• Title/Summary/Keyword: manual calculation

Search Result 130, Processing Time 0.03 seconds

Study on the Method of Diagnosing the Individuals Crop Growth Using by Multi-Spectral Images

  • Dongwon Kwon;Jaekyeong Baek;Wangyu Sang;Sungyul Chang;Jung-Il Cho;Ho-young Ban;HyeokJin Bak
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.108-108
    • /
    • 2022
  • In this study, multispectral images of wheat according to soil water state were collected, compared, and analyzed to measure the physiological response of crops to environmental stress at the individual level. CMS-V multi-spectral camera(Silios Technologies) was used for image acquisition. The camera lens consists of eight spectral bands between 550nm and 830nm. Light Reflective information collected in each band sensor and stored in digital values, and it is converted into a reflectance for calculating the vegetation index and used. According to the camera manual, the NDVI(Normalized Difference vegetation index) value was calculated using 628 nm and 752 nm bands. Image measurement was conducted under natural light conditions, and reflectance standards(Labsphere) were captured with plants for reflectance calculation. The wheat variety used Gosomil, and the wheat grown in the field was transplanted into a pot after heading date and measured. Three treatments were performed so that the soil volumetric water content of the pot was 13~17%, 20~23%, and 25%, and the growth response of wheat according to each treatment was compared using the NDVI value. In the first measurement after port transplantation, the difference in NDVI value according to treatment was not significant, but in the subsequent measurement, the NDVI value of the treatment with a water content of 13 to 17% was lowest and was the highest at 20 to 23%. The NDVI values decreased compared to the first measurement in all treatment, and the decrease was the largest at 13-17% water content and the smallest at 20-23%. Although the difference in NDVI values could be confirmed, it would be difficult to directly relate it to the water stress of plants, and further research on the response of crops to environmental stress and the analysis of multi-spectral image will be needed.

  • PDF

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Impact Evaluation of Water Footprint on Stages of Drainage Works (배수공 각 작업 단계별 물발자국 영향평가)

  • Chen, Di;Kim, Joon-Soo;Batagalle, Vinuri;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.225-231
    • /
    • 2020
  • Fresh water that can be used by a person of the total amount of water on the planet is increased because it is less than 0.01 % except underground water, ice and snow, etc. water management response need. In order to protect and efficiently utilize water resources, major countries are conducting water footprint studies that can quantitatively estimate the amount of water put into the operating phase of the resource harvesting phase, mainly agriculture. Korea has also recently developed a number of policies in order to cope with water shortages, and in the construction industry, as well as the need for basic research to support it has been emphasized. This study was constructed DB up to the raw material harvesting step, the transport step, the production stage in order to estimate the water consumption of resources to be put into the work process to target the drainage of the road. Water usage estimation method was utilized the method presented in the Water Footprint Manual and the environmental score card certification guide, unit water usage each drainage main method was calculated after estimating the water footprint considering the water character factor, indirect water and the direct water, the water consumption factor of material input to each process. Brown asphalt, rebar, remicon of the drainage material as a result of the water footprint calculation accounted for 97 % of the total. Drainage method is a culvert, a side channel, a culvert wing wall, reinforced concrete open channel accounted for 92.2 % of the total. Drainage total step-by-step calculated water consumption and water footprint was found in order of raw material harvesting step, transport stage, production stage. Water footprint each drainage method or total drainage material calculated in this study can be used as a base data in the agricultural and construction sectors. In order to increase the reliability of the analysis, it is believed that further overseas databases will be needed for continuous review and research.

