• Title/Summary/Keyword: mammography

Search Result 374, Processing Time 0.037 seconds

Implementation of a Full Field Digital Mammography (디지털 유방X-선촬영기의 구현)

  • Roh, Young-Sup;Yeo, Se-Yeon;Lee, Jae-Jun;Sohn, Surg-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4578-4589
    • /
    • 2011
  • The technologies of image acquisition, display, and storage of the breast have been developed in their specialized fields in recent years. The image acquisition system is a device that absorbs and stores images after examining breast tissue using X-ray. Due to the specificity and sensitivity of imaging, the early detection of breast cancer is feasible. In this paper, the current technologies for digital mammography are reviewed, and we propose a digital mammography and evaluate the performance of the implemented system.

A Study of Quality Control Environment of Mammography (유방촬영의 화질관리 환경에 대한 고찰)

  • Hwang, In-Sun;Kim, Young-Keun;Joo, Hyung-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • The purpose of this study was to survey and test quality control of mammography system. The conclusion of this study is as follows ; First, The rate of pass for phantom image test shows that Film-Screen mammography system(F/S) and computed mammography system(CR) is 80%, Indirect digital mammography system(DR) is 100%. Second, The test of exposure dose shows that F/S is 921 mR. CR is 1,140 mR, DR is 474 mR. The grade of this testament is CR > F/S > DR. Third, The test of average glandular dose shows that F/S is 1,336 mGy, CR is 1,635 mGy, DR is 1,26 mGy. The grade of this testament is CR > F/S > DR. Fourth, The testament of resolution shows as follows F/S is 11~13 Lp/mm, CR is 4~5 Lp/mm, and DR is 5~7 Lp/mm(F/S > DR > CR) Fifth, The survey of projection, cassette, development and reading shows that user are indifference.

  • PDF

Evaluation of Clinical Image on Observational Condition in Mammography (유방촬영시 관찰조건에 따른 임상영상평가)

  • Kim, Mi-Hyun;Kim, Chang-Bok;Ji, Youn-Sang;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • High contrast and high resolution are the most important factors for examining mammography images. Despite of the inconveniences of screen-film, most clinics still prefer them to computed radiography(CR) and direct radiography(DR). The reading of screen-film mammography images is influenced by the brightness from the X-ray illuminator, the exam room and incoming light from outside sources. Therefore, a comparative analysis on the results of mammo phantom images would be variated by the changes in the reading environment. There was no influence on reading results from the examiners close distance eyesight(p > 0.05); however, reading of micro lesions improved with greater darkness in the X-ray film reading room and the brightness of the X-ray illuminator(p < 0.05). Also, observation of fiber and mass images were maximized at a distance of 50 cm from the reader. Now, it is possible to observe these small classification groups using a magnifying glass without being physically close to the image. For the image of mammography, obtaining high quality images is important but in order to get an accurate clinical lesions of the reading also needs to be considered the optimal environmental factors.

  • PDF

A Feasibility Study on the Improvement of Diagnostic Accuracy for Energy-selective Digital Mammography using Machine Learning (머신러닝을 이용한 에너지 선택적 유방촬영의 진단 정확도 향상에 관한 연구)

  • Eom, Jisoo;Lee, Seungwan;Kim, Burnyoung
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Although digital mammography is a representative method for breast cancer detection. It has a limitation in detecting and classifying breast tumor due to superimposed structures. Machine learning, which is a part of artificial intelligence fields, is a method for analysing a large amount of data using complex algorithms, recognizing patterns and making prediction. In this study, we proposed a technique to improve the diagnostic accuracy of energy-selective mammography by training data using the machine learning algorithm and using dual-energy measurements. A dual-energy images obtained from a photon-counting detector were used for the input data of machine learning algorithms, and we analyzed the accuracy of predicted tumor thickness for verifying the machine learning algorithms. The results showed that the classification accuracy of tumor thickness was above 95% and was improved with an increase of imput data. Therefore, we expect that the diagnostic accuracy of energy-selective mammography can be improved by using machine learning.

Suppression Technics for Mammography

  • Jang Meoung Mi;Ahh Chin Shin;Kim Seon Hee;Chung Kyung Mo;Lee Yong Woo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.22-22
    • /
    • 1999
  • There is patient's complain, problem of mammography, with increasing mammography every year. We tried to find out how much the pain can be decreased through power of compression, number of compression and change of study style with having maintain existin

  • PDF

Breast Cancer Diagnosis by Mammography in Kazakhstan - Staging Results of Breast Cancer with Double Reading

  • Beysebayev, Eldar;Tulebayev, Kazbek;Meymanalyev, Tylek
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.31-34
    • /
    • 2015
  • While mammography has been used for diagnosis of breast cancer in Kazakhstan for a long period, published data are very limited. Recently stress has been placed on increasing the accuracy by double reading of mammograms. Here we provide an overview of breast cancer screening in the different regions of Kazakhstan with data on the stages of cancers detected. A total 459,816 women aged 50, 52, 54, 56, 58 and 60 years were screened in 2012 and 379,903 in the first 9 months of 2013. Clear differences in levels of detection were noted between urban and rural residents, the latter demonstrating lower rates for both screening and cancer detection. Women aged 50 were more likely to undergo screening than their counterparts aged 60. While there were no clear relationships evident between screening rates and stage or numbers of breast cancers observed, this might be due to a number of complicating factors like geographical variation in risk factors as well as ethnicity. Future analyses should focus on the efficacy of mammography in Kazakhstan to reduce mortality.

