high-temperature water vapors instantaneously under the intensive manpower, thus being constructed achievable for those purposes. The Samgut made by digging the ground is an instant facility that is closed after use. The remains, which were used to generate higher thermal power for steaming hemp, make it hard to excavate the historic traits because there left little vestiges in the soil, which means keen attention must be paid to find out the trace of Smgama relics. Future research stall be focused on collection of broader data regarding Samgut including technological review in extracting bas fibers from the hemp.

A Study on the Probability of Secondary Carcinogenesis during Gamma Knife Radiosurgery (감마나이프 방사선 수술시 2차 발암 확률에 관한 연구)

  • Joo-Ah, Lee;Gi-Hong, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.843-849
    • /
    • 2022
  • In this study, the probability of secondary carcinogenesis was analyzed by measuring the exposure dose of surrounding normal organs during radiosurgery using a gamma knife. A pediatric phantom (Model 706-G, CIRS, USA) composed of human tissue-equivalent material was set to four tumor volumes of 0.25 cm3, 0.51 cm3, 1.01 cm3, and 2.03 cm3, and the average dose was 18.4 ± 3.4 Gy. After installing the Rando phantom on the table of the gamma knife surgical equipment, the OSLD nanoDot dosimeters were placed in the right eye, left eye, thyroid, thymus gland, right lung, and left lung to measure each exposure dose. The probability of cancer occurrence due to radiation exposure of surrounding normal organs during gamma knife radiosurgery for acoustic schwannoma disease was 4.08 cancers per 100,000 at a tumor volume of 2.03 cm3. This study is expected to be used as useful data in relation to stochastic effects in the future by studying the risk of secondary radiation exposure that can occur during stereotactic radiosurgery.

Fundamental study on sound absorption of a dental hand piece using micro-porous EPP substrate processed by UV laser (UV 레이저응용 마이크로 다공성 EPP 기판의 치과용 핸드피스 흡음성능에 관한 기초연구)

  • You, Dong-Bin;Shin, Myung-Ho;Byun, Hyo-Jin;Choi, Do-Jung;Sung, Kuo-Won;Ma, Yong-Won;Shin, Bo-Sung
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.5
    • /
    • pp.158-164
    • /
    • 2019
  • Recently many studies to reduce the noise of dental hand piece which generate inevitably mechanical sound to offend to the ear of a patient have been spotlighted. Generally, methods of adding a sound absorbing material inside the exhaust valve, air pump of machine or automobile are widely reported as optimal way to reduce the mechanical noise. In this paper we studied a new UV laser aided manufacturing of micro-porous structure of EPP substrate and applied dental hand piece to improve the efficiency of sound absorption. A lot of micro-sized pores were fabricated with UV laser processing on the surface of sliced EPP substrate. From fundamental experiments, more high-performance of micro-porous EPP substrate has finally demonstrated for sound-absorbing structure of the micro muffler inside dental hand piece, which actually has the excellent potential to apply a lot of potable machine.

An Analysis of the Use of Media Materials in School Health Education and Related Factors in Korea (학과보건교육에서의 매체활용실태 및 영향요인 분석)

  • Kim, Young-Im;Jung, Hye-Sun;Ahn, Ji-Young;Park, Jung-Young;Park, Eun-Ok
    • Journal of the Korean Society of School Health
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 1999
  • The objectives of this study are to explain the use of media materials in school health education with other related factors in elementary, middle, and high schools in Korea. The data were collected by questionnaires from June to September in 1998. The number of subjects were 294 school nurses. The PC-SAS program was used for statistical analysis such as percent distribution, chi-squared test, spearman correlation test, and logistic regression. The use of media materials in health education has become extremely common. Unfortunately, much of the early materials were of poor production quality, reflected low levels of interest, and generally did little to enhance health education programming. A recent trend in media materials is a move away from the fact filled production to a more affective, process-oriented approach. There is an obvious need for health educators to use high-quality, polished productions in order to counteract the same levels of quality used by commercial agencies that often promote "unhealthy" lifestyles. Health educators need to be aware of the advantages and disadvantages of the various forms of media. Selecting media materials should be based on more than cost, availability, and personal preference. Selection should be based on the goal of achieving behavioral objectives formulated before the review process begins. The decision to use no media materials rather than something of dubious quality usually be the right decision. Poor-quality, outdated, or boring materials will usually have a detrimental effect on the presentation. Media materials should be viewed as vehicles to enhance learning, not products that will stand in isolation. Process of materials is an essential part of the educational process. The major results were as follows : 1. The elementary schools used the materials more frequently. But the production rate of media materials was not enough. The budget was too small for a wide use of media materials in school health education. These findings suggest that all schools have to increase the budget of health education programs. 2. Computers offer an incredibly diverse set of possibilities for use in health education, ranging from complicated statistical analysis to elementary-school-level health education games. But the use rate of this material was not high. The development of related software is essential. Health educators would be well advised to develop a basic operating knowledge of media equipment. 3. In this study, the most effective materials were films in elementary school and videotapes in middle and high school. Film tends to be a more emotive medium than videotape. The difficulties of media selection involved the small amount of extant educational materials. Media selection is a multifaceted process and should be based on a combination of sound principles. 4. The review of material use following student levels showed that the more the contents were various, the more the use rate was high. 5. Health education videotapes and overhead projectors proved the most plentiful and widest media tools. The information depicted was more likely to be current. As a means to display both text and graphic information, this instructional medium has proven to be both effective and enduring. 6. An analysis of how effective the quality of school nurse and school use of media materials shows a result that is not complete (p=0.1113). But, the budget of health education is a significant variable. The increase of the budget therefore is essential to effective use of media materials. From these results it is recommended that various media materials be developed and be wide used.

