• Title/Summary/Keyword: mass transfer coefficients

Search Result 360, Processing Time 0.027 seconds

Separation of Amino Acids by Simulated Moving Bed Using Competitive Langmuir Isotherm

  • Yang, Yun-Jeong;Lee, Chong-Ho;Koo, Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.331-338
    • /
    • 2004
  • The Separation of two amino acids, phenylalanine and tryptophan, was carried out using laboratory simulated moving bed (SMB) chromatography. The SMB process consisted of four zones, with each zone having 2 columns. The triangle theory was used to obtain the operating conditions for the SMB. The mass transfer coefficients of the two amino acids were obtained from the best-fit values by comparing simulated and experimental pulse data. The competitive adsorption isotherms of the two amino acids were obtained by single and binary frontal analyses, taking into consideration the competition between the two components. A competitive Langmuir isotherm, obtained from single-component frontal chromatography, was used in the first run, and the isotherm from binary frontal chromatography in the second, with the flow rate of zone 1 modified to improve the purity. Compared to the first and second runs, the competitive Langmuir isotherm from the binary frontal chromatography Showed good agreement with the experimental results. Also, adjusting the flow rate in zone 1 increased the purity of the products. The purities of the phenylalanine in the raffinate and the tryptophan in the extract were 99.84 and 99.99%, respectively.

Development and Validation of MARS-KS Input Model for SBLOCA Using PHWR Test Facility (중수로 실증 실험설비를 이용한 소형냉각재상실사고의 MARS-KS 입력모델 개발 및 검증계산)

  • Baek, Kyung Lok;Yu, Seon Oh
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2021
  • Multi-dimensional analysis of reactor safety-KINS standard (MARS-KS) is a thermal-hydraulic code to simulate multiple design basis accidents in reactors. The code has been essential to assess nuclear safety, but has mainly focused on light water reactors, which are in the majority in South Korea. Few previous studies considered pressurized heavy water reactor (PHWR) applications. To verify the code applicability for PHWRs, it is necessary to develop MARS-KS input decks under various transient conditions. This study proposes an input model to simulate small-break loss of coolant accidents for PHWRs. The input model includes major equipment and experimental conditions for test B9802. Calculation results for selected variables during steady-state closely follow test data within ±4%. We adopted the Henry-Fauske model to simulate break flow, with coefficients having similar trends to integrated break mass and trip time for the power supply. Transient calculation results for major thermal-hydraulic factors showed good agreement with experimental data, but further study is required to analyze heat transfer and void condensation inside steam generator u-tubes.

An Experimental Study on the Evaporative Heat Transfer Characteristics of R-134a in a Micro-Channel Heat Exchanger (마이크로채널 열교환기에서 R-134a의 증발열전달 특성에 관한 실험적 연구)

  • Lee, Hae-Seung;Jeon, Dong-Soon;Kim, Young-Lyoul;Kim, Yong-Chan;Kim, Seon-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.113-120
    • /
    • 2010
  • An experimental investigation was carried out to examine the evaporative heat transfer characteristics of R-134a in a micro-channel heat exchanger. The micro-channel heat exchanger used in this study was a sort of plate heat exchanger. Micro-channels were fabricated on the SUS304 plate by the photo-etching process: 13 sheets of plates were stacked and bonded by the diffusion bonding process. The effects of the evaporating temperature, mass flux of R-134a, and inlet temperature of water were examined. As the difference between the inlet temperatures of R-134a and water increased, the heat transfer rate increased. The evaporative heat transfer coefficients obtained in this study range from 0.67 to 6.23 kW/m2C. The experimental correlation for the Nusselt number as a function of the Reynold number and Θ was suggested for the micro-channel heat exchanger.

Effect of Hypotonic and Hypertonic Solution on Brining Process for Pork Loin Cube: Mass Transfer Kinetics (돼지고기 등심의 염지공정에서 소금농도의 영향: 물질전달 동역학을 중심으로)

