• 제목/요약/키워드: mammaplasty

검색결과 118건 처리시간 0.022초

Perforator Reconstruction to Salvage the Jeopardized Flaps

  • Eom, Jin Sup;Choi, Dong Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • 제24권1호
    • /
    • pp.24-27
    • /
    • 2015
  • During flap elevation, most perforators are cut except one or more perforators that are essential to flap survival. However these cutout perforators can cause deterioration of the blood circulation of the flap. To salvage the jeopardized flaps, rebuilding the perforator system is essential for flap survival. In the first case, after flap elevation, the upper abdominal flap margin was severely ischemic. To supply blood to the upper abdominal flaps, we found and used a major perforator underneath the upper abdominal flap which was cut earlier during the elevation, and we performed reanastomosis with ipsilateral deep inferior epigastric artery. Upper abdominal flap ischemic area was limited to a narrow suture area. In the second case, we performed free superficial inferior epigastric artery (SIEA) flap reconstruction. After successful anastomosis of the SIEA and superficial inferior epigastric vein (SIEV) with internal mammary artery and vein, serious venous congestion occurred immediately because of SIEV malfunction. We found the largest perforator vein under the flap, as an alternate way to drain, then connected it with the thoracoacromial vein with a vein graft harvested in the contralateral SIEV. Circulation has improved. In conclusion, perforator system reconstruction is essential in a jeopardized flap salvage.

동시 유륜절개 유방하수교정술 및 확대술: 이중평면 대 근막밑평면 (Simultaneous Periareolar Augmentation Mastopexy: Dual Plane Versus Subfascial Plane)

  • 심형보;윤상엽
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose: The major drawback of submuscular augmentation of the ptotic breast is a "double-bubble" deformity. If a traditional mastopexy is added to correct the ptosis, there would be additional scars. This article describes simultaneous periareolar mastopexy with dual plane or subfascial breast augmentations. Methods: A series of 81 patients with grade I or II ptosis underwent the procedure from 1999 to 2005. Out of these, dual plane augmentation was done in 71 cases and subfascial plane in 10. After periareolar skin excision, an incision is made perpendicularly down to the fascia of pectoralis. At the lower pole, all breast implants are inserted into the subfascial plane. In case of upper pole thickness of above 20 mm, we inserted the implant into the subfascial plane, whereas below 20 mm, we inserted that into the submuscular plane. Results: No major complications were noted and patients' satisfactory score was high. This technique avoids the "double-bubble" deformity and leaves a minimal periareolar scar. Conclusion: Simultaneous periareolar mastopexy/breast augmentation is useful for correction of the ptotic breast, increasing the volume of breast and providing the natural breast shape with minimal scars. We consider that subfascial plane augmentation with periareolar mastopexy to be an alternative for cases with breast upper pole thickness of at least above 20 mm.

Robotic harvest of a latissimus dorsi flap using a single-port surgical robotic system in breast reconstruction

  • Joo, Oh Young;Song, Seung Yong;Lew, Dae Hyun;Park, Hyung Seok;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제48권6호
    • /
    • pp.577-582
    • /
    • 2021
  • Robot-assisted surgery is evolving to incorporate a higher number of minimally invasive techniques. There is a growing interest in robotic breast reconstruction that uses autologous tissue. Since a traditional latissimus dorsi (LD) flap leads to a long donor scar, which can be an unpleasant burden to patients, there have been many attempts to decrease the scar length using minimally invasive approaches. This study presents the case of a patient who underwent a robot-assisted nipple-sparing mastectomy followed by immediate breast reconstruction with an LD flap using a single-port robotic surgery system. With the assistance of a single-port robot, a simple docking process using a short and less visible incision is possible. Compared to multiport surgery systems, single-port robots can reduce the possibility of collision between robotic arms and provide a clear view of the medial border of the LD where the curvature of the back restricts the visual field. We recommend the use of single-port robots as a minimally invasive approach for harvesting LD flaps.

Finite element analysis of long-term changes of the breast after augmentation mammoplasty: Implications for implant design

  • Myung, Yujin;Lee, Jong-Gu;Cho, Maenghyo;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.386-389
    • /
    • 2019
  • The development of breast implant technology continues to evolve over time, but changes in breast shape after implantation have not been fully elucidated. Thus, we performed computerized finite element analysis in order to better understand the trajectory of changes and stress variation after breast implantation. The finite element analysis of changes in breast shape involved two components: a static analysis of the position where the implant is inserted, and a dynamic analysis of the downward pressure applied in the direction of gravity during physical activity. Through this finite element analysis, in terms of extrinsic changes, it was found that the dimensions of the breast implant and the position of the top-point did not directly correspond to the trajectory of changes in the breast after implantation. In addition, in terms of internal changes, static and dynamic analysis showed that implants with a lower top-point led to an increased amount of stress applied to the lower thorax. The maximum stress values were 1.6 to 2 times larger in the dynamic analysis than in the static analysis. This finding has important implications for plastic surgeons who are concerned with long-term changes or side effects, such as bottoming-out, after anatomic implant placement.