Calculation of Compensation to Parcels for Land Alternation Considering the Range of Adjoining Zone to Road (접도구역 구간을 고려한 토지이동 대상필지 보상비 산정)

  • LEE, Geun-Sang;CHOI, Myeong-Hei;CHOI, Yun-Woong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.16-27
    • /
    • 2015
  • The parcels of land alteration by existing manual work was very inefficient in terms of time and costs. Especially it caused many difficulty in estimating compensation since the work didn't take into account the range of adjoining zone to road. This study selected Gimje City of Jeollabuk-Do as a study site and could analyze the numbers and areas of parcels of land alteration considering the range of adjoining zone to road based on cadastral maps and wide road layers from new address system. Also this study applied a fuzzy membership function according to occupation ratio to road, and analyzed compensation by the range of adjoining zone to road using individual public land price information of the parcels for land alternation. Especially, the change aspect of public and private parcels could be investigated by the range of adjoining zone to road according to the fuzzy membership function. And this study could provide very efficient data in determining the priority of the parcels for land alternation through calculating compensation of the parcels for land alternation by Eup Myeong Dong according to the range of adjoining zone to road.

Mechanical Analysis of the Force on Landing 3 Type Curves(Ellipse, Circle, Brachistochrone) of Halfpipe (스노우보드 하프파이프 점프시 착지 충격에 관한 3가지 곡선(타원, 원, 브라키스토크론)의 역학적 해석)

  • Lee, Un-Hak;Kim, Kew-Wan;Park, In-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.1-19
    • /
    • 2008
  • This research is to analyze the force on landing 3 Type of Halfpipe Curves(Ellipse, Circle, Brachistochrone) based on the mechanical calculation of normal force on a sloping surface. Jumping off a platform on a bard horizontal surface, the flexing of the legs, the softness of the snow, the angle of the landing surface, initial velocity and the forward motion of the snowboarder can contribute to reducing the force on landing. But halfpipe is significantly determined by the curvature of surface. It is definitely verified that the Brachistochrone curve is more safety than others. However currently using the Ellipse curve is mostly safe too. If we consider the efficiency of construction, we can easily think there is no use of another curves except normal ellipse curved halfpipe. It would better that geometrically verity curved halfpipe should be designed for improving fluent skills to snowboarders. This methode of research can be a model of scientifical research on sports safety how can sportsman reduce critical injury by designing optimal halfpipe facilities and manual.

Determining Ideal Distance between Consecutive Exit Ramps (고속도로 연결로상 연속 분류지점 간의 이격거리 검토)

  • Lee, Seongkwan Mark;Lee, Ki Young;Jang, Jung Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.65-72
    • /
    • 2011
  • When an expressway intersects another expressway, a unique connector needs to be designed between the two consecutive exit ramps. In such a case, it is important to design a connector such that there is enough distance for drivers to find their way safely. A current design manual in Korea prescribes the minimum length of the connector as 240 m. In this research, we have suggested a method for calculating the minimum length of a connector in order to check the feasibility of the currently prescribed length. For this purpose, we have attempted to determine the total perception-reaction time and lane-changing time required by a driver. For determining the driver's perception-reaction time, we have used the driver's decision time in addition to the conventional 2.5 s of perception-reaction time for stopping sight distances. We have considered both the design speed and the average travel speed for the calculation of the length. To evaluate the accuracy of the new method, we have chosen four sites on expressways for which relatively high accident rates were recorded. As a result, we could verify that the current limit (240 m) was sufficient for drivers to be able to change lanes in the given specific geometry. However, the prescribed limit should be revised in case the drivers' decision time is considered to be their perception-reaction time. All new approaches for calculating the ideal length of a connector have been carried out by taking into account the design speed as well as the average travel speed. Owing to the characteristics of the specific geometry for two consecutive exit ramps and the large difference between the design speed and the average travel speed in the objective areas, it is more realistic to use the proposed method by keeping the decision time equal to a driver's perception-reaction time, in order to determine the ideal distance that should be maintained between two consecutive exit ramps.

How about IRMA Curve (IRMA 법 Curve에 관하여)

  • Chang, Hyunyeong;Sin, Sunyoung;Lee, Hyunju;Woo, Jearyong;Lee, Hoyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.

