• 제목/요약/키워드: mass structures

검색결과 2,078건 처리시간 0.023초

High performance active tuned mass damper inerter for structures under the ground acceleration

  • Li, Chunxiang;Cao, Liyuan
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.149-163
    • /
    • 2019
  • By integrating an active tuned mass damper (ATMD) and an inerter, the ATMDI has been proposed to attenuate undesirable oscillations of structures under the ground acceleration. Employing the mode generalized system, the dynamic magnification factors (DMF) of the structure-ATMDI system are formulated. The criterion can then be defined as the minimization of maximum values of the DMF of the controlled structure for optimum searching. By resorting to the defined criterion and the particle swarm optimization (PSO), the effects of varying the crucial parameters on the performance of ATMDI have been scrutinized in order to probe into its superiority. Furthermore, the results of both ATMD and tuned mass dampers inerter (TMDI) are included into consideration for comparing. Results corroborate that the ATMDI outperforms both ATMD and TMDI in terms of the effectiveness and robustness. Especially, the ATMDI may greatly reduce the demand on both the mass ratio and inerter mass ratio, thus being capable of further miniaturizing both the ATMD and TMDI. Likewise the miniaturized ATMDI still keeps nearly the same stroke as the TMDI with a larger mass ratio. Hence, the ATMDI is deemed to be a high performance control device with the miniaturization and suitable for super-tall buildings.

TMD effectiveness in nonlinear RC structures subjected to near fault earthquakes

  • Domizio, Martin N.;Ambrosini, Daniel;Curadelli, Oscar
    • Smart Structures and Systems
    • /
    • 제24권4호
    • /
    • pp.447-457
    • /
    • 2019
  • The use of Tuned mass dampers (TMD) has proved to be effective in reducing the effects of vibrations caused by wind loads and far-field seismic action. However, its effectiveness in controlling the dynamic response of structures under near-fault earthquakes is still under discussion. In this case, the uncertainty about the TMD performance arises from the short significant duration of near-fault ground motions. In this work, the TMD effectiveness for increasing the safety margin against collapse of structures subjected to near-fault earthquakes is investigated. In order to evaluate the TMD performance in the proposed scenario, the nonlinear dynamic response of two reinforced concrete (RC) frames was analyzed. TMDs with different mass values were added to these structures, and a set of near-fault records with frequency content close to the fundamental frequency of the structure was employed. Through a series of nonlinear dynamic analysis, the minimum amplitude of each seismic record that causes the structural collapse was found. By comparing this value, called collapse acceleration, for the case of the structures with and without TMD, the benefit produced by the addition of the control device was established.

다양한 형상 변화에 따른 에너지 수확용 블록 구조의 동적 특성 및 압전 효과 (Dynamic Characteristics and Piezoelectric Effect of Energy Harvesting Block Structures with Different Shapes)

  • 노명현;이상열
    • 대한토목학회논문집
    • /
    • 제32권6A호
    • /
    • pp.379-387
    • /
    • 2012
  • 본 연구에서는 새로운 에너지 수확용 Multi-layer 블록 구조를 제시하고 고체 및 Shell 유한 요소를 사용하여 다양한 기하학적 형상 변화에 대한 자유진동 특성을 분석하고 압전 성능을 실험적으로 평가한다. 본 연구에서 제시하는 블록 구조에 대한 2차원 및 3차원 유한요소 모델은 해석의 정확성 뿐 만 아니라 전체 진동 모드를 정확히 보여준다는 점에서 장점을 갖는다. ABAQUS가 적용된 유한요소 모델은 다양한 Tip mass 및 PZT 변화에 따른 Multi-layer 블록 구조의 자유진동을 분석하기 위하여 사용되었다. 특히, 본 연구에서 제시한 결과는 블록구조 전체의 기하학적 형상, Tip mass 및 Hole의 유무, Tip mass 및 PZT의 위치변화 등에 대하여 국부 및 전체 진동 모드에 미치는 중요한 영향들에 대하여 초점을 둔다. 또한, 실험실 규모의 실제 모형 실험을 수행하여 개발한 에너지 블록구조의 발전성능을 평가하였다.