  • PDF

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance (이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발)

  • Ki-Yeol Eom;Byeong-Seok Min
    • Journal of Internet Computing and Services
    • /
    • v.25 no.1
    • /
    • pp.99-107
    • /
    • 2024
  • Along with economic growth and industrial development, there is an increasing demand for various electronic components and device production of semiconductor, SMT component, and electrical battery products. However, these products may contain foreign substances coming from manufacturing process such as iron, aluminum, plastic and so on, which could lead to serious problems or malfunctioning of the product, and fire on the electric vehicle. To solve these problems, it is necessary to determine whether there are foreign materials inside the product, and may tests have been done by means of non-destructive testing methodology such as ultrasound ot X-ray. Nevertheless, there are technical challenges and limitation in acquiring X-ray images and determining the presence of foreign materials. In particular Small-sized or low-density foreign materials may not be visible even when X-ray equipment is used, and noise can also make it difficult to detect foreign objects. Moreover, in order to meet the manufacturing speed requirement, the x-ray acquisition time should be reduced, which can result in the very low signal- to-noise ratio(SNR) lowering the foreign material detection accuracy. Therefore, in this paper, we propose a five-step approach to overcome the limitations of low resolution, which make it challenging to detect foreign substances. Firstly, global contrast of X-ray images are increased through histogram stretching methodology. Second, to strengthen the high frequency signal and local contrast, we applied local contrast enhancement technique. Third, to improve the edge clearness, Unsharp masking is applied to enhance edges, making objects more visible. Forth, the super-resolution method of the Residual Dense Block (RDB) is used for noise reduction and image enhancement. Last, the Yolov5 algorithm is employed to train and detect foreign objects after learning. Using the proposed method in this study, experimental results show an improvement of more than 10% in performance metrics such as precision compared to low-density images.

Study on Hydrogen Embrittlement for API 5L X65 Steel Using Small Punch Test I : Base Metal (소형펀치 시험을 이용한 API 5L X65 강의 수소취화에 관한 연구 I : 모재부)

  • Jang, Sang-Yup;Yoon, Kee-Bong
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • Occurrence of hydrogen embrittlement could be one of the main obstacles for using structural equipment under hydrogen environment. It is required to develop assessment methods of hydrogen embrittlement for the metals used in production, storage, transmission and application utilities of hydrogen. The most probable method of hydrogen mass transmission is using existing natural gas pipeline. Base or weld part of the pipeline can be damaged by mixed gas of hydrogen in the pipeline. In this study small punch (SP) testing was employed to evaluate the hydrogen embrittlement behavior for a line pipe steel (API X65) with electrochemically hydrogen charged specimens. Results showed that the SP test can be a good candidate test method for hydrogen damage evaluation method. Strength of steel is known to be decreased with the level of hydrogen charging. However, for API X65 steel base metal need in this study, the effect of hydrogen to strength was not significant. It can be negligible regardless of the hydrogen contents in the steel. With this test different strength levels with various hydrogen charging conditions were observed. It can also be anticipated that more sensitive evaluation of material behavior be obtainable by the SP test method.

Effects of Biomass Gasification by Addition of Steam and Calcined Dolomite in Bubbling Fluidized Beds (기포유동층에서 수증기 및 소성된 백운석 첨가에 의한 바이오매스 가스화의 영향)

  • Jo, WooJin;Jeong, SooHwa;Park, SungJin;Choi, YoungTai;Lee, DongHyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.783-791
    • /
    • 2015
  • A fluidized-bed reactor with an inside diameter of 0.1 m and a height of 1.2 m was used to study the effect of steam and catalyst additions to air-blown biomass gasification on the production of producer gas. The equipment consisted of a fluidized bed reactor, a fuel supply system, a cyclone, a condenser, two receivers, steam generator and gas analyzer. Silica sand with a mean particle diameter of $380{\mu}m$ was used as a bed material and calcined dolomite ($356{\mu}m$), which is effective in tar reduction and producer gas purification, was used as the catalyst. Both of Korea wood pellet (KWP) and a pellet form of EFB (empty fruit bunch) which is the byproduct of Southeast Asia palm oil extraction were examined as biomass feeds. In all the experiments, the feeding rates were 50 g/min for EFB and 38 g/min for KWP, respectively at the reaction temperature of $800^{\circ}C$ and an ER (equivalence ratio) of 0.25. The mixing ratio (0~100 wt%) of catalyst was applied to the bed material. Air or an air-steam mixture was used as the injection gas. The SBR (steam to biomass ratio) was 0.3. The composition, tar content, and lower heating value of the generated producer gas were measured. The addition of calcined dolomite decreased tar content in the producer gas with maximum reduction of 67.3 wt%. The addition of calcined dolomite in the air gasification reduced lower heating value of the producer gas. However The addition of calcined dolomite in the air-steam gasification slightly increased its lower heating value.