• 제목/요약/키워드: masonry wall's opening

검색결과 6건 처리시간 0.023초

나선형철물을 사용한 치장벽체 개구부 보강 효과에 관한 연구 (A Study on Reinforcement Effect of Face Wall with Opening using Spiral Anchor)

  • 정원철;황완선;권기혁
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.37-40
    • /
    • 2007
  • Although masonry buildings fell into disfavour in the 1990's because of factors such ac bricklayers' high labor costs, bad reputation of poorly constructed masonry, masonry face wall is still preferred in korea as well as in other countries for its decorative value. Recently may problems with masonry face wall with opening have been reported, including cracks, deflection, swelling and even wall collapse in old masonry buildings, that mainly induced from the corrosion of connecting materials. So, it is necessary to develop the effective and uncorrosion connector. Therefore, this study aims to investigate the structural performance of masonry face walls with opening constructed by new connectors, spiral stainless anchors and to provide basic data for the field application of this method. The specimen reinforced bed joint has maximum load and displacement any other specimens.

  • PDF

Experimental investigation of the shear strength of hollow brick unreinforced masonry walls retrofitted with TRM system

  • Thomoglou, Athanasia K.;Karabinis, Athanasios I.
    • Earthquakes and Structures
    • /
    • 제22권4호
    • /
    • pp.355-372
    • /
    • 2022
  • The study is part of an experimental program on full-scale Un-Reinforced Masonry (URM) wall panels strengthened with Textile reinforced mortars (TRM). Eight brick walls (two with and five without central opening), were tested under the diagonal tension (shear) test method in order to investigate the strengthening system effectiveness on the in-plane behaviour of the walls. All the URM panels consist of the innovative components, named "Orthoblock K300 bricks" with vertical holes and a thin layer mortar. Both of them have great capacity and easy application and can be constructed much more rapidly than the traditional bricks and mortars, increasing productivity, as well as the compressive strength of the masonry walls. Several parameters pertaining to the in-plane shear behaviour of the retrofitted panels were investigated, including shear capacity, failure modes, the number of layers of the external TRM jacket, and the existence of the central opening of the wall. For both the control and retrofitted panels, the experimental shear capacity and failure mode were compared with the predictions of existing prediction models (ACI 2013, TA 2000, Triantafillou 1998, Triantafillou 2016, CNR 2018, CNR 2013, Eurocode 6, Eurocode 8, Thomoglou et al. 2020). The experimental work allowed an evaluation of the shear performance in the case of the bidirectional textile (TRM) system applied on the URM walls. The results have shown that some analytical models present a better accuracy in predicting the shear resistance of all the strengthened masonry walls with TRM systems which can be used in design guidelines for reliable predictions.

Experimental and numerical investigation on in-plane behaviour of hollow concrete block masonry panels

  • Murthy, A. Rama Chandra;Ganapathi, S. Chitra;Iyer, Nagesh R.;Lakshmanan, N.;Bhagavan, N.G.
    • Computers and Concrete
    • /
    • 제10권1호
    • /
    • pp.1-18
    • /
    • 2012
  • This paper presents the details of studies conducted on hollow concrete block masonry (HCBM) units and wall panels. This study includes, compressive strength of unit block, ungrouted and grouted HCB prisms, flexural strength evaluation, testing of HCBM panels with and without opening. Non-linear finite element (FE) analysis of HCBM panels with and without opening has been carried out by simulating the actual test conditions. Constant vertical load is applied on the top of the wall panel and then lateral load is applied in incremental manner. The in-plane deformation is recorded under each incremental lateral load. Displacement ductility factors and response reduction factors have been evaluated based on experimental results. From the study, it is observed that fully grouted and partially reinforced HCBM panel without opening performed well compared to other types of wall panels in lateral load resistance and displacement ductility. In all the wall panels, shear cracks originated at loading point and moved towards the compression toe of the wall. The force reduction factor of a wall panel with opening is much less when compared with fully reinforced wall panel with no opening. The displacement values obtained by non-linear FE analysis are found to be in good agreement with the corresponding experimental values. The influence of mortar joint has been included in the stress-strain behaviour as a monolith with HCBM and not considered separately. The derived response reduction factors will be useful for the design of reinforced HCBM wall panels subjected to lateral forces generated due to earthquakes.

