• Title/Summary/Keyword: mass sensing

Search Result 210, Processing Time 0.028 seconds

Pyroelectric Infrared Microsensors Made for Human Body Detection (인체 감지용 강유전체 박막 초전형 적외선 센서의 제작)

  • Choi, Jun-Rim
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.103-110
    • /
    • 1998
  • Pyroelectric infrared detectors based on La-modified $PbTiO_{3}$ (PLT) thin films have been fabricated by RF magnetron sputtering and rnicrornachining technology. The detectors form $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) thin film ferroelectric capacitors epitaxially grown by RF magnetron sputtering on Pt/MgO (100) substrate. The sputtered PLT thin film exhibits highly c-axis oriented crystal structure that no poling treatment for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency. Polymide is coated on top of the sensing elements to support the fragile structure and the backside of the MgO substrate is selectively etched to reduce the heat loss. The sensing element exhibited a very high detectivity D* of $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$ at room temperature and it is about 100 times higher than the case of micromachining technology is not used. A sensing system that detects the position as well as the existence of a human body is realized using the array sensor.

  • PDF

Trans-acting regulation and Arsenite sensing properties of ars operon

  • Lee, Soo-Chan;Lee, Sung-Jae;Lee, Ho-Sa
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.141-141
    • /
    • 2001
  • The arsenic resistance operon from pMH12 in Klebsiella oxytoca contains two regulatory genes. The first open reading frame for arsR extend up to 348 bp and has a translational product corresponding to a protein of 116 amino acid residue polypeptide with a molecular mass of 13 kDa. And the second ORF for arsD extend up to 360 bp and express a protein of 120 amino anid residue polypeptide with 13kDa. (omitted)

  • PDF

분포함수 기반 Mass 함수 추정을 통한 Dempster-Shafer 영상융합

  • Lee Sang-Hun
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.311-314
    • /
    • 2006
  • 본 연구에서는 서로 다른 센서간의 영상 자료 융합을 위하여 Dempster-Shafer 기법을 제안하고 있다. 제안 된 Dempster-Shafer 기법은 불확실성의 최소 값을 대표하는 Belief 함수와 불확실성의 최대 값을 나타내는 Plausibility 함수를 사용한다. 이러한 두 함수의 차이는 Belief Interval 로 정의되며 이 값은 분석 대상에 존재하는 불확실 정도의 Measure 로 사용되며 Evidence Combination의 이론에 근거하여 서로 다른 센서간의 자료 융합이 가능하며 분류 결과로 클래스 맵 뿐 만 아니라 분류 결과에 대한 불확실성 정도를 나타내는 Belief 함수 값과 Plausibility 함수 값을 생성하여 분류 결과에 대한 보충적인 분석을 가능하게 하여 사용자의 분석 정확성을 증대 시킬 수 있다.

  • PDF

Development of a single-structured MEMS gyro-accelerometer

  • Sung, Woon-Tahk;Lee, Jang-Gyu;Kang, Tae-Sam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.592-595
    • /
    • 2004
  • This paper presents a study on the development of a multi-sensing inertial sensor with a single mechanical structure, which can be used both as a gyroscope and an accelerometer. The proposed MEMS gyro-accelerometer is designed to detect the angular rate and the acceleration at the same time using two separate detection circuits for one proof mass. In this study, the detection and signal processing circuit for an effective signal processing of different inertial measurements is designed, fabricated, and tested. The experimental results show that the performances of the gyro-accelerometer have resolutions of 1mg and 0.025deg/sec and nonlinearities of less than 0.5% for the accelerometer and the gyroscope, respectively, which are similar results with those of sensors with different structures and different detection circuits. The size of the sensor is reduced almost by 50% comparing with the sensors of separated proof mass.

  • PDF

Performance Evaluation of Explosive Specific Bio-receptor Using QCM Sensing Platform for Resonance Frequency Shift Detection (공진점변화검출용 QCM 센싱플랫폼을 이용한 폭발물 특이적 바이오수용체 성능평가)

  • Lim, Si-Hyung;Jeong, Hyun-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.280-284
    • /
    • 2011
  • The mass change during the molecular interaction between explosive specific bio-receptors and target molecules has been measured using quartz crystal microbalance(QCM), which has a mass change detection limit up to ~ng/$cm^2$. The environmental effect on the molecular interaction has been evaluated. In the liquid phase molecular interaction experiments, the high selectivity of the bio-receptor to DNT compared with toluene has been shown and the sensitivity for various concentrations of DNT has been demonstrated.

Detection of Asian Dust Air-mass based on Short Wavelength Observation of SeaWiFS

  • Fukushima, H.;Hagihara, Y.;Hoshikuma, Y.;Ohta, S.;Uno, I.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1203-1205
    • /
    • 2003
  • To detect dust-loaded air-mass over land and ocean, we propose an index, which is essentially the difference in Rayleigh-corrected reflectance between 412 and 443 nm bands of SeaWiFS. Radiative transfer simulations are conducted to show that the index is linearly related to the optical thickness of modeled dust-contaminated aerosol while showing insensitivity against non-absorbing model aerosols. Asian SeaWiFS data set of 2001 spring is used to produce daily composite imagery of the index, which compares well with TOMS Aerosol Index and with predicted aerosol optical thickness predicted by CFORS chemical weather forecast.

  • PDF

A DISCUSSION ON THE MAIN REASONS CAUSING THE MASS MORTALITY OF CORALS AND BENTHOS IN CONDAO ISLAND DURING OCTOBER 2005.

  • Son, Tong Phuoc Hoang;Khin, Lau Va;Ben, Hoang Xuan;Knee, Tan Chun;Ishizaka, Joji;Ransibrahmanakul, Varis;Tripathy, Sarat Chandra
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.463-466
    • /
    • 2006
  • During Mid October of 2005 a mass mortality of the corals occurred surrounding Con Dao Islands (South Vietnam) where is the recognized as one of the most famous marine parks of Vietnam. Results from the field survey in October 2005 showed that the mass mortality of corals and benthos focused only on the North-West of the islands whereas there was almost no death recorded in the South - East parts. Based on field data it was assumed that an overlap between high water temperature ($>30^{\circ}C$) and low salinity (<25%o) during short term was the impact causing the situation. In this paper, we try to explain this phenomenon based on the hydrographical view together with analyzing ocean colour images. A coral bleaching warning system also is proposed for Condao site.

  • PDF

Self-reliant wireless health monitoring based on tuned-mass-damper mechanism

  • Makihara, Kanjuro;Hirai, Hidekazu;Yamamoto, Yuta;Fukunaga, Hisao
    • Smart Structures and Systems
    • /
    • v.15 no.6
    • /
    • pp.1625-1642
    • /
    • 2015
  • We propose an electrically self-reliant structural health monitoring (SHM) system that is able to wirelessly transmit sensing data using electrical power generated by vibration without the need for additional external power sources. The provision of reliable electricity to wireless SHM systems is a highly important issue that has often been ignored, and to expand the applicability of various wireless SHM innovations, it will be necessary to develop comprehensive wireless SHM devices including stable electricity sources. In light of this need, we propose a new, highly efficient vibration-powered generator based on a tuned-mass-damper (TMD) mechanism that is quite suitable for vibration-based SHM. The charging time of the TMD generator is shorter than that of conventional generators based on the impedance matching method, and the proposed TMD generator can harvest 16 times the amount of energy that a conventional generator can. The charging time of an SHM wireless transmitter is quantitatively formulated. We conduct wireless monitoring experiments to validate a wireless SHM system composed of a self-reliant SHM and a vibration-powered TMD generator.

A study on Multi Mass System for MEMS vibratory Gyroscope (MEMS공진형 자이로스코프 응용을 위한 다중질량시스템에 관한 연구)

  • Hwang, Young-Seok;Jeon, Seung-Hoon;Jung, Hyoung-Kyoon;Lee, June-Young;Chang, Hyun-Kee;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.33-35
    • /
    • 2005
  • In this paper, a two-mass system for SiOG (Silicon on Glass) vibratory gyroscope with the need of frequency tuning was proposed to increase the stability of the device with wide bandwidth. Air damping and bandwidth were analyzed using MATLAB. The measured resonance frequency is 5.2 kHz, which is 7 kHz in the design. But the measured bandwidth is 450 Hz, similar to the designed bandwidth with 500 Hz. Also the frequency difference (210 Hz) between the driving and sensing part is smaller than the wide bandwidth of two mass system.

  • PDF

Fabrication of the Microchannel Integrated with the Inner Sensors for Accurate Measuring Fluid Temperature (유체의 정확한 온도 측정을 위하여 내부 센서를 집적한 마이크로채널 제작)

  • Park, Ho-Jun;Im, Geun-Bae;Son, Sang-Yeong;Song, In-Seop;Park, Jeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.449-454
    • /
    • 2002
  • A rectangular straight microchannel, integrated with the resistance temperature detectors(RTDs) for temperature sensing and a micro-heater for generating the Temperature gradient along the channel, was fabricated. Its dimension is 57${\mu}{\textrm}{m}$(H)$\times$200${\mu}{\textrm}{m}$(W)$\times$48,050${\mu}{\textrm}{m}$(L), and RTDs were placed at the inner-channel wall. Si wafer was used as a substrate. For the fabrication of RTDs, 5300$\AA$ thick Pt/Ti layer was sputtered on a Pyrex glass wafer. Finally, the glass wafer was bonded with Si wafer by anodic bonding, so that the RTDs are located inside the microchannel. Temperature coefficient of resistance(TCR) values of the fabricated Pt-RTDs were 2800~2950ppm$^{\circ}C$ and the variation of TCR value In the range of O~10$0^{\circ}C$ was less than 0.3%. Therefore, it was proved that the fabricated Pt-RTDs without annealing were excellent as temperature sensors. The temperature distribution in the microchannel was investigated as a function of mass flow rate and heating power. The temperature increase rate diminished with decreasing the applied power and increasing the mass flow rate. It was confirmed from the comparison with the simulation results that the temperature measured inside the microchannel is more accurate than measuring the temperature measured at the outer wall. The proposed temperature sensing method and microchannel are expected to be useful in microfluidics researches.