• Title/Summary/Keyword: mass size

Search Result 2,510, Processing Time 0.031 seconds

Fragmentation Fractal Analysis on Particle-size Distribution (Fragmentation 프랙탈을 이용한 입도분포 분석)

  • 민덕기;이완진
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.199-206
    • /
    • 2003
  • Particle-size distribution in soils is one of the most fundamental physical properties of soils. One of the latest developments in the study of particle-size distributions has focused on the use of fractal theories. In this study, the fragmentation fractals were used for determining the characteristics of the particle-size distribution curve. It was shown that the mass-size distribution method was more practical than the cumulative number-size distribution method. From the co-relation between fractal dimensions($D_{tot}$) and the coefficient of uniformity($C_{u}$), there was a sharp increase in fractal dimensions for $C_{u}$<4, but fractal dimension converged the single value for $D_{u}$$\geq$6. Fractal dimensions were affected by small sized particles for $C_{c}$$\geq$3 and large sized particles for $C_{c}$/<3. As a result of the analysis of the influence of the effective size($D_{10}$), it was observed that the changes of $D_{tot}$/ were nominal beyond the effective size.

The fabrication of micro mass flow sensor by Micro-machining Technology (Micromachining 기술을 이용한 micro mass flow sensor의 제작)

  • Eoh, Soo-Hae;Choi, Se-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.481-485
    • /
    • 1987
  • The fabrication of a micro mass flow sensor on a silicon chip by means of micro-machining technology is described on this paper. The operation of micro mass flow sensor is based on the heat transfer from a heated chip to a fluid. The temperature differences on the chip is a measure for the flow velocity in a plane parallel with the chip surface. An anisotropic etching technigue was used for the formation of the V-type groove in this fabrication. The micro mass flow sensor is made up of two main parts ; A thin glass plate embodying the connecting parts and mass flow sensor parts in silicon chip. This sensor have a very small size and a neglible dead space. Micro mass flow sensor can fabricate on silicon chip by micro machining technology too.

  • PDF

A Numerical Study on the Response of Jointed Rock Mass Due to Thermal Loading of Radioactive Waste (방사성 폐기물의 열하중에 의한 절리암반의 거동에 관한 수치해석적 연구)

  • 문현구;주광수
    • Tunnel and Underground Space
    • /
    • v.4 no.2
    • /
    • pp.102-118
    • /
    • 1994
  • Thermomechanical analysis is conducted on the radioactive repository in deep rock mass considering the in-situ stress, excavation and thermal loading of a radioactive waste. Thermomechanical properties of a discontinuous rock mass are estimated by a theoretical method so called sequential analysis. Using the estimated properties as input for finite element analysis, the influence on temperature distribution and thermal stress is analyzed within the scope of 2-dimensional steady state and transient heat transfer and coupled thermal elastic plastic behaviour. Granitic rock mass is taken for this analysis. The analysis is done for two different rock mass conditions, i.e. continuous-homogeneous and highly jointed conditions, for the purpose of comparison. In the case of steady state, the extent of disturbed zone around the storage tunnel due to the heat production of the spent-fuel canister varies depending on the thermomechanical properties of the rock mass. In the case of transient analyses, the response of the jointed rock mass to the thermal loading after radioactive waste disposal varies significantly with time, resulting in dramatic changes in the both size and location of disturbed zone.

  • PDF

Infiltrative Lipoma Invading the Anal Sac in a Dog: A Rare Case Report

  • Junyoung Kim;Dai Jung Chung;Jihye Choi;Junghee Yoon
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.147-151
    • /
    • 2023
  • A 6-year-old female Chihuahua was presented to the Animal Medical Center for surgical resection of a perineal mass that had recently increased in size. Ultrasonography revealed a large, homogeneous fatty mass with irregular margins between the surrounding muscle layers due to infiltrating fatty tissues. Cytological findings from fine-needle aspirates revealed numerous sheets and clusters of adipocytes, which was consistent with the fatty mass. Based on ultrasonographic and cytological findings, an infiltrative lipoma was suspected. During the surgery, the perineal mass was found to be non-encapsulated, irregularly marginated, and extensively distributed into the surrounding muscles. The mass extended inside the pelvic cavity and left anal sac. The perineal mass was surgically removed and submitted for histopathologic examination. Histopathology confirmed that the mass was an infiltrative lipoma invading into the anal sac and surrounding muscles. The present report was an unusual presentation of infiltrative lipoma that invaded the anal sac in the perineum.

Seasonal Variation of Size Distributions of Polycyclic Aromatic Hydrocarbons in Air Particulates (대기 부유분진중 다환방향족 탄화수오류의 계절적 입경농도 분포 변이)

  • Chung, Yong;Park, Seong-Eun;Hwang, Man-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.577-588
    • /
    • 1998
  • Polycyclic aromatic hydrocarbons (PAHs) are products of incomplete combustion and, in urban area atmosphere, are mainly traffic or heating in origin. Size-segregated aerosol samples were collected on the Eixth story of Shinchon on the Yonsei campus, using a high-volume cascade impactor, between August 1994 and September 1995. Ten PAHs were analyzed by GC/MSD. The size distribution of PAH-containing particulates followed approximately a log-normal relationship with the majority of PAH content associated with particles below 3.0mm. PAHs concentration in submicron particles increased during the winter months. The Mass Median Diameter (MMD) value of annual particulates in the heavy traffic area of Shinchon shows about 1.6 pm. The MMD values of air particulate in winter were the lowest values and similar to that in summer, while MMD values of seasonal PAHs were generally lower than 1.0 pm. Among the PAHs, MMD values of PAHs with the more than 5 benzen ring were averagely lower than those with 4 benzin rings. Especially MMD's of dibenzo (a, h) anthracene in winter was clearly lower than in summer. This reason may be caused by fuels used for heating. In this area, 50∼80% PAHs mass was particles smaller than 1.0mm aerodynamic diameter in size range, and the MMD values of PAHs lower than those of other country's area.