The Role of Scintimammography in the Diagnosis of Breast Cancer (유방암 진단에서 유방스캔의 역할)

  • Kim, In-Ju
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.213-223
    • /
    • 2001
  • Breast cancer accounts for the higher proportion of cancer related deaths among women, and the incidence of this malignant disease is still increasing. The commonly used screening method is mammography. However, mammography has the drawback of low specificity in differentiating malignant and benign breast diseases. To overcome this low specificity of mammography, scintimammography using various radiopharmaceuticals such as Thallium-201, Tc-99m MIBI, Tc-99m tetrofosmin and Tc-99m MDP was introduced and now actively under the investigation. Several studios have shown that high sensitivity and specificity in detection of primary breast cancer and axillary lymph node metastases using these radiopharmaceuticals. Scintimammography may play important roles in the diagnosis of primary breast cancer, evaluation of the patients with high risk, determining axillary lymph node metastasis, evaluation of the response to chemotherapy, determining the extent of disease, and surveillance of local recurrence. In the future, we should investigate the prognostic role of scintimammography after treatment of breast cancer patients and cost-effectiveness of scintimammography in the detection of primary breast cancer.

  • PDF

Factors Related to Breast Cancer Screening using Mammography and Clinical Breast Examination of Korean Women Over 40 Years of Age (한국 도시여성의 유방촬영술과 유방임상검사 관련요인)

  • Eun, Young;Gu, Mee-Ok;Lee, Eunice L.;Choi, Kyung-Sook;Jun, Myung-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.6
    • /
    • pp.580-592
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the factors related to Breast cancer Screening using Mammography and CBE of Korean women over 40 years of age. Methods: The participants for this study were 183 Korean women living in 3 urban cities and aged from 40 to 75. The data were collected using structured questionnaires which included sociodemographic factors (11 items), frequency and regularity of mammography and clinical breast examination (7 items), knowledge (16 items), health belief model scale (28 items), and family support (4 items) about breast cancer and breast cancer screening. Frequencies, Chronbach's alpha for reliability, Chi-square, t-test and logistic regression with the SPSS/WIN 12 program were used to analyze the data. Results: The percentages of Korean women who had a mammography and CBE for breast cancer screening were 60.1 and 31.1, respectively. Logistic regression analyses demonstrated that regular check ups and perceived barriers were significant predictors of mammography and CBE use for breast cancer screening. Conclusion: In order to increase the frequency of breast cancer screening practices, educational support and a health care delivery system is needed to improve the chance of regular health check ups.

  • PDF

Women's Cancer Screening According to Body Mass Index in a Cohort of Rural Korean Women (강원지역 농촌코호트 여성의 체질량 지수에 따른 여성암 검진행위)

  • Kim, Bo-Hwan;Koh, Sang-Baek;Hur, Hea-Kung;Park, Jong-Ku;Park, So-Mi
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.5
    • /
    • pp.641-650
    • /
    • 2009
  • Purpose: This study was done to examine the difference in cancer screening with mammography and Papanicolaou smear according to Body Mass Index (BMI). Methods: The participants in this study were 5,912 women ages 40 to 69 yr, selected from the Korean Genomic Regional Cohort in Kangwon province. Mammography and Papanicolaou smear were assessed by questionnaire and body weight (kg) and height (m) measured to calculate BMI. Results: The distribution of BMI was as follows: low weight (1.5%), normal weight (31.1%), over weight (24.6%), mildly obese (36.4%) and severely obese (6.3%). After adjusting for age, education and monthly income, compared with normal weight women, overweight women (odds ratio [OR]=1.283, 95% confidence interval [CI]=1.089-1.513) and mildly obese women (OR=1.214, 95% CI=1.048-1.406) were less likely to have had mammography. In contrast to mammography, cancer screening with Papanicolaou smear was not significantly different by BMI. Conclusion: Obese women in rural areas are less likely to screen for breast cancer by using mammography than non obese women. To ensure regular screening for breast cancer, health care providers need to give scrupulous care to obese women and remove barriers originated from obesity. Also, educational and clinical implications are considered to increase the Papanicolaou smear rate.

Compliance with Screening Recommendations According to Breast Cancer Risk Levels in Izmir, Turkey

  • Acikgoz, Ayla;Ergor, Gul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1737-1742
    • /
    • 2013
  • Early diagnosis has a major role in improving prognosis of breast cancer. The purpose of this study was to assess the risk status of women 35-69 years of age using risk assessment models and the prevalence of mammography in a community setting. The sample of this cross sectional study consisted of 227 women, 35-69 years of age residing in Izmir, a city located in western region of Turkey. A questionnaire was used to collect data and the Gail and Cuzick-Tyrer models were applied to assess the risk of breast cancer. In this study, 52.7% of women had mammography at least once, and 41.3% of the women over the age of 40 had mammography screening in the last two years. The five years risk for breast cancer was high in 15.8% of women according to the Gail model and ten years risk was high in 21.7% with the Cuzick-Tyrer model. In the present study, the breast cancer risk levels were assessed in a population setting for the first time in Turkey using breast cancer risk level assessment models. Being in 60-69 age group, having low education and not being in menopause were significant risk factors for not having mammography according to logistic regression analysis. Mammography utilization rate was low. Women must be educated about breast cancer screening methods and early diagnosis. The women in the high risk group should be informed on their risk status which may increase their attendance at breast cancer screening.