• 제목/요약/키워드: manual-scaling

검색결과 14건 처리시간 0.025초

Manual Scaling of Ionograms Measured at Jeju (33.4°N, 126.3°E) Throughout 2012

  • Jeong, Se-Heon;Kim, Yong Ha;Kim, Ki-nam
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.143-149
    • /
    • 2018
  • The ionosphere has been monitored by ionosondes for over five decades since the 1960s in Korea. An ionosonde typically produces an ionogram that displays radio echoes in the frequency-range plane. The trace of echoes in the plane can be read either manually or automatically to derive useful ionospheric parameters such as foF2 (peak frequency of the F2 layer) and hmF2 (peak height of the F2 layer). Monitoring of the ionosphere should be routinely performed in a given time cadence, and thus, automatic scaling of an ionogram is generally executed to obtain ionospheric parameters. However, an auto-scaling program can generate undesirable results that significantly misrepresent the ionosphere. In order to verify the degree of misrepresentation by an auto-scaling program, we performed manual scaling of all 35,136 ionograms measured at Jeju ($33.43^{\circ}N$, $126.30^{\circ}E$) throughout 2012. We compared our manually scaled parameters (foF2 and hmF2) with auto-scaled parameters that were obtained via the ARTIST5002 program. We classified five cases in terms of the erroneous scaling performed by the program. The results of the comparison indicate that the average differences with respect to foF2 and hmF2 between the two methods approximately correspond to 0.03 MHz and 4.1 km, respectively with corresponding standard deviations of 0.12 MHz and 9.58 km. Overall, 36 % of the auto-scaled results differ from the manually scaled results by the first decimal number. Therefore, future studies should be aware of the quality of auto-scaled parameters obtained via ARTIST5002. Hence, the results of the study recommend the use of manually scaled parameters (if available) for any serious applications.

치위생학과 학생들의 구강 내와 마네킹에서 기구 조작시 근골격계 통증과 불편감 (The Musculoskeletal Pain and Inconvenient Feeling During Hand Instruments with Mannequin and Intra-oral Cavity in Dental Hygiene Students)

  • 유자혜;노효련;이민영
    • 대한물리의학회지
    • /
    • 제3권4호
    • /
    • pp.247-254
    • /
    • 2008
  • Purpose : The purpose of this study was to analyze some factors that can cause incidence of the muscle and skeletal system trouble, by which Dental Hygiene Students examine the pain and the inconvenient feeling according to kinds in manual implements and the usability in the level of manipulating and maintaining the manual implement, in the actual training of the intra oral cavity along with mannequin given the scaling practice. Methods : Targeting 18 female juniors for the department of dental hygiene, who had directly practiced oral prophylaxis for 2 years, the questionnaire research was carried out right after the mutual practice in the intra oral cavity along with mannequin. Results : It was indicated that there is no big difficulty both in intra oral cavity and mannequin in terms of manipulating implement with a method of maintaining the rightly hand fixing or of grasping the trans formative pencil and of controlling force given manipulating the implement. How to grasp a trans formative pencil was indicated to be more difficult in the intra-oral manipulation(p<.05). Pain and inconvenient-feeling level, which occur in muscle and skeletal system during practicing the scaling in mannequin, were indicated to be in order of shoulder, wrist, neck, waist, elbow, and headache. Conclusion : There was no big difference in the pain and the inconvenient feeling in muscle and skeletal system according to mannequin and intra-oral environment given manipulating tile manual implement. However, there was difference in manipulating the implement with a method of grasping transformative pencil. The pain and inconvenient feeling in muscle and skeletal system were the highest both in shoulder and wrist.

  • PDF

자동화 프로그램을 이용한 아동의 전체두개강내용적 평가 (Total Intracranial Volume Measurement for Children by Using an Automatized Program)

  • 이정환;김지은;임성진;주가원;김시경;손정우;신철진;이상익;김혜리
    • 생물정신의학
    • /
    • 제21권3호
    • /
    • pp.81-86
    • /
    • 2014
  • Objectives Total intracranial volume (TIV) is a major nuisance of neuroimaging research for interindividual differences of brain structure and function. Authors intended to prove the reliability of the atlas scaling factor (ASF) method for TIV estimation in FreeSurfer by comparing it with the results of manual tracing as reference method. Methods The TIVs of 26 normal children and 26 children with attention-deficit hyperactivity disorder (ADHD) were obtained by using FreeSurfer reconstruction and manual tracing with T1-weighted images. Manual tracing performed in every 10th slice of MRI dataset from midline of sagittal plane by one researcher who was blinded from clinical data. Another reseacher performed manual tracing independently for randomly selected 20 dataset to verify interrater reliability. Results The interrater reliability was excellent (intraclass coefficient = 0.91, p < 7.1e-07). There were no significant differences of age and gender distribution between normal and ADHD groups. No significant differences were found between TIVs from ASF method and manual tracing. Strong correlation between TIVs from 2 different methods were shown (r = 0.90, p < 2.2e-16). Conclusions The ASF method for TIV estimation by using FreeSurfer showed good agreement with the reference method. We can use the TIV from ASF method for correction in analysis of structural and functional neuroimaging studies with not only elderly subjects but also children, even with ADHD.