  • PDF

Estimation of Optimum Capacity for Rainwater Storage Facilities based on Mass Balance and Economic Analysis (Mass-balance 및 경제성 분석에 의한 빗물저류시설 적정 규모 산정)

  • Kim, Youngmin;Lee, Sangho;Lee, Jung-Hun;Kim, Ree-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.233-238
    • /
    • 2008
  • Recently, rainwater harvesting facilities have increasingly constructed mainly in elementary schools and government buildings. Nevertheless, few methods are available for efficient planning and design of rainwater harvesting facilities by considering the weather conditions and purpose of rainwater management in each site, which may lead to a construction of uneconomic facilities. The current method estimates the size of rainwater storage tank by multiplying the size of building or plottage with a certain ratio and has many limitations. In this study, we first developed a method for planning and design of rainwater storage facilities using $Rainstock^{TM}$ model, which is based on mass balance, and economic analysis. Then, the model was applied for the design of a rainwater harvesting facility in a building with the catchment area of $1,000m^2$. The model calculation indicated that the economic feasibility of rainwater harvesting depends on not only the size of storage tank but also the water usage rate. When the water usage rate is $1m^3/day$, the rainwater harvesting facility is not cost-effective regardless of the size of the storage tank. With increasing the water usage rate, the economical efficiency of the facility was improved for a specific size of the storage tank. Based on the model calculation, the optimum tank sizes for $5m^3/day$ and $10m^3/day$ of water usage rates were $24m^3$ and $57m^3$, respectively. It is expected that the model is useful for optimization of rainwater storage facilities in planning and designing steps.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

A Study on the Radial Spray Performance of a Plaint-Jet Twin-Fluid Nozzle (액주형 이류체노즐의 반경반향 분무특성에 관한 연구)

  • 최진철;노병준;강신재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.662-669
    • /
    • 1994
  • In the combustion system, the optimum spray conditions reduce the pollutant emission of exhaust gas and enhance the fuel efficiency. The spray characteristics-the drop size, the drop velocity, the number density and the mass flux, become increasingly important in the design of combustor and in testifying numerical simulation of spray flow in the combustor. The purposes of this study are to clarify the spray characteristics of twin-fluid nozzle and to offer the data for combustor design and the numerical simulation of a spray flow. Spatial drop diameter was measured by immersion sampling method. The mean diameter, size distribution and uniformity of drop were analyzed with variations of air/liquid mass flow ratio. The results show that the SMD increases with the liquid supply flow rate and decreases with the air supply velocity. The radial distribution of SMD shows the larger drops can diffuse farther to the boundary of spray. And the drop size range is found to be wider close to the spray boundary where the maximum SMD locates.

Water Repellent Coating of Carbon Cloth with Different Size PTFE and Gas Permeabilities (PTFE 크기 변화에 따른 Carbon Cloth 발수 코팅과 가스 투과도 변화)

  • Jeon, Hyeon;Cho, Tae-Hwan;Choi, Weon-Kyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.4
    • /
    • pp.313-320
    • /
    • 2010
  • Carbon cloth was impregnated into PTFE emulsion. PTFE is a fluoropolymer used as a coating material in various fields due to its hydrophobicity and excellent mechanical properties. In this study, PTFE emulsion was prepared different particle size of 5~500 nm and $3{\sim}5{\mu}m$. FE-SEM and FT-IR spectroscopy were used microscopic observation and investigation of chemical structure change after PTFE coating. Mass variations, gas permeability and water contact angles were analyzed to determine a GDL performance of PTFE coated carbon cloth. PTFE coated carbon cloth show different mass increase according as PTFE concentration and the number of coating times. Water contact angle of PTFE coated carbon cloth was not effected by size of PTFE particle and the number of coating time; meanwhile, gas permeability was rapidly changed at carbon cloth coated by emulsion with size of $3{\sim}5{\mu}m$ PTFE particle.

Investigation on Flocculi-floc Interaction and Flocculation in Extracellular Polymeric Substances, Ionic Species and Clay-containing Suspension (생체고분자물질 농도와 이온강도에 따른 점토입자 현탁액의 응집핵-응집체 이군집 응집 특성 연구)

  • Kim, Jae In;Lee, Byung Joon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.3
    • /
    • pp.185-193
    • /
    • 2020
  • Bimodal flocculation describes the aggregation and breakage processes of the flocculi (or primary particles) and the flocs in the water environment. Bimodal flocculation causes bimodal size distribution with the two separate peaks of the flocculi and the flocs. Extracellular polymeric substances and ionic species common in the water environment increase the occurrence of bimodal flocculation and flocculi-floc size distribution, under the flocculation mechanisms of electrostatic attraction and polymeric bridging. This study investigated bimodal flocculation and flocculi-floc size distribution, with respect to the extracellular polymeric substance concentration and ionic strength in the kaolinite-containing suspension. The batch flocculation tests comprising 0.12 g/L of kaolinite showed that the highest flocculation potential occurred at the lowest xanthan gum (as extracellular polymeric substances) concentration, under all the ionic strengths of 0.001, 0.01, and 0.1 M NaCl. Also, it was important to note that the higher ionic strength resulted in the higher flocculation potential, at all the xanthan gum concentrations. The bimodal flocculation and flocculi-floc size distribution became apparent in the experimental conditions, which had low and intermediate flocculation potential. Besides the polymeric bridging flocculation, steric stabilization increased the flocculi mass fraction against the floc mass fraction, thereby developing the bimodal size distribution.