  • Park, Min;Lee, Nak Hun;In, Ye-Won;Oh, Sang-Yup;Cho, Hyung-Yong
    • Food Engineering Progress
    • /
    • v.23 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • The impregnation of solid foods into the surrounding hypotonic or hypertonic solution was explored as a method to infuse NaCl in pork loin cube without altering its matrix. Mass transfer kinetics using a diffusive model as the mathematical model for moisture gain/loss and salt gain and the resulting textural properties were studied for the surrounding solutions of NaCl 2.5, 5.0, 10.0 and 15% (w/w). It was possible to access the effects of brine concentration on the direction of the resulting water flow, quantify water and salt transfer, and confirm tenderization effect by salt infusion. For brine concentrations up to 10% it was verified that meat samples gained water, while for processes with 15% concentration, pork loin cubes lost water. The effective diffusion coefficients of salt ranged from 2.43×10-9 to 3.53×10-9 m2/s, while for the values of water ranged from 1.22×10-9 to 1.88×10-9 m2/s. The diffusive model was able to represent well salt gain rates using a single parameter, i.e. an effective diffusion coefficient of salt through the meat. However, it was not possible to find a characteristic effective diffusion coefficient for water transfer. Within the range of experimental conditions studied, salt-impregnated samples by 5% (w/w) brine were shown with minimum hardness, chewiness and shear force.

Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes (세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성)

  • Son, Chang-Hyo
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • An experimental study to investigate the condensing heat transfer characteristics of small diameter horizontal double pipe heat exchangers with R-22 and R-410A was performed. Experimental facility was constructed to calculate and observe HTC(heat transfer coefficients), flow patterns and pressure drop. The main components include a liquid pump, an evaporator, a condenser(test section), a sight-glass, pressure taps and measurement apparatus. Two pipes of different diameters are tested; One 5.35 mm ID 0.5 mm thick, the other 3.36 mm ID 0.7 mm thick. The mass flow rate ranged from 200 to 500ks/m2s and heating capacity were form 1.0 to 2.4 kW. The flow patterns of R-22 and R-410A were observed with a high speed camera through the sight-glass. The tests revealed that HTC of R-410A was higher than that of R-22 by maximum 5%. Annular pattern was observed for the most cases but stratified flow was also detected when x<0.2. The pressure drop in 3.36 mm ID pipe was higher than that of 5.35 mm by 3050. Comparing with previous correlations such as Shah, Fujii and Soliman's, Fujii' showed the best good agreement with my data with a maximum deviation of 40%.

  • PDF

Development of Optimum PAC Dose Prediction Program using 14C-radiolabled MIB and HSDM (14C-radiolabeled MIB와 HSDM을 이용한 최적 PAC 투입량 예측프로그램의 개발)

  • Kim, Young-Il;Bae, Byung-Uk;Kim, Kyu-Hyoung;Hong, Hyun-Su;Westerhoff, Paul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1123-1128
    • /
    • 2005
  • NIB(methylisoborneol) is an earthy/musty odor compound produced as a second metabolite by cyanobacteria and actinomycetes. MIB is not removed by conventional water treatment(coagulation, sedimentation, filtration) and its presence in tap water, even at low ng/L levels, can result in consumer complaints. PAC(powdered activated carbon) can effectively remove MIB when the correct dose is applied. But, since most operators in water treatment plants apply a PAC dose and then adjust that dose depending on direct observation (odor detection) after treatment, the result is often under-dose or eve,-dose. In this study, kinetic and isotherm tests using 14C-radiolabeled MIB were performed to determine coefficients for the HSDM(homogeneous surface diffusion model), including liquid film mass transfer coefficient(Kf) and surface diffusion coefficient (Ds). The HSDM gave a reasonable fit and allowed prediction with the experimental data. Base on the HSDM, the authors developed an optimum PAC dose prediction program using the Excel spreadsheet. When the developed program was applied at two water treatment plants, the PAC dose based on the experience of operators in the water treatment plant was significantly different from that recommended by the newly developed program. If operators are willing to use the optimum PAC dose prediction program, it should solve dosing problems.

Molecular dynamics study of liquid sodium film evaporation and condensation by Lennard-Jones potential

  • Wang, Zetao;Guo, Kailun;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, Guanghui
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3117-3129
    • /
    • 2022
  • Deeply understanding the phase change of thin liquid sodium film inside wick pore is very important for further studying high-temperature sodium heat pipe's heat transfer. For the first time, the evaporation and condensation of thin liquid sodium film are investigated by the Lennard-Jones potential of molecular dynamics. Based on the startup and normal operation of the sodium heat pipe, three different cases are simulated. First, the equilibrium is achieved and the Mass Accommodation Coefficients of the three cases are 0.3886, 0.2119, 0.2615 respectively. Secondly, the non-equilibrium is built. The change of liquid film thickness, the number of gas atoms, the net evaporation flux (Jnet), the heat transfer coefficient (h) at the liquid-gas interface are acquired. Results indicate that the magnitude of the Jnet and the h increase with the basic equilibrium temperature. In 520-600 K (the startup of the heat pipe), the h has approached 5-6 W m-2 K-1 while liquid film thickness is in 11-13 nm. The fact shows that during the initial startup of the sodium heat pipe, the thermal resistance at the liquid-gas interface can't be negligible. This work is the complement and extension for macroscopic investigation of heat transfer inside sodium heat pipe. It can provide a reference for further numerical simulation and optimal design of the sodium heat pipe in the future.