Automated condition assessment of concrete bridges with digital imaging

  • Adhikari, Ram S.;Bagchi, Ashutosh;Moselhi, Osama
    • Smart Structures and Systems
    • /
    • 제13권6호
    • /
    • pp.901-925
    • /
    • 2014
  • The reliability of a Bridge management System depends on the quality of visual inspection and the reliable estimation of bridge condition rating. However, the current practices of visual inspection have been identified with several limitations, such as: they are time-consuming, provide incomplete information, and their reliance on inspectors' experience. To overcome such limitations, this paper presents an approach of automating the prediction of condition rating for bridges based on digital image analysis. The proposed methodology encompasses image acquisition, development of 3D visualization model, image processing, and condition rating model. Under this method, scaling defect in concrete bridge components is considered as a candidate defect and the guidelines in the Ontario Structure Inspection Manual (OSIM) have been adopted for developing and testing the proposed method. The automated algorithms for scaling depth prediction and mapping of condition ratings are based on training of back propagation neural networks. The result of developed models showed better prediction capability of condition rating over the existing methods such as, Naïve Bayes Classifiers and Bagged Decision Tree.

Comparison of the effect of hand instruments, an ultrasonic scaler, and an erbium-doped yttrium aluminium garnet laser on root surface roughness of teeth with periodontitis: a profilometer study

  • Amid, Reza;Kadkhodazadeh, Mahdi;Fekrazad, Reza;Hajizadeh, Farzin;Ghafoori, Arash
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: The present study aimed to measure root surface roughness in teeth with periodontitis by a profilometer following root planning with ultrasonic and hand instruments with and without erbium-doped yttrium aluminium garnet (Er:YAG) laser irradiation. Methods: Sixty single-rooted maxillary and mandibular teeth, extracted because of periodontal disease, were collected. The crowns and apices of the roots were cut off using a diamond bur and water coolant. The specimens were mounted in an acrylic resin block such that a plain root surface was accessible. After primary evaluation and setting a baseline, the samples were divided into 4 groups. In group 1, the samples were root planned using a manual curette. The group 2 samples were prepared with an ultrasonic scaler. In group 3, after scaling with hand instrumentation, the roots were treated with a Smart 1240D plus Er:YAG laser and in group 4, the roots were prepared with ultrasonic scaler and subsequently treated with an Er:YAG laser. Root surface roughness was then measured by a profilometer (MahrSurf M300+RD18C system) under controlled laboratory conditions at a temperature of $25^{\circ}C$ and 41% humidity. The data were analyzed statistically using analysis of variance and a t-test (P<0.05). Results: Significant differences were detected in terms of surface roughness and surface distortion before and after treatment. The average reduction of the surface roughness after treatment in groups 1, 2, 3, and 4 was 1.89, 1.88, 1.40, and 1.52, respectively. These findings revealed no significant differences among the four groups. Conclusions: An Er:YAG laser as an adjunct to traditional scaling and root planning reduces root surface roughness. However, the surface ultrastructure is more irregular than when using conventional methods.

새롭게 개발된 치아청결기의 치태제거 및 치은염증에 대한 효과 (Plaque Removing Efficacy and Effect on Gingival Inflammation of Newly Developed Tooth Cleansing Instrument)

  • 한동관;방은경;김창성;최성호;조규성;채중규;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.475-484
    • /
    • 2003
  • Many tooth cleansing instruments and agents have been developed for removal of plaque, inhibition of plaque formation and reduction of gingival inflammation. The aim of this study was to evaluate the plaque control effect and the therapeutic effect of newly developed tooth cleansing instrument(Belloblanco(R)). 40 healthy subjects with gingivitis or early periodontitis were divided into two groups. Subjects in control group only used manual tooth brushing and in experimental group used manual tooth brush and additive tooth cleansing instrument(Belloblanco(R)). Additive tooth cleansing instrument was used once a week. At baseline scaling and tooth brushing instruction was performed. Probing depth, bleeding on probing, plaque index, gingival index were scored at baseline, 2weeks, 4weeks. Probing depth of control and experimental group were significantly reduced at 2 weeks, 4weeks, hut there were no differences between two groups(P<(0.05). Bleeding on probing, plaque index and gingival index of control and experimental group were significantly reduced at 2weeks and 4weeks and there was significantly more reduction in the experimental group than the experimental group than the control group(p<(0.05). From these finding. it can be conclude that newly developed tooth cleansing instrument(Belloblanco(R)) are effective on the removal of plaque and the reduction of gingival inflammation

긴뼈의 형상 평균화 기법 (The Geometric Averaging Technique for Long Bone)

  • 곽대순;이우영;한승호;최광남;김태중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2006
  • Many authors issued the feature-preserving averaging technique according to positioning and scaling process using landmarks, which represent the geometric characteristics of three dimensional surface models. Such a technique should be done by manual procedure, choosing and marking the landmarks on each bone surface before averaging process. In this study, we produced another averaging technique without having to use such manual procedure, and made averaging models from three dimensional surface data that were reconstructed from computerized tomography images of Digital Korean Project. The bone models were subjected to orthogonal coordinator system. These models were transformed to coincide mass center and to align principal axis. Then, bone models were scaled according to average length data of sample bone models on all axis(x, y, z). After establishing voxellar hexahedron space which contain all sample bone models, we counted the number of overlapping for each voxel. We generated the three dimensional average surface by displaying the yokels that have more overlapping number than boundary number. The boundary number was decided when the average volume of each bone equal to the volume of bone that would be averaged. Using this technique, we can make a feature-preserving averaging volume of bones.