  • PDF

Residual Stresses Analysis due to Volumetric Changes in Long-term Autogenous Expansive Concrete (장기팽창성 콘크리트의 체적변화에 의한 잔류응력 해석)

  • Cha, Soo-Won;Jang, Bong-Seok;Oh, Byung-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.6
    • /
    • pp.617-625
    • /
    • 2009
  • This study is devoted to the problems of thermal and autogenous expansion stresses in order to avoid cracking using chemically prestressing method. The chemical prestress can be induced by autogenous expansion characteristics of MgO concrete made in specific burning temperature. The volume change induced cracking has great influence on the long-term durability and serviceability. To evaluate risk of cracking, the computer programs for analysis of thermal and autogenous expansion stresses were developed. In these 3-D finite element procedures, long-term autogenous expansive deformation is modeled and its resultant stress is calculated and then verified by comparison with manual calculation results. In this study, the stress development is related to thermal and autogenous expansive deformation. Using the developed program, residual stresses of MgO concrete were compared and analysed in the example From the numerical results it is found that long-term, and temperature dependent expansive concrete with light-burnt MgO is most effective in controlling the risk of cracking of mass concrete because it has high temperature for long period. The developed analysis program can be efficiently utilized as a useful tool to evaluate the thermal and autogenous expansion stresses in mass concrete structures with lightly burnt MgO.

A Study on Pk(Probability of Kill) Calculation Method of the Direct Fire Weapon System using Simulation (시뮬레이션 기반 직사화기 무기체계의 살상확률 산정 방법에 관한 연구)

  • Choi, Yun Ho;Lee, Ki Teak;Pyun, Jai Jeong;Jang, Young Cheon
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.3
    • /
    • pp.115-123
    • /
    • 2017
  • Dispite the fact that our military has outwardly made notable accomplishments such as the development of weapon systems like tanks, self-propelled artillery, and missiles, there has been a lack of attention to producing weapon effectiveness data that suggests a standard as to what effects the developed weapons will demonstrate on the battlefield. For such reasons, most of the weapon effectiveness data utilizes JMEM data introduced by the United States and as for the rest of the data that cannot be acquired, respective branches create and utilize their own data through research. This research aims to develop a reliable methodology that can meet the requirements of the requesting branches in a short span of time and at a low cost by studying the existing weapon effectiveness data production methodologies such as that of JMEM. As a result I have developed a method that calculates the vulnerable area and the probability of kill of the weapon system that one wants to calculate by applying statistical technique and simulation technique based on weapon effectiveness data of similar weapon systems in JMEM and live test data.

A Study on the Evaluation Method of Soil Treatment Termiticide (흰개미 토양처리제 효과 평가 및 시험방안 연구)

  • Im, Ik Gyun;Jeong, Seon Hye;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.177-186
    • /
    • 2019
  • A Termiticide that is applied to the soil treatment method, one of the methods for preventing termites in Korea's wooden cultural properties, will be subjected to the leaching of the effective ingredient in treated soil by the moisture behavior of rain. As a result, termiticide is deteriorated and needs to be reprocessed, but the standards and evaluation methods are nonexistent in korea. Accordingly, a basic indoor evaluation measure was proposed for the evaluation of the effectiveness of the termiticide chamber and the calculation of the reprocessing period. First, avoidance and contact toxicity were assessed at two concentrations of the same termiticide as a method for assessing termiticide suitability. The evaluation of mortality revealed that the soil termiticide used in this experiment was non-repellent, and that death from contact was confirmed. Afterwards, artificial rainfall and soil penetration tests were conducted to determine efficacy of termiticide in soil and the approximate reprocessing period was calculated by comparing the weather data. Persistence evaluation revealed perforation by termites after continuous water exposure of more than about 160 to 170mm of water injection condition. Based on the results, compared with weather data for the last five years, the termiticide of concentration used in this experiment is expected to remain effective for about one year if treated after September. The purpose of this study was to provide basic data for the establishment of a manual for the selection of termiticide for soil treatment by calculating the efficacy for termite mortality and the duration of the leaching effectiveness by water behavior in soil.