Evaluating the accuracy of mass scaling method in non-linear quasi-static finite element analysis of RC structures

  • A. Yeganeh-Salman;M. Lezgy-Nazargah
    • Structural Engineering and Mechanics
    • /
    • 제85권4호
    • /
    • pp.485-500
    • /
    • 2023
  • The non-linear static analysis of reinforced concrete (RC) structures using the three-dimensional (3D) finite element method is a time-consuming and challenging task. Moreover, this type of analysis encounters numerical problems such as the lack of convergence of results in the stages of growth and propagation of cracks in the structure. The time integration analysis along with the mass scaling (MS) technique is usually used to overcome these limitations. Despite the use of this method in the 3D finite element analysis of RC structures, a comprehensive study has not been conducted so far to assess the effects of the MS method on the accuracy of results. This study aims to evaluate the accuracy of the MS method in the non-linear quasi-static finite element analysis of RC structures. To this aim, different types of RC structures were simulated using the finite element approach based on the implicit time integration method and the mass scaling technique. The influences of effective parameters of the MS method (i.e., the allowable values of increase in the mass of the RC structure, the relationship between the duration of the applied load and fundamental vibration period of the RC structure, and the pattern of applied loads) on the accuracy of the simulated results were investigated. The accuracy of numerical simulation results has been evaluated through comparison with existing experimental data. The results of this study show that the achievement of accurate structural responses in the implicit time integration analyses using the MS method involves the appropriate selection of the effective parameters of the MS method.

Optimum parameters and performance of tuned mass damper-inerter for base-isolated structures

  • Jangid, Radhey Shyam
    • Smart Structures and Systems
    • /
    • 제29권4호
    • /
    • pp.549-560
    • /
    • 2022
  • The optimum damping and tuning frequency ratio of the tuned mass damper-inerter (TMDI) for the base-isolated structure is obtained using the numerical searching technique under stationary white-noise and filtered white-noise earthquake excitation. The minimization of the isolated structure's mean-square relative displacement and absolute acceleration, as well as the maximization of the energy dissipation index, were chosen as the criteria for optimality. Using a curve-fitting technique, explicit formulae for TMDI damping and tuning frequency for white-noise excitation are then derived. The proposed empirical expressions for TMDI parameters are found to have a negligible error, making them useful for the effective design of base-isolated structures. The effectiveness of TMDI and its optimum parameters are influenced by the soil condition and isolation frequency, according to the comparison made of the optimized parameters and response with different soil profiles. The effectiveness of an optimally designed TMDI in controlling the displacement and acceleration response of the flexible isolated structure under real and pulse-type earthquakes is also observed and found to be increased as the inertance mass ratio increases.

접수탱크구조의 진동특성에 관한 연구 (A Study on Vibration Characteristics in Water Tank Structure)

  • 배성용
    • 대한조선학회논문집
    • /
    • 제40권4호
    • /
    • pp.46-52
    • /
    • 2003
  • In ship structures, many parts are in contact with inner or outer fluid as stern, ballast and oil tanks. Fatigue damages can be sometimes observed in these tanks which seem to be caused by resonance. Tank structures in ships are in contact with water and the vibration characteristics are strongly affected by the added mass of containing water. Therefore it is important to predict vibration characteristics of tank structures. In order to estimate the vibration characteristics, the fluid-structure interaction problem has to be solved precisely. In the present paper, we have developed a numerical tool of vibration analysis of 3-dimensional tank structures using finite elements for plates and boundary elements for water region. To verify the present analysis, we have made an experiment for vibration characteristics of a tank with elastic opposite panels. And the added mass effect of containing water and the effect of structural constraint between panels are investigated numerically and discussed.