  • PDF

머신비전검사를 위한 기하학적 특징 기반 지능 패턴 정합 (Intelligent Pattern Matching Based on Geometric Features for Machine Vision Inspection)

  • 문순환;김경범;김태훈
    • 한국콘텐츠학회논문지
    • /
    • 제6권6호
    • /
    • pp.1-8
    • /
    • 2006
  • 본 연구에서는 인쇄회로기판을 위한 자동 광학 검사시스템에서 핵심적인 기능인 보정 데이타 산출을 위한 기하학적 특징 기반 방법을 제안하였다. 현재 적용되고 있는 자동 광학 검사 시스템에서는 보정데이타 산출을 위해 작업자가 직접 수작업으로 모델을 설정하고 있고, 검사영상에 기하학적인 변화가 있는 경우 비검사영역이 생기는 등 문제가 발생되고 있다. 이는 검사 작업의 신뢰성에 영향을 미치게 됨은 물론 검사 처리 시간을 지연시키는 요인이 된다. 제안된 방법은 주어진 PCB 영상으로부터 기하학적인 모양이 적합한 모델을 자동으로 선정할 수 있고, 기하학적인 모델 매칭 기법을 통해 신뢰성 있는 보정데이타를 산출할 수 있다. 제안된 방법의 사용으로 검사 시스템을 보다 편리하게 사용할 수 있고, 수작업에 의한 모델설정으로 발생되는 불필요한 시간을 절약할 수 있다. 또한, 기하학적인 변화량에 관계없이 보정데이타 산출이 가능하고, 잘못된 모델 선정 등 부정확한 보정데이터의 사용시 발생되는 문제점을 해결할 수 있는 장점을 갖는다.

  • PDF

초미세수술 로봇의 안정적인 원격조작을 위한 제어시스템 설계 (Control System Design for Stable Teleoperation of Supermicrosurgical Robot)

  • 김건욱;델가도 라이마리우스;인용석
    • 로봇학회논문지
    • /
    • 제19권2호
    • /
    • pp.169-175
    • /
    • 2024
  • In this study, we developed control system for stable teleoperation of supermicrosurgical robot platform. The supermicrosurgical robot platform is designed to perform precise anastomosis with micro vessels ranging from 0.3 mm to 0.7 mm. The robotic assistance could help more precise manipulation then manual surgery with the help of motion scaling and tremor filtering. However, since the robotic system could cause several vulnerabilities, control system for stable teleoperation should be preceded. Therefore, we first designed control system including inverse kinematics solver, clutch error interpolator and finite state machine. The inverse kinematics solver was designed to minimized inertial motion of the manipulator and tested by applying orientational motion. To make robot slowly converges to the leader's orientation when orientational error was occurred during clutch, the SLERP was used to interpolate the error. Since synchronized behavior of two manipulators and independent behavior of manipulator both exist, two layered finite state machines were designed. Finally, the control system was evaluated by experiment and showed intended behavior, while maintaining low pose error.

차세대 장수명 공동주택의 가변성능향상을 위한 건축요소기술 우선순위결정에 관한 연구 (Selection on the Order of Priority Factor of Construction Key Technology for Improving the Flexibility for a Long Life Apartment Housing at the Next Generation)

  • 이정석;조건희;손정락;김재준
    • 한국건설관리학회논문집
    • /
    • 제10권2호
    • /
    • pp.84-92
    • /
    • 2009
  • 최근 가변성능에 관하여 공간, 재료, 구조, 공법 등 건설 산업 전반에 걸쳐 많은 연구가 진행 중이며, 이와 더불어 공동주택의 노후화 문제로 인하여 건축요소기술의 개발이 가속화되고 있다. 이에 따라 본 연구에서는 최근 사회적으로 부각되고 있는 가변성능에 관한 공동주택의 요소기술 선정 및 대상사례를 중심으로 한 설문조사와 전문가 의견을 거쳐 건축요소기술의 평가항목을 1차적으로 선정하고자 한다. 그리고 선정된 건축요소기술 항목 중에서 타당성 및 객관성 검증절차를 통하여 건축요소기술을 재정립 및 분류하고, 최종적으로 적용 가능한 다양한 건축요소기술 가운데 우선순위가 높은 항목들을 결정하여 분석 및 평가함으로써 향후 장수명 공동주택의 가변성능향상을 위한 지침을 제시하고자 한다.