Early experiences with robot-assisted prosthetic breast reconstruction

  • Ahn, Sung Jae;Song, Seung Yong;Park, Hyung Seok;Park, Se Ho;Lew, Dae Hyun;Roh, Tai Suk;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제46권1호
    • /
    • pp.79-83
    • /
    • 2019
  • Robotic surgery facilitates surgical procedures by employing flexible arms with multiple degrees of freedom and providing high-quality 3-dimensional imaging. Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed to avoid breast scars. Four patients with invasive ductal carcinoma underwent robot-assisted nipple-sparing mastectomy and immediate robot-assisted expander insertion. Through a 6-cm incision along the anterior axillary line, sentinel lymph node biopsy and nipple-sparing mastectomy were performed by oncologic surgeons. The pectoralis major muscle was elevated, an acellular dermal matrix (ADM) sling was created with robotic assistance, and an expander was inserted into the subpectoral, sub-ADM pocket. No patients had major complications such as hematoma, seroma, infection, capsular contracture, or nipple-areolar necrosis. The mean operation time for expander insertion was 1 hour and 20 minutes, and it became shorter with more experience. The first patient completed 2-stage prosthetic reconstruction and was highly satisfied with the unnoticeable scar and symmetric reconstruction. We describe several cases of immediate robot-assisted prosthetic breast reconstruction. This procedure is a feasible surgical option for patients who want to conceal surgical scars.

Single-port robot-assisted prosthetic breast reconstruction with the da Vinci SP Surgical System: first clinical report

  • Joo, Oh Young;Song, Seung Yong;Park, Hyung Seok;Roh, Tai Suk
    • Archives of Plastic Surgery
    • /
    • 제48권2호
    • /
    • pp.194-198
    • /
    • 2021
  • Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed in an attempt to seek smaller and indistinct incisions. Robotic surgery system has been evolving under the concept of minimal invasive technique which is a recent trend in surgery. One of the latest version is the da Vinci SP Surgical System (Intuitive Surgical). In this report, we will share our experiences. Two patients underwent robot-assisted nipple-sparing mastectomy, each followed by immediate robot-assisted expander insertion and prepectoral direct-to-implant breast reconstruction, respectively. There was no open conversion or major postoperative complication. One patient experienced mild infection, which was resolved by intravenous antibiotic treatment. Simple docking process, multi-joint instruments, and thirdarm functionality are among the new surgical system's advantages. The present cases suggest that robot-assisted nipple-sparing mastectomy with immediate reconstruction using the da Vinci SP Surgical System is feasible and safe. The promising features and potential application of da Vinci SP in breast reconstruction need further study.

Long V-Y advancement technique for large nipple reconstruction in Asian women

  • Jang, Nam;Kim, Junekyu;Shin, Hyun Woo;Suk, Sang Woo
    • Archives of Plastic Surgery
    • /
    • 제48권1호
    • /
    • pp.44-48
    • /
    • 2021
  • Previously reported nipple-areolar complex reconstruction (NAR) methods involve multiple incisions and wide skin redraping, which increase retraction forces and heighten the risk of nipple-areolar complex (NAC) flattening. We introduce a NAR method using the long V-Y advancement technique that can overcome these disadvantages. A V-shaped flap is designed with the width of the flap base 4-5 mm larger than the diameter of the normal nipple. The flap length is designed to be at least 2.5 times its width. Dissection is performed to the top of the artificial dermal matrix or muscle layer. The nipple is constructed with the same projection as the contralateral side by folding the elevated flap. The tip of the elevated flap is apposed in the middle of the donor defect to minimize the deformity during donor site closure. A 3-point skin suture is applied to the upper third of the folded flap to mold its shape. Using this long V-Y advancement technique, we successfully decreased skin tension in NAC flaps and improved the maintenance of reconstructed nipple projection. The long V-Y advancement technique provides an easy, simple NAR method, effectively maintaining longer nipple projections and reducing breast deformities, especially in Asian women with relatively large nipples.