The Mechanical Properties of High Strength Concrete in Massive Structures

  • Park, Ki-Bong
    • Architectural research
    • /
    • 제15권1호
    • /
    • pp.53-58
    • /
    • 2013
  • High strength concrete is being used increasingly in mass structure projects. The purpose of this study is to investigate the influence of temperature during mixing, placing and curing on the strength development, hydration products and pore structures of high strength concrete in mass structures. The experiments were conducted with two different model walls, viz.: 1.5 m and 0.3 m under typical summer and winter weather conditions. The final part of this study deal with the clarification of the relationship between the long-term strength loss and the microstructure of the high strength concrete at high temperatures. Test results indicated that high elevated temperatures in mass concrete structures significantly accelerate the strength development of concrete at the early ages, while the long-term strength development is decreased. The long-term strength loss is caused by the decomposition of ettringite and increased the total porosity and amount of small pores.

Seismic behavior of suspended building structures with semi-rigid connections

  • Liu, Yuxin;Lu, Zhitao
    • Earthquakes and Structures
    • /
    • 제7권4호
    • /
    • pp.415-448
    • /
    • 2014
  • A method is presented in this paper to analyze the dynamic response behavior of suspended building structures. The effect of semi-rigid connections that link suspended floors with their supporting structure on structural performance is investigated. The connections, like the restrains in non-structural suspended components, are designed as semi-rigid to avoid pounding and as energy dissipation components to reduce structural response. Parametric study is conducted to assess the dynamic characteristics of suspended building structures with varying connection stiffness and suspended mass ratios. Modal analysis is applied to identify the two distinct sets of vibration modes, pendulum and bearing, of a suspended building structure. The cumulative modal mass is discussed to ensure the accuracy in applying the method of response spectrum analysis by SRSS or CQC modal combination. Case studies indicate that a suspended building having semi-rigid connections and proper suspended mass ratios can avoid local pounding failure and reduce seismic response.

Characterization of Ion Fragmentations of Fatty Acids

  • 최성신
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권6호
    • /
    • pp.573-578
    • /
    • 1997
  • Ion fragmentations of fatty acids such as stearic acid, palmitic acid, myristic acid, and lauric acid were studied using mass spectrometry and semiempirical calculations. The mass spectra of fatty acids showed the distributions of CH₃(CH₂)$_n^+$ and $[(CH_2)_nCO_2H]^+$ fragment ions. The relative ion abundance distributions of $[(CH_2)_nCO_2H]^+$ showed the local maxima at n=6, 10, and 14. The local maximum phenomena were also found in the mass spectra of methyl stearate but not in those of normal alcohols. These local maxima could be explained not by heats of reaction for fragmentation but by the cyclic structures of the molecular ions. The AM1 semiempirical calculations for fatty acids clearly show that the linear structures are more favorable than the cyclic ones for neutral molecules while the cyclic structures are more favorable than the linear ones for ionic molecules. The distances between carboxyl group and methylene of the cylic structures of ionized fatty acids were calculated. The methylene carbons with n=6, 10, and 14 were closer to the carboxyl group than adjacent ones.

매스콘크리트 수화발열 특성의 정량화를 위한 실험적 연구 (An Experimental Study on the Quantification of Hydration Heat Evolution in Mass Concrete)

  • 이장화;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.238-242
    • /
    • 1994
  • Recently, construction of mass concrete structures except Dam are increased very often. Generation heat due to the hydrating reaction of mass concrete is generally larger than the heat released to the air, foundations and the exist structures. Therefore, internal temperature of mass concrete is remarkably risen and temperature gap between center and surface is extended by various effect. It this gap get large, the crack may be occurred. This crack must be controlled as little as possible to ensure the soundness and durability of structure. Firstly, Temperature rising history of Mass concrete is expected correctly to constrain the crack of mass concrete. So, objectives of this research is to quantify the effects of hydration temperature for the purpose of evaluating accurately the temperature history of mass concrete.

  • PDF