The Prediction of Solvent Mutual Diffusion Coefficient Using Vrentas-Duda's Self Diffusion Theory (Vrentas-Duda의 자기확산이론을 이용한 용매의 상호확산계수 예측)

  • 김종수;이광래;김기창
    • Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.19-29
    • /
    • 2000
  • To estimatc mutual diffusion coefficient for the analysis of mass transfer phenomena in polymer/solvent system, two models are proposed and the equations are derived. The estimates of mutual diffusion coefficients are obtained by two models suggested in this work and compared with and experimental data and Vrentas-Duda's. Vrentas-Duda's self diffusion coefficient was used for the mutual diffusion coefficient. Derivative of chemical potential on solvent was derived and used using original UNIFAC-FV and modified UNIFAC-FV. However, Vrentas-Duda's equation for mutual diffusion coefficient contains Flory-Huggins parameter x. For the derivative of chemical potential term, Vrentas-Duda assumed that parameter x was constant and independent of temperatures and concentrations The assumption is one of shortcoming in vrentas-Duda's mutual diffusion coefficient. New methods proposed in this work do not have such assumptions and simplifications. For the solvent of cyclohexane, n-pentane, and n-hexane in PIB(polyisolbutylene) and PMS-BR (poly(p-methylstyrene-co-isobutylene), new methods well correlate the experimental data at various temperatures and concentrations, and predicted the experimental data much better than Vrentas-Duda's for the PIB/toluene system. It is shown that new methods are excellent tools for correlating mutual diffusion coefficient data in polymer/solvent system over wide ranges of temperature and concentration without any assumptions or simplifications.

  • PDF

Simulation of nanosilver migration from polystyrene nanocomposite into food simulants

  • Soleimani, Jaber;Ghanbarzadeh, Babak;Dehgannya, Jalal;Islami, Sima Baheri;Sorouraddin, Saeed M.
    • Advances in nano research
    • /
    • v.6 no.3
    • /
    • pp.243-255
    • /
    • 2018
  • Polystyrene granules were combined with nanosilver to form a nanocomposite film. One-side migration was conducted to test into three food simulants (3% acetic acid, 10% ethanol and 95% ethanol) at 40C temperature on different period of time (2, 4, 6, 8 and 10 days). It was found that, among the simulants, the highest migration amount was obtained with 3% acetic acid, while the 95% ethanol revealed the least migration level. Diffusion coefficients of nanosilver particles into simulants were estimated by inverse simulation using experimental data of concentration variation in the simulants. The finite element method used to solve the mass transfer equation and the numerical results indicates the sameresponse with the experimental data. The numerical results confirmed that the highest diffusion coefficient for acetic acid 3% (1.82E-10 to 1.76E9m2s1) and the lowest diffusion coefficient for ethanol 95% from 2 to 10 days were obtained, respectively. Also, results of diffusion coefficient - concentration relation showed, the diffusion coefficient had in direct correlation with time and concentration. The results indicated that, in the 3% acetic acid, due to the increasing of diffusion coefficient of silver nanoparticles, they are released faster and distributed uniformly.

Development of ACBIO: A Biosphere Template Using AMBER for a Potential Radioactive Waste Repository (AMBER를 이용한 방사성폐기물처분장 생태계 평가 템플릿 ACBIO 개발)

  • Lee Youn-Myoung;Hwang Yongsoo;Kang Chul-Hyung;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.213-229
    • /
    • 2005
  • Nuclides in radioactive wastes are assumed to be transported in the geosphere by groundwater and probably discharged into the biosphere. Quantitative evaluation of doses to human beings due to nuclide transport in the geosphere and through the various pathways in the biosphere is the final step of safety assessment of the radioactive waste repository. To calculate the flux to dose conversion factors (DCFs) for nuclides appearing at GBIs with their decay chains, a template ACBIO which is an AMBER case file based on mathematical model for the mass transfer coefficients between the compartments has been developed considering material balance among the compartments in biosphere and then implementing to AMBER, a general and flexible software tool that allows to build dynamic compartment models. An illustrative calculation with ACBIO is shown.

  • PDF