Gigantomastia as a Cause of Pulmonary Hypertension

  • Castillo, Juan Pablo;Robledo, Ana Maria;Torres-Canchala, Laura;Roa-Saldarriaga, Lady
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.369-372
    • /
    • 2022
  • Reduction mammaplasty is the gold standard treatment for gigantomastia. We report one female patient with juvenile gigantomastia associated with severe pulmonary hypertension where her pulmonary pressure decreased significantly after the surgery, improving her quality of life. A 22-year-old female patient with gigantomastia since 10 years old, tricuspid regurgitation, and pulmonary thromboembolism antecedent was admitted to the emergency department. Her oxygen saturation was 89%. Acute heart failure management was initiated. An echocardiogram reported left ventricle ejection fraction (LVEF) of 70% with severe right heart dilation, contractile dysfunction, and arterial pulmonary pressure (PASP) of 110 mm Hg. A multidisciplinary team considered gigantomastia could generate a restrictive pattern, so a Thorek reduction mammoplasty with Wise pattern was performed. Presurgical measurements were: sternal notch to nipple-areola complex, right 59 cm, left 56 cm. Three days after surgery, the patient could breathe without oxygen support. In the outpatient follow-up, patient referred reduction of her respiratory symptoms and marked improvement in her quality of life. Six months after surgery, a control echocardiogram showed a LVEF of 62% and PASP of 85 mm Hg. Pulmonary hypertension may be present in patients with gigantomastia. Reduction mammoplasty may be a feasible alternative to improve the cardiac signs and symptoms in patients with medical refractory management.

A Comparison of Smooth and Microtextured Breast Implants in Breast Augmentation: A Retrospective Study

  • Joo Hyuck Lee;Jae Hyuk Jang;Kyung Hee Min
    • Archives of Plastic Surgery
    • /
    • 제50권2호
    • /
    • pp.160-165
    • /
    • 2023
  • Background The number of cosmetic and reconstructive surgeries that use breast implants is increasing in Korea. Recently, it has been reported that breast implant-associated anaplastic large-cell lymphoma is related to textured breast implants, and interest in classification according to the texture of breast implants is increasing. However, there is currently no clear and unified classification. In particular, the definition of "microtextured" is highly varied. In this study, we retrospectively investigated and analyzed the clinical outcomes of smooth and microtextured breast implants. Methods A retrospective chart review of all patients who underwent breast augmentation surgery with smooth and microtextured silicone gel implants between January 2016 and July 2020 was performed. We retrospectively analyzed implant manufacturer, age, body mass index (BMI), smoking status, incision location, implant size, follow-up period, complications, and reoperation rate. Results A total of 266 patients underwent breast augmentation surgery, of which 181 used smooth silicone gel implants and 85 used microtextured silicone gel implants. Age, BMI, smoking status, implant size, and follow-up period were not significantly different between the two groups. Similarly, complications and reoperation rates were not significantly different between the two groups. Conclusion It is important to provide information regarding the clinical risks and benefits of breast implants to surgeons and patients through a clear and unified classification according to the texture of the breast implant.

Nipple Reconstruction with Rolled Dermal Graft Support

  • Chia, Hui-Ling;Wong, Manzhi;Tan, Bien-Keem
    • Archives of Plastic Surgery
    • /
    • 제41권2호
    • /
    • pp.158-162
    • /
    • 2014
  • Background Loss of nipple projection is a common problem following nipple reconstruction. The aim of this study was to demonstrate that the use of a tightly rolled dermal graft is effective in the long-term maintenance of nipple projection. Methods Nipple reconstruction was performed using the C-V flap technique. A dermal graft was harvested from the dog-ear portion of previous scars. The graft was rolled tightly into a compact cylinder and used to augment the nipple reconstruction. Postoperatively, stacked Allevyn dressing was used for protecting the nipple from compression for a minimum of two months. Nipple projection was measured at the time of surgery and at 12 months postoperatively. Results Forty nipple reconstructions were performed using this technique. There were 19 transverse rectus abdominis musculocutaneous (TRAM) flaps, 10 latissimus dorsi (LD) flaps, and 11 tissue-expanded breast mounds. At one year, the mean projection was 0.80 cm (range, 0.62-1.22 cm). The twelve-month average maintenance of nipple projection was 70.2% for the TRAM flap group, 76.3% for the LD flap group, and 61.8% for the tissue-expanded group. In two patients with previous irradiation of the reconstructed breasts, relatively poor maintenance of nipple projection was noted (45.7%). No complications were noted, and all of the donor sites healed well primarily. Conclusions Our results demonstrated that the use of a C-V flap with a tightly rolled dermal graft for nipple reconstruction improves the long-term maintenance of nipple projection. Its advantages include reproducibility, technical simplicity, cost-effectiveness, and minimal donor site morbidity.