Numerical simulation of masonry shear panels with distinct element approach

  • Zhuge, Y.;Hunt, S.
    • Structural Engineering and Mechanics
    • /
    • 제15권4호
    • /
    • pp.477-493
    • /
    • 2003
  • Masonry is not a simple material, the influence of mortar joints as a plane of weakness is a significant feature and this makes the numerical modelling of masonry very difficult especially when dynamic (seismic) analysis is involved. In order to develop a simple numerical model for masonry under earthquake load, an analytical model based on Distinct Element Method (DEM) is being developed. At the first stage, the model is applied to simulate the in-plane shear behaviour of an unreinforced masonry wall with and without opening where the testing results are available for comparison. In DEM, a solid is represented as an assembly of discrete blocks. Joints are modelled as interface between distinct bodies. It is a dynamic process and specially designed to model the behaviour of discontinuities. The numerical solutions obtained from the distinct element analysis are validated by comparing the results with those obtained from existing experiments and finite element modelling.

Shear behaviour of Autoclaved Aerated Concrete (AAC) masonry walls with and without openings strengthened with welded wire mesh

  • Wanraplang Warlarpih;Comingstarful Marthong
    • Structural Engineering and Mechanics
    • /
    • 제87권5호
    • /
    • pp.487-498
    • /
    • 2023
  • Unreinforced masonry (URM) buildings are extensively adopted in many of the growing nations, particularly in India. Window or door openings are required for architectural or functional reasons, which pose a threat to the building's safety. The past earthquakes have shown that the seismic capability of these structures was very weak. Strengthening these unreinforced masonry walls using welded wire mesh (WWM) is one of the most commonly and economical methods. The present experimental study investigates the impact of openings on the shear behaviour of URM walls and the effectiveness of WWM in enhancing the shear performance of masonry wall. In the experimental program 16 specimens were cast, 8 unstrengthen and 8 strengthened specimens, under 8 unstrengthen and strengthened specimens, every 2 specimens had 0%, 5%, 10%, and 15% openings and all these walls were tested under diagonal compression. The results show that the shear carrying capacity reduces as the opening percentage increases. However, strengthening the URM specimens using WWM significantly improves the peak load, shear strength, ductility, stiffness, and energy dissipation. Furthermore, the strengthening of the URM walls using WWM compensated the loss of wall capacity caused by the presence of the openings.

도심지 흙막이 굴착시 인접구조물의 손상 평가연구 (The Evaluation of Damage Behaviour of Adjacent Structures in Urban Excavation)

  • 김학문;황의석
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.351-361
    • /
    • 2003
  • 흙막이 지반굴착시 인접 구조물의 손상메카니즘을 규명하기 위하여 1.844m(길이)$\times$0.6m(높이)인 모형조적벽체를 실제의 1/10의 스케일로 모형화하였다. Peck(1969) 및 O'Rourke등(1976)이 제안한 지반침하량이 6단계에 걸쳐 모형실험에 적용되었다. Peck(1969)과 O'Rourke등(1976)의 방법을 적용한 모형실험결과, O'Rourke등(1976)에 의한 조적벽체의 각변위는 Peck(1969)의 각변위에 비해 21% 크게 나타났으며, 수평변위 또한 Peck(1969)에 의한 값보다 24% 크게 나타났다. O'Rourke등(1976)의 침하량이 적용된 경우의 건물손상 정도를 손상도표(Boscardin & Cording,1989)에 적용한 결과 Peck(1969) 방법에 의해 얻은 손상수준에 비해 보다 심각한 손상수준의 결과가 나타났다. 또한, 구조물의 강성 및 구조물과 지반의 interface 가 구조물 손상평가시 중요한 인자로써 고려되어야 함을 확인할 